SOHORAID Series. SR2611 Series. Manual. Two Bays RAID 1 Internal Module

Similar documents
InTANK Series ir2620-2s-s2 / SR2611-2S-S2R User Manual

XL-RAID-213SA User Manual

RAIDTech USER S MANUAL. Revised October 3, Features

XL-RAID-SATA-USB Data Backup System. User s Guide

SOHOTANK Series. Quick Installation Guide WCMRP4BESATA. Version:1.0

Taurus Super-S LCM. Dual-Bay RAID Storage Enclosure for two 3.5 Serial ATA Hard Drives. User Manual July 27, v1.2

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1

SR2611-2S-S2R+ (6G) (2 CD-ROM Bays for Two 2.5"-3.5 HDD/SSD Internal RAID Module)

Your Data Security Guardian. SafeTANK GR5630-WSB3+ User Manual. v.1.0 (Oct, 2012)

ACARD ATA-133 RAID AEC-6880M

SafeTANK GR5630-SB3. User Manual. v.1.0 (April, 2011)

Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2

1. Introduction 1.1.Product Overview

RACK-220 CHASSIS USER S MANUAL

Hydra Super-S LCM. 4-Bay RAID Storage Enclosure (3.5 SATA HDD) User Manual July 30, v1.2

Goblin. HDD Image Maker. User Guide V 1.0

NT2 U3. 2-Bay RAID Storage Enclosure. User Manual May 18, 2010 v1.1

MD4 esata. 4-Bay Rack Mount Chassis. User Manual February 6, v1.0

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.0

Taurus Mini Super-S LCM

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.2

RM12_1394B. User Manual. Ver Date: 02/2006.

XL-NAS-400SA. User s Guide

Taurus Mini Super-S3. Dual-Bay RAID Storage Enclosure for two 2.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.1

SilverSATA II SJ USER S MANUAL. Features. Table of Contents

RAID Rack (RR2035RPHMS)

T E C H N O L O G I E S. User Guide. 1:1 Duplicator (HDUSAS)

Technical Reference - Q&A TSD-QA-14 ( Dec. 12th, 2003)

HD MAX Hard Disk Drive Duplicator. User s Manual

apple Service Source Xserve RAID Xserve RAID and Xserve RAID (SFP) Updated: 25 May Apple Computer, Inc. All rights reserved.

HDDkey The KEY for your undisturbed sleep...

apple Service Source Xserve RAID 17 March Apple Computer, Inc. All rights reserved.

A12S2-PS. Quick Start Guide. August, 2012 V.1.4

CHASSIS INSTALLATION GUIDE

SOHOTANK ST4-TB User Manual

AND ULTRATRAK100 TX8 USER MANUAL

InTANK Series-iR2770. Internal RAID Module. The connector location is the same with 3.5 HDD

Home Theater PC Chassis

CONTENTS. Thank you for purchasing a High-Quality Rosewill Product.

DNS-2608 Enterprise JBOD Enclosure User Manual

Chenbro. ES34169 Chassis User s Manual. April / 2 /

CarryMiniFlashDuplicator V 1.0. Flash Copy Tester SD 300+ Fast Copy and Problem Diagnosis! EN User Guide

SAS JBOD Installation Reference Guide Revision 1.0

A+ Guide to Hardware: Managing, Maintaining, and Troubleshooting, 5e. Chapter 6 Supporting Hard Drives

PRO218(1-2) HDD Duplicator

Addonics T E C H N O L O G I E S

8/16/32-Ch Network Video Recorder NVR Series

T E C H N O L O G I E S. User Guide. 1:5 Duplicator (HDU5SAS)

Taurus S2. User Manual. Dual-Bay Storage Enclosure for 3.5 Serial ATA Hard Drives. (English )

SOLO NETWORK (11) (21) (31) (41) (48) (51) (61)

WD Red Drives in a third party enclosure User Interface may display a failed message

Taurus Super-S Combo

PRO118(1-1) HDD Duplicator

FWA-6280A User Manual 1. FWA-6280A User Manual

User Guide RAID Rack (RR2035ASDML)

ACT-ARS3020/22 Disk Array Series products

RocketRAID 3600 Series

Owner s s Manual. SATA A II LCD Hot-Swap Systems. Macintosh, Windows, Linux EXTERNAL SYSTEM INTERNAL 5.25 SYSTEM DUAL EXTERNAL SYSTEM

RocketRAID 464. User, s Manual. Revision: 1.0 Date: Jun HighPoint Technologies, Inc.

T E C H N O L O G I E S. User Guide. 1:1 HDD Duplicator PRO (HDUSI325)

DVD Duplication Towers

USER S MANUAL. CD/DVD Duplication System. Automated Optical Disc Duplication & Printing System (01) 2005 All rights reserved AUTOPRINTER

19 Rackmount Cases A3211. Enrich Your Product Line and Build Your Brand Awareness

Digital Video Surveillance System Engineering Service Manual

PAC-125 CHASSIS USER S MANUAL

PRO118 (1-1) HDD Duplicator

Data rate - The data rate is the number of bytes per second that the drive can deliver to the CPU.

CHENBRO. 4-Port SAS / SATA-II Backplane 80H User s Manual. Version 1.1~1.3. July / 18 / 2008

RAIDGuide RAID Manager

3. Specifications I Features System Requirements Creating A New Partition / Formatting The Hard Drive RAID Mode Selection...

User Guide Automatic Transfer Switch (ATS)

Atlas S8+ Product Manual. Version Promise Technology, Inc. All Rights Reserved.

T E C H N O L O G I E S. User Guide (HDUS4SNDXHS-A)

User manual. Gaming 978BG - Tank-Buster

T E C H N O L O G I E S ENT ESC. User Guide. 1:5 HDD Duplicator Deluxe (HDUS5325DX)

HOME THEATER PC CHASSIS

3U 16-bay PCI-Express Rackmount JBOD Chassis. Installation Guide

RAID User Guide. Edition. Trademarks V1.0 P/N: U25-A2-0E

RocketRAID 600L. User s Guide. SATA 6Gb/s PCI-Express 2.0 RAID Host Adapters. Revision: 1.0 Nov. 19, 2012 HighPoint Technologies, Inc.

ReadyNAS OS 6 Desktop Storage Systems

Guardian MAXimus ASSEMBLY MANUAL & USER GUIDE

Chapter 3: Computer Assembly

Igloo 800. External Enclosure for two (2pcs) 3.5 Hard Drives

Quick Installation Guide

NAS System. User s Manual. Revision 1.0

ACT-ARS5013/23 Disk Array Series products

Offline Array Recovery Procedures SuperTrak SX6000 and UltraTrak

Dolphin 5900 CD/DVD Tower User Manual

Travel Lite ( 旅 ) USER MANUAL. 2.5 SATA to USB EXTERNAL ENCLOSURE

Contents. P.3 Accessory Box. P.8 P.9 Fan Installation System Ready Optional: Additional Fan & Liquid Cooling Radiator

T E C H N O L O G I E S ENT ESC. User Guide. 1:4 CF or CFAST Duplicator PRO (CFASTD4-2S / CFD4-2S)

Introduction.. 2. Chapter 1: Assembling External Storage Device. 3. Chapter 2: Connecting External Storage Device... 4

User s Manual. DataTale TM PAIR 2-HDD RAID System. for 2.5 SATA HDD. Air light enough and connectable anywhere! USB 2.0 esata FireWire 800

User Guide 1U RAID Rack with esata /U3 /FW800 (R1ESU3F)

Contents. Getting Started...1. Managing Your Drives...9. Backing Up & Restoring Folders Synchronizing Folders...52

Dual/Quad 3.5 SATA to USB 3.0 & esata External Hard Drive RAID/Non-RAID Enclosure w/fan. User s Manual

Taurus - USB. User Manual. Dual-Bay Storage Enclosure for 3.5 Serial ATA Hard Drives. (English)

Rocsecure NE52 NAS System

User Guide 1:11 HDD Duplicator NB (HDUS11NB)

Transcription:

SOHORAID Series SR611 Series Manual Two Bays RAID 1 Internal Module

Your Data Security Guardian SOHORAID Series w w w. s t a r d o m. c o m. t w

SR611-S-S1 Quick Installation Guide SOHORAID Series Version:1.0

Index Check Package Contents and Accessories... System Requirement & Environment requirement and notices... 3 Hardware Installation Procedure... 4 Connecting SR611 to your computer... 5 Setting the Hard Drive Array Mode... 6 Computer Set Up... 7 Hard Disk status on LCD screen... 8 Appendix:Trouble Shooting/Q&A... 10 1 Index

User s Guide Check Package Contents and Accessories SR611 system includes the following: Item Quantity SR611 1 Removable Carrier Internal RS3 cable 1 External RS3 cable 1 45cm Cable 1 User s Guide 1 RAIDGuide CD 1 Accessories bag 1 (includes 6#-3 screws x 8 pcs, Key for keylock x ) SR611 Internal RS3 cable Removable Carrier External RS3 cable 45cm cable User s Guide RAIDGuide CD Accessories bag Please check above parts are included prior to installation. The accessories bag contains screws and a plastic key. Hardware Introduction Front Panel 6 Real Panel 1 5 3 +5V GND +1V FAN RS3 3 4 1 4 1 LCD Panel HDD Tray 1 e Port Power Socket 3 Mute Buttom 4 Key Lock 3 RS3 Port 4 5cm Fan 5 HDD Access LED 6 Fail LED Status Indications of LEDs: HDD Access LED will flash yellow when the data is accessed from the hard drive. Fail LED will light red when HD failed, temperature is higher than 60 C or fan fails. Check Package Contents and Accessories

System Requirement Hardware Requirement 1. Computers or servers with Type 1.. Hard drive with Type 1/ interface. 3. The computer or server must run on the Windows system and has RS3 port to install the RAIDGuide GUI software. Environment requirement and notices 1. SR611 s brilliant design allows the user to simultaneously utilize two hard drives manufactured by different companies. However, if the user expects better efficiency, we strongly recommend the users to use hard drives manufactured by the same manufacturers.. Since the system uses more stringent factors to determine the disk corruption in the hard drive, please use noncorrupted hard drive with minimum storage capacity of 0 GB. 3. Please don t set any MASTER or Single Drive mode for first and second hard drive in SR611, the system will detect the hard drives automatically. 4. The SR611 had undergone strict hard drive compatibility test. The result shows that it is compatible with most hard drives on the market such as Maxtor, Western Digital, Seagate, Fujitsu, Hitachi, and etc. However, due to the new types of hard drives appearing on the market, if your hard drive is not compatible with the system, please contact us at www.stardom.com.tw or download the latest firmware updates. 5. The SR611 is equipped with a 5. cm ball bearing cooling fan that will provide effective cooling for the 700 rpm hard drive. We highly recommend using computer chassis with effective cooling design to avoid disk array crashing due to ineffective cooling. 6. SR611 supports RAID 1 only. 3 System Requirement & Environment requirement and notices

Hardware Installation Procedure 1.Connect the cables on the removable hard drive carrier to the pins of hard drive.. Secure the hard drive into the removable hard drive carrier by the screws which provided in the accessory pack. 8 x 6#-3 screw Hardware Installation Procedure 4

Connecting SR611 to your computer 1. Connect DC1V&4V power cables and cables to SR611.. Secure RS3 set on the SR611 machine 3. Connect SR611 to the motherboard COM 1 with RS3 cables which included in the accessory pack as shown in the picture. 45cm Cable 1 +5V GND +1V FAN RS3 3 1 Power Supply Connector Internal RS3 Cable 3 Real Panel 1 45cm Cable Power Supply SR611 Power Supply Connector COM 1 COM Internal RS3 Cable 3 4 Motherboard 1 Ports External RS3 Cable 4 3 Internal Case 1. We do not recommend users to disassemble the machine without proper instructions and authorization. The manufacture warranty will not cover damage caused by unauthorized disassembling.. If exchange the parts of SR611 is absolutely necessary, please refer to the diagram in the user s guide. 5 Connecting SR611 to your computer

Setting the Hard Drive Array Mode Installing two brand new hard drives 1. Place two new hard drives into SR611 at the same time.. Use the disk monitoring software in the operating system to partition and format the hard drive after turning the machine on. At this point, SR611 will be treated as a single hard drive. If hard drives with different storage capacity are installed, SR611 will automatically detect the storage capacity of each hard drive, and will treat the hard drive with larger storage capacity as the same capacity of the hard drive with smaller storage capacity. 3. Install RAIDGuide (Windows User) Installing a brand new hard drive and a hard drive with existing data Internal RAID module is suggested to be used for OS backup data. We highly recommend using the same brand of hard drives with the same or larger storage capacity when installing hard drives to SR611. The user can use the auto rebuilding function to automatically format the new drive and subsequently to back up the data into the new hard drive. 1. Place the hard drive with existing data into slot 1 or in the SR611.. Since one of the slots is empty, the buzzer will alarm user about the empty slot when the computer is turned on. To shut off the buzzer alarm, just push the bottom located in the front display screen. 3. After turning on the operation system, please check whether the current SR611 setting is the same prior to hard drive installation. Then place the new hard drive in the removable hard drive carrier into another slot. Note: the storage capacity of the newly installed hard drive must be larger than or equal to the old hard drive. 4. The SR611 will start the auto rebuilding function shortly after. 5. Please press the Buzzer bottom after auto rebuilding to reset the buzzer alarm and to return the system operation normally. 6. If you use this install method and backup OS at the same time, please make sure that the system is installed normally, in case of error or OS backup failure. Setting the Hard Drive Array Mode 6

Computer Set Up When the hardware setup for SR611 is complete, you are now ready to turn the machine on. 1. After the hardware installation is complete, the SR611 will be treated as one single hard drive. Set the hard drive to AUTO in the computer s BIOS. When the computer is turned on, the system will retrieve the following information:. In SR611, the installed hard drive can be detected by the Device Manager of Computer Management for Windows 3. Customers can choose to format the hard drive by using the Disk Management tool of the operating system before using the SR611 At this point, the installation process is completely finished. The user can freely retrieve and save data to SR611 just like retrieving and saving data to a regular hard drive. If the user experiences any abnormality during the operation, please refer to the trouble shooting Q&A section in Appendix. 7 Computer Set Up

Hard Disk status on LCD screen Left Hard Drive (Primary Hard Drive) Fail Right Hard Drive (Secondary Hard Drive) Normal Pri HDD : Fail Sec HDD : OK Primary hard drive storage capacity larger than secondary hard drive Wrong Capacity PRI>SEC Secondary hard drive storage capacity larger than primary hard drive Wrong Capacity SEC>PRI Hot Swap & Auto Rebuilding The hard drive Hot Swap and Auto Rebuilding functions are available. The Hot Swap & Auto Rebuilding functions are applicable in: 1. Off-line Back up When the data is stored within SR611, the user can remove one of the hard drives from SR611 as back up drive for data such as system operation file, secured files, seldom modified files or image and music files. The user can periodically insert the hard drive back into SR611 to execute automatic backup to protect the system from being hit by computer virus or to avoid risk of having both hard drives failing at the same time.. During the Hard drive Failure When one of the two hard drives fails in the SR611 system, the system will alarm the hard drive failure message both on the LCD display screen and in the monitoring software. The user can remove the failed hard drive from the system while the system is still in operation without shutting down the machine. If the failed hard drive is replaced shortly, the system will automatically execute the Auto Rebuilding function without affecting the system operation and without any operation command from the user. Hard Disk status on LCD screen 8

The LCD Display Message During Hot Swap and Auto Rebuilding When the SR611 detects a hard drive missing or a hard drive failure, the Buzzer will go off and the LCD display screen will display the following messages: Pri HDD : OK Sec HDD : Fail Pri HDD : Fail Sec HDD : OK 1. After removing the failed hard drive and replacing with a new hard drive, if the hard drive is properly installed, the LCD display screen will display the following messages: Pri HDD : OK Sec HDD : OK. After few seconds of installing the new hard drive, the LCD display screen will display the data rebuilding progress: Rebuilding Pri->Sec XXX% Rebuilding Sec->Pri XXX% Pri->Sec represents that the data in the original hard drive (primary hard drive) is copied to the new hard drive (secondary hard drive). XXX % represents the rebuilding completion percentage. 3. When the rebuilding is fully completed, the LCD display screen will again display the following messages: Pri HDD : OK Sec HDD : OK 4. When SR611 is overheating, "T" will be displayed on the upper right-hand corner of screen (As shown in illustration) Pri HDD : OK Sec HDD : OK T 5. When cooling fan module is not functional, "F" will be displayed on the lower right-hand corner of screen. (As shown in illustration) Pri HDD : OK Sec HDD : OK F 9 Hard Disk status on LCD screen

Appendix:Trouble Shooting / Q&A Unstable system after connecting SR611 Q: After installing SR611, we are unable to start the computer or the computer can not locate SR611 upon startup. A: 1. Please check whether the readings on the SR611 LCD display screen appear normal.. Please check whether the Cable connection cables are properly connected to the computer system and whether drives are functioning normally. 3. If everything is functioning properly but the user still can not start the computer system, then the problem might be the system incompatibility. If such incompatibility takes place, please contact our technical support department. Q: When the SR611 is in use, the computer system is functioning normally but the SR611 access speed is abnormal. A: Please first check whether the SR611 is in the progress of executing data auto-rebuild. 1. Please examine if the length of the connection cables, cable that connect the drives to the computer system is too long and whether the specification these cables complies with the requirements.. If both the lengths and specification of the cables are checked out ok, please turn off SR611 and remove the hard drive from SR611. Test the hard drive directly with the computer system since it might be the bad sectors in the hard drive that are causing the longer than normal system down time. Hard Drive Failure Q: Under the mirror mode (RAID 1), what will be the system s total storage capacity when adding a brand new hard drive? A: 1. The total storage capacity for SR611 is determined by the storage capacity of the primary hard drive installed during the initial usage.. The storage capacity will not increase after initial installation even when place a brand new hard drive with larger storage capacity. Q: Why does the error message appear when I installed the second hard drive? A: 1. The storage capacity of the second hard drive must be larger than the first hard drive. Otherwise, SR611 can not rebuild the new hard drive and the LCD display screen will display Wrong Capacity.. The LCD display screen might display rebuilding error messages such as Pri(s)->Sec(s) or Sec(s)->Pri(s). The term (s) signifies that both hard drives are treated as original hard drive. The user must determine which hard drive will be the original hard drive prior installing the hard drives into SR611. Once the original hard drive is designated and installed in SR611, the user can place in the second hard drive by taking advantage of SR611 s Auto Rebuilding function. Q: My hard drive is obviously operating properly but why is it shown as failed in the SR611 display? A: SR611 uses more strict requirements and standards to examine the bad sectors in the hard drive. The user can first overwrite the bad sector on a PC before placing the hard drive into SR611. Appendix:Trouble Shooting Q&A 10

About Auto Rebuilding Function Q: What will happen if we turn off the computer s power while SR611 is still executing data auto rebuilding? A: Under the mirror mode (RAID 1), if the power is out of the auto rebuilding process, the controller will remember when completion percentage of the auto rebuilding process and resume the rebuilding process when the power is back on. Q: Is it possible to lose any part of the data during the data auto rebuilding? A: The data auto rebuilding function will copy data from one sector to another sector. Technically speaking, the data will not be lost during the auto rebuilding process. However, if the original hard drive is detected with bad sectors during the rebuilding process, SR611 will make hypothetical duplication instead of treat the bad sectors as hard drive failure. Therefore, the data stored in the bad sectors could potentially be lost during rebuilding. Q: Under the mirror mode (RAID 1), why does the computer slows down during the data rebuilding process? Or why does the data rebuilding process slows down when the data is being processed? A: If the SR611 system is executing data rebuilding simultaneously while the computer system is saving the data, the auto rebuilding process and the saving process will take longer than normal time. This is because the SR611 must divide it s resource between the normal system operation and the data rebuilding process. However, the priority for the SR611 is to maintain the proper system operations. Therefore, the data rebuilding speed will be extremely slow until the system finished with the data saving operations. Other Possible Situations Q: The Buzzer will not stop when the SR611 is in operation. A: Please check whether the readings on the LCD display are normal or if there is a hard drive failure. Please also pay attention to any other symbols displayed in the LCD display. For example, if the F symbol is displayed, this means that there is a cooling fan failure. If the T symbol is displayed, this means that the system is overheated. Q: How to turn on and off the Buzzer? A: 1. The manufacture default setting for the Buzzer in SR611 is Buzzer On.. The user can use any pointed materials to push the bottom on the front dash board to turn on and off the Buzzer. 11 Appendix:Trouble Shooting Q&A