Instruction Manual Modbus Converter Unigate-CL-RS

Similar documents
MODBus RTU for AKOCAM and AKOPRO controllers

Modbus Protocol For TGP03 / THP03

Modbus Protocol For FTS/FTM 3x&8x

CTT MODBUS-RTU COMMUNICATION PROTOCOL TEMPERATURE MONITOR DEVICE

VISY-Command. Technical Documentation. with Modbus Protocol. Edition: Version: 1 Art. no.:

Modbus Protocol For PMX / PXM3X

IQ Home Modbus-RTU Master

E2 Modbus RTU Register Map Revision History Version Comments Author Date 1.02 Previous version PAE 11/06/ Revised to new format PAE 09/03/09

Real Time Clock with Temperature Sensor and RS485/Modbus Comunications

B Interface description 12.01/

JUMO ctron 04/08/16. Compact controller with timer and ramp function. B Interface Description Modbus /

Setting the DCM Switches

Modbus RTU/TCP Installation and Programming Guide PC3400 Particle Counter

ModBUS Protocol for SMART 3

How to set-up and read MOBBUS

SC2004MBS 20x4 Characters MODBUS RTU Slave LCD

Interface design document MODBUS Protocol. Ab s t r a c t Description of the MODBUS implementation for the Modbus I/O board

FnIO S-Series. FnIO MODBUS Adapter Specification Rev 1.00 NA-9473 (MODBUS/RS485) Page 1 of 30. NA-9473 (MODBUS/RS485) Adapter

M-BUS Standard acc. EN AE.05:04.01: Protocol Specification

DataVU 5 - Interface Manual Modbus

DataVU 5 - Interface Manual Modbus

Revision 1.2. July 24, COM Protocol Manual. for MDC and ADC N 11th St - San Jose CA

E2 Modbus RTU Register Map

Rev 1.3, Air-Farm User Manual. CO2 / Temperature / Humidity Transmitter

Manual BrainCube Connect with Modbus Master

VD SERIES CONTROLLERS (VERSION4.0) RS-485 COMMUNICATION INSTRUCTION MANUAL MODBUS Protocol Reference Guide

TR600 with RS485 Appendix 1

MODBUS APPLICATION MANUAL DFC-0124

N700E Inverter RS485 Interface Instruction Manual

MODBUS TESTER SOFTWARE U S E R M A N U A L

SAFETY PRECAUTIONS. Throughout this manual we use the following two illustrations to make you aware of safety considerations:

Optris CT/ CTlaser/ CTvideo communication interface

J1939/Modbus Slave Gateway FAQ

4511 MODBUS RTU. Configuration Manual. HART transparent driver. No. 9107MCM102(1739) For 4511 devices from ser. no:

JUMO di 308. Digital Indicator. B Interface Description Modbus 12.07/

Using the MODBUS Protocol with Athena Series C (1ZC, 16C, 18C, and 25C) Controllers

BCT SERIES CONTROLLERS (VERSION 3.0) RS-485 COMMUNICATION INSTRUCTION MANUAL MODBUS Protocol Reference Guide

Modbus _RTU (Memory Map)

It is the installer's responsibility to follow all instructions in this manual and to follow correct electrical practice.

JUMO Quantrol LC100/LC200/LC300

Power Xpert C445 Motor Management Relay Cheat Sheets

[ 公司地址 ] Modbus Protocol. For THS/THM 30X&80X_Temp.&Humididy & THS8X/THM8X_Dew Point Series V7.0

LCD Module with I2C / Serial Interface and Keypad Control «LCD I2C/Serial» User s Guide. Copyright 2008 IMS

WRC Modbus to DeviceNet Gateway for GPD 506/P5

Design of Communication Function Test System for Intelligent Low Voltage Electrical Apparatus Based on LabVIEW and Modbus RTU Protocol

Modbus Protocol. for VASCO, VASCO Solar and MIDA devices. manmodbus_eng_00

Revision 1.3. Sept 26, COM Protocol Manual. for MDC and ADC N 11th St - San Jose CA

CAS SEC (Serial) Protocol for Mitsubishi UPS. Gateway

SC1602LC 16x2 Large Characters RS232 LCD Module. User s Manual. Large Viewing Area 99mm x 24mm. Large Character Size. 4.84mm x 9.66mm.

Conto D1 MODBUS COMMUNICATION PROTOCOL

Description of communication protocols of Txxxx series

Optidrive VTC Modbus RTU Register Map

Hello Angles... A First Use Guide to the SOLAR Product Series: RS485 Interface with ModBus RTU Communication Protocol.

T7 Modbus Communication User Guide

Chapter 5: Communications 5 1 SR55 Communications Overview 5 2

isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw

INTELLIS. Modbus Direct Network Monitor

PoolPak SWHP Series ECCIII Modbus RTU BAS Interface DOCUMENT #: SVW05-ECCIIIMODBUS

RS485 INSTRUCTION MANUAL. DM4500 Series. Page 1 of 6

ModBus Communication protocol. The ModBus protocol is an industrial communications and distributed control system

Website: Technical Support: Skype: fcwkkj or Jason.chen842 Phone: QQ Group:

SC1602LCPro-YG ( Yellow Green Backlight ) SC1602LCPro-B ( Blue Backlight ) Large Character Size ( 4.88x9.66 mm )

JUMO dtron 304/308/316 JUMO dtron 304/308/316 plast

Interface Definition RISH EM 2340/1320/30/ _Rev. D - 8/2016

Additional instructions Memograph M, RSG45 Advanced Data Manager

General Monitors S5000 Modbus Specification. Order No.: MANS5000M/00. MSAsafety.com

G0313 Modbus to FF Gateway User Manual

EGW1-IA3-MB User s Manual

Golander Peristaltic Pump MODBUS Communication Instruction

LUMIPLUS MODBUS MANUAL V1.0. Fluidra, S.A All Rights Reserved.

THERMOSALD ISX RS485 MODBUS (V5) 3E S.r.l. - Via del Maccabreccia 37/a LIPPO DI CALDERARA (BOLOGNA) THERMOREGULATOR for PULSE WELDING

Communication protocols description of. Hx4xx and Hx3xx regulators with RS485 and RS232 communication interface

0.1. [0x8A] Read Configuration

SPM90 MODBUS PROTOCOL AND REGISTER LIST V1.0

MODBUS Protocol. The ecode Encoders contain both single register (16 bit) and double register (32 bit) values.

Modbus/ PROFIBUS DP Gateway PM-160

OPTRIS CT/CTL communication interface

Protocol VIT5. Communications RS485. Version 1.0. Pg.Up ENTER. Pg.Up ENTER. Pg.Up ENTER. Pg.Up ENTER. Pg.Up ENTER. Pg.Up ENTER. Pg.Up ENTER. Pg.

1. Introduction. 2. Installation MODBUS INTERFACE

EXD-TEVI Economizer Controller for Tandem Compressors

LUFP7. A way to make Masterpact available on Profibus. Version /2007

Beijer Electronics has no obligation to supply the holder with updated versions.

OPTRIS CT communication interface

Conto D2 COMMUNICATION PROTOCOL CONTENTS 1.0 INTRODUCTION

MCW Application Notes 24 th February 2017

MODBUS APPLICATION MANUAL DKM-411

FLUIDWELL GENERAL MODBUS COMMUNICATION PROTOCOL

The benefits are ease of set-up, more data available for the user from the drive, fast control, and state of the art technology.

4511 MODBUS RTU. Configuration Manual. Solenoid / alarm driver. No. 9203MCM100(1328)

Modbus on SenseAir S8

Sample F4T 32-bit Modbus RTU Packet

TECH TIP. Tritex Modbus Protocol Specification

RTD-NET Installation Instructions

User Guide. Modbus Module. For Digistart soft starters. Part Number: Issue: 3.

Stabiliti Modbus Programming Guide

Sample F4T 32-bit Modbus RTU Packet

COMMUNICATION MODBUS PROTOCOL

GA4000 SERIES CONTROLLERS (VERSION 6.0) MODBUS Protocol Reference Guide

JDICON 1000 JDICON B Interface Description 3.99/ Universal Process Controller. Universal Profile Controller

TECHNICAL NOTES By6150-S-485 MODBUS J BUS Communication

Transcription:

BA_MODBUS-Gateway_e_2011-12-16.doc, Stand: 16.12.2011 (Subject to technical changes)

1 Introduction The Unigate-CL-RS Module serves as gateway between the ExTox RS232 Interface and the bus system of the customer (Modbus). Every second the ExTox Control Units ET-4D2 and ET-8D send a defined protocol via RS232 Interface. All data is buffered in the module and can be read out on Modbus side every time. It is possible to run several modules on the same bus. Therefore it is important to assign a clear address to each module. 2 Assignment of address The address is adjusted at the module by means of the two turn able dip switches S6 (high nibble) and S7 (low nibble) in hexadecimal format. Example: S6 is "B" S7 is "3" Modbus address is "B3" (hex) = "179" (decimal) 2.1 Adjustment of type of Interface By means of the turn able dip switch S4 the type of Modbus Interface is adjusted. Three positions are possible: 0: RS232 1: RS422 2: RS485 2.2 Adjustment of Baud Rate: Via dip switch S5 the Modbus baud rate is adjusted. Here ten positions are possible: 0: 300 Baud 1: 600 Baud 2: 1200 Baud 3: 2400 Baud 4: 4800 Baud 5: 9600 Baud 6: 19200 Baud 7: 38400 Baud 8: 57600 Baud 9: 115200 Baud The position of the dip switch is only read out once on switching-on. In case for example a slave address should be changed, the module has to be switched off and on after adjusting the dip switch. Factory sided setting is RS485 and 9600 Baud. BA_MODBUS-Gateway_e_2011-12-16.doc, Seite 2 von 5

3 Modbus Protocol 3.1 General Transfer mode is the RTU-Mode (Remote Terminal Unit). Modbus ASCII is not supported. Data format is "8N1" (8 Data bits, no parity, 1 Stop bit). Modbus requests are only answered for the functional codes 0x03 and 0x04 (reading of words). On one request maximum 80 words (160 Bytes) can be read out. The Master sends a request to the slave. This request consists of 8 Bytes. The protocol is as follows: 1. Byte: Slave address 2. Byte: Functional code (0x03 or 0x04) 3. & 4. Byte: Address first word to be read (16 Bit Word) 5. & 6. Byte: Number of words to be read (16 Bit Word) 7. & 8. Byte: CRC16 Check sum (16 Bit Word) The Slave answer in the following format: 1. Byte: Slave address 2. Byte: Functional code (0x03 or 0x04) 3. Byte: Number of read Bytes from 4. Byte: Data bytes then: CRC16 Check sum (16 Bit Word) It has to be considered that it is only possible to read out words and no single bytes. But it is possible to address memory byte wise, that means to read out from any byte address. BA_MODBUS-Gateway_e_2011-12-16.doc, Seite 3 von 5

3.2 Memory assignment of buffer (from ET4/ET8 Rev. 100728): Remark: Independent from the connected control unit ET-4D2 or ET-8D the memory assignment is equivalent. If an ET-4D2 is used the measurement value "zero" will be send for channels 5 to 8. Also alarm status for channels 5 to 8 will be "No alarm" always. Byte 0 Start sign (0x24) Byte 1 Life sign (0x30-0x39) every second Byte 2 Number of measuring point (0x30 0x36) Byte 3 Status of system: 0x30=Air, 0x31=Rinse, 0x32=Measurement Byte 4..9 Byte 10..15 Byte 16..21 Byte 22..27 Byte 28..33 Byte 34..39 Byte 40..45 Byte 46..51 Measured value Channel 1 in µa ASCII, leading zero=blank Measured value Channel 2 in µa ASCII, leading zero=blank Measured value Channel 3 in µa ASCII, leading zero=blank Measured value Channel 4 in µa ASCII, leading zero=blank Measured value Channel 5 in µa ASCII, leading zero=blank Measured value Channel 6 in µa ASCII, leading zero=blank Measured value Channel 7 in µa ASCII, leading zero=blank Measured value Channel 8 in µa ASCII, leading zero=blank Byte 52 Alarm 1 / Channel 1: 0x30=no Alarm, 0x31=Alarm Byte 53 Alarm 1 / Channel 2: 0x30=no Alarm, 0x31=Alarm Byte 54 Alarm 1 / Channel 3: 0x30=no Alarm, 0x31=Alarm Byte 55 Alarm 1 / Channel 4: 0x30=no Alarm, 0x31=Alarm Byte 56 Alarm 1 / Channel 5: 0x30=no Alarm, 0x31=Alarm Byte 57 Alarm 1 / Channel 6: 0x30=no Alarm, 0x31=Alarm Byte 58 Alarm 1 / Channel 7: 0x30=no Alarm, 0x31=Alarm Byte 59 Alarm 1 / Channel 8: 0x30=no Alarm, 0x31=Alarm Byte 60 Alarm 2 / Channel 1: 0x30=no Alarm, 0x31=Alarm Byte 61 Alarm 2 / Channel 2: 0x30=no Alarm, 0x31=Alarm Byte 62 Alarm 2 / Channel 3: 0x30=no Alarm, 0x31=Alarm Byte 63 Alarm 2 / Channel 4: 0x30=no Alarm, 0x31=Alarm Byte 64 Alarm 2 / Channel 5: 0x30=no Alarm, 0x31=Alarm Byte 65 Alarm 2 / Channel 6: 0x30=no Alarm, 0x31=Alarm Byte 66 Alarm 2 / Channel 7: 0x30=no Alarm, 0x31=Alarm Byte 67 Alarm 2 / Channel 8: 0x30=no Alarm, 0x31=Alarm Byte 68 Alarm 3 / Channel 1: 0x30=no Alarm, 0x31=Alarm Byte 69 Alarm 3 / Channel 2: 0x30=no Alarm, 0x31=Alarm Byte 70 Alarm 3 / Channel 3: 0x30=no Alarm, 0x31=Alarm Byte 71 Alarm 3 / Channel 4: 0x30=no Alarm, 0x31=Alarm Byte 72 Alarm 3 / Channel 5: 0x30=no Alarm, 0x31=Alarm Byte 73 Alarm 3 / Channel 6: 0x30=no Alarm, 0x31=Alarm Byte 74 Alarm 3 / Channel 7: 0x30=no Alarm, 0x31=Alarm Byte 75 Alarm 3 / Channel 8: 0x30=no Alarm, 0x31=Alarm BA_MODBUS-Gateway_e_2011-12-16.doc, Seite 4 von 5

Byte 76 Fault / Channel 1: 0x30=no Fault, 0x31=Fault Byte 77 Fault / Channel 2: 0x30=no Fault, 0x31=Fault Byte 78 Fault / Channel 3: 0x30=no Fault, 0x31=Fault Byte 79 Fault / Channel 4: 0x30=no Fault, 0x31=Fault Byte 80 Fault / Channel 5: 0x30=no Fault, 0x31=Fault Byte 81 Fault / Channel 6: 0x30=no Fault, 0x31=Fault Byte 82 Fault / Channel 7: 0x30=no Fault, 0x31=Fault Byte 83 Fault / Channel 8: 0x30=no Fault, 0x31=Fault Byte 84 Fault Housing fan: 0x30=no Fault, 0x31=Fault Byte 85 Fault Flow-through: 0x30=no Fault, 0x31=Fault Byte 86 Fault Communication: 0x30=no Fault, 0x31=Fault Byte 87 Fault int. current: 0x30=no Fault, 0x31=Fault Byte 88 Fault int. Check sum: 0x30=no Fault, 0x31=Fault Byte 89 Byte 90 End sign 1 (0x0D) End sign 2 (0x0A) BA_MODBUS-Gateway_e_2011-12-16.doc, Seite 5 von 5