USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER MODEL : ARC2020

Similar documents
USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series

LBVR1718. Description. Features channel paperless recorder

DMT340 Series Dewpoint and Temperature Transmitters for Very Dry Conditions

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

SX 6000 Paperless Recorder

DMT345 and DMT346 Dewpoint Transmitters

Digital Indicator Solutions

F1000 User's Manual. (Version: V1.01)

Tempco Instruction Manual

Paperless Recorder. User s Manual KT200R IMA22-CP01

Conductive Level Controller

Microcontroller Based 8 CHANNEL Temperature/Process DATA LOGGER (Product Code 8.7 to 8.9)

PanelView Plus/VersaView CE Terminals and Display Modules

Dual channel temperature logger with two voltage inputs 0-5V Instruction Manual

1.6. Counters, Panel Meters, Tachometers and Timers. Contents Description Fusion Integrated Machine Control Standards and Certifications...

ESM H 77x35 DIN Size Heating Controller Digital, ON / OFF Temperature Controller

PR Series Paperless Recorders

DPR 100 A/B Analog Scales

Samba PLC+HMI SM35-J-RA22

Power Meter PowerMonitor 500

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

Temperature/Process Controllers Manual

SX90 Process Controller

VAT series controller and transmitter. Manual

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter

Network Instrumentation Module Communications box NX-CB1 Communications adapter NX-CL1/NX-CR1 Terminal adapter NX-TL1/NX-TR1

Scanner 2000 Steam Mass Flow Transmitter

Pulse concentrator, 12 inputs, 4 mod. DIN, with RS485 port

7511 / / / 711 / / 731 / Preset 27

User Manual Digi-Sense 12-Channel Benchtop Data Logging Thermocouple Thermometer

Saved Data playback Saved data in Memory card can be easily called out and played back on display

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

Meter Scanner & Controller

PTU300 Combined Pressure, Humidity and Temperature Transmitter

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

PCPR01 Paperless Recorder

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

Dual channel temperature logger with two binary inputs and LCD display Instruction Manual

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

Item SM35-J-TA22 SM43-J-TA22 SM70-J-TA22

Operating instructions. Speed monitor D / / 2014

TRACKER 220 SERIES. Digital Panel Indicators. A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature

The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

Operating Manual. Dynisco /8 DIN Indicator Concise Product Manual

HMISCU6B5 3 5 color touch controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

MICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS

Extruder Controls ExtruVision S

DPST-NO None 2 channels Auto-reset Inverse (+/-) 24 VAC/VDC 4 G9SB-2002-A 1 channel or 2

InteliLite MRS17 Click Here to Learn More

Trident and Trident X2 Digital Process and Temperature Panel Meter

ARF100 Paperless Recorder

Unitary Controller. Features. Description. Technical Specification Sheet Rev. 6, March, 2000

The Indicator with 3 Limit Contacts

MODCELL 2050R Single Loop Controllers

Operating instructions. Switching amplifier DN0210 DN / / 2015

GFC114. Low Power Flow Computer FEATURES

FEMA ELECTRÓNICA. Series BDF. LARGE DISPLAYS for parallel BCD code. USER S MANUAL (HT r190307) BDF-xx-BCD for parallel BCD code

Specification for temperature sensor calibration setup

- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS

FEMA ELECTRÓNICA. Series MAG983-X. COUNTERS for IMPULSE signals MAG983-1 MAG983-2 MAG983-3 MAG USER S MANUAL (HT0695-r050705)

Analog Input/Output Modules

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

/8 DIN Universal Process Indicator

Synergy Controller Application Note 1 September 2014, Revision F Tidal Engineering Corporation 2014

DATAWATCH IX MONITOR/RECORDER OVERVIEW FEATURES AND BENEFITS. Datasheet

LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E

6ES7212-1BD30-0XB0. permissible range, lower limit (DC) permissible range, upper limit (DC)

Color Printer Microjet Recorder Series

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

HygroFlex TF5 Temperature Transmitter. User Guide

SOUND LEVEL METER DVM1351 INSTRUCTION MANUAL HANDLEIDING MANUEL D UTILISATEUR DVM1351 SOUND LEVEL METER 1

Comprehensive Modular Genset Controller

mark150s mark150/485s DDC controllers Summary

MMT330 Series Moisture and Temperature Transmitters for Oil

Micro-Ohmmeters. Digital 10A. Models 6240 & Measure low resistance with high accuracy. Selectable test current and resistance ranges

TOP - 1. Instruction Manual. Version 1.0 Produced in Jan. 2004

HMT330 Series Humidity and Temperature Transmitters for Industrial Applications

User Manual. Rack Mount Display Monitor - 4K RMP-161-4K17. 7U 17.3 inch Rack Mount Display Monitor

Manual of Electrical Installation for Pressure Probes KS and KS-SIL2 series

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

TU531, TU532 Terminal Unit

Installation Manual INTELLIGENT SERVER. Model name: BMS-LSV6UL

VPINSTRUMENTS.COM VPFLOWSCOPE M. Your next step in gas flow measurement

Paperless Recorder VGR-B100. Series

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

Strip Chart Recorders Specification Sheet

In-Sight I/O. In-Sight expansion module (For use with in-sight 5000 series vision sensors and Id readers, and 3400 vision sensors)

V TU24 V350-J-TU24

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

THAYER SCALE. AUDiTORTM CONTINUOUS WEIGHING & FEEDING OF BULK MATERIALS. NTEP CERTIFIED Conveyor Belt Scale Monitor and Software package.

General information. Display. Supply voltage. Input current. Encoder supply. Output current

OPERATION MANUAL MODEL TT-LP

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

EX-RC1 Remote I/O Adapter

Transcription:

USER MANUAL MULTI COLOR MODEL : ARC2020 ACCSYS ELECTRONICS 140/6B, GOLDEN INDUSTRIAL ESTATE, JAWAHARLAL NEHRU ROAD, GERUGAMBAKKAM, CHENNAI - 600122 Tel: 044 60505599 / 60505511 E-mail : sales@accsyselectronics.com Page 1

WHEN YOU RECEIVE THIS INSTRUMENT... Thank you for purchasing the ACCSYS ELECTRONICS, ARC2020 MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER. Please read the instruction manual carefully and use the instrument correctly. ACCSYS ELECTRONICS assumes no liability to any party for any loss or damage, direct or indirect, caused by the use or any unpredictable defect of the product. Cleaning of the front panel should be limited to wiping lightly with a dry cloth. Check that all of the following items are present. Paperless Recorder Range Input Type Output indication Communication interface A pair of mounting bracket Operating Voltage Serial link cable between Recorder& PC Output. PEN DRIVE use after antivirus scanning INSTALLATION Installation Location Install the control panel in a location that meets the following criteria. (1) Little or no mechanical vibration. (2) No corrosive gases. (3) Minimal temperature fluctuations and near normal temperature. (4) Not directly subject to radiant heat. (5) Not subject to strong electromagnetic field. (6) No direct exposure to water. WIRING Wiring precautions While wiring take the following precautions. (1) Field wiring to the instrument, should be placed so as to avoid blocking the air flow, yet Provide a suitable service loop to allow easy removal of unit with wiring attached. (2) Wires should be tied to maintain an order in the event they must be disconnected for Any reason. (3) For connecting the wire to the terminals, we recommend use of crimp terminal lugs with Insulated sleeves. (4) Route the input circuit wiring away as possible from the power and ground circuits to avoid Noise pickup. (5) Use proper-shielded wire to avoid electromagnetic interference. Page 2

SPECIFICATION OF TOUCH SCREEN PROCESS DATA LOGGER : General Input Resolution: 0.1% of full scale. Input Channels: Maximum 16 channel direct universal input. Measurement Rate: 4 channels per second on all direct input channels Internal Temperature Reference : 0 to 60 C Thermocouple Resolution: 1 C or optional 0.1 C Reference junction compensation: Yes Type Range ( C) Accuracy ( C) J -200 to -100 C +/-2.5 C -100 to 1200 C +/- 1.5 C K -270 to -100 C +/- 2.5 C -100 to 1372 C +/- 1.5 C T -270 to -100 C +/- 2.5 C -100 to 400 C +/- 1.5 C E -270 to -100 C +/- 2.5 C -100 to 1000 C +/- 1.5 C N -270 to -100 C +/- 2.5 C -100 to 1300 C +/- 1.5 C S -50 to 1768 C +/- 3 C B 0 to 1820 C +/- 4 C RTD Base Accuracy: 0.2% or 0.5 C (1 F).Resolution: 0.1 C 2 or 3 wire connection. Cable compensation to +50 ohm. Open and short circuit detection. Type Range C Accuracy ( C) 100 ohm Pt. 385-200 to 400 C +/- 0.2 C Recording Recording Rates: User programmable from 1 sample per second to 1 sample every 10 hours Data Format:.Txt file; can be easily open able by variety of softwares. Data Storage Capacity:512 kb internal memory and this data can be Easily moved to memory stick connected to USB Port. Data Scaling and statistics : By PC Software Communication Specification Communication Output : RS 232 (or) RS 485 (or) USB (or) Ethernet (TCP/IP) Optional Advanced communication function provides high accuracy and stable multi-channel analog data sampling function to host computer. Also provides direct communication port to dot matrix printer and USB 2.0 pen drive option in the front panel of the Paperless Recorder. GPRS with SMS and Mail : Optional SMS : 5 Mobile Numbers with Low & High Alarm SMS After 30 minutes Email : 3 mail ID with Manual/ Auto mail Every day 12 AM Time Duration 1 hour per data Page 3

Power Requirements: 100 to 240 VAC, 50/60Hz. 20 VA max. Optional 24 VDC Power Fail Protection Programmed parameters stored in non-volatile memory. Clock battery backed. Clock battery to be replaced once in 5Years, one 3V Lithium cell easily replaceable. Transmitter Power supply Output: Optional isolated 24Vdc@120mA output Input / Output Relay Output : 2 relay outputs, (normally open, Close & pole contacts) rated at 30 VDC @ 0.5A or 230Vac @ 5Amp Max.Additional relay outputs (optional) : 12 Relay card; separate DIN rail Mounting Card interfaced with RS-232 or RS-485 interface with this unit Memory specification Internal memory: 20,000 Reading per channel. The data logger consists of internal memory storage capacity of above specified range provides a wide range of application in data storage for all channels individually Optional Higher Capacity Memory Internal memory: 2 4 GB for Higher Data Storage. Recording data on storage media Using the Setup menu, the user can log the data in internal memory. If this memory is full the logged data can be transferred to external storage media connected on USB Port. Record rate 8 channel 16 channel 1 Sec 9 Hrs 4.5 Hrs 10 Sec 90Hrs 45 Hrs 1 min 540 Hrs 270 Hrs 10 min 5400 Hrs 2700 Hrs The above table shows the number of maximum readings can be stored internal memory by changing record time After the above prescribed time the data must be transferred to USB storage media so as internal memory get free to store the new readings. Display Type: Color Active Matrix TFT Liquid Crystal Display Size: 8 inch diagonal, Resolution: 640 (W) x 480 (H) pixels Interface: Resistive analog touch screen control Display Modes: Graphic trending (horizontal), Bar Graphs( Vertical ) Digital Readout (Single or multi-channel), Alarms and event log settable. Historical trends: In PC Software. Display Windows: Time/Date, Graphics (bars, large digital, graph) Disk Status, System Status, Menu Button Bar, Alarms/ events Page 4

PC Based Software External PC software the user is able to manipulate the graph to make it easy to see interaction between recorded channels, or change the Color schemes, expand, compress, zoom and print. The same analysis tool used for multi-channel graph and used to scroll through data Optional : FDA Title 21 CFR Part 11 Compliant Software & Web server Based Software Safety and Environmental Operating Range: 0 C to 60 C, 10% to 90% RH non-condensing Dimension: Bezel dimension - 195(H) x 300(W) x 5mm above panel. Unit dimension : 195 ( H) x 300 (W) x 75 ( D) mm depth. Panel Cut out : 175 ( H) x 255(W) mm Protection : IP65 for front bezel when mounted in panel. Safety : Meets the requirements of EN61010-1 when installed in accordance with the instructions in the Manual. UL and c UL : Pending EMC : Meets the requirements of EN61326 and CE directive 89/336/EEC & EN12830 Weight : Approximately 3.0 kg. Recorder Dimensions Panel Cut out Page 5

Page 6

OPERATING PARAMETER SETTING Switch ON the device, the following display will show the channel readings. It will take a few seconds. CONFIGURATION SETTING Click CONFIG in the display, Enter the password to progress into the Setting Screen. Page 7

After entering the password, the setting screen will be displayed as shown below TIME & DATE SETTINGS In Setting -> SET Real Time Clock, Set the real time & date details. Click OK to save the settings. Page 8

LOG TIME SETTINGS In Setting -> SET Log Time, Set the Log Time Of The Logger. Click Ok to save the settings. PASSWORD SETTINGS In Setting -> Click SET Password, this feature is used to change password of the user. Page 9

CHANNEL PARAMETER SETTINGS In Setting -> SET Channel Parameters, Select the Alarm Range, Offset, Decimal, Sensor and Channels. ALARM : Set the alarm range from the specified values. Low : -999 High : 9999 RANGE : OFFSET : Set the range with respect to the Sensor type specification.(ref PAGE NO:3) Set the offset range from -999 to 999, Default set 0 DECIMAL : Set the decimal point from 0 to 3 for Linear Inputs only ALARM INDICATION STATUS Once the alarm is ON the acknowledgement ( ACK) shows in GRAPH Key Alarm Status Normal High Low Display Color : BLACK : RED : BLUE Page 10

COPY MEMORY : Insert an USB 2.0 drive in the front panel of the Logger. In Setting -> Click COPY Memory, this feature is used to copy the Logger memory in to the Pen Drive. If USB 2.0 drive is not inserted in the drive, an error screen, PEN DRIVE PROBLEM!!! Will be displayed. ERASE : To clear the entire data from the Logger memory permanently, In Setting -> ERASE ALL!! Page 11

PRINT MEMORY : Insert an Ink jet printer through the PRINTER PORT provided in the back panel of Logger. In Setting -> Click PRINT Memory, the entire memory will be printed. GRAPH : After completing all the Settings, Click HOME icon in the Setting screen. Click GRAPH icon, to display the channel readings individually. Page 12

TERMINAL DETAILS: Input Terminal Power Supply Printer Port High & Low Alarm Communication port ID NUMBER : In Setting -> ID NUMBER SETTING for Multi Logger Software DATA LOGGING OFF Logging Off The Data Logger, Click HOME icon in the Setting screen In Setting ->DATA LOGGING OFF Page 13

MAINTENANCE Basic troubleshooting procedure The following questions should be asked & appropriate action is to be taken to the negative answers. All major corrective action can be accomplished by replacing the basic unit. No special tools are Required except screwdriver & multi meter. 1) When you switching ON the unit check whether the display is showing anything? If yes then go For step 2. If no check for the power input connections, check whether the unit is getting proper supply at proper terminals. Connecting the supply to the wrong terminals may damage the unit permanently. 2) Check the display whether it shows the actual value properly. If yes follow step 3,if no check the sensor Input; check whether the sensor or input is connected at proper terminals in proper way (+ve & -ve polarity). If sensor is open or not connected then 999.9" will appear on display. 3) After connecting the sensor if the actual value shown is not proper then check the calibration is Correct according to the calibration constant table. Page 14