D-Link Switch User Manual. Table of Contents

Similar documents
TE100-S16 16-Port 10/100Mbps Fast Ethernet Switch. User s Guide

TEG-S224TX 26-Port 10/100/1000Mbps Gigabit & Fast Ethernet Switch

8-PORT GIGABIT UNMANAGED DESKTOP SWITCH DGS-1008P QUICK INSTALLATION GUIDE

ST-POEAF-S16-RM. 16 port PoE switch. User Guide

LevelOne FSW PoE Fast Ethernet Switch User Manual

TE100-DX16R/DX24R/DX32R 16/24/32 Ports Ethernet/Fast Ethernet Dual-Speed Stackable Hubs User s Guide

GEU Port Gigabit Switch

FSW-1609TFX FSW-2409TFX

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

EZ Switch EZ Connect N SMCFS1601/SMCFS2401

User Guide TL-SG1024D 24-Port Gigabit Desktop/Rackmount Switch

5-Port 1000BASE-T. Gigabit Ethernet Switch. User s Guide

FSW-1610TX FSW-2410TX

100 - SERIES NETWORK SWITCHES QUICK START GUIDE

GEU-0520 GEU QIG Manual

USER GUIDE. EZ Switch TM 10/100 16/24-Port Unmanaged Fast Ethernet Switches SMCFS1601/SMCFS2401

24-Port Gigabit Ethernet Switches

AS1008-P AS1026-P AS2008-P AS2024-P User Manual

Ether-FSH2400C 24-port 10/100Base-TX Switch

USER GUIDE. EZ Switch TM 10/100/ G Port Unmanaged Fast Ethernet Switch SMCFS2601

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

300 - SERIES NETWORK SWITCHES QUICK START GUIDE

8 ports 10/100/1000Mbps. Gigabit Ethernet Desktop Switch Layer 2 USER S GUIDE

8-port 10/100TX + 2-Port 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors Industrial Ethernet Switch User Manual

10/100/1000Mbps. Gigabit Ethernet Switch GSW-2401/GSW User's Manual

5/8-Port Industrial Fast Ethernet Switch ISW-500/ISW-800. User's Manual

Micro-Switch/ port 10/100Mbps. Desktop Fast Ethernet Switch. (Auto MDI/MDIX) FEP T- 3 USER S MANUAL

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

LevelOne. User s Guide EHU-0507T EHU-0507TB EHU-0807T EHU-0907TB. 5/8/9 Port PalmCon 10M HUB

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

Lantech. IPGS-0005T /100/1000T PoE at T Industrial Unmanaged Switch. User Manual

MS400870M. User's Guide. Ver.: Port GBE SFP Switch 19 1U 24x10/100/1000T Combo 10/1000X SFP

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

DynaGST/2402G USER S MANUAL

pakedgedevice&software inc.

Hypercable injecteur HPOE - Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail :

User Guide TL-SG1005D TL-SG1008D. 5/8-Port Gigabit Desktop Switch. alarm shop. Rev:

GSW-2453 Gigabit Chassis switch. User Guide

DynaGST/2402G. 24 Port 10/100/1000Base-T Gigabit Ethernet Switch with two SFP (mini) GBIC Slots PN: GEP-33224T USER S MANUAL

FCC Certifications. CE Mark Warning

Lantech. IPGS-0204DSFP 4 10/100/1000T PoE at/af + 2 Dual Speed SFP Industrial Unmanaged Switch

24-Port 10/100Mbps + 2-Port. Gigabit Ethernet Switch FGSW User s Manual

AT-GS950/16 AT-GS950/24

LevelOne. User Manual GSW-1656/GSW /24-Port Gigabit Switch w/ 4-Port SFP. Version

BLACKBOX NETWORK SERVICES. one source for worldwide infrastructure services

GSW-1657 GSW User's Guide. 16/24-port Gigabit Ethernet Switch. Ver

MARQUE: TP-LINK REFERENCE: TPL_TLSF1016D CODIC:

MIL-S24002TGxx. 24-port 10/100/1000 TX 2 Combo SFP Slots Unmanaged Switch. User Guide

5/8-Port 10/100Mbps Fast Ethernet Desktop Switch

8-Port PoE Network Switch. PoE ACT ACT/LINK. 8-Port 10/100Base-T Switch with 8-Port PoE Ethernet Switch

High-Power Unmanaged PoE Switch with LCD Status Display. Power over Ethernet 802.3at. Innovative LCD Status Display

SWITCH, 24 POE PORTS ART. IPSWP240A

6 10/100/1000TX + 2G Fiber Industrial Ethernet Switch User Manual

10/100Base-TX to 100Base-TX Mini Converter. Operation Manual

LNP series. 5-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 1*10/100Tx, 12~36VDC Input.

16 / 24 Ports Fast Ethernet Switches 19 Rackmount Quick Installation Guide

IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual

OV-MCR116. Media Converter Chassis System. User s Manual

4. 4 x Foot Pads 5. Rack-Mount Kit

W INSTRUCTION MANUAL: Q7TEH1026G

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

8-port 10/100Base-TX Switch (INS-806) User s Guide

GSW User Manual. 4-Port TP + 1-Port SFP Gigabit Ethernet Switch. Ver

Modular 8-Port Mid-span Power over Ethernet Injector

100 - SERIES NETWORK SWITCHES Installation Manual

Start Here. Features. Model DS108 Dual Speed Hub Installation Giude

Chapter 1 Product Introduction

LNP-0602 series. 6-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 2*100Fx. User Manual

5/8 Port Gigabit Ethernet Switch

DES-1016R+/DES-1024R+ 10/100 Fast Ethernet Switch

Model : ON-PS3016G. 16 Port 10/100/1000Mbps Gigabit + 2 Gigabit SFP Uplink Unmanaged PoE Switch

LVN5200A-R2, rev. 1, Hardware Installation Guide

Perle MCR200 Installation Guide

Quick Start Guide. Physical Description. The Port Status LEDs

Gigabit Ethernet Switch With 10G Uplinks. Hardware Manual MS400860M

10/100TX to 100FX w/ 1 PoE Injector Industrial Media Converter User Manual

16/24-Port Gigabit Desktop Switch

USER GUIDE. EZ Switch TM 10/100/ /24-Port Gigabit Ethernet Plus Switch SMCGS1610/SMCGS2410

Quick Install Guide AMS-4424P AV Series 26-Port Gigabit Stackable PoE+ L2/L3 Managed Switch

FCC Certifications. CE Mark Warning

8 10/100/1000T Industrial Switch. User Manual MS655208(X)

User Guide. FSW-1641TX/2441TX 16/24 10/100Base-TX Web Smart Switch. FSW-1641TX 16 port 10/100Base-TX Web Smart Switch

Gigabit 1000Base-T to 1000Base- SX/LX Converter

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

LNX-0702G-SFP Series

SOHO Access TM Module. User Guide. SAM-SW5U: 5-port 10/100 Ethernet Switch

Gigabit Metro Ethernet Switches

SW-UNM-24FE2GC-24POE 24 Fast Ethernet Ports PoE + 2 Giga Combo User Manual Ver 1.1

Quick Start Guide. C-100 Series Switches

LNX-1002C-SFP Series

Lantech IPGC-0101DSFP. User Manual. 10/100/1000T (PoE at) to 100/1000M SFP Industrial Switch Converter

Gigabit 1000Base-T to 1000Base- SX/LX Converter. User s Manual NGF-741 Series

Rubber Foot Pads. Rackmount Kit VAC 50/60Hz Power Adapter

Follow the procedure below for unpacking the carton in which the device is shipped. DW-GTW-AC-E1060 Four anti-slide bumpers for desktop installation

16/24 Port Desktop & Rack-mountable Gigabit Ethernet Switch

48-port 10/100TX + 1 SFP Gigabit Port and 1 10/100/1000BASET Port Unmanaged Switch MIL-S4800. User Manual

5 10/100TX w/ 4 PoE Injector Industrial Switch. User Manual

Switch Installation. Preparing for Installation. Safety Warnings

Conventions. Preface. Technical Support & Helpline. Install Guide TNDS-9000P 9-Port Gigabit PoE Switch Series

USER S MANUAL. 5 and 8 Port 10/100/1000Base-T Gigabit Ethernet Switches

Transcription:

Table of Contents About This Guide... 1 Terms/Usage... 1 Copyright and Trademarks... 1 Product Introduction... 2 Package Contents... 2 Product Overview... 2 Front Panel... 2 Rear Panel... 2 Indicator LEDs... 3 Hardware Installation... 4 Installation Precautions... 4 Grounding the Switch... 4 Attaching the Rubber Feet... 5 Mounting the Switch in a Rack... 5 Powering on the Switch... 6 Connecting the Switch... 6 Connect to an End Node... 6 Connect to a Hub or Switch... 7 Connect to a Network Backbone or Server... 7 Understanding the Switch s Features... 8 Power Over Ethernet (PoE)... 8 Power Saving... 8 Appendix A - Technical Specifications... 9 Hardware Specifications... 9 Key Components / Performance... 9 Ports... 9 Port Standards... 9 Physical & Environment... 9 Emission (EMI) Certifications... 9 Safety Certifications... 9 Features... 9 General Features... 9 PoE Features... 9 Appendix B - Regulatory Statements... 10 i

About This Guide This guide provides instructions to install the D-Link DGS-1026MP 26-Port Unmanaged PoE Gigabit Switch. Terms/Usage In this guide, the term Switch (first letter capitalized) refers to the DGS-1026MP, and switch (first letter lower case) refers to other Ethernet switches. Some technologies refer to the terms switch, bridge and switching hubs interchangeably, and all are commonly accepted for Ethernet switches. A NOTE indicates important information to use the device properly. A CAUTION indicates potential property damage or personal injury. Copyright and Trademarks Information in this document is subjected to change without notice. 2016 D-Link Corporation. All rights reserved. Reproduction in any manner whatsoever without the written permission of D-Link Corporation is strictly forbidden. Trademarks used in this text: D-Link and the D-LINK logo are trademarks of D-Link Corporation. Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. D-Link Corporation disclaims any proprietary interest in trademarks and trade names other than its own. 1

Product Introduction The DGS-1026MP is an unmanaged switch with 24 10/100/1000 Mbps ports and 2 Gigabit combo uplink ports. The first 24 10/100/1000 Mbps ports of the DGS-1026MP support IEEE 802.3af/at Power over Ethernet (PoE) and are capable of supplying up to 30 watts of power per port. The DGS-1026MP is easy to install and requires no configuration. With these features combined, the DGS-1026MP provides an ideal solution for Small and Medium Business (SMB) users who have limited budgets but require PoE capability in a switch. Package Contents Open the shipping carton and carefully unpack the contents. Please consult the packing list to make sure all items are present and undamaged. One D-Link DGS-1026MP 26-Port Unmanaged PoE Gigabit Switch One power cord One power cord retainer One rack-mount kit and rubber feet One Quick Installation Guide If any item is found missing or damaged, please contact your local retailer for replacement. Product Overview Front Panel Figure 1 DGS-1026MP Front Panel Item LED MODE Ports 1 to 24 Ports 25 to 26 Description Press to change the port LEDs to display the PoE status or the link status. The color of the LED Mode light will indicate which LED status display is currently active. Green LEDs means the Switch is currently showing the Link/Act/Speed status of the ports, while amber LEDs display the PoE status of the ports. Please refer to the table in the section Indicator LEDs for more detailed information on the LED Mode function. These are 10/100/1000 Mbps PoE-capable ports used for connecting Ethernet devices and PoE-powered devices. These are 10/100/1000 Mbps/SFP combo ports. When using one interface of these combo ports, the other interface in the pair will become unavailable. For example, using the SFP interface on port 25 will render the RJ45 interface on port 25 unavailable. Table 1 Front panel connector description Rear Panel Figure 2 DGS-1026MP Rear Panel 2

Item Kensington Security Lock SWITCH GND Power Cord Retainer Slot DC Power Jack Description The DGS-1026MP adds additional value by providing users with a simple, reliable, builtin security solution to prevent theft in the form of a Kensington Security Slot on the rear panel of the Switch. This is used to connect the switch to ground. This is used for securing the power cord retainer to the switch. This is used to connect the power cable to the switch. Table 2 Rear panel connector description Indicator LEDs LED Status Description PoE Power Budget Figure 3 DGS-1026MP Front panel LEDs Solid red (LED above 300W ): The total PoE power consumption is between 301 and 370 W. Solid amber (LED below 300W ): The total PoE power consumption is between 201 and 300 W. Solid green (LED below 200W ): The total PoE power consumption is between 101 and 200 W. Solid green (LED below 100W ): The total PoE power consumption is between 1 and 100 W. Off There are no PoE-powered devices attached to the Switch. LED Mode Solid amber The port LEDs are currently displaying the PoE status. Please refer to PoE Mode in this table for more information. Solid green Power Solid green The device is powered on. Link/Act/Speed (Ports 1 to 26) PoE Mode (Ports 1 to 24) Solid amber Solid amber Blinking amber Solid green Blinking green Solid amber Solid green The port LEDs are currently displaying the port link status. Please refer to Link/Act/Speed in this table for more information. The device is powered off. There is an active link on the corresponding port at 10/100 Mbps. There is traffic on the corresponding port at 10/100 Mbps. There is an active link on the corresponding port at 1000 Mbps. There is traffic on the corresponding port at 1000 Mbps. The power supply on the corresponding port has failed. The corresponding port is supplying power correctly. 3 Table 3 Front panel LED description

Hardware Installation This chapter provides more detailed instructions for grounding and installing the DGS-1026MP. CAUTION: Ensure the power cable is disconnected before installing the switch. Installation Precautions For safe installation and operation of the Switch, it is recommended to:. Visually inspect the DC power jack and make sure that it is fully secured to the power adapter. Make sure that there is at least 10 cm of space on each side of the Switch to allow for proper heat dissipation and adequate ventilation around the Switch. Install the Switch in a site free from strong electromagnetic sources, vibration, dust, and direct sunlight. Install the Switch in a cool and dry place. Refer to the technical specifications section of this manual for the acceptable operating temperature and humidity ranges. Not place heavy objects on the Switch. Grounding the Switch This section describes how to connect the Switch to ground. It is necessary to complete this procedure before powering on the Switch. Required Tools and Equipment One ground screw (this Switch is shipped with this screw already in place on the rear panel of the device). Ground cable (not included in the accessory kit): The grounding cable should conform to local and national installation requirements. Commercially available 6 AWG wire is recommended. The length of the cable depends on the proximity of the Switch to proper grounding facilities. A screwdriver (not included in the accessory kit). The following steps explain the procedure for connecting the Switch to a protective ground: 1. Verify that the Switch is powered off. 2. Remove the grounding screw marked SWITCH GND from the back of the device and place the #8 terminal lug ring of the grounding cable on top of the ground screw opening, as seen in the figure below. 3. Insert the grounding screw back into the ground screw opening. 4. Using a screwdriver, tighten the ground screw to secure the ground cable to the Switch. 5. Attach the terminal lug ring at the other end of the grounding cable to an appropriate grounding source. 6. Verify that the connection from the ground connector on the Switch to the ground source is secure. Figure 4 Attaching a grounding cable 4

Attaching the Rubber Feet The DGS-1026MP comes with a strip of four adhesive rubber pads that can be placed on the bottom of the device to prevent the Switch from damaging the surface it is placed on. This allows the Switch to be placed virtually anywhere. To attach the rubber pads, simply remove them from the adhesive strip and stick one pad on each corner on the bottom panel of the Switch. Figure 5 - Attaching the rubber feet Mounting the Switch in a Rack The DGS-1026MP can be easily mounted in a rack using the two provided mounting brackets. Make sure that the front panel is exposed in order to view the LEDs. Please refer to the following illustrations: 1. Attach and fasten the rack mounting brackets to each side of the Switch using the included screws. Figure 6 - Attaching the rack brackets 2. Firmly secure the brackets with the Switch to the rack. Please follow the usual safety precautions for rackmountable products. 5 Figure 7 - Securing the Switch to a rack

Powering on the Switch To power on the Switch, connect the provided power cable to the power socket on the back of the Switch, and connect the adapter side of the cord to a suitable power source. After the Switch has been powered on, the LED indicators will blink briefly while the system initializes. As a precaution, in the event of a power failure it is recommended to unplug the Switch. When power has been restored, plug the Switch back in. Connecting the Switch After the DGS-1026MP has been successfully installed, the Switch can be integrated into the network through one of the following three connection methods: NOTE: All Ethernet ports auto-detect MDI/MDIX, port speed (10, 100, or 1000 Mbps), and duplex mode of the device connected to the Switch. Cable Quality For all connections to the Switch, use these rules for cable selection: For connections to 10BASE-T and 100BASE-TX devices, use Category 5 or 5e UTP/STP cable. For connections to 100BASE-TX and 1000BASE-T devices, use Category 5e or better UTP/STP cable. All 1000BASE-T connections will operate in full-duplex mode. NOTE: UTP (Unshielded Twisted Pair) Ethernet cabling is adequate for most small office environments. More expensive STP (Shielded Twisted Pair) can also be used, but is generally only needed when there is risk of strong electromagnetic interference due to radio frequencies. Connect to an End Node Use a standard Ethernet cable to connect the Switch to PCs with a 10/100/1000 Mbps RJ45 interface, or connect and power remote IEEE 802.3af/at-compliant PoE devices, such as IP cameras or IP phones. The Switch ports will automatically adjust to the hardware characteristics (MDI/MDIX, speed, duplex mode) of the connected device. Figure 8 Connecting the Switch to a node 6

Connect to a Hub or Switch Use a straight or crossover cable to connect the Switch to another switch or hub. Figure 9 Connecting the Switch to another switch or hub Connect to a Network Backbone or Server Use any port on the device to connect the Switch to a network backbone or network server. When linking to a 1000BASE-T device, the port operates in full-duplex mode. Figure 10 Connecting the Switch to another switch or hub 7

Understanding the Switch s Features Power Over Ethernet (PoE) The DGS-1026MP supports many PoE features to guarantee the safety and stability of the Switch and the connected powered devices. PoE Power Budget: The total PoE budget of the DGS-1026MP is limited to a maximum of 370 watts to both protect the Switch and to stabilize the power being transmitted to the PoE-powered devices. Guard Band: The DGS-1026MP reserves a 2 watts Guard Band to prevent the PoE power supply from exceeding the maximum PoE power budget of 370 watts. When the Switch detects the current PoE output has reached the maximum of 370 watts, and another device is connected to the Switch, the Switch will check which type of device is being connected. If the device is another PoE-powered device, the Switch will disconnect the power on the port with the higher port number in order to power the new device. PoE Port Priority: The DGS-1026MP is configured to have predefined PoE priorities for all PoE ports to prevent problems such as power budget overloading. Lower number ports have a higher priority for supplying power than higher number ports (i.e. port 1 > port 2 > > port 24). When the Switch detects a PoE budget overload, the power supply from the higher number ports will be cut off first. For example: When ports 2 to 13 are supplying a combined total of 370 watts of power to the attached clients, and a new PoE-powered device is connected to port 1, the power supply from port 13 will be disconnected first. Power Saving The DGS-1026MP supports IEEE 802.3az Energy Efficient Ethernet (EEE), which will constantly monitor all ports for activity and will put inactive ports into a sleep mode to save power. 8

Appendix A - Technical Specifications Hardware Specifications Key Components / Performance Ports Switching Capacity: 52 Gbps Max. Forwarding Rate: 38.69 Mpps Forwarding Mode: Store-and-forward Packet Buffer memory: 512 Kbytes 24 x 10/100/1000BASE-T PoE ports 2 x 10/100/1000BASE-T/SFP combo ports Port Standards IEEE 802.3 IEEE 802.3u IEEE 802.3x (Full-duplex Flow Control) IEEE 802.3z IEEE 802.3az IEEE 802.3af/at (ports 1 to 24) Physical & Environment Dimensions: 440 x 250.4 x 44 mm Weight: 3.1 kg Internal Power Supply AC input: 100~240 VAC, 50/60Hz Acoustic: 41.8 db(a) at low speed, 55.1 db(a) at high speed Operation Temperature: 0 to 50 C Storage Temperature: -40 to 70 C Operation Humidity: 0% to 95% RH Storage Humidity: 0% to 95% RH Emission (EMI) Certifications FCC class A CE Class A VCCI Class A C-Tick CCC BSMI Safety Certifications cul, LVD CB CCC BSMI Features General Features PoE Features Surge protection Supports up to 8k MAC addresses IEEE 802.3af/at compliant Supplies up to 30 watts power per port. Total PoE budget: 370 watts. 9

Appendix B - Regulatory Statements FCC Warning This equipment has been tested and found to comply with the regulations for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with this user s guide, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his/her own expense. CE Mark Warning This is a Class A product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures. VCCI Warning UL Warning a) Elevated Operating Ambient Temperature- If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the manufacturer's maximum rated ambient temperature (Tmra). b) Reduced Air Flow- Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised. c) Mechanical Loading- capitalize of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading. d) Circuit Overloading- Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of circuits might have on over current protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern. e) Reliable Earthing- Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuit (e.g., use of power strips). f) The Installation instructions clearly state that the ITE is to be connected only to POE networks without routing to the outside plant. 10