Protection and control. Sepam range Sepam 100 RT. Merlin Gerin Square D Telemecanique

Similar documents
Sensitive Earth-fault Relay SPAJ 111 C. Product Guide

Combined Overcurrent and Earth-fault Relay SPAJ 140 C. Product Guide

Protection and control. Sepam range Sepam 2000 Sepam Sepam 100

Earth-fault Relay SPAJ 110 C. Product Guide

Arc protection relay. Features Three-phase overcurrent function. Application

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006

Feeder protection relay SPAA 121 C. Product Guide

INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1

Residual overvoltage relay

Type MVTT 14 and MVTT 15: Static Digital Time delay relays

Sensitive definite time or inverse time earth-fault stage for back-up residual earthfault

SIPROTEC easy 7SJ45 Numerical Overcurrent Protection Relay Powered by CTs

Combined Overcurrent and Earth-fault Relay SPAJ 141 C. Product Guide

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O

Arc protection relay. Features Three-phase overcurrent function. Application

Technical specifications

CompactBlock Guard I/O EtherNet/IP Safety Modules

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

Voltage regulator. SPAU 341 C 1MRS MBG Issued: July 1998 Status: Revised Version: C/ Data subject to change without notice

ABS2EC01EB input interface module mm - solid state - 24 V DC

RE Product data sheet Characteristics. universal plug-in timing relay - flashing s..60 mn V AC - 2 OC. Main.

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

Synchro-check relay. Application

RE22R2KMR Off-delay Timing Relay s 10min V AC/DC - 2C/O

High impedance protection relay

High Impedance Protection Relay SPAE010, SPAE011. Product Guide

RE11RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

Model Number Structure

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

Communication Gateway COM 610. Product Guide

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

02/11/2015

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

ICS Regent. Monitored Digital Input Modules 24 VDC (T3411) PD-6031

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

ekorrps MULTIFUNCTIONAL PROTECTION UNIT CONFIGURATION AND GENERAL CHARACTERISTICS LIB

02/11/2015

RE Product data sheet Characteristics. time delay relay for star-delta starter ms - 230/380 V AC - 1 contact. Main.

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

Feeder protection relay

TM3DI16 module TM3-16 inputs

Syr-line TMR48D Digital Timer

Feeder protection relay SPAA 341 C. Product Guide

RE22R2CMR Off-delay Timing Relay s 300h V AC/DC - 2C/O

Zelio Count - Counters RC87610

Messaging module CP-C MM

XU1-E Earth fault voltage relay. (August 1996) Manual XU1-E (Revision New)

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

RM35JA32MR Current control relay 0.15A 15A, 2 C/O

Flair 21D - 22D - 23D - 23DM Self-powered, adjustment-free fault passage indicators

08/07/2015

ICS Regent. Relay Output Modules. Low Power and High Power (T3446L and T3446H) PD-6017

ABL8BBU24200 battery control module V DC - 24 V - 20 A - for regulated SMPS

Electronic timer CT-ERS.21

Relion 611 series. 611 series Type Test Certificate

Syr-line TMR48D Digital Timer

RE22R2QTMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

RM4JA01F current measurement relay RM4-J - range ma V AC

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

Type VRLTC tap changer

MSR 2400R. Rugged Power System for Military and Heavy Duty Applications

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

XMLK006B2C21 pressure sensor XMLK bar - G 1/4A mA - DIN - set of 1

GRD130 - FEATURES APPLICATION

TM200CE24T controller M IO transistor Source+ Ethernet

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

Electronic timer CT-ARS.11

RM4JA32MW current measurement relay RM4-J - range A V AC DC

For Transmission, Distribution and Machinery protection.

TM221M16R controller M IO relay

Electronic timer CT-ERD.12

TM221M16TG controller M IO transistor PNP spring

TM7BDM8B. Main. Enclosure material. Input/output number 8 Input/output number of splitter box

FL MC 2000E (SM40) LC

RTU511. Binary Output 23BO62. Characteristics. Application. Data Sheet Binary Output 23BO62. The binary output is made via relay contacts.

XPSMCMDI Input expansion module with screw term

TM241C40U controller M IO transistor NPN

TeSys protection components

TM241C24T controller M IO transistor PNP

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

Electronic timer CT-AHD.22

02/11/2015

TM3SAC5RG SAFETY MODULE FOR PLC TM2xx, 1 FUNCTION, CAT3, SPRING TERMINALS

TM221ME16T controller M IO transistor PNP Ethernet

TM3AI4 module TM3-4 analog inputs

TM3SAF. Main. Device short name

XGCS491B201 Standalone panel smart antenna

DC562, digital input/output module,

TM7BDI16B. Main. Enclosure material. Input/output number 16 Input/output number of splitter box

ABL8BBU24400 battery control module V DC - 24 V - 40 A - for regulated SMPS

Directional or Non-Directional Earth-Fault Relay REJ 527. Product Guide

Table 1 Relay Model and Function

Control Panel CP600 CP651, CP651-WEB

XB4BK123B5. Product data sheet Characteristics. Complete illuminated selector switch. position stay put 1NO+1NC 24V. Main.

Relays for Various Protection Applications / 7SV600

Transcription:

Protection and control epam range epam T Merlin Gerin quare D Telemecanique

presentation contents page presentation connection characteristics installation ordering information epam T. on in in in in in out epam is a group of modules that may be used: individually to perform a function, in combination with epam or. Each module has been designed to perform a complete function. It includes all the elements required, such as: tripping relays, annunciation, connections. applications epam T pecially designed for transformer protection applications, offering a combination of DGPT or Buchholz plus thermostat information. advantages imple to use: three "tripping" inputs, two "alarm" inputs with the possibility of individual "tripping" input parameter setting, electrically latched inputs, a "tripping" with high breaking capacity linked with two other s: "inhibit closing" and "annunciation", two "alarm signal" s linked with the two "alarm" inputs, local or remote acknowledgment, integrated "lamp test". Clear information display of "tripping" input and status on the front of the device. Dependable operation high level of immunity to electromagnetic disturbances: epam T is designed to operate safely in the highly disturbed electromagnetic environments of HT substations. description The front of epam T includes: indicator lamps: device "on" indicator, "In" to "In" indicators: electrically latched indicators which store the activated status of each of the 'tripping" inputs, "In" and "In" indicators: electrically latched indicators which store the activated status of the "alarm" inputs and indicate the status of the "alarm " and "alarm " relays, "out" indicators: latching indicator which shows switching of the "tripping" relay. a "reset" pushbutton: for acknowledgment of the relay s and associated display when the inputs return to their normal position. While activated, this pushbutton may be used for a lamp test of the indicators on the front of the device. The back of epam T includes: input/ connectors: a -pin connector for the "alarm" inputs and s, an -pin connector for the "tripping" and for the power supply, a -pin connector for the "power ON". epam T has: common-point logic inputs, named "In" to "In", an isolated remote "reset" input, a -contact "tripping" relay ( normally open contacts and normally closed contact), "alarm" relays (changeover contacts), a "power ON" relay ( normally open contact and normally closed contact). epam T operates in ranges of supply voltage (please specify when ordering): - V DC ±%, - V DC ±%, - V DC -% +%. reset sepam T Front of device with display and control of acknowledgement/lamp test..

parameter setting The parameters of the "alarm" inputs made be set so as to make them "tripping" inputs. "larm" inputs In and In may be set individually as "tripping" inputs. The choice is made via two microswitches that are accessible on the left-hand side of epam T. ccess to the microswitches is closed off by a removable plastic cover. The plastic cover should be replaced after the setting has been made. ccess to and identification of microswitches - and -. - - Parameter setting "larm" position. Move the microswitch tab to the left. "Tripping" position Move the microswitch tab to the right. functional and connection diagram com In In - In O O alarm alarm "alarm" inputs In - In In In In In "tripping" inputs reset reset PB + aux. sup. - on In out O O O O B tripping s power on

connection epam T -pin CC connector (power supply and "tripping" s), screw terminal wiring with wires. to. mm max. Each terminal capable of receiving two. mm wires. -pin CC connector ("alarm" inputs and s), screw terminal wiring with wires. to. mm max., each terminal capable of receiving two. mm wires. T B CC connector (power ON), screw terminal wiring for wires. to. mm max. Each terminal capable of receiving two. mm wires. 9 O O O O B tripping annunciation inhibit closing + aux supply power on 9 9 reset inputs In In In In In common alarm alarm B B P + B -VDC -VDC -VDC -VC -VC 9 -VC -VDC -VDC -VDC -VC earthing terminal Terminal identification Each terminal is identified by characters. board slot number ( to ) connector identification letter ( or B) connector terminal number

Example of input wiring (transformer protection) -C +C remote reset EPM T reset thermostat (tripping) buchholz (tripping) thermostat (alarm) buchholz (alarm) In In In In In Com + - power Example of circuit breaker control contact wiring +C on off epam T M CLOE TIP C

characteristics electrical characteristics logic inputs / Vdc / Vdc / Vdc power consumption m m m typical filtering time logic s (relays) ms breaking capacity () / Vdc Vdc Vdc / Vdc contact O.. contacts O to O... making capacity permissible steady state current number of operations under full load response time typical ms (inputs to s) max. ms power supply range typical maxi inrush current consumption consumption / Vdc ± %. W, W < during ms / Vdc ± %. W. W < during ms / Vdc - %, + % W 9 W < during ms environmental characteristics climatic operation IEC - - C to + C storage IEC - - C to + C damp heat IEC - 9% to C mechanical degree of protection IEC 9 IP on front vibrations IEC --- class I shocks IEC -- class I seismic tests IEC -- class I fire NFC glow wire dielectric power frequency IEC - () kv - min../ µs impulse wave resistance IEC - kv electromagnetic radiation IEC -- class x V/m electrostatic discharge IEC -- class III damped MHz wave IEC -- class III ns fast transients IEC -- class IV () published in 9 and amended in 99. marking on our product guarantees their conformity to European directives.

installation dimensions and weight epam mounting latch cut-out max max e = mm max weight: kg. mounting details

Ordering information epam T quantity:... auxiliary power supply: to Vdc... to Vdc... to Vdc... chneider Electric postale address F- Grenoble cedex 9 tel: () telex: merge F s standards, specifications and designs change from time to time, please ask for confirmation of the information given in this publication. This document has been printed on ecological paper. C/EN T. Publishing: chneider Electric Design, production: Idra Printing: / 99