Advanced Process Functions V2.0

Similar documents
Operator Station (V8.0) SIMATIC. Process Control System PCS 7 Operator Station (V8.0) Preface 1. The PCS 7 Operator Station

SIMATIC. Process Control System PCS 7 Software update with utilization of new functions. Security information 1. Preface 2.

SIMATIC. Process Control System PCS 7 CFC Readme V9.0 (online) Security information 1. Overview 2. Notes on Installation 3. Notes on usage 4.

SIMATIC. Process control system PCS 7 Operator Station (V9.0 SP1) Security information 1. Preface 2

SIMATIC. Process Control System PCS 7 PCS 7 Documentation (V8.1) Options for Accessing Documentation 1. Documentation for the Planning Phase 2

SIMATIC. PCS 7 Process Control System CFC Readme V9.0 SP2 Upd2 (Online) Security information 1. Overview 2. Notes on Installation 3.

SIMATIC. Process Control System PCS 7 Product Brief on Software Updates from V5.1/V5.2 to PCS 7 V7.0 SP1. Preface 1

SIMATIC. Process Control System PCS 7 V7.0 SP1 Software Update With Utilization of New Functions (PCS 7 V6.x to V7.0 SP1) Preface.

Siemens Drives & PLCs

SIMATIC. Process Control System PCS 7 OS Process Control (V8.1) Preface 1. Additional documentation 2. Functions of the PCS 7 OS in process mode 3

SIMATIC. WinCC Readme Runtime Professional. Validity 1. Improvements in Update 6 2. Improvements in Update 3 3. Improvements in Update 2 4

SIMATIC. Process Control System PCS 7 OS Process Control (V8.1) Security information 1. Preface 2. Additional documentation 3

SIMATIC. TIA-Portal SIMATIC Visualization Architect. Security information 1. Basics 2. Installation 3. Elements and basic settings 4

SIMATIC HMI. WinCC V7.4 WinCC/Options for Process Control. Overview of process control system options 1. OS Project Editor 2.

SIMATIC. Process Control System PCS 7 VT Readme V8.2 (online) Security information 1. Overview 2. Notes on Installation 3. Notes on usage 4.

SIMATIC. Process control system SIMATIC BATCH Readme V8.2 (Online) Security information 1. Overview 2. Part A, Requirements and General Instructions 3

PCS 7/APACS+ OS Option Software 8.0 SP1

How Do You Replace a CPU 41x with the CPU 410-5H Process Automation? SIMATIC PCS 7 FAQ 01/2016

SIMATIC. PCS 7 Licenses and configuration limits (V9.0) Security information 1. Preface 2. Selecting the correct license keys 3

Block Library Motor Starter SIRIUS for SIMATIC PCS 7

Web Option for OS (V8.0) SIMATIC. Process Control System PCS 7 Web Option for OS (V8.0) Preface 1. Additional documentation

SIMATIC. Process Control System PCS 7 Licenses and quantity structures (V8.0) Preface 1. Selecting the correct license keys 2

SIMATIC. WinCC Readme Runtime Professional. Validity 1. Improvements in Update 2 2. Improvements in Update 1 3

Industrial Controls. SIMOCODE pro SIMOCODE pro PCS 7 Library. Preface. Security information. Product specific security. information.

SIMATIC HMI. WinCC V7.4 SP1 WinCC/Audit. WinCC/Audit - Installation Notes 1. WinCC/Audit - Release Notes 2. WinCC/Audit - Documentation.

Team engineering via Inter Project. Engineering. TIA Portal. Team engineering via Inter Project Engineering. Basics of "Inter Project Engineering"

SIMATIC. WinCC Readme Runtime Professional. Validity 1. Improvements in Update 7 2. Improvements in Update 6 3. Improvements in Update 5 4

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3 SIMATIC. Readme. Readme

SIMATIC HMI. WinCC V7.0 SP1 MDM - WinCC/Options for Process Control. Overview of process control system options 1. OS Project Editor 2.

SIMATIC. Process Control System PCS 7 Service Support and Diagnostics (V8.2) Security information 1. Preface 2. Ensuring Availability 3

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3 SIMATIC. Improvements in Openness 4. Readme. Readme

SIMATIC. PCS 7 process control system OpenPCS 7. Preface 1. Basics 2. Installation and licensing 3. PCS 7 Engineering 4. System configurations 5

SIMATIC HMI. StoragePlus V1.3 SP1 / PCS 7 V7.1 MDM - Storage Plus Information System. StoragePlus Installation Instructions 1. StoragePlus Readme 2

SIMATIC. PCS 7 process control system OpenPCS 7 (V8.2) Security information 1. Preface 2. Basics 3. Installation and licensing 4. PCS 7 Engineering 5

SIMATIC. Process Control PCS 7 V7.0 PCS 7 OS Process Control. Preface, Contents. Additional Documentation 1 Functions of the PCS 7 OS in Process Mode

SIMATIC. PCS 7/505 OS Setup Guide for V6.1. Preface, Contents. Introduction 1. Install the Software. Update a project from V6.0 to V6.

SIMATIC. Process Control System PCS 7 Trend Micro OfficeScan (V8.0; V8.0 SP1) Configuration. Using virus scanners 1.

SIMATIC. Process Historian 2014 SP2 SIMATIC Process Historian. Process Historian - Installation Notes 1. Process Historian - Release Notes

SIMATIC. Process Control System PCS 7 V7.0 Service Support and Diagnostics. Preface Contents

SIMATIC HMI. WinCC V7.4 SP1 SIMATIC HMI WinCC V7.4 Getting Started. Welcome 1. Icons 2. Creating a project. Configure communication

Service & Support. Installation guide for PCS 7 Basis Library V7.1 SP1 UPDATE 1 SIMATIC PCS 7 V7.1 SP1. SIMATIC Updates July 2010

SIMATIC. PCS 7 process control system OpenPCS 7 (V8.1) Preface 1. Basics 2. Installation and licensing 3. PCS 7 Engineering 4. System configurations 5

Creating the program. TIA Portal. SIMATIC Creating the program. Loading the block library 1. Deleting program block Main [OB1]

SIMATIC. Process Control System PCS 7 PCS 7 system documentation - Readme V8.0 SP2 (Update 1) Options for Accessing Documentation 1

SIMATIC HMI. WinCC V7.0 SP1 Setting up a Message System. WinCC Alarm Logging 1. Message System in WinCC 2. Principles of the Message System

Configuration Instruction

SFC Visualization (V8.0 SP1) SIMATIC. Process Control System PCS 7 SFC Visualization (V8.0 SP1) What's new in SFV? 1. SFC Visualization (SFV)

SIMATIC. Process Control System PCS 7 Compendium Part D - Operation and Maintenance (V8.2) Security information 1. Preface 2

SIMATIC. Process control system PCS 7 PCS 7 - PC Configuration (V9.0 SP1) Security information 1. Preface 2. PC components of a PCS 7 system 3

SIMATIC. PCS 7 Web Option for OS (V8.2) Security information 1. Preface 2. Overview of the Web Option for OS 3. Additional documentation 4

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3 SIMATIC. Readme. Readme

Readme SiVArc V14 SP1 Update 6

SIMATIC. Process Control System PCS 7 SMART PCS 7 SMART First Steps (V8.1 with APL) Preface 1. Creating the PCS 7 SMART project 2

SIMATIC. Process Control System PCS 7 Operator Station. Preface, Contents. The PCS 7 OS 1 Introduction to PCS 7 OS Configuration

SIMATIC. Process Control System PCS 7 Service support and diagnostics (V8.1 SP1) Security information 1. Preface 2. Additional support 3

PCS 7 Software Update from PCS 7 V8.1 to PCS 7 V8.1 SP 1 - Brief Instructions

SIMATIC. Process Control System PCS 7 Advanced Process Functions Engineering Manual. Preface. Security information 1. APF Engineering at a glance 2

SIMATIC. Process Control System PCS 7 Help for SIMATIC PDM (V8.1 SP1) Preface 1. Using SIMATIC PDM 2. Installation 3. PDM Exportfile Converter 4

SIMATIC. Process Control System PCS 7 Help for SIMATIC PDM (V8.0.2) Preface 1. Using SIMATIC PDM 2. Installation 3. PDM Exportfile Converter 4

SIMATIC. Process Control System PCS 7 OS Web Option (V7.1) Preface 1. Additional documentation 2. Overview of PCS 7 OS Web Option

SIMATIC. Process control system SIMATIC BATCH Readme V9.0 SP1 Update2 (Online) Security information 1. Overview 2

SIMOCODE pro. Read me SIMOCODE ES. Introduction 1. Installation notes 2. Installation/License key/ Uninstallation 3.

S7-300 Getting Started - Commissioning a CPU 31xC: Closed-loop control

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3 SIMATIC. Readme. Readme

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

SIMATIC Visualization Architect

SIMATIC. Process control system SIMATIC BATCH Readme V8.2 Update3 (Online) Security information 1. Overview 2

SIMATIC. Process Control System PCS 7 SFC Visualization (V9.0 SP2) Security information 1. What's new in SFV? 2. SFC Visualization (SFV) 3

SIMATIC. PCS 7 process control system OpenPCS 7. Preface 1. Basics 2. Installation and licensing 3. PCS 7 Engineering 4. System configurations 5

SIMATIC/SINAMICS. Getting started with SINAMICS V90 PN on S Motion Control. Fundamental safety instructions 1. Introduction

SIMATIC. Process Control System PCS 7 SMART PCS 7 SMART First Steps (V8.2 with APL) Security information 1. Preface 2

SIMATIC. SIMATIC Logon V User management and electronic signatures 1. Hardware and Software Requirements 2. Scope of delivery 3.

SIMATIC. PCS 7 process control system PCS 7 SMART (V9.0) Security information 1. Preface 2. System Requirements 3. Licenses 4

SIMATIC. Process Control System PCS 7 First Steps (V7.1) Preface 1. Creating the PCS 7 Project 2. Configuring the hardware and networks

SIMATIC. Information Server 2014 SP2 SIMATIC Information Server. Information Server - Installation Notes 1. Information Server - Release Notes

SIMATIC Automation License Manager Manual 02/2008 A5E

SIMATIC. Process Control System PCS 7 CFC for SIMATIC S7 (V9.0) Security information 1. What's new in CFC? 2. Introduction 3.

SIMATIC. Process Control System PCS 7 SIMATIC Management Console (V9.0) Security information 1. Preface 2. Basics 3

SIMATIC. Process Control System PCS 7 Advanced Process Functions Operator Manual. Preface. Security information 1. Overview 2. Material management 3

Continuous Function Chart Getting. Started SIMATIC. Process Control System PCS 7 Continuous Function Chart Getting Started.

SIMATIC. PCS 7 Process Control System SIMATIC Logon Readme V1.6 (Online) Security information 1. Overview 2. Notes on installation 3.

Optional package printer driver V1.4


SIMATIC Visualization Architect (SiVArc) Getting Started

SINUMERIK Integrate Create MyHMI / WinCC V13 SP1 SINUMERIK. SINUMERIK 840D sl SINUMERIK Integrate Create MyHMI / WinCC V13 SP1. Preface.

SIWAREX FTA PCS7. Advanced Process Library Version 12/2013

S7 Graph V 5.0 incl. Service Pack 1 Programming Software for Sequential Control Systems in SIMATIC S7

Aotewell SIMATIC S7-PDIAG for S7-300 and S Configuring Process Diagnostic Getting St

CFC for SIMATIC S7 (V8.1) SIMATIC. Process Control System PCS 7 CFC for SIMATIC S7 (V8.1) What's new in CFC? 1. Introduction 2.

Siemens Industrial SIMATIC. Process Control System PCS 7 Configuration Trend Micro OfficeScan Server XG. Security information 1.

SINEMA server SIMATIC NET. Network management SINEMA server. Preface. Network management with SINEMA Server - introduction

SIMATIC PCS 7 Minimal Configuration

SIMATIC. S7/HMI SIMATIC Automation Tool V3.1 SP1 product information. SIMATIC Automation Tool features 1. Known problems. Product Information


SIMATIC. Process Control System PCS 7 SIMATIC Management Console (V9.0 Update 1) Security information 1. Preface 2. Basics 3

SIMATIC. Process Control System PCS 7 Help for SIMATIC PDM (V9.1) Security information 1. Preface 2. Using SIMATIC PDM 3.

Getting Started - Startdrive. Startdrive SINAMICS. Introduction 1. Connecting the drive unit to the PC. Creating a project 3

SIMATIC. Industrial software WinAC RTX F Introduction 1. Selecting suitable hardware 2. Installing/removing the WinAC RTX F 2009 software

SIMATIC. ET 200SP Open Controller Product information on CPU 1515SP PC. Preface. Product Information. Technical update. Technical specifications 3


Transcription:

Advanced Process Functions V2.0 Engineering tool, function blocks and HMI library for material, parameter, storage location, job and archive management for the Process Control System SIMATIC PCS 7, enhanced job- and batch-creation via SIMATIC BATCH Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Note: Binding document All the information in this document supersedes statements in other documents. This readme file contains important information on the installation and use of Advanced Process Functions. You should therefore print out this information and read it carefully prior to installing and using the software. Security information Siemens offers IT security mechanisms for its automation and drive product portfolio in order to support the safe operation of the plant/machine. Our products are also continuously developed further with regard to IT security. We therefore recommend that you keep yourself informed about updates and upgrades for our products and always use the latest version of each product. You can find information on this at http://support.automation.siemens.com/. You can register for a productspecific newsletter here. For the safe operation of a plant/machine, however, it is also necessary to integrate the automation components into an overall IT security concept for the entire plant/machine, which corresponds to the state-of-the-art IT technology. You can find information on this at http://www.siemens.com/industrialsecurity. Products used from other manufacturers should also be taken into account here. Contents 1 Scope of supply... 3 2 Hardware requirements... 3 3 Software requirements... 3 4 Authorizations... 4 5 Installation... 4 6 Upgrade... 5 Advanced Process Functions V2.0-1- APF System Team

7 New features and changes compared to previous versions... 5 7.1 What s new in V1.4?... 5 7.2 Optimization and changes in V1.4... 6 7.3 What s new in V1.4 SP1?... 7 7.4 Optimization and changes in V1.4 SP1... 7 7.5 What s new in V1.4 SP2?... 7 7.6 What s new in V1.4 SP2 Upd1?... 8 7.7 What s new in V2.0?... 8 7.8 Optimization and changes in V2.0... 8 8 Notes on configuration and operation... 8 8.1 PCS 7 System... 8 8.2 Configuration Settings in CFC / Assigning block numbers... 8 8.3 APF Tools... 9 8.4 SIMATIC BATCH integration... 9 9 Notes for Documentation... 10 Advanced Process Functions V2.0-2- APF System Team

1 Scope of supply You have obtained the following components with this product package of Advanced Process Functions V2.0: APF Engineering Basic Package APF Runtime Package The APF (Advanced Process Functions) are a collection of software modules which supports the automation of production processes from raw material intake to release for filling and packaging. APF provide an engineering tool, predefined and generated function blocks as well as predefined HMI elements to implement the following functions: Material management Parameter management Storage location management Job management Archive management (for above mentioned functions) enhanced job- and batch-creation via SIMATIC BATCH An option of Advanced Process Functions V2.0 is the support of integration with SIMATIC BATCH (integration of material management, automatic creation of batches, dialog for enhanced job- and batch-creation). The Advanced Process Functions V2.0 are positioned as a PCS 7 based entry-level solution for small and medium plants. Because of that ISA-88 compliance is not demanded and will not be supported. APF are not positioned as replacement for an MES system. Because of that ISA-95 compliance is not demanded and will not be supported. APF are not ready for use in FDA regulated industries. 2 Hardware requirements To be able to use Advanced Process Functions V2.0, the same hardware requirements apply as for SIMATIC PCS 7 V8.1. These can be found in the document "pcs7-readme.mht" on the product DVD. The following hardware configurations are not supported with V2.0: OS Web Client Redundant single station with ES on one OS Multiple OS Servers in one PCS 7 multi-project with multiple APF servers Separate physical Server for SIMATIC BATCH and OS In addition a migration of existing APF projects from V1.4.* to V2.0 is supported. 3 Software requirements Advanced Process Functions V2.0has been released with SIMATIC PCS 7 V8.1. The Advanced Process Functions V2.0 require Windows-7 Ultimate (64 Bit) (incl. MUI), Windows Server 2008 R2 (64 Bit) incl. MUI) Advanced Process Functions V2.0-3- APF System Team

Windows-7 Ultimate (32 Bit) (incl. MUI), not possible for integration with SIMATIC BATCH WinCC option WinCC/User Archives V7.3 The Advanced Process Functions V2.0 have been tested for compatibility with the following antivirus software Trend Micro OfficeScan Client The compatibility between Advanced Process Functions V2.0 and other versions of the mentioned SW-Packages is not tested and cannot be guaranteed. Installing programs not approved by Siemens and operating them at the same time can have negative effects on the system response of Advanced Process Functions. You, as the user, are solely responsible for such effects. No additional software should be installed on runtime servers. 4 Authorizations To be able to use the APF-software on your PC, several authorizations, i.e. rights of use, are required. The authorizations are on the supplied USB data medium as ordered. You will find further information on authorizations in the documentation of Automation License Manager (ALM). The following licenses are required for APF: APF Engineering Basic Package (Floating License) APF Runtime Package (Floating License) WinCC User Archives For upgrade from Advanced Process Functions V1.4* to V2.0 are Upgrade-licenses available. The license according to the General License Conditions for Software Products for Automation and Drives for Customers with a Seat or Registered Office in Germany/outside Germany (hereinafter each "License Conditions") allows the use of the User Archives only within the use of the Add On Advanced Process Functions according to license. Siemens is not liable for any use over and beyond this limitation. Transfer of license to a third party is not permitted as independent transaction but only within transfer of rights according to the License Conditions of the Add On Advanced Process Functions. For option Integration with SIMATIC BATCH are additional SIMATIC BATCH licenses necessary. These licenses are not included on memory stick with APF license keys. 5 Installation Advanced Process Functions can only be installed with administrator rights in the operating system. Before starting the installation please close all applications. Insert the CD and start the setup program. The setup program must be executed on each computer on which APF is to be used. For use of option Integration with SIMATIC BATCH, the APF-OS-Setup must be installed on all APF clients. (It s the same setup like for OS Server. No additional licenses are necessary for APF clients.) Advanced Process Functions V2.0-4- APF System Team

6 Upgrade For an upgrade from V1.2.* to V2.0 please note: An upgrade of the Windows operating system as well as an upgrade of the PCS 7 system is required. Function blocks installed and generated prior to version V1.4 cannot be used. Generating new blocks as well as an update of the PCS 7 project is required. A detailed migration guide is available (see below). A migration must be supported by trained Siemens personnel. For an upgrade from V1.4 incl. Upd1 or Upd2 to V2.0 please note: In case of changes of the user specific functions in the directory FB_UA_USER_SPECIFIC: backup the modified functions. Delete all FB_*.fcts in the APF folder in all OS projects. (Do not delete any other files, especially no *.ini files). Run the APF Integrator in all OS projects. In case of changes of the user specific functions in the directory FB_UA_USER_SPECIFIC: restore the modified functions. If necessary, adjust the settings for PCS 7 V8.0 SP2. Open, compile and save the functions. Exchange the OS symbols in the OS projects (@Template_APF.pdl) Run the OS project editor. Update the shipped APF blocks in the master data library as well as in all AS projects by means of the Update block types function in the SIMATIC Manager. After all changes have been completed, you have to compile and download AS and OS. For the OS a full download is required. For the AS a delta download is sufficient. For an upgrade from V1.4 SP2 to V2.0 please note: An upgrade of the PCS 7 system and the project is required. A detailed migration guide is available (see below). The blocks out of STEP 7 standard library / IEC-family are now replaced by the originals. Therefore the FC-numbers must be rearranged in the project-library and the project. Because of possible collision of numbers now the UDT-numbers are moved into another range. Therefore the UDT-numbers must be rearranged in the project-library. Update the shipped APF blocks in the master data library. Run the APF Integrator in all OS projects. Run the OS project editor. Function blocks installed and generated prior to version V2.0 cannot be used. Generate new blocks via Engineering Tool. Update the APF blocks in the master data library by means of the Update block types function in the SIMATIC Manager. After all changes have been completed, you have to compile and download AS and OS. For the OS and AS a full download is required. 7 New features and changes compared to previous versions 7.1 What s new in V1.4? The APF is installed via a PCS 7 compliant setup frame. Advanced Process Functions V2.0-5- APF System Team

The APF provides a new HMI and workflow for the engineering. Configuration settings are now fully covered by the new Engineering Tool; no manual editing with an editor like notepad is required. WinCC Textlibrary IDs for APF texts edited via the engineering tool are created automatically. Compatible interface changes (for example parameter name changes without type changes) require full compile but delta download only. (Without CPU stop!) The APF Engineering Tool provides enhanced logging mechanisms for fault diagnostics during engineering. The APF function blocks generated via the Engineering Tool contain a unique version information created during engineering and block generation. This version information is available for consistency check in the ES (CFC, Process Object View) and on the OS (FB_Numbers.ini). To ensure data consistency simultaneous start of multiple instances of the Engineering Tool is prevented. Manually edited User Archive names are no longer supported; usage of existing (migrated) User Archives with names differing from the standard is possible. In APF V1.2 materials had to be created within a material type. In APF1.4 materials can be created without creating or using any types. There is only one User Archive for all material types. However, due to backward compatibility, at least one type still has to be created. The number of selectable materials in the HMI has been increased. The I/Os of the APF function blocks are available in the Process Object View. The APF support an upgrade of existing projects from V1.2.* to V1.4 Update 2. 7.2 Optimization and changes in V1.4 Best-Before-Date: Optimization in FB_BBD (change of daylight saving time). Material Management: Optimization when deleting a material, which is used in APF TP. Job Management: Prior to APF V1.4 the value assignment of the parameters OPEXTINT and QEXTINT at the block FB_JOB was swapped compared to PCS 7: - FB_JOB: 0 = extern, 1 = intern - PCS 7 Standard: 0 = intern, 1 = extern The value assignment has been aligned with the PCS 7 standard. In case of existing interconnections in the CFC, the application has to be aligned accordingly. The predefined trigger tag test have been removed from all trigger actions *0.pas. to prevent triggering all actions when creating a tag test. From V8.0 on PCS 7 allows the configuration of a standard server for User Archives (before V8.0 only for alarms and Split Screen Manager). Please note that for APF a standard server for User Archives must not be configured! FB_GetFilterAndSortValues.fct: Optimization in the standard case of user-specific function. Attention: For update, overwriting of user-specific function has to be activated in the Integrator. FB_ST_AC: New alarm added to signal the erroneous deletion of a material. FB_009PA: Optimization of display of parameter sets in the faceplate for parameter group 9. FB_ConvertUOM.fct: Optimization in the user-specific function for conversion of hl to l. Attention: For update, overwriting of user-specific function has to be activated in the Integrator. FB_STOR.pdl: display for browsing of storage locations improved. FB_STOR_ED.pdl: display of material class and process releases improved. FB_ST_AC: the output QFORMERR for format errors is now set correctly. The internal variable Redundancy_active is created automatically. The "ua" directory is created automatically in the OS project. If there are several libraries included in the multi project, the master data library will be recognized by the Engineering Tool correctly. Advanced Process Functions V2.0-6- APF System Team

New column titles for the user defined columns in runtime archives. Now the names are equal to the I/O names of the blocks. Please refer to the Engineering Manual chapter 8.3 if you generate an existing FB, because this leads one time to new column titles in the corresponding runtime table. 7.3 What s new in V1.4 SP1? Since V1.4 the function blocks generated by the Engineering Tool contain a unique version information. With V2.0 a comparison of the version information on OS and AS is executed; in case of version mismatch an error output is set. In previous versions of APF changes of classes / groups / types in the Engineering Tool have been updated only when the OS server has been loaded for the first time. For all further changes these changes had to be exported manually on the Engineering System and had to be updated manually on the OS Server. With V2.0, APF supports an automatical transfer of these changes from ES to OS in the context of the OS download; the manual alignment is obsolete. In all previous versions of the APF the names of the enumerations had to be edited manually as text in the Engineering Tool. With V2.0 a combobox is available, from which the enumerations available in the SIMATIC Manager can be selected. The APF can be operated with multiple OS Servers within one PCS 7 mutiproject; the change of the OS Server projectes is recognized by the APF Integrator. The restriction that only one OS Server can be used for the APF functions applies, which means that both the communication as well as the mapping of blocks of the APF has to be done in this server. When changing the OS Server project no cleanup takes place, scripts and User Archive remain in the old server project. In order to optimize performance of the APF Engineering Tool start sequence, the User Archive editor will no longer be started. With the installation of the APF the manuals and the online help for the function blocks are available. 7.4 Optimization and changes in V1.4 SP1 Comboboxes and multi-line text boxes have been replaced by WinCC standard objects. The STEP controls (S7actldx.dll) are no longer installed. Start the APF Integrator and download the OS; thus the APF screens and scripts on the OS Servers will be updated. In case you have used these objects in own screens, please replace them according to the APF system. Contact the customer support if necessary. The monitoring time is edited and interpreted consistently in seconds now. 7.5 What s new in V1.4 SP2? APF supports as an option the integration with SIMATIC BATCH. This allows a more comfortable recipe-system than the APF parameter- and job-management. APF still supports the Material- and Storage-management. APF provide common use of materials in APF and SIMATIC BATCH with an automatic synchronization. APF provide with a user-defined WinCC-Scripting-Interface the automatic creation, release and start of batches in SIMATIC BATCH. All necessary header-data and parameters can be given. Advanced Process Functions V2.0-7- APF System Team

7.6 What s new in V1.4 SP2 Upd1? APF supports more entries in the comboboxes. Up from 250 entries the combobox will become temporarily invisible for better performance. 7.7 What s new in V2.0? The APF licenses were switched from single to floating The APF provides a new dialog, which allows the creation of production orders and a comfortable split into batches. The orders and batches are sent to SIMATIC BATCH for further processing. The pre-selections of dialog (e.g. mode for computing number of batches and batch-size, batch-status) are set for dialog-control via WinCC-graphics-designer. The dialogfunctions can also be controlled via properties and events by user-specific scripts. 7.8 Optimization and changes in V2.0 The automatic version-check of function blocks was optimized. Optimization of changes in engineering. The integration of client-projects was optimized. The blocks out of STEP 7 standard library / IEC-family are now replaced by the originals (see upgrade hints). Because of possible collision of numbers now the UDT-numbers are moved into another range (see upgrade hints). During synchronization, APF materialclasses and types are automatically mapped to neutral folders in SIMATIC BATCH. 8 Notes on configuration and operation 8.1 PCS 7 System Make sure that for separate PCS 7 ES and OS the setting Permit activation on ES in the WinCC project properties / Options tab is disabled. Having this setting enabled may result in corrupt APF user archive data (Refer also to Customer Support FAQ ID 24285161). Selective download (CFC editor): This SIMATIC PCS 7 function has been designed for "continuous systems" and cannot be used in conjunction with APF. 8.2 Configuration Settings in CFC / Assigning block numbers The following FB/FC- block number ranges are reserved for the Advanced Process Functions V2.0 (and predecessor versions) and must be excluded for use by application block numbers as well as CFC/SFC compiler output (instance DBs, runtime group FC's, SFC-Types etc.): FB 1775 FB 1800 FB 2080 FB 2085 FC 1775 The Engineering Tool will generate project specific FBs. The management of these block numbers can be configured via the Engineering Tool and is in the responsibility of the user. They must not overlap with the above mentioned ranges. Advanced Process Functions V2.0-8- APF System Team

8.3 APF Tools On change of an FB number of a previously compiled material class (e.g. FB_001A FB-Nr. 201 to 1201), the SCL compile will fail because the symbolic name in PCS 7 symbol table cannot be created / changed. Workaround: Please open the symbol editor and delete the old symbol for the corresponding FB number. The APF Engineering Tool creates FB I/Os based on the names specified in the Engineering Tool; in some cases these names may be in conflict with SCL variables used internally, i.e. the name / identifier is already in use. Workaround: Please use a different name in the Engineering Tool. Hint: please use self-explanatory names. With APF it is possible to create material lots from the PLC application. These S7 strings can contain quotes, double quotes and other special characters, e.g. XLOT"1OS1, which are not allowed as characters in the PCS 7 OS and User Archives. These names are not accessible, i.e. they cannot be displayed or deleted in the OS. Please ensure that the PLC application respects conventions for invalid special characters in the PCS 7 OS as well. The APF dummy FBs required for FB generation remain in the master data library after compiling / creating FBs. Every time when generating an FB a message appears: do you want to overwrite FB xxx?. This message can be acknowledged with yes like the following message which asks for the permission to overwrite an existing block, which should always be answered with yes. After re-sorting the job list in the HMI the external deletion of jobs via FB_JOB still works correct, but in the message text a wrong job name may be displayed. Due to backward compatibility it is not possible to delete the following objects in the Engineering Tool: - Material classes - Material types - Parameter groups - Archive groups Storage management: APF provides typicals for the search of storage locations and materials in @PCS7TypicalsAPF.pdl with option /2. In manual mode they can open the faceplate automatically, if the selection of a storage location is required. However, after each compiling the trigger names must be completed accordingly via Properties Miscellaneous OpenFaceplate (e.g. from.qman_out to FB_STLOC/FB_STLOC.QMAN_OUT ). PCS 7 enumerations used by the APF must not start with value 0. Windows local settings have to be set consistently prior to APF engineering on all PC stations within the PCS 7 multiproject incl. the ES and must not be changed during the engineering. It is also recommended not to make changes afterwards. The APF support OS Single Stations. It is generally recommended, not to install the PCS 7 ES on the PCS 7 OS Server (the actual OS Single Station), but to use a separate PC Station. In case ES and OS are installed on one PC Station, please pay attention that the OS runtime is not active during an APF engineering session. The APF Engineering Tool prevents saving data when OS Runtime is active. To avoid inconsistent master data in APF, do not modify them at the same time on different OS clients. 8.4 SIMATIC BATCH integration If during transmission of data from APF to SIMATIC BATCH a switch between redundant server or a reboot of the SIMATIC BATCH server occurs, rarely a reboot of WinCC graphics runtime could be necessary. Advanced Process Functions V2.0-9- APF System Team

The mapping of APF materialclasses and types to neutral folders in SIMATIC BATCH works only up to 16 characters. 9 Notes for Documentation The APF documentation consists of the following documents: Installation and configuration Engineering manual Function manual Operator manual SIMATIC BATCH Integration The documentation is contained on the product CD V2.0and is also available on our customer support page. http://support.automation.siemens.com/ww/view/en/102952599/130000 For the migration from APF V1.2.*/1.4.* to APF V2.0 a migration guide is available for download on our customer support pages Advanced Process Functions V2.0-10- APF System Team