SIMATIC. WinCC Readme Runtime Professional. Validity 1. Improvements in Update 2 2. Improvements in Update 1 3

Similar documents
SIMATIC. WinCC Readme Runtime Professional. Validity 1. Improvements in Update 7 2. Improvements in Update 6 3. Improvements in Update 5 4

Readme SiVArc V14 SP1 Update 6

Team engineering via Inter Project. Engineering. TIA Portal. Team engineering via Inter Project Engineering. Basics of "Inter Project Engineering"

SIMATIC. Process Control System PCS 7 VT Readme V8.2 (online) Security information 1. Overview 2. Notes on Installation 3. Notes on usage 4.

Creating the program. TIA Portal. SIMATIC Creating the program. Loading the block library 1. Deleting program block Main [OB1]

SIMATIC. Process Control System PCS 7 PCS 7 system documentation - Readme V8.0 SP2 (Update 1) Options for Accessing Documentation 1

MindSphere. Visual Explorer. Introduction. User roles for "Visual Explorer" Connecting "Visual Explorer" to MindSphere data. Creating Visualizations

SIMATIC. Process Control System PCS 7 Licenses and quantity structures (V8.0) Preface 1. Selecting the correct license keys 2

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3 SIMATIC. Readme. Readme

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3 SIMATIC. Readme. Readme

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3 SIMATIC. Improvements in Openness 4. Readme. Readme

Class documentation. COMOSKDictionary COMOS. Platform Class documentation COMOSKDictionary. Trademarks. General. KDictionary. Programming Manual

COMOS. Platform Class documentation RevisionMaster_dll. Class: RevisionInfo 1. Class: RevisionMaster 2. Programming Manual

Performance data abgn SCALANCE W770/W730 SIMATIC NET. Industrial Wireless LAN Performance data abgn SCALANCE W770/W730.

SIMATIC. WinCC Readme Runtime Professional. Validity 1. Improvements in Update 6 2. Improvements in Update 3 3. Improvements in Update 2 4

Performance data abgn PCIe Minicard MPCIE-R1-ABGN-U3 SIMATIC NET

PD PA AP How To Configure Maxum II TimeServer Access

SIMATIC. S7/HMI SIMATIC Automation Tool V3.1 SP1 product information. SIMATIC Automation Tool features 1. Known problems. Product Information

SIMATIC. PCS 7 Process Control System SIMATIC Logon Readme V1.6 (Online) Security information 1. Overview 2. Notes on installation 3.

Configuration limits for products of the SIMATIC NET PC Software V8.1 SIMATIC NET

SIMATIC HMI. WinCC V7.4 SP1 SIMATIC HMI WinCC V7.4 Getting Started. Welcome 1. Icons 2. Creating a project. Configure communication

Siemens Drives & PLCs

SIMATIC. Process control system PCS 7 Operator Station (V9.0 SP1) Security information 1. Preface 2

SIMATIC. Process Control System PCS 7 Trend Micro OfficeScan (V8.0; V8.0 SP1) Configuration. Using virus scanners 1.

SIMATIC. Process Historian 2014 SP2 SIMATIC Process Historian. Process Historian - Installation Notes 1. Process Historian - Release Notes

SIMATIC. Process Control System PCS 7 Configuration McAfee Endpoint Security Security information 1. Preface 2.

SIMATIC. Process Control System PCS 7 PCS 7 Documentation (V8.1) Options for Accessing Documentation 1. Documentation for the Planning Phase 2

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

Optional package printer driver V1.4

Configuration limits for products of the HARDNET-PB DP-Base 1

RF-MANAGER simulator SIMATIC. RFID-Systems RF-MANAGER simulator. Simulating projects. Compact Operating Instructions 06/2010 A5E

Operator Station (V8.0) SIMATIC. Process Control System PCS 7 Operator Station (V8.0) Preface 1. The PCS 7 Operator Station

SIMATIC. Process Control System PCS 7 OS Process Control (V8.1) Security information 1. Preface 2. Additional documentation 3

Process Historian Administration SIMATIC. Process Historian V8.0 Update 1 Process Historian Administration. Basics 1. Hardware configuration 2

SINEMA Remote Connect - Client SIMATIC NET. Industrial Remote Communication SINEMA Remote Connect - Client. Preface. Requirements for operation

SIMATIC. Process Control System PCS 7 OS Process Control (V8.1) Preface 1. Additional documentation 2. Functions of the PCS 7 OS in process mode 3

SIMATIC HMI. WinCC V7.4 WinCC/Options for Process Control. Overview of process control system options 1. OS Project Editor 2.

SIMATIC. PCS 7 Licenses and configuration limits (V9.0) Security information 1. Preface 2. Selecting the correct license keys 3

SIMATIC. Process Control System PCS 7 Advanced Process Functions Operator Manual. Preface. Security information 1. Overview 2. Material management 3

B.Data V6.0 Installation SIMATIC. B.Data V6.0 Installation. Introduction. Installing B.Data. Setting up B.Data Web 3

party software COMOS Platform Third-party software Trademarks 1 Requirements for the system environment Third-party software releases Operating Manual

Key Panels Library SIMATIC HMI. Key Panels Library. Preface 1. Installation of Key Panels Library. Working with the Key Panels Library

SIMATIC. Process Control System PCS 7 Symantec Endpoint Protection 11.0 Configuration. Using virus scanners 1. Configuration 2. Commissioning Manual

Class: DocumentManager 1 COMOS. Platform Class documentation DocumentManager_dll. Programming Manual 03/2017 V10.2.

MindSphere. MindConnect IoT Extension Getting Started. Introduction to MindSphere. Prerequisites 2. Preparations 3. MindConnect IoT Extension

Getting Started - Startdrive. Startdrive SINAMICS. Introduction 1. Connecting the drive unit to the PC. Creating a project 3

SIMATIC. Process Control System PCS 7 CFC Readme V9.0 (online) Security information 1. Overview 2. Notes on Installation 3. Notes on usage 4.

Siemens Industrial SIMATIC. Process Control System PCS 7 Configuration Trend Micro OfficeScan Server XG. Security information 1.

SIMATIC NET. S TeleControl MSC300_Library program block library. Block library for TCSB (V3) WDC_S7_300_... (FB92) 2 UDT_WDC_PARAM (UDT91) 3

SIMATIC NET. Industrial Remote Communication - Remote Networks SINEMA Remote Connect - Client. Preface. Requirements for operation 1

Deckblatt. APL Operator Guide SIMATIC PCS 7. Application description June Applikationen & Tools. Answers for industry.

SIMATIC. STEP 7 PLUS TIA Portal Teamcenter Gateway. Introduction to TIA Portal Teamcenter Gateway 1. System requirements 2

B.Data V6.0 SP1 Installation SIMATIC. B.Data V6.0 SP1 Installation. Introduction 1. Installing B.Data. Setting up B.Data Web

SIMOTION. Motion Control Task Trace. Preface 1. Overview 2. Configuring 3. Working with the SIMOTION Task Profiler 4.


S7-300 Getting Started - Commissioning a CPU 31xC: Closed-loop control

SIMATIC IPC Wizard for. Widescreen devices with multitouch SIMATIC. Industrial PC SIMATIC IPC Wizard for. Preface.

SITOP UPS1600 under STEP 7 V13. SITOP UPS1600 under STEP 7 V13. Introduction. Safety notes. Description. Assigning the IP address

SIMATIC Ident RFID systems MDS D423 Compact Operating Instructions

Class: POptions 1 COMOS. Platform Class documentation POptions_dll. Programming Manual 04/2014 A5E AA

SIMATIC. Information Server 2014 SP2 SIMATIC Information Server. Information Server - Installation Notes 1. Information Server - Release Notes

SIMATIC. Process control system PCS 7 PCS 7 - PC Configuration (V9.0 SP1) Security information 1. Preface 2. PC components of a PCS 7 system 3

SIMOCODE pro. Read me SIMOCODE ES. Introduction 1. Installation notes 2. Installation/License key/ Uninstallation 3.

Web Option for OS (V8.0) SIMATIC. Process Control System PCS 7 Web Option for OS (V8.0) Preface 1. Additional documentation

SIMATIC. PCS 7 Web Option for OS (V8.2) Security information 1. Preface 2. Overview of the Web Option for OS 3. Additional documentation 4

SIMATIC. TIA-Portal SIMATIC Visualization Architect. Security information 1. Basics 2. Installation 3. Elements and basic settings 4

SIMATIC. ET 200SP Open Controller Product information on CPU 1515SP PC. Preface. Product Information. Technical update. Technical specifications 3

SIMATIC. Process Control System PCS 7 Product Brief on Software Updates from V5.1/V5.2 to PCS 7 V7.0 SP1. Preface 1

Primary Setup Tool (PST) SIMATIC NET. Industrial Ethernet / PROFINET Primary Setup Tool (PST) Preface. Description. Software installation 2

SIMATIC. Process Control System PCS 7 Software update with utilization of new functions. Security information 1. Preface 2.

MindSphere. Fleet Manager. Introduction to "Fleet Manager" 1. User interface for "Fleet Manager" 2. User rights in "Fleet Manager" 3.

SIMATIC. Industrial software WinAC RTX F Introduction 1. Selecting suitable hardware 2. Installing/removing the WinAC RTX F 2009 software

MindSphere. Fleet Manager. Introduction to "Fleet Manager" 1. User interface for "Fleet Manager" 2. User rights in "Fleet Manager" 3

SITOP UPS1600 under STEP 7 V5. SITOP UPS1600 under STEP 7 V5. Introduction. Safety notes. Description 3. Assigning the IP address

ET 200S distributed I/O system 4DO DC24V/2A ST digital electronic module (6ES7132-4BD32-0AA0)

SIMATIC. Process Control System PCS 7 Configuration Symantec Endpoint Protection V14. Security information 1. Preface 2.

SIMATIC. PCS 7 process control system OpenPCS 7 (V8.2) Security information 1. Preface 2. Basics 3. Installation and licensing 4. PCS 7 Engineering 5

SIMATIC HMI. WinCC V7.0 SP1 MDM - WinCC/Options for Process Control. Overview of process control system options 1. OS Project Editor 2.

General Information 1. Connection 2. User Interface 3 ATC5300. Menus 4. Automatic Transfer Controller. Remote Control Software Manual A5E

SIMATIC. SIMATIC Logon V User management and electronic signatures 1. Hardware and Software Requirements 2. Scope of delivery 3.

Setting up securityglobal FW Rulesets SIMATIC NET. Industrial Ethernet Security Setting up security. Preface. Firewall in standard mode

SIMATIC NET. Industrial Ethernet / PROFINET Primary Setup Tool (PST) Preface. Functions 1. Software installation 2. Operation. Configuration Manual

SIMATIC. SIMATIC Energy Manager V1.0 App for ios and Android. Preface. SIMATIC Energy Manager app. Establish connection to SIMATIC Energy Manager PRO

Scope and Purpose of this. Guideline. Requirements. Limitations. MindSphere. Testing. MindConnect LIB Developer. Branding.

Industrial Controls. Motor management and control devices SIMOCODE pro - Application examples. Introduction 1. Application example

Siemens Spares. Setting up security in STEP 7. Professional SIMATIC NET. Industrial Ethernet Security Setting up security in STEP 7 Professional

Use with 0 to 70 C ambient. temperature SIMATIC. Process Control System PCS 7 Use with 0 to 70 C ambient temperature. Preface 1. Product combination 2

Settings. Prior information notice 1. Introduction to "Settings" 2. User rights in "Settings" 3. Settings interface 4.

DI 8x24VDC ST digital input module SIMATIC. ET 200SP DI 8x24VDC ST digital input module (6ES7131-6BF00-0BA0) Preface. Documentation guide

Siemens Automation Products

SIMATIC HMI. WinCC V7.0 SP1 Setting up a Message System. WinCC Alarm Logging 1. Message System in WinCC 2. Principles of the Message System

Examples for SIMATIC IPC Support. Package for VxWorks SIMATIC. Industrial PC Examples for SIMATIC IPC Support Package for VxWorks

Block Library Motor Starter SIRIUS for SIMATIC PCS 7

Siemens SIMATIC. Process Control System PCS 7 OPC A&E for PCS 7 (V7.1) OPC A&E server with hierarchical access for use in PCS 7

COMOS. Operations Inspection. Introduction 1. Working with the "Inspection" plugin 2. Working with the "Inspection diagram" plugin 3

Siemens Spares COMOS. Operations Inspection. Introduction 1. Working with the "Inspection" plugin 2. Working with the "Inspection diagram" plugin 3

SIMATIC HMI. WinCC WinCC Runtime Advanced readme. Security information 1. Installation 2. Runtime 3. System Manual. Online help printout

BaseUnits (6ES7193-6BP.../3RK1908-0AP00 ) SIMATIC. ET 200SP BaseUnits. Preface. Guide to the documentation 1. Product overview 2

SIMATIC. PCS 7 process control system OpenPCS 7 (V8.1) Preface 1. Basics 2. Installation and licensing 3. PCS 7 Engineering 4. System configurations 5

SFC Visualization (V8.0 SP1) SIMATIC. Process Control System PCS 7 SFC Visualization (V8.0 SP1) What's new in SFV? 1. SFC Visualization (SFV)

Transcription:

Validity 1 Improvements in Update 2 2 SIMATIC WinCC Improvements in Update 1 3 Performance features of Runtime Professional 4 Readme 03/2017

Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION indicates that minor personal injury can result if proper precautions are not taken. NOTICE indicates that property damage can result if proper precautions are not taken. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems. Proper use of Siemens products Note the following: Trademarks WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed. All names identified by are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens AG Division Digital Factory Postfach 48 48 90026 NÜRNBERG GERMANY P 07/2017 Subject to change Copyright Siemens AG 2016. All rights reserved

Table of contents 1 Validity...5 2 Improvements in Update 2...7 3 Improvements in Update 1...9 4 Performance features of Runtime Professional...11 4.1 WinCC Runtime Professional...11 4.2 Orientation help for performance in Runtime (WinCC Runtime Professional)...15 4.3 Orientation help for communication in Runtime (WinCC Runtime Professional)...17 Index...21 Readme, 03/2017 3

Table of contents 4 Readme, 03/2017

Validity 1 Validity This update is valid for the following products: WinCC Runtime Professional V14 SP1 Note If you modify your system after installing the update with the product DVD, you will have to perform the update again. Windows 7 / Windows Server 2008 R2: Invalid certificate validation The new certificates used for signing may possibly not be validated on the Windows 7 and Windows Server 2008 R2 operating systems. If you do not have the possibility to update the certificate store online, the signature of the product files is displayed as invalid. In this case, update the root certificates provided by Microsoft on the offline systems. To do so, follow the instructions in FAQ 109748887 (https:// support.industry.siemens.com/cs/ww/en/view/109748887). Readme, 03/2017 5

Validity 6 Readme, 03/2017

Improvements in Update 2 2 Update 2 contains the following improvements and changes: Certificates for OPC UA client If installing for the first time, the instance certificates are generated with Sha256 and the key length 2048. If installing the update in an existing OPC UA environment, the existing Sha1 certificates are reused. If it is necessary to use certificates signed with Sha256, the existing certificates must be manually replaced. To do so, proceed as follows: 1. Delete or move the existing certificates and keys from the PKI directories: \WinCC\opc\UAClient\PKI\OPCUA\certs \WinCC\opc\UAClient\PKI\OPCUA\private 2. Generate new certificates. To do so, open the command line with administrator rights and execute the following commands: \WinCC\opc\UAClient\UaConfigServer\CCOpcUaImporter.exe /CreateCertificate \WinCC\opc\UAClient\UaDAS\CcUaDAS.exe /CreateCertificate 3. Distribute the new certificates to the connected servers (trust list). Screens and screen objects The functionality of the system diagnostics display has been improved. A change to the configured tags in an animation affects all of the selected objects. Tags A configured deadband is also taken into account with the acquisition mode "On change". VBS functions The"ActiveScreen" method returns a correct result even if a pop-up screen is displayed. Communication Communication via OPC UA has been improved. See also FAQ (https://support.industry.siemens.com/cs/ww/en/view/109748887) Readme, 03/2017 7

Improvements in Update 2 8 Readme, 03/2017

Improvements in Update 1 3 Update 1 contains the following improvements and changes: Screens and screen objects in Runtime The function of the object "ProDiag overview" has been improved. The function of the object "Media Player" has been improved. Communication Communication to S7 1500 has been improved. Readme, 03/2017 9

Improvements in Update 1 10 Readme, 03/2017

Performance features of Runtime Professional 4 4.1 WinCC Runtime Professional WinCC Runtime Professional The following tables of system limits help you assess whether your project conforms to the system limits of a given HMI device. The specified maximum values are not additive. It cannot be guaranteed that configurations running on the devices at the full system limits will be functional. In addition to the specified limits, allowances must be made for restrictions imposed by configuration memory resources. Tags WinCC Runtime Professional Number of tags in the project 250,000 Number of PowerTags Depends on the license Number of elements per array 2,000 Screens Objects per screen 1) No limit 2) Layers per screen 32 Screens per project No limit 2) WinCC Runtime Professional Screen size in pixels 10,000 x 10,000 Screen object nesting 20 Number of colors 24-bit color depth, 8-bit alpha channel for transparency 1) The number and complexity of objects affects performance 2) Limited by system resources. Readme, 03/2017 11

Performance features of Runtime Professional 4.1 WinCC Runtime Professional Alarms WinCC Runtime Professional Configurable alarms per server/single-user station 150,000 Process tags per alarm line 10 User text blocks per alarm line 10 Alarm classes 256 Alarm priorities 17 (0...16) Alarms in Runtime Maximum Alarms per alarm log No limit 1) Alarms per historical alarm list (short-term) 1,000 Alarms per historical alarm list (long-term) 1,000 2) Alarms per alarm view 5,000 3) 1) Limited by system resources. 2) On single-user station, or server or client per server if "LongTimeArchiveConsistency" has been set to "no". On single-user station, server, or client if "LongTimeArchiveConsistency" has been set to "yes". 3) On single-user station or server, or on client per server. Note Message bursts and continuous alarm load may be generated simultaneously on a single-user station or server. Logs WinCC Runtime Professional Trend view per screen 25 Trends per trend view 80 Table view per screen 25 Columns per table view 12 Values per table view 30,000 Logs per single-user station/server 100 Logging tags per single-user station/server 1) 80,000 1) Depends on the Logging PowerPack used for logging tags. The basic version contains 500 logging tags. 12 Readme, 03/2017

Performance features of Runtime Professional 4.1 WinCC Runtime Professional Note Screen selection times may be extremely long in the event of multiple maximum values. Recipes WinCC Runtime Professional Number of recipes No limit Number of recipe elements 1) 500 Number of recipe data records 10,000 Number of views No limit 1) Maximum 1,000,000 recipe elements in total Example of a permissible configuration limit in Runtime You reach the maximum number of 1,000,000 recipe elements, for example, with the following configurations: 10,000 recipe data records each with 100 recipe elements 2,000 recipe data records each with 500 recipe elements Assumption: Each recipe element is connected to a tag. Keep in mind that such configuration limits are also influenced by the hardware used and by other configurations. Reports WinCC Runtime Professional Configurable reports No limit 1) Report lines per detail view 66 Tags per report 2) 300 1) Limited by system resources. 2) The number of tags per report depends on the performance of process communication. Reports in runtime Maximum Alarm sequence reports running simultaneously per server/client 1 Alarm log reports running simultaneously 3 Readme, 03/2017 13

Performance features of Runtime Professional 4.1 WinCC Runtime Professional User management Number of users 128 Maximum Communication S7-1200 S7-1511 S7-1513 S7-1516 S7-1518 Maximum number of WinCC system 2 20 30 41 62 ISO-on-TCP connections - 64, 4 of which are reserved for ES 96, 4 of which are reserved for ES 128, 4 of which are reserved for ES 192, 4 of which are reserved for ES Maximum number of connected PLCs per Runtime 64 Maximum number of connected PLCs with Softnet via a network adapter 64 Note that a maximum of 200 tags per controller should be configured for communication with S7-1200 PLCs. If several HMI devices access a PLC, this limit applies for all HMI devices. You can learn how many HMI devices can simultaneously access a SIMATIC S7-1200 in the manual for the controller. Entry ID: 36932465 Configurations - configuration limits in the multi-station system WinCC Runtime Professional WinCC clients in a system 32 Web clients in a system 150 1) 2) 2) 3) 1) The number of clients is reduced to four if the server also used as operator station. 2) Mixed configuration: 32 clients + 3 Web clients 3) Mixed configuration: 50 Web clients + 1 WinCC client 14 Readme, 03/2017

Performance features of Runtime Professional 4.2 Orientation help for performance in Runtime (WinCC Runtime Professional) 4.2 Orientation help for performance in Runtime (WinCC Runtime Professional) WinCC Runtime Professional The following tables help you to assess operational performance of your project in Runtime. Note The values specified greatly depend on the hardware used. Screens in Runtime Screen change from an empty screen to... Time in seconds Screen with standard objects (100 objects) 1 Screen with 2480 I/O fields (8 internal tags) 2 Screen with 1000 I/O fields (1000 internal tags) 1 10 MB screen (bitmap) 1 Alarm view 2 Table view with 4 columns, each with 120 values 1) 1 1) The values specified are valid for data from "Tag Logging Fast". Alarms in Runtime Maximum Continuous alarm load without losses (single-user station/server) 10/sec Message burst (single-user station/server) 2000/10 seconds at intervals of 5 minutes 1) 1) Alarms are possibly lost if the interval before the next message burst is less than five minutes. Note Message bursts and continuous alarm load may be generated simultaneously on a single-user station or server. Readme, 03/2017 15

Performance features of Runtime Professional 4.2 Orientation help for performance in Runtime (WinCC Runtime Professional) Logs in runtime Maximum Logging in database for server/single-user station (Tag Logging Fast) 5000 values/second 1) Logging in database for server/single-user station (Tag Logging Slow) 1000 values/second Number of values printed in a report 1) 2) The number of values printed depends on the number of values displayed in the trend view. 1) The values specified are valid for logging data without signature. 2) With Tag Logging Slow, expect longer screen selection times for a given amount of data than for Tag Logging Fast. Recipes in Runtime - boundary conditions Hardware used Software used Configuration Intel Core i3-6100u 2.30 GHz 4 GB RAM No hardware connection Windows 7 WinCC V14.0 SP1 One WinCC tag per field 300,000 entries each: - 10 fields with 30,000 data records - 500 fields with 600 data records Recipes in Runtime - measured values Screen change to a screen with integrated recipe view. Result of measurement depends on the fill level of the control: It can take up to 15 seconds for complete display upon initial loading or if considerable configuration changes are made in the user log. Read data record: Read the value to the corresponding tag after the button in the recipe view was clicked. Write data record: Write the value to the corresponding tag and display of the tag in the I/O field after the button in the recipe view was clicked. 10 fields 500 fields 1 second 5 seconds 1-2 seconds 1) n seconds 2) 1-3 seconds 1) n seconds 2) Focus change from the first to the last data record. 1-2 seconds 1-2 seconds 1) 10 fields with a total of 10 tags. 2) 500 fields with a total of 500 tags. 16 Readme, 03/2017

Performance features of Runtime Professional 4.3 Orientation help for communication in Runtime (WinCC Runtime Professional) Reports in runtime Maximum Alarm sequence reports running simultaneously per server/client 1 Alarm log reports running simultaneously 3 4.3 Orientation help for communication in Runtime (WinCC Runtime Professional) WinCC Runtime Professional Install the SIMATIC NET software from the supplied DVD. To use WinCC Runtime Professional with a S7-1200 / S7-1500 controller, you must not exceed the specific system limitations for the corresponding S7 controller. The following explains the system limits for tags, whose values are reported by an S7-1200/S7-1500. The "WinCC Channel Diagnosis" tool is used to make the determination. Note Refer to the parameter tables for the specific system limits of your S7-1200 / S7-1500 controller. Attributes Attribute Plc Attributes (max) Minimum Plc Attributes (free) Number WinCC Runtime Professional Description This value refers to the maximum number of tags that can be read cyclically. By default, the communication load of an S7 controller is not configured under 30% (default value: 50%). The "Minimum Plc Attributes (free)" value is based on empirical values. The value applies to the steady state with no screen change. The minimum number Minimum Plc Attributes (free)" "may be temporarily lower. If the number approaches 0, cyclic reading with low cycle times begins, briefly slowing down communication with the S7 controller. The "Number WinCC Runtime Professional" indicates the maximum number of WinCC Runtime Professional systems which can be connected to a S7 controller. The number includes a WinCC ES that is connected to the S7 controller. Note "Plc Attributes" can be used by one or more WinCC Runtime systems. The number of concurrent tags of all connected WinCC Runtime systems for each S7 controller therefore needs to be added up. You can learn how to determine the number of concurrent tags in the section "Critical factors of concurrent tags". Readme, 03/2017 17

Performance features of Runtime Professional 4.3 Orientation help for communication in Runtime (WinCC Runtime Professional) Example Note To ensure stable communication with the S7 controller, you should not exceed the "Number of concurrent tags per S7". You can read the values for the "Plc Attributes (max)", "Minimum Plc Attributes (free)" columns of the parameter table from the WinCC Channel Diagnosis Tool under "CCS7PLUSCHANNEL" and the corresponding connection. The number of concurrent tags per S7 controller can be determined from the "Plc Tag Subscriptions" counter: The number of registered tags per cycle time is displayed. In the following example, the number of registered tags is 2003 (500 ms: 103 tags, 1 s: 400 tags, 2 s: 500 tags, 5 s: 1000 tags). Critical factors of concurrent tags The number of concurrent tags can be obtained from the following table. Cycle times less than 5 seconds are relevant here. Generally, only the tags which are detected by an S7 controller are relevant. In the example above, these are the tags of the "PLC1516" connection. Functionality Archiving HMI alarms Scheduler Concurrent tags Sum of all tags per acquisition cycle. Number tags for discrete alarms + number tags for analog alarms + number associated values from tags per alarm. Sum of all unused tags per cyclic event. With SmartTags, only the Smart Tags with cache usage are relevant. Number of trigger tags used. 18 Readme, 03/2017

Performance features of Runtime Professional 4.3 Orientation help for communication in Runtime (WinCC Runtime Professional) Functionality Scripts Screen OPC server (DA / UA) Control Development Concurrent tags This affects cyclic scripts, specifically the functions within that use a cache. Information about using the cache is provided in the documentation. Examples: HmiRuntime.Tags().Read 0. SmartTags when using the cache. All affected tags are included in the count. Number of tags directly related to object properties. Number tags used directly in controls with cycles (for example, gauge control, trend views, table views). Number of tags used in cyclic animations, C scripts, VB scripts. Number of trigger tags used. Sum of all cyclically reported items. Sum of all cyclically read tags. Readme, 03/2017 19

Performance features of Runtime Professional 4.3 Orientation help for communication in Runtime (WinCC Runtime Professional) 20 Readme, 03/2017

Index H HMI device Performance features, 11 WinCC Runtime Professional performance, 15 P Performance features HMI device, 11 WinCC Runtime Professional, 11 WinCC Runtime Professional performance, 15 Readme, 03/2017 21

Index 22 Readme, 03/2017