FICHA TÉCNICA DE PRODUTO

Similar documents
Inform IT Single Pen Circular Chart Recorder

FICHA TÉCNICA DE PRODUTO

C1900 Series Circular Chart Recorder. C1900 a rugged, reliable recorder with the full capability to meet your needs

ABB MEASUREMENT & ANALYTICS DATA SHEET. C1300 Advanced circular chart recorder

C1300 Advanced Circular Chart Recorder. C1300 dependable recording in a rugged, functional instrument

C1300 Advanced Circular Chart Recorder. C1300 dependable recording in a rugged, functional instrument

ABB Instrumentation. Specification DataFile. COMMANDER 1900 a rugged, reliable recorder with the full capability to meet your application needs

C160 Wall-/Pipe Mounted Universal Process Indicator

Inform IT Circular Chart Recorder/ Controller

100mm Process Indicator Recorder

/8 DIN Universal Process Indicator

ABB Instrumentation. Specification DataFile COMMANDER 100. the-easy-to use 1. /8 DIN controller with extensive application capabilities

Wall-/Pipe Mounted Universal Process Indicator

/8 DIN Motorized Valve Controller

ABB MEASUREMENT & ANALYTICS DATA SHEET. C1950 (STLR & HTST) Pasteurizer recorder and recorder / controller

FICHA TÉCNICA DE PRODUTO

FICHA TÉCNICA DE PRODUTO

C1950 (STLR & HTST) Pasteurizer Recorder and Recorder Controller

Control IT. /16 DIN Controller/Alarm Unit. Data Sheet SS/C50_7 C50. C50 the 1 /16 DIN controller to suit your simplest applications

FICHA TÉCNICA DE PRODUTO

Universal Process Controller

FICHA TÉCNICA DE PRODUTO

ControlMaster CM10 Universal process controller, 1 /8 DIN. Making process control easy

Digital Indicator DS 48/24 E

FICHA TÉCNICA DE PRODUTO

C /4 DIN Multi-Recipe Profile Controller. C360 a comprehensive profile controller for all ramp/ soak applications

ControlMaster CM15 Universal process indicator, 1 /8 DIN. Making process control easy

Pasteurizer Recorder and Recorder Controller

ControlMaster CMF160 Universal process indicator, fieldmount

Indicomp 4 Bargraph Indicator

SM2000 Videographic recorder Spare parts and upgrade kits

TEPI11 P/I signal converter

Replacement Parts and Upgrade Kits for C1900 and C1300 Circular Chart

FICHA TÉCNICA DE PRODUTO

RTU500 series Data Sheet Power Supply CP-E 24/2.5

SM1000 Videographic recorder Spare parts and upgrade kits

TRACKER 220 SERIES. Digital Panel Indicators. A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

Replacement Parts and Upgrade Kits for C1900 and C1300 Circular Chart

Adapter Plates for continuous Part-Turn Actuators (Contrac)

Introduction. For more information. HART Protocol 7.0 Valid for software levels from 05.00

Electronic timer CT-ARE OFF-delayed without auxiliary voltage, 1 c/o (SPDT) contact

LineMaster 100 Continuous-line Recorder

Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact

Switching relay CT-IRE with 1 c/o (SPDT) contact

Using the WirelessHART transmitter TTF300-W as repeater to extend the availability of a WirelessHART network

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

ControlMaster CM10, CM30, CM50 and CM15 Universal process controllers and indicator Spare parts

ABB i-bus KNX HCC/S Heating/cooling circuit controller

ScreenMaster series Paperless recorders

ABB MEASUREMENT & ANALYTICS DATA SHEET. DataManager Pro RDM500 Advanced data review software

ABB MEASUREMENT & ANALYTICS DATA SHEET. TB84PH ph /ORP / pion transmitter

ABB Instrumentation. Specifications. COMMANDER 505 Advanced Process Controller

Electronic timer CT-ERS.12 ON-delayed with 1 c/o (SPDT) contact

FICHA TÉCNICA DE PRODUTO

Control IT Booster Pump Controller

ABB Instrumentation. Multipoint Chart Recorder COMMANDER SR250B. Specification DataFile

Inform IT 250mm Multipoint Strip Chart Recorder

Redundancy unit CP-D RU Accessory for CP range power supplies (e.g. switch mode power supplies CP-D range)

Electronic timer CT-SDS.23 Star-delta change-over with 2 n/o contacts

MRC 7000 Proven Recording Reliability that Became the Industry Standard!

Strip Chart Recorders Specification Sheet

Messaging module CP-C MM

ABB MEASUREMENT & ANALYTICS DATA SHEET. ControlMaster CM10 Universal process controller, 1/8 DIN

Redundancy unit CP-A RU

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

RTU511. Binary Output 23BO62. Characteristics. Application. Data Sheet Binary Output 23BO62. The binary output is made via relay contacts.

FICHA TÉCNICA DE PRODUTO

FICHA TÉCNICA DE PRODUTO

ABB MEASUREMENT & ANALYTICS DATA SHEET. DataManager Pro RDM500 Advanced data review software

MODCELL 2050R Single Loop Controllers

Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact

Crane-Boy / Crane-BoyP Load limitation electronics

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages

ControlMaster CMF160 Universal process indicator, fieldmount

ABB i-bus KNX BCI/S Boiler/Chiller Interface

Controller module. Brief description. Features. Block structure. Page 1/7. Data Sheet

INDI BOY DSP Load limitation electronics

Basic Temperature and Limit Controllers. Provide Economical Solution for a Wide Range of Applications SPECIFICATION SHEET

The CAL range of temperature controllers

ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077

Installation Guide. COMMANDER 1900 Series Circular Chart Recorders. All Versions !50.8 degf OP

VER05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input. Output

ControlMaster CMF160 Universal process indicator, fieldmount

ControlMaster CM15, CM30 and CM50 Universal process indicator and controllers Customizing the operator page displays

UNIVERSAL TEMPERATURE TRANSMITTER

LME620-AI/-AN (Contrac) Electrical Linear Actuator

RTU560. CT/VT Interface 560CVT10. Meter Operation. Application. Characteristics. Data Sheet CT/VT Interface 560CVT10. Instantaneous Meter Values

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

ABB MEASUREMENT & ANALYTICS DATA SHEET. IT1 Universal weighing terminal

Electronic timer CT-APS.21 OFF-delayed with 2 c/o (SPDT) contacts

Power supply CP-E 48/1.25 Primary switch mode power supply

Isolated Linearized RTD Input 5B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

OBSOLETE. Isolated, Linearized, Thermocouple Input 3B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Controller module. Brief description. Features. Block structure. Data Sheet Page 1/7

Power supply CP-E 24/0.75 Primary switch mode power supply

DIGITAL INDICATING CONTROLLER

ABB Instrumentation. Installation Guide. COMMANDER 1900 Series Circular Chart Recorders. All Versions !50.8 degf OP

AMC 8 & IOC 8T. Analog Monitoring Card Type AMC 8 and Input / Output Card Type IOC 8T FEATURES

Transcription:

FICHA TÉCNICA DE PRODUTO PRODUCT DATASHEET HMI Automação e Instrumentação, Lda. Rua dos 5 Caminhos, nº 570 4780-382 Santo Tirso PORTUGAL Web: www.hmi.pt Tel. +351 252 850 501 Fax. +351 300 013 487 Email: hmi@hmi.pt

Data sheet DS/ EN Rev. H a rugged, reliable recorder for all single channel recording applications Universal process input ma, mv, V, thermocouples and resistance Signal linearization full range of linearizers included as standard NEMA 4X/IP66 construction hosedown protection Optional Totalizer function 8-digit flow totalizer 6-digit indicator panel continuous display of process value

The is a single pen, fully programmable circular chart recorder. The instruments straightforward operator controls and robust construction make it suitable for a variety of industrial environments. Designed to survive NEMA 4X protection ensures the can survive in the harshest environments and makes the recorder ideal for use in panels which are regularly hosed down. The tough, acid-resistant case and secure cable-entry glands maintain the NEMA 4X rating for wall-mount or pipe-mount instruments. Easy to install A choice of mounting options enables simple installation of the recorder in a panel, on a wall or on a pipe. Mains isolation can be provided by an optional power switch within the instrument. Wall-mounting Pipe-mounting Panel-mounting 2 DS/ EN Rev. H

Specification General Construction Size Weight Case material Window material Door latch Environmental Installation Operation and configuration Safety Approvals Power supply Totalizer 15.23 in. (h) x 15.04 in. (w) x 5.57 in. (d) (386.8 x 128.0 x 141.5 mm) 18 lb (8.2 kg) Glassfiber-filled reinforced polyester Polycarbonate High-compression with optional lock Operational temperature range 32 to 130 F (0 to 55 C) Operational humidity range 5 to 95 % RH (non-condensing) 5 to 80 % RH (chart only) Case sealing NEMA 4X (IP66) Fast transients IEC 801-4 Level 3 Mounting options Panel, wall or pipe Terminal type Screw Wire size (max) 14 AWG (I/O), 12 AWG (power) Fast transients IEC 801-4 Level 3 Programming method Security General safety Isolation Memory protection CE CSA CSA/FM Class 1 Div. 2 UL Via front panel keys Password protected menus IEC348 2kV DC (channel/ground) Nonvolatile FRAM Panel, wall or pipe (option) (option) (option) Voltage 100 to 240V AC ±10 % (90V min. to 264V AC max.) 50 / 60Hz Consumption <30 VA Line interruption Up to 60 ms Size Count direction Preset 99,999,999 max. Up or down User-programmable Process input General Noise Rejection Common mode >120dB at 50 / 60Hz Normal (series) mode >60dB at 50 / 60Hz CJC rejection ratio <0.05 C / C Sensor break protection Upscale or downscale drive Out of range detection 0 to 100 % of engineering span Temperature stability <0.02 % of reading / C or 1 µv / C Long-term drift <0.01 % of reading 10 µv annually Input impedance >10 M (mv and V inputs) 100 (ma input) Analog input Signal types mv, V, ma, Thermocouple types B, E, J, K, N, R, S, T Resistance thermometer Pt 100 Other linearizations x 3/2, x 5/2, square root Sample interval 250 ms Digital filter 0 to 60s programmable Recording system Pen Color Response Resolution Pen lift Chart Chart size Chart speed Rotation accuracy Display and operator panels Displays Type Panel keys Function EMC Emissions and immunity Meets requirements of: EN50081-2 EN50082-2 EN61326 for an industrial environment CE mark Red 7 seconds (full scale) 0.1 % steps Motor-driven, with optional auto-drop 10 in. or 105 mm 7 seconds (full scale)1 to 167 hours or 7 to 32 days per revolution <0.5 % of rotation time 6-digit red LED, 0.56 in. (14 mm) high Programming access, increment / decrement, pen lift and user-defined function key DS/ EN Rev. H 3

Analog input performance Type Range Lo Range Hi Min. Span Accuracy mv 0 150 5 ± 0.1 % reading or 10 µv V 0 5 0.1 ± 0.1 % reading or 20 mv ma 0 50 1 ± 0.2 % reading or 0.2 µa (low) 0 750 20 ± 0.5 % reading or 10 (high) 0 10 k 400 ± 0.5 % reading or 0.1 C F Type Range Lo Range Hi Range Lo Range Hi Accuracy (excl. CJC) B 18 1800 0 3270 ± 2 C (above 200 C) (3.6 F above 434 F) E 100 900 140 1650 ± 0.5 C (± 0.9 F) J 100 900 140 1650 ± 0.5 C (± 0.9 F) K 100 1300 140 2350 ± 0.5 C (± 0.9 F) N 200 1300 325 2350 ± 0.5 C (± 0.9 F) R 18 1700 0 3000 ± 1 C (above 300 C) (1.8 F above 572 F) S 18 1700 0 3000 ± 1 C (above 200 C) 1.8 F above 572 F) T 250 300 400 550 ± 0.5 C (± 0.9 F) PT100 200 600 325 1100 ± 0.5 C (± 0.9 F) 4 DS/ EN Rev. H

X Wiring connections 3 3 3 6 + 6 + 6 + Voltage Thermocouple Low Voltage (mv) 3 4 + 4 5 6 Red White Red 4 5 6 Link White Red Current 3-wire RTD 2-wire RTD and Resistance Standard input connections Earth (Ground) Stud 2 3 4 5 6 Line Neutral Power Switch (Optional) Fuse (Optional) Power supply connections DS/ EN Rev. H 5

Overall dimensions Dimensions in mm (in.) 15.04 (382) 15.23 (386) 1.30 (33) 2.60 (66) 1.38 (35) Typical Space Between Adjacent Knockout Centers 7.22 (183.4) 12.63 (320.8) 1.44 (36.6) 0.88 (22.35) 12.63 (320.8) 6 DS/ EN Rev. H

Ordering information single pen circular chart recorder 1901 X X 0 X X X 0 0 0 0 0 XXXX Chart type Build Taylor (ER/C) charts KPC 105, Kent PX and Kent PXR type charts Chessell brand charts ABB standard CSA approved CSA/FM Class 1 Division 2 approved UL approved Options None Totalizer Door lock Not fitted Fitted Power supply 115V AC 230V AC 115V AC with on/off switch 230V AC with on/off switch Programming / Special features Configured to factory standard Configured to customer requirements (customer to complete and supply custom configuration sheet INF08/031) Special features Engineered configuration (customer to supply configuration details required) J K C A B F U 0 3 1 2 1 2 4 5 STD CUS SXX ENG Accessories ENG/REC After-sales engineered configuration service DS/ EN Rev. H 7

Our offering: Actuators and Positioners Analytical Instruments Device Management, Fieldbus and Wireless Flow Measurement Force Measurement Level Measurement Natural Gas Measurement Pressure Measurement Recorders and Controllers Temperature Measurement HMI Automação e Instrumentação, Lda. Rua dos 5 Caminhos, nº 570 4780-382 Santo Tirso PORTUGAL Web: www.hmi.pt Tel. +351 252 850 501 Fax. +351 300 013 487 Email: hmi@hmi.pt

Contact us ABB Limited Process Automation Howard Road St. Neots Cambridgeshire PE19 8EU UK Tel: +44 (0)1480 475321 Fax: +44 (0)1480 217948 ABB Inc. Process Automation 125 E. County Line Road Warminster PA 18974 USA Tel: +1 215 674 6000 Fax: +1 215 674 7183 Note We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB. Copyright 2014 ABB All rights reserved 3KXR200105R1001 DS/ EN Rev. H 02.2014 www.abb.com/recorders Sales Service Software