Configuring a Comm/Terminal Server for Sun Console Access

Similar documents
Configuring a Terminal/Comm Server

Auxiliary Port, Console Port, and Adapter Pinouts for Cisco 1000, 1600, 2500, 2600, and 3600 Series Routers

Appendix A Cable Pinouts

Connector and Cable Specifications

Cable Pinouts. SRP I/O Module

Connector and Cable Specifications

Cabling Guide for Console and AUX

Cable Specifications. Interface Specifications. Fiber-Optic Specifications APPENDIXB

Cisco - Connecting Routers Back-to-Back Through the AUX Ports using a Rollover Cable

Configuring a Modem on the AUX Port for EXEC Dialin Connectivity

How to configure MB5000 Serial Port Bridge mode

Cable and Port Specifications

Quick Start Guide. 8-Port Value-Line Console Server QS Guide LES1508A

Cable and Port Specifications

Lab Establishing a Console Connection to a Router or Switch Instructor Version

CAB 232MT and CAB 232FC EIA/TIA 232 Serial Cable Specifications

DS Series Manual DATA SWITCH. DS62-MD4 Host-Modem Module QUICK START. BayTech Manual Publication

Use NAT to Hide the Real IP Address of CTC to Establish a Session with ONS 15454

RS-232 Connector Pin Assignments

Configuring Basic AAA on an Access Server

Configure a Cisco Router with TACACS+ Authentication

Cable and Port Specifications

SCS1600/3200 Quick Start Guide

E1 and T1 RJ-48 Cable Pinouts on page 208. Fast Ethernet 12-port Cable Pinouts on page 211

Cisco - Ethernet 100BaseTX and 10BaseT Cables: Guidelines and Specifications

Quick Start Guide. Remote Console Manager Quick Start Guide

SCS100/200/400 Quick Start Guide

USB-C to RJ45 FTDI Console Cable USB-A to RJ45 FTDI Console Cable

CTC Fails to Start on Windows XP with Cisco Security Agent

ICP PANEL-TEC PEX3000 II

Using an ADTRAN Terminal Adapter with Cisco Routers

Select a Data Communication Interface

Connector and Cable Specifications

Remote Console Manager with GSM Modem QS Guide

QuVIS CONNECTOR PINOUT GUIDE

Connector and Cable Specifications

Configuring Terminal Settings and Sessions

Miniature Asynchronous 4-Wire High Speed Modems

CAB-X21MT and CAB-X21FC Serial Cable Specifications

Industrial Serial Device Server

Installation and User Guide

Configuring the Switch

Console Management Server VTS. How-To

Configuring Terminal Settings and Sessions

Examples of Cisco APE Scenarios

Connector and Cable Specifications

Implementing Authentication Proxy

NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL

The specifications for the Cisco 7304 router are listed in Table A-1.

Using Cisco IOS XE Software

Configuring the Switch

Telnet, Console and AUX Port Passwords on Cisco Routers Configuration Example

RS-232 SERIAL INTERFACE PHOTOELECTRIC ISOLATOR

Sender Receiver Sender

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)

The information in this document is based on the Cisco VPN 3000 Series Concentrator.

Table 8 shows the pin configuration and function of a standard computer-to-printer parallel cable. Table 8 Parallel Cable Pin Configuration

Enabling the Catalyst Web Interface on Catalyst 4500/4000 Series Switches Running CatOS

Console Port, Telnet, and SSH Handling

NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL

Lantech LSC-1102B SERIAL TO TCPIP CONVERTER. User Manual

Exam E1 Copyright 2010 Thaar AL_Taiey

NAT Support for Multiple Pools Using Route Maps

Lab Command Line Fundamentals Instructor Version 2500

Wrenchman, Inc Old Hwy. # 8 Suite # 122 New Brighton, Minnesota (651)

Cisco DSL Router Configuration and Troubleshooting Guide Step by Step Configuration of RFC1483 Pure Bridging

CRS Historical Reports Schedule and Session Establishment

Tactical Software requires that Cisco IOS Software Release 12.0(9) or later be installed on the NAS to interoperate with DialOut/EZ.

Product Manual. 8-Port RS-232 USB to Serial Adapter Data Control Box. Coolgear, Inc. Version 1.1 September 2017 Model Number: USB-8COM

Configuring a Cisco Secure IDS Sensor in CSPM

WebView and IIS Connection Timeouts

Password Recovery Procedure for the PIX

SPARC Enterprise T5140 Server Getting Started Guide

Configuring Secure Shell on Routers and Switches Running Cisco IOS

SPARC Enterprise T2000 Server Getting Started Guide

First Steps. esom/sk5 esom/3517 Embedded Linux Starter Kit

8 Port USB to RS- 232/422/485 Octal Adapter. Product Manual. Coolgear, Inc. Version 1.1 April 2018 Model Number: USB-8COMi-RM.

USER MANUAL. G.shdsl+ modem with G.703 interface TAHOE 671 FREEDOM OF COMMUNICATION

Module Connectors and Cable Specifications

NTI. KEEMUX Series. KEEMUX-P2 (2-Port PS/2 KVM Switch) INSTALLATION / USER GUIDE R NETWORK TECHNOLOGIES INCORPORATED

Frame Relay Cabling This section describes the cabling and connector pinouts for the Frame Relay cards.

Initial Configuration for the Switch

SPARC Enterprise T5220 Server Getting Started Guide (For Models That Run on DC Input Power)

MODBUS/TCP TO SIEMENS G110/G120/MM440 APPLICATION

How to Configure a Cisco Router Behind a Non-Cisco Cable Modem

GE-DSH-73/82 and 82-POE Managed Switch Installation Sheet

WiFi to RS-232 adapter user manual

Communication adapter RS232 over the Wi-Fi ELO E231. User manual

Hardware Installation Guide Installation (x3350)

Configuring the VPN Client 3.x to Get a Digital Certificate

SitePORTAL Lite TA-SPL32-R48

8-Port RS-232 PCIe Card

Quick Start Guide. 2-Port 10/100 Device Server RS-232/422/485 DB9 M. Access two serial RS-232 or RS-422/485 devices over a 10- or 100-Mbps network.

Logging In to the Sensor

3.1 I-7560 Pin Assignment and Specifications: Introduction

DGH A3000 Configuration Guide For use with DGH Modules

USB to DB25 RS232 Adapter User Manual. Features. Windows 7/ Vista / 2003 / XP / 2000 Driver Installation

NPS Series. Network Power Switch. User's Guide. Models NPS-115 & NPS-230 (Firmware Version 2.04 and Higher)

Product Manual. USB BAY-4 Port Serial DB- 9 RS-232 Adapter with FTDI Chipset. Coolgear, Inc. Version 1.1 September 2017 Model Number: USBG-BAY4

Powered RS Port PCIe Card

Transcription:

Configuring a Comm/Terminal Server for Sun Console Access Document ID: 9588 Contents Introduction Prerequisites Requirements Components Used Conventions Set Up for Console Access to the Sun Server Adapters and Cables Comm Server Configuration Related Information Introduction Cisco Access Servers are often configured as comm servers for console access to a Sun workstation. These configurations refer to the Access Server as a comm server, terminal server or a console server. The configuration for the comm server to connect to the Sun device is similar to the comm server setup for console access to Cisco routers. See Configuring a Terminal/Comm Server for more information on configuring the comm server. Warning: Before you connect the comm server to the Sun workstation, make sure that you read and understand the implications in Terminal Server Break Character on Cisco Access Servers. This field notice warns that Sun workstations can go into maintenance mode or reboot if the console server is reloaded. You must address the issues in this field notice before you proceed. Prerequisites Requirements There are no specific prerequisites for this document. Components Used This document is not restricted to specific software and hardware versions. The information presented in this document was created from devices in a specific lab environment. All of the devices used in this document started with a cleared (default) configuration. If you are working in a live network, ensure that you understand the potential impact of any command before using it. Conventions For more information on document conventions, refer to the Cisco Technical Tips Conventions.

Set Up for Console Access to the Sun Server When you connect to the console port of a Sun server: Enable and correctly configure the serial interface (serial A or B on the Sun) for console access. Use a utility such as Admintool to verify the serial interface status. See Unix System Administrator Resources for more information on how to enable and configure the serial interface Sun workstations. Do not connect a keyboard to the Sun workstation. Sun machines search for the keyboard during power up. If the keyboard is plugged in, the server assumes the console is the locally connected keyboard and monitor. If it does not detect a keyboard, it redirects console input and output to serial port A. Warning: Do not unplug the keyboard once the server is booted up. This causes the console to lock up. If the console locks up, make sure the server can autoboot without intervention and reboot with the keyboard disconnected. Refer to the Sun website for information on autoboot. Set the Sun serial port speed, data bits, parity, and stop bits to 9600 8 N 1 (the default setting) or match the settings configured on the comm server (if different). Make sure you can connect to the console of the Sun using a dumb terminal or PC before you connect the Sun to the Cisco console server. Verify this connection to help isolate and fix Sun related issues before you connect to the console server. See the How To: Serial Console document for more information on using a dumb terminal or PC for console access. Adapters and Cables Obtain or make an RJ 45 to B 25 adapter to attach to the Sun. The adapter allows you to connect the Cisco Access Server to your Sun console. You can obtain an RJ 45 to B 25 male adapter kit at most electronic outlet stores to make the adapter. Use the pinouts table below to you build the adapter. To build the special RJ 45 to DB 25 adapter: 1. Disassemble the adapter. 2. Identify the pins (shown in the diagram below) and compare it to the table below. 3. Connect the wire from each pin on the RJ 45 side to the corresponding pin on the DB 25 side (defined in the table below). For example, connect RJ 45 side pin 1 to pin 4 on the DB 25 side. 4. Use a breakout box or multimeter to make sure the adapter is wired correctly. If using a multimeter, apply a voltage to each pin on the RJ 45 side and make sure the corresponding pin on the DB 25 side receives the voltage. RJ 45 to DB 25 Adapter for the Serial Port of the Sun Signal Pin on RJ 45 side Pin on DB 25 side Signal

CTS DSR RxD GND GND TxD DTR RTS 1 4 RTS 2 20 DTR 3 2 TxD 4 5 7 GND 6 3 RxD 7 6 DSR 8 5 CTS To extend the reach of the CAB OCTAL ASYNC cable (from the comm server), use a straight through cable. If you do not need to extend the reach of the CAB OCTAL ASYNC cable, connect the RJ 45 plug into the RJ 45 to DB 25 adapter as instructed above. Note: The pinout table above is suitable for most Sun servers with DB 25 Serial Ports. Refer to Sun Serial Port and Cable Pinouts to verify the serial port type on your Sun server. If the serial port pinouts for your server do not match the pinouts in the table above, create the adapter by matching the expected signal from the Sun to the appropriate signal provided by the CAB OCTAL ASYNC cable. An alternate method, based on a lab scenario, to connect to the Sun server using a Cisco RJ 45 to DB 25 connector is shown in this table. However, use the procedure previously described to eliminate variables. Cable from Comm Server CAB OCTAL ASYNC (DTE with built in rollover) Extending Cable A 1 RJ 45 satin cable with roll over (CAB 500RJ) is required. Additional cable extensions (if needed) must be straight through. RJ 45 to DB 25 Connector CAB 5MODCM (adapter marked MODEM) This connector must not have been previously modified. The combination above is equivalent to one null modem connection between the two DTEs. If you try the combinations above and cannot establish a connection, verify the connector pinouts or create the RJ 45 to B 25 adapter described previously. Comm Server Configuration

The Cisco comm server configuration excerpt below shows the configuration of the async lines that connect to the console port of the Sun. You must configure the comm server as instructed in Configuring a Terminal/Comm Server. line 1 16 Router 1! Configure the lines that are used for sun console connectivity. session timeout 20! Session times out after 20 minutes of inactivity. no exec! Unwanted signals from the attached device do not launch an EXEC session.! Prevents the line from being unavailable due to a rogue EXEC process. exec timeout 0 0! Disables exec timeout. transport input all! Allows all protocols to use the line. Note: If this configuration does not work, use the flowcontrol hardware in command in configuration mode and reconnect. If you continue to have problems, refer to Configuring a Comm/Terminal Server for Sun Console Access to verify the Sun accepts console connections from a dumb terminal. The output below shows a connection from a comm server (maui oob 01) to a Sun Sparc Ultra 5 server (supersweet), which is connected on line 15 of the comm server, and that is why we use TELNET port 2015 in

the example. The first authentication is performed by the comm server on the outbound connection. The second authentication is performed by the Sun. maui oob 01#telnet 172.22.163.26 2015 Trying 172.22.163.26, 2015... Open User Access Verification Username: Password: supersweet console login: root Password: Last login: Tue Feb 13 08:01:26 on console Feb 13 17:34:54 supersweet login: ROOT LOGIN /dev/console Sun Microsystems Inc. SunOS 5.6 Jumpstart 1.024 August 1997 supersweet:/ > Related Information Configuring a Terminal/Comm Server for Console Access Terminal Server Break Character on Cisco Access Servers How To: Serial Console Sun Serial Port and Cable Pinouts Unix System Administrator Resources Greater Scroll of Console Knowledge Technical Support & Documentation Cisco Systems Contacts & Feedback Help Site Map 2014 2015 Cisco Systems, Inc. All rights reserved. Terms & Conditions Privacy Statement Cookie Policy Trademarks of Cisco Systems, Inc. Updated: Aug 30, 2005 Document ID: 9588