POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Similar documents
STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Instruction Manual Model Block Translator

MONITOR Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

ANT CNTR DC ALRM LNB RX DC ALRM +18V OFF

Model L 10MHz Frequency Source, Switch, Inserter

Model x-Series

S-Band Redundant LNA Systems

Series 8900 LAN. Operation Manual. Part Number (example configuration) Part Number (example configuration)

RE-82 RACK MOUNT DIMMER OWNERS MANUAL. 8 X 2400Watts. Revision /29/2007

Series 8000 RF Signal Switch Solution

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

ES-600 Ozone Controller Operation Manual

Enhanced Mini-Chansim Model VCS-232

Series 8000 RF Signal Switch Solution

OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR065-48S / OPR065-48R. Manual

B Polling Interface

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

V-9939B MICROPHONE ADAPTER

VIP-804 QUAD ENHANCED NETWORK AUDIO PORT

Chassis Power Supplies

MODEL No. SW1X8 RS422 SWITCHER

User's Guide. Programmable DC Power Supply 200 Watt (40 Volts / 5 Amps) Model Introduction

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

VIP-812A DUAL NETWORKED STATION PORT

EtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X

1073N. Channel Amplifier. User Manual Issue 1.3

OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL

CA-A480-A Elevator Controller. Reference & Installation Manual

V-9908 MESSAGE/PAGE PANEL

OZONE SWITCH Model OS-6. OS-6 Features

500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System

TRC-190 User s Manual

Model No. ST200-S-RCP

VE8014A/VE8014AR QUAD NETWORKED STATION PORT

imaging Series Quartet Guide to Installation and Operation M

Rev Cutler-Hammer Smart Breaker Panel Control Manual

User Manual. Per Port Monitoring Models

LASER PLUS OPERATING INSTRUCTIONS

TRC-190 User s Manual

TB-100 ControLynx Terminal Block

Table of Contents. 1. Introduction Package Contents Function Installation Web Interface... 4

T-Monitor E-Monitor TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...3 SECTION 3 - INSTALLATION...5

NT1-220 Rack. Installation Instructions. Specifications. Contents of Shipping Box. Important Safety Instructions. NT1-220 Rack

NAVE IIc. Nielsen Audio Video Encoder Compressed. Quick Start Guide

FA-2448 SIX POSITION Filter Wheel

The Analyst. RS422/RS232 Tester. (Standard Model) User Manual

FVT/FVR20D2I1C4E INSTALLATION AND OPERATION MANUAL

Switched XPDU. 15A Model. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

AirTest Model CN9000 Series Sensor Controller

ANC Series RS-422 Serial Communications Adapter

Remote Microprocessor Control Panel. for use with the. Redi-Purge. High Efficiency Purge System

Prisma II Platform. Optoelectronics

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL

ViaLite RF Splitter / Combiner

IKS-G6524A/G6824A Series Quick Installation Guide

MD9 MULTIDROP INTERFACE INSTRUCTION MANUAL

20W Tungsten-Halogen Light Source. Operation Manual

CMSA-100 Manual. Cinema Media Server Automation

Flex Control Network. Model No. DC20/ DC21 DEVICE CONTROLLER. Rev 2 Hardware

TC1880 Series. 4/5/6/8 Channel RS-232 FIBER OPTIC MICRO MUX User's Manual

SC532A 9-PIN PERIPHERAL TO RS232 INTERFACE INSTRUCTION MANUAL

DX/256x256 SERIES SOLID STATE DIGITAL SWITCHING SYSTEMS

iconverter 2-Module Power Chassis

UTAH-100/XHDA SERIES

1:N REDUNDANT SWITCHING UNIT BROADBAND SERIES

Installation & Operation Guide

1:1 C-Band LNA Redundancy System

ASYNC Sharing Unit TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...5 SECTION 3 - INSTALLATION...7

WR-5e Remote Control

ASYNC Sharing Unit TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...5 SECTION 3 - INSTALLATION...7

TDM-150 TIMER DISPLAY

PagePac PAGEPAC PLUS ZONE EXPANSION UNIT V

FD141CV-C-1. Installation and Operation Manual. 14 Widescreen HD Display. Revision Date: 05/04/2017 Page 1 of 15. Rev: B

Owner s Manual. TSD-DCPDV DC Power Distribution with Fixed & Variable Outputs. TSD-DCPDV DC Power Distribution. AtlasSound.com

Ashly WR-5 Remote Control

Integrated Stepper Drive & Motor

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE

Plus-X 300. Installation and Operation Manual

SC32A OPTICALLY ISOLATED RS232 INTERFACE INSTRUCTION MANUAL

EOS-6000 Series Optical A/B Switch User Manual DC Version

NT1B-300 Rack Installation Instructions

1:N REDUNDANT SWITCHING UNIT REMOTE CONTROL TERMINAL

AEXX SERIES MULTI-FUNCTION CLOCK/TIMERS

Universal Switch Panel USP-KEYSERVER. User Manual

Arrakis Systems 6604 Powell Street / Loveland, Colorado 80538

IC693PWR331 High Capacity Power Supply, 24 VDC Input

PMDX-108-Output. 8-Channel Isolated Output Board for PC parallel port pins 2-9. User s Manual

Data Broadcast Switch

RS422 PORT SWITCHER REMOTE CONTROL PANEL

AS-AMP1 40 Watt Digital Amplifier User Manual

INSTRUCTION MANUAL RA 19-5B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

SMD Series Integrated Stepper Driver and Motor Revision 1.3

ACLD Channel Opto-isolated Digital Input Board

SECURE/NONSECURE LED SIGN USER MANUAL

DCM Digital Control Modules

Model# ANI SWH. Ver. 1.1

M82xxD Fiber Optic RS-232 MicroModem Technical Manual

Model NM512. TS1 Conflict Monitor Standard 12 Channel Unit. Naztec Operations Manual. For. Published by

Transcription:

Instruction Manual Model 1582-10M Protection Switch January 2009 Rev O ALARMS MENU OUTPUT = CH1 AUTO POWER 1 2 MODEL 1582 SWITCH CROSS TECHNOLOGIES INC. CH1 CH2 REMOTE EXECUTE Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., but may be reproduced or duplicated without the prior permission of Cross Technologies, Inc. for purposes of operating the equipment. When ordering parts from Cross Technologies, Inc., be sure to include the equipment model number, equipment serial number, and a description of the part. CROSS TECHNOLOGIES, INC. 6170 Shiloh Road Alpharetta, Georgia 30005 (770) 886-8005 FAX (770) 886-7964 Toll Free 888-900-5588 WEB www.crosstechnologies.com E-MAIL info@crosstechnologies.com

INSTRUCTION MANUAL MODEL 1582-10M PROTECTION SWITCH TABLE OF CONTENTS PAGE Warranty 2 1.0 General 3 1.1 Equipment Description 3 1.2 Technical Specifications 4 1.3 Monitor and Control Interface 5 1.4 M&C Commands 6 2.0 Installation 8 2.1 Mechanical 8 2.2 Rear Panel Inputs and Outputs 8 2.3 Front Panel Controls and Indicators 8 2.4 Installation/Operation 9 2.5 Menu Settings 10 2.6 Use Information 13 WARRANTY - The following warranty applies to all Cross Technologies, Inc. products. All Cross Technologies, Inc. products are warranted against defective materials and workmanship for a period of one year after shipment to customer. Cross Technologies, Inc. s obligation under this warranty is limited to repairing or, at Cross Technologies, Inc. s option, replacing parts, subassemblies, or entire assemblies. Cross Technologies, Inc. shall not be liable for any special, indirect, or consequential damages. This warranty does not cover parts or equipment which have been subject to misuse, negligence, or accident by the customer during use. All shipping costs for warranty repairs will be prepaid by the customer. There are not other warranties, express or implied, except as stated herein. CROSS TECHNOLOGIES, INC. 6170 Shiloh Road Alpharetta, Georgia 30005 (770) 886-8005 FAX (770) 886-7964 Toll Free 888-900-5588 WEB www.crosstechnologies.com E-MAIL info@crosstechnologies.com 1582-10 Manual Page 2 1/22/09

MODEL 1582-10M Protection Switch 1.0 General 1.1 Equipment Description - The 1582-10M 1:1 Switch, 10 MHz provides Auto, Manual or Remote relay switching between CH1 and CH2, 10 MHz signals. Alarm conditions on CH1 and CH2 are a level drop below -6 dbm of the 10 MHz signal. The 1582-10M switches from CH1 to CH2 only if CH1 alarms and CH2 is good. The unit switches back when CH1 is no longer in alarm or both CH1 and CH2 are bad. When power is lost and when power is applied (as alarms at power up dictate), CH1 is selected. Front panel LEDs indicate CH1 and CH2 alarms, Remote mode (yellow), and redundant power supplies on (green). Multi-function push button switches select Auto, Local, or Remote operation and the signal path in the Manual mode. Remote operation via the RS232/RS485 M&C interface allows selection of CH1 or CH2 and indicates switch position and alarm status. A contact closure to ground indicates if either or both CH1, CH2 are in alarm. An LCD display shows Auto, Local or Remote operation and the signal path. Connectors are BNC, female for the 10 MHz signals and DB9 for M&C and for the alarm contact closure output. The 1582-10M is a 1RU chassis with redundant power supplies fed by separate fused 100-240 ±10% VAC AC input connectors. ALARMS MENU OUTPUT = CH1 AUTO POWER 1 2 MODEL 1582 SWITCH CROSS TECHNOLOGIES INC. CH1 CH2 REMOTE EXECUTE AC1 AC2 GND MONITOR AND CONTROL CH1 INPUT CH2 INPUT REFERENCE OUTPUTS 5 4 3 2 1 9 8 7 6 J19 J13 J20 J1 J5 J6 J7 J8 J9 J10 J11 J12 (Ethernet Optional) (4 or 8 Ports Optional) 1582-10M FRONT AND REAR PANEL CH 1 IN 10 MHz CH 2 IN 10 MHz OUTPUT = CH1 AUTO SWITCHED 10 MHZ OUT ALARM DET CH1 ALARM DET CH2 CONTROLLER MULTI- FUNCTION SWITCHES M&C SUMMARY ALARM CONTACT CLOSURE 1582-10M BLOCK DIAGRAM 1582-10 Manual Page 3 1/22/09

1.2 Technical Specifications 1582-10M Technical Specifications Switch Characteristics Impedance 75 ohms Type Non-latching Relay Isolation >50 db DC to 10 MHz Switch level/time -6±1dB / 100 milliseconds Insertion Loss 1 db Configuration SPDT Alarm and Control, M&C Alarm output signal M & C Interface M & C Signal Form C relay: 30VDC, 0.5A max RS232C or RS485, selectable, (Ethernet Optional) 38.4 kb baud rate Controls, Indicators Mode Select Power On Status Remote Select Status Manual Select Status Alarm Status Local/Remote, Auto/Manual - push-button switches, contact closures, or remote selection Green LEDs, (PS1, PS2), Yellow LED, M&C serial M&C serial Red LEDs, External Form C contact closure, M&C serial Connectors, Other Ext. Alarm, M&C Conn. DB9 (female) 10 MHz In/Out BNC, female, 75 ohm Size 1 RU, 19 inch standard chassis 1.75 high X 16.0 deep Power Redundant 100-240 ±10% VAC, 47-63 Hz, 20 W max. power supplies Options - 4 4-75 outputs - 8 8-75 outputs - W8 Ethernet M&C *Specifications subject to change without notice 1582-10 Manual Page 4 1/22/09

1.3 Monitor and Control Interface A) Remote serial interface Protocol: RS-232C, 9600 baud rate, no parity, 8 data bits, 1 start bit, and 1 stop bit. (RS-232C, RS-422, or RS-485 - option -Q) M&C Cable Diagram - Cross Technologies Frequency Converters Female DB-9 PC Com Port 1 2 3 4 5 6 7 8 9 Male DB-9 2015/16/17 M&C Port 1 2 3 4 5 6 7 8 9 Connector: Rear panel, DB-9 female J10 Pinouts (RS-232C/422/485) Pin Function 1 Rx- 2 Rx+ (RS-232C) 3 Tx+ (RS-232C) 4 Tx- 5 GND 6 Alarm Relay: Common 7 Alarm Relay: Normally Open 8 Not Used 9 Alarm Relay: Normally Closed 1582-10 Manual Page 5 1/22/09

1.4 M&C Commands The following tables summarize the commands and status queries applicable to the 1582-10M Protection Switch. * PLEASE NOTE: The two character {aa} prefix, shown in the table below, is present ONLY when RS485 is selected. Table 2.0 Model 1582-10M - M&C Remote Commands Table 2.0: Model 1582-10M M&C Remote Commands Commands Remote Select Syntax {aacrx} Description where: x = 0: clears remote selections x = 1: remote select CH1 x = 2: remote select CH2 In Auto Switching Mode {aacmx} where: x = 0: disables min. auto switching mode x = 1: enables min. auto switching mode 1.5 M&C Queries Table 2.1 Model 1582-10M - M&C Status Commands Table 2.1: Model 1582-10M M&C Status Commands Commands Model # and firmware version Syntax {aasv} Description returns: {aasv 1582-10M v 400} model # & firmware version Remote Select Status {aasr} returns: {aasax} where: X = 0 if no remote selections X = 1 if CH1 is remotely selected X = 2 if CH2 is remotely selected In Auto Switching Mode Status {aasm} returns: {aasmx} where: X = 0 if min. auto switching is disabled X = 1 if min. auto switching is enabled Continued on page 7... 1582-10 Manual Page 6 1/22/09

Table 2.2 Model 1582-10M - M&C Status Commands - Continued Table 2.1: Model 1582-10M Status Commands Alarms Status M&C Status Commands - Continued Syntax Description {aasa} returns: {aasaxy} where: X = 0 if CH1 is not alarmed X = 1 if CH1 is alarmed y = 0 if CH2 is not alarmed y = 1 if CH2 is alarmed Switch Position {aasp} returns: {aaspxy} where: X = 1 if CH1 is selected X = 2 if CH2 is selected y = 0 if switch mode is Auto y = 1 if switch mode is Remote y = 2 if switch mode is Manual 1582-10 Manual Page 7 1/22/09

2.0 Installation 2.1 Mechanical - The 1582-10M is rack mounted by attaching the front panel to a rack through the four holes at the edges of the panel. 2.2 Front and Rear Panel Controls and Indicators - The following are the front and rear panel controls and indicators. CH1 LED illuminates red when the 10 MHz input to CH1 drops below -6 dbm CH2 LED illuminates red when the 10 MHz input to CH2 drops below -6 dbm ALARMS MENU OUTPUT = CH1 AUTO POWER 1 2 MODEL 1582 SWITCH CROSS TECHNOLOGIES INC. CH1 CH2 REMOTE EXECUTE REMOTE LED illuminates yellow when the remote interface is enabled. POWER 1, 2 illuminates green when the respective power supplies are on. AC1 AC2 GND MONITOR AND CONTROL CH1 INPUT CH2 INPUT REFERENCE OUTPUTS 5 4 3 2 1 9 8 7 6 AC1, AC2 - POWER IN AC inputs for switching power supplies. 100-240 ± 10% VAC, 47-63 Hz. J19 J13 J20 J1 J5 J6 J7 J8 J9 J10 J11 J12 (Ethernet Optional) (4 or 8 Ports Optional) FIGURE 2.3 1582-10M Front AND REAR Panel Controls and Indicators 1582-10 Manual Page 8 1/22/09

2.3 Installation / Operation 2.3.1 Installing and Operating the 1582-10M, Protection Switch Section 1. Connect primary 10 MHz signal to CH1 In/out, J13 2. Connect backup 10 MHz signal to CH2 In/out, J1 3. Connect selected 10 MHz output, J5, to external equipment. 4. Connect primary 100-240 ±10% VAC, 47-63 Hz to AC1 on the back panel. 5. Connect secondary 100-240 ±10% VAC, 47-63 Hz to AC2 on the back panel. 6. Set the gain for -10 to +30 db. Make sure the output stays within -20 to 0 dbm with the gain selected 7. AC Fuse - The fuse is a 5 mm X 20 mm, 2 amp slow blow (Type T) and is inserted in the far slot in the drawer below the AC input as shown in Figure 2.3. There is a spare fuse in the near slot. NOTE: If a fuse continues to open, the power supply is most likely defective. FUSE DRAWER SPARE FUSE DRAWER AC Fuse - 2 amp slow blow (Type T 2A GDC), 5 mm X 20 mm INPUT~ ~ 100-240± 10%VAC 47-63 Hz 2A MAX FUSE TYPE T 2A GDC 250 VOLT FOR 100-240 V~ FIGURE 2.4 Fuse Location and Spare Fuse 1582-10 Manual Page 9 1/22/09

2.4 Menu Settings 2.4.1 Functions This section describes operation of the front panel controls. There are three ope rator switches, the LCD display and alarm indicator LEDs. All functions for the equipment are controlled by these components. The functions are (see Figure 2.3): Power Up Normal Display Menu 1 Menu 2 Menu 3 Menu 4 Menu 5 Manual Select Remote Enable Interface RS-485 Address Minimum Auto Switching Save Menu When R is selected in any above menu, or when the end is reached (after Menu 11) All program changes must start with the operation of the Menu/Execute switch and must also end with the operation of the Menu/Execute switch verified by the Save Settings? Menu. If this sequence is not followed, none of the changes will take effect. If programming is initiated and no operator action takes place for approximately 12 seconds (before the final press of the Menu/Execute switch) the display will revert to its previous status and you will need to start over. 1582-10 Manual Page 10 1/22/09

2.5 Power On Settings NOTE: THE LAST STATUS OF A UNIT IS RETAINED EVEN WHEN POWER IS REMOVED. WHEN POWER IS RESTORED, THE UNIT WILL RETURN TO IT'S PREVIOUS SETTINGS. When power is first applied, the LCD display goes through three steps. 1. The LCD goes black to show all segments are functioning. 2. The software version will be displayed. R E V 1. 0 0 3. The selected output of the switch is displayed. OUTPUT = CH1 The unit is now operational and ready for any changes the operator may desire. 2.5.1 Control Switches 1. Menu/Execute - Any change to the programming of the unit must be initiated by pressing the Menu/Execute switch and completed by pressing the Menu/Execute switch. 2. Horizontal Switch - This switch is mounted so its movement is horizontal and moves the cursor left or right. 3. Vertical Switch - This switch is mounted so its movement is vertical and has two functions: a. During frequency, gain changes, the vertical movement will raise or lower the number in the direction of the arrows. b. For other functions such Mute on/off, the vertical switch will alternately turn the function on or off regardless of the direction operated. 2.5.2 Minimum Auto Switching When minimum auto switching is enabled the switch will remain in its presently selected position unless the selected channel alarms AND the other channel is not alarmed. This mode may be desirable in situations where one of the channels is frequently coming in and out of alarm. 1582-10 Manual Page 11 1/22/09

2.5.3 Alarm Indications Power Up ON POWER UP REV 1.00 Normal Display NORMAL DISPLAY OUTPUT = CH1 PUSHING MENU/EXECUTE SEQUENCE PUSH BUTTON Menu 1 Manual Select MANUAL SELECT OFF R SCROLL <> SCROLL PUSH BUTTON Menu 2 Remote Enable REMOTE ENABLE ON R SCROLL <> SCROLL PUSH BUTTON Menu 3 Interface Select INTERFACE ETHERNET R SCROLL <> SCROLL PUSH BUTTON Menu 4 RS-484 Address ADDRESS = 00 R SCROLL <> SCROLL PUSH BUTTON Menu 5 Minimum Auto Switching MINIMUM AUTO SWITCHING = OFF R SCROLL <> SCROLL PUSH BUTTON FIGURE 2.5 Menu Display and Sequences 1582-10 Manual Page 12 1/22/09

2.6 Use Information A. Elevated operating ambient temperature - if installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack may be greater than room ambient temperature. Therefore, consideration should be given to Tmra. B. Reduced air flow - Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised. Additional space between unit may be required. C. Mechanical loading - Mounting of equipment in a rack should be such that a hazardous condition does not exist due to uneven weight distribution. D. Circuit Overloading - Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of circuits could have on over current protection and supply wiring. Appropriate consideration of equipment name plate rating should be used, when addressing this concern. E. Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connection to the Branch (use of power strips). F. Top Cover - There are no serviceable parts inside the product so, the Top Cover should not be removed. If the Top Cover is removed the ground strap and associated screw MUST BE RE-INSTALLED prior to Top Cover screw replacement. FAILURE TO DO this may cause INGRESS and/or EGRESS emission problems. 1582-10 Manual Page 13 1/22/09

CROSS TECHNOLOGIES, INC. 6170 Shiloh Road Alpharetta, Georgia 30005 (770) 886-8005 FAX (770) 886-7964 Toll Free 888-900-5588 WEB www.crosstechnologies.com E-MAIL info@crosstechnologies.com 1582-10 Manual Page 14 1/22/09