Part No. Z , IA Mar OPERATION MANUAL. High Voltage Digitalmeter A

Similar documents
Part No. Z , IA Nov OPERATION MANUAL. High Voltage Digitalmeter A

Part No. Z , IA Jul OPERATION MANUAL. High Voltage Digitalmeter A

OPERATION MANUAL TOS5052 DANGER

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1

HV-CS kv Edge Mount Triaxial Jack

Model 8020-STC. Kelvin Standard Triaxial Connector Card. Description / October 2014 *P * 1

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Model 7705 Control Module

INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1

HI-POT TESTER. User s Manual

POCKET MULTIMETER Model No: MM18

Model 2657A-LIM-3 LO Interconnect Module

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

80W (16V/5A) Power Supply with USB Output. User Manual

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual

CVU-3K-KIT. 3 kv Bias Tee Kit. Description. Parts list / October 2014 *P * 1

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

ELV12 Series. Instruction Manual

OWNER S MANUAL 9908-TE. HIGH PRECISION AUTO-RANGING DC/True RMS AC BENCH-TOP DIGITAL MULTIMETER

High Precision Quad Output DC Power Supply

Model R5010. TRMS Digital Multimeter. Instruction Manual

2260B-RMK-Series Rack Mount Kit

DM3058/DM3058E Digital Multimeter

Model 8010 High Power Device Test Fixture Interconnection Reference Guide

Model 2600B-PM V Protection Module with 1 A Clamp. Description / April 2015 *PPA * 1

BENCH-TOP DIGITAL MULTIMETER INSTRUCTION MANUAL

Model INSTRUCTION MANUAL DIGITAL MULTIMETER

CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1

ETHOS Auto Ranging Digital Multimeter

General Warranty. For more details, please refer to the user manual on the supplied CD, it can also be downloaded at

HI-POT TESTER User Manual

Models 2601B, 2602B, and 2604B System SourceMeter Instruments Quick Start Guide

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX310

User Guide True RMS Multimeter Extech EX205T

Digital Multimeter User's Manual

Model 2380 Rack-Mount Kit

User's Guide. MiniTec TM Series Model MN25 MultiMeter

AutoRanging Digital MultiMeter

User s Manual Power Supply IM E. 5th Edition

7032 Digital-Analog Multimeter

9040/9040UK. Users Manual. Phase Rotation Indicator

Mini Digital Multimeter

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

AC Power Meter GPM-8212 USER MANUAL

Single Kernel Grain Moisture Tester PQ-520. (type PQ ) Operating Instructions

Model R5010. Instruction Manual. TRMS Digital Multimeter. reedinstruments www.

User's Guide. Extech AM A AC Analog Clamp Meter

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

Autoranging Mini Multimeter

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

DC POWER SUPPLY. Model: PW-3063R / PW-4063R

User's Guide. Digital Multimeter. Model MN42

TT-SI 50 50MHz DIFFERENTIAL PROBE USER S MANUAL

OPERATING INSTRUCTION

1-36V, 0-3A DC Power Supply

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

38 MHz Passive Voltage Probe R&S RT-ZP1X

Mini Digital Multimeter

3700 SERIES USER MANUAL

Model 2380 Rack-Mount Kit

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

Table of Contents Product Overview Before using the product Installation Procedure... 5

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

700 Series 200 Amp Clamp Meters

SDM120 SERIES. SDM120 series User Manual. Single phase two wire DIN rail energy meter (One module)

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español

Operating instructions. Standstill monitor A / / 2011

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

OPERATING MANUAL FOR THE 30KV A.C. TEST SET P123. Bicotest High Voltage Products Ltd

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

LINE VOLTAGE TESTER CT101 USER S MANUAL. Please read this manual carefully and thoroughly before using this product.

General Warranty. For more details, please refer to the user manual on the supplied CD, it can also be downloaded at

Autoranging True RMS Multimeter User Manual

MARTINDALE INSTRUCTIONS MM35 DIGITAL MULTIMETER ELECTRIC. Trusted by professionals

PCT2000. User Manual. Precision current transducer 2000 A

Operating instructions. Speed monitor D / / 2014

ELECTRICAL SUPPLY TROUBLESHOOTING QUICK GUIDE SAFETY PRECAUTIONS

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

Mini Digital Multimeter Model MN15. User's Guide

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

* * Agilent Power Distribution Unit (PDU) Installation Guide

Digital Clamp Meter User Manual

User s Guide. 600A AC Clamp Meter. Model 38387

Laboratory Switch Mode Power Supply Series. Instruction Manual

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA. GE Critical Power

EC Series. Safety Guide

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

NIR Moisture Analyzer KB-30

IDEAL INDUSTRIES INC. TECHNICAL MANUAL MODEL:

Universal AC Power Source + AC Power Analyzer

CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL

Tesla TI Generator Set Interface

DRT-301 A/D. User manual. Three phase four wire DIN rail energy meter. (Seven modules) 1.1 Safety instruction. 1.2 Foreword. 1.3 Performance criteria

WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL

Model A Mini AC/DC Clamp Meter. User's Guide

PRO1250D CT MID DIN rail three phase four wire energy meter. User manual Version 1.5

PRO-1250D CT MID DIN rail three phase four wire energy meter.

Transcription:

Part No. Z1-109-820, IA001704 Mar. 2011 OPERATION MANUAL High Voltage Digitalmeter 149-10A

Use of Operation Manual Please read through and understand this Operation Manual before operating the product. After reading, always keep the manual nearby so that you may refer to it as needed. When moving the product to another location, be sure to bring the manual as well. If you find any incorrectly arranged or missing pages in this manual, they will be replaced. If the manual gets lost or soiled, a new Operation Manual can be purchased. In either case, please contact your Kikusui agent, and provide the "Kikusui Part No." given on this page. This manual has been prepared with the utmost care; however, if you have any questions, or note any errors or omissions, please contact your Kikusui agent. All or any parts of this manual may not be reproduced in any forms, without express written permission of Kikusui Electronics Corporation. The contents of this manual, including the specifications of the instrument, are subject to change without notice. Copyright 1994-2011 Kikusui Electronics Corporation.

Power Requirements of this Product Power requirements of this product have been changed and relevant sections of the Operation Manual should be revised accordingly. (Revision should be applied to items indicated by a check mark.) Input voltage The input voltage of this product is Vac, and the voltage range is to Vac. Use the product within this range only. Input fuse The rating of this product's input fuse is A, Vac, and. WARNING To avoid electrical shock, always disconnect the power cord or turn off the switchboard before attempting to check or replace the fuse. Use a fuse element having a shape, rating, and characteristics suitable for this product. The use of a fuse with a different rating or one that short circuits the fuse holder may result in fire, electric shock, or irreparable damage. 149-10A 1

Power Requirements of this Product (cont'd) Power cord The product is provided with power cords described below. If the power cord has no plug, attach a plug or crimp -style terminals to the power cord in accordance with the wire colors specified in the drawing. WARNING The attachment of a plug of power cord or crimp-style terminals must be carried out by qualified personnel. Without a plug Blue (NEUTRAL ) Brown (LIVE) Without a plug White (NEUTRAL) Black (LIVE) Green/Yellow (GND) Green or Green/Yellow (GND) Plug for USA Plug for Europe Plug for China Provided by Kikusui distributor/agent Kikusui agents can provide you with suitable power cord. For further information, contact Kikusui distributor/agent. 2 149-10A

Safety Precautions The following safety precautions must be observed to avoid fire hazard, electrical shock, accidents, and other failures. Keep them in mind and make sure that all of them are observed properly. Operation Manual Users This product must be used only by qualified personnel who understand the contents of this operation manual. If it is handled by disqualified personnel, personal injury may result. Be sure to handle it under supervision of qualified personnel (those who have electrical knowledge.) This product is not designed or manufactured for general home or consumer use. Purposes of use Do not use the product for purposes other than those described in the operation manual. Line Voltage Input power Use the product with the specified input power voltage. For applying power, use the AC power cord provided. Note that the provided power cord is not use with some products that can switch among different input power voltages or use 100 V and 200 V without switching between them. In such a case, use an appropriate power cord. For details, see the relevant page of this operation manual. Fuse With products with a fuse holder on the exterior surface, the fuse can be replaced with a new one. When replacing a fuse, use the one which has appropriate shape, ratings, and specifications. 149-10A 3

Cover There are parts inside the product which may cause physical hazards. Do not remove the external cover. L N G Installation When installing products be sure to observe "Precautions for Installation" described in this manual. To avoid electrical shock, connect the protective ground terminal to electrical ground (safety ground). When applying power to the products from a switchboard, be sure work is performed by a qualified and licensed electrician or is conducted under the direction of such a person. When installing products with casters, be sure to lock the casters. Relocation Turn off the power switch and then disconnect all cables when relocating the product. Use two or more persons when relocating the product which weights more than 20 kg. The weight of the products can be found on the rear panel of the product and/or in this operation manual. Use extra precautions such as using more people when relocating into or out of present locations including inclines or steps. Also handle carefully when relocating tall products as they can fall over easily. Be sure the operation manual be included when the product is relocated. 4 149-10A

Check? Operation Check that the AC input voltage setting and the fuse rating are satisfied and that there is no abnormality on the surface of the AC power cord. Be sure to unplug the AC power cord or stop applying power before checking. If any abnormality or failure is detected in the products, stop using it immediately. Unplug the AC power cord or disconnect the AC power cord from the switchboard. Be careful not to allow the product to be used before it is completely repaired. For output wiring or load cables, use connection cables with larger current capacity. Do not disassemble or modify the product. If it must be modified, contact Kikusui distributor/agent. Maintenance and checking To avoid electrical shock, be absolutely sure to unplug the AC power cord or stop applying power before performing maintenance or checking. Do not remove the cover when performing maintenance or checking. To maintain performance and safe operation of the product, it is recommended that periodic maintenance, checking, cleaning, and calibration be performed. Service Internal service is to be done by Kikusui service engineers. If the product must be adjusted or repaired, contact Kikusui distributor/agent. 149-10A 5

Safety Symbols This operation manual and this product use the following safety symbols. Note the meaning of each of the symbols to ensure safe use of the product. (As using symbols depend on the product, all of symbols may not be used.) or WARNING CAUTION NOTE Description Indicates the presence of 1000V or higher. Inadvertently touching such a part may cause electrical shock resulting in death. If it is necessary to touch such a part to conduct work, first make sure no voltage is being supplied. Indicates the possibility of personal injury or death. Never fail to follow the operating procedure. Do not proceed beyond a WARNING sign until the noted conditions are fully understood and met. Indicates the existence of damage to the product or connected equipment. Always follow the operating procedure. Do not proceed beyond a CAUTION sign until the indicted conditions are fully understood and met. Indicates additional information such as operating procedure. Describes technical terms used in this manual. Indicates action prohibited. Indicates general warning, caution, risk of danger. When this mark is indicated on the product, refer the relevant section of the Operation Manual. Indicates a grounding (earth) terminal. Indicates a chassis grounding terminal. 6 149-10A

Contents Power Requirements of this Product 1 Safety Precautions 3 Safety Symbols 6 Chapter 1 GENERAL DESCRIPTION 8 Chapter 2 PRECAUTIONS 9 2.1 Receiving Inspection 9 2.2 Notes for Use 9 Chapter 3 OPERATION METHOD 11 3.1 Description of Front Panel 11 3.2 Description of Rear Panel 11 3.3 Description of Side Panel 11 3.4 Measuring Method 12 Chapter 4 SPECIFICATIONS 15 Chapter 5 CALIBRATION 16 5.1 Calibration of Digitalmeter 16 Chapter 6 BLOCK DIAGRAM 17 149-10A 7

Chapter 1 GENERAL DESCRIPTION Kikusui Model 149-10A High Voltage Digitalmeter measures AC and DC voltages of up to 10 kv, with a high accuracy. As the meter input impedance is as high as 1000MΩ, the meter is best suited for measurement of voltages of high source impedance circuits. The meter is compact and light (approx.3kg), but its measuring accuracy is high. Thus the meter can also be used conveniently as a portable calibration instrument or to calibrate the voltage of a withstanding voltage tester. 8 149-10A

Chapter 2 PRECAUTIONS 2.1 Receiving Inspection Immediately upon receipt of the device, inspect it for any damage which might have been sustained while in transportation. If any signs of damage are found, contact Kikusui distributor/agent. 2.2 Notes for Use 1. Be sure to connect securely between the meter and the measured voltage source with the supplied cord. Note that, if the ground line is accidentally disconnected while the high voltage is being applied, electric shock hazards may be caused or the meter may be seriously damaged. 2. Be sure to connect the LOW terminal (Protective grounding terminal) on the front or rear panel of this meter to a good earth ground. If the meter is connected to the measured voltage source without earth-grounding and, moreover, if the low voltage line and high voltage line are wrongly connected, the instrument may be damaged irretrievably. Example of bad connections Model 149-10A No earth ground A B Measured object Earth ground High voltage cable A: High voltage side B: Low voltage side Fig. 2.1 149-10A 9

If the 149-10A is earth-grounded in the above bad example, terminals A and B of the measured object are shorted through the earth-ground and the measured object is adversely affected. In order to prevent this, be sure to earth-ground securely the 149-10A and to identify correctly the high voltage and low voltage lines of the measured object (refer to 3.4.1 Measuring Procedure) and to make connections correctly and securely. 3. Use the instrument within the specified ambient temperature and humidity ranges with Section 4 Specifications. 4. Calibrate the meter once a year or more frequently. 5. If the meter is used in dusty atmosphere or the meter is used continuously for a long time with a high voltage being applied, dust may be collected on the high voltage terminal section. Because input resistance degradation or voltage dividing ratio disturbance, clean at appropriate intervals the high voltage section and the internal insulators using a clean, dry cloth. 6. The AC/DC converter of this meter is a mean-value response system and is calibrated with the rms value of sine wave. Note, therefore, that errors may be caused if the measured voltage waveform is largely different from sine wave. 10 149-10A

Chapter 3 OPERATION METHOD 3.1 Description of Front Panel [Digital Voltmeter] Indicates the measured voltage. NB00447-1 kv INPUT MAX10kV CAUTION HIGH VOLTAGE [AC/DC SW] Selects measuring mode between AC and DC. AC, DC lamps (LEDs) Indicate selected mode. [POWER SW] AC main power switch. [INPUT] Terminal for high potential line of measured input Voltage.. Fig.3-1 [LOW Terminal] Terminal for ground line of measured input voltage. 3.2 Description of Rear Panel Protective grounding terminal: For grounding the casing to the earth. Fuse: 0.5 A fuse 3.3 Description of Side Panel CALIBRATION (AC/DC): Semi-fixed resistors for calibration of AC and DC voltages, respectively. Do not touch these resistors except when calibrating the instrument. 149-10A 11

3.4 Measuring Method 3.4.1 Measuring Procedure 1. Connect the protective grounding terminal of the rear panel to a good earth ground. Note that, unless the LOW terminal is securely connected to the earth, a hazardously high voltage will be induced on the casing when the ground line from the measured voltage source is disconnected accidentally. Be sure to check the earth ground when using this instrument. 2. Connect the AC power cord to an AC power line outlet of the correct voltage, and turn ON the POWER switch. To measure with highest accuracy, warm up the 149-10A for at least 15 minutes. 3. Securely connect the LOW terminal of the front panel to the low line of the measured voltage source using the cord (supplied). 4. Insert the end of the HIGH VOLTAGE cord (supplied) for a sufficient length in the INPUT terminal on the front panel, and securely fix the cord with the plastic screw (supplied). Note that serious hazards can be caused if the HIGH VOLTAGE cord is accidentally disconnected while in measurement. For measurement of 5 kv or higher voltage, be sure to use the HTL2.5DH. 5. A typical method of identifying the low voltage line (the GND line) when it is unknown which one of the two lines of the measured object is shown in the following: Connect the high voltage cable to terminal A and then B as shown in Fig. 3.1. The terminal which presents a voltage higher than the other can be construed to be the high voltage line and the other to be the GND line. 12 149-10A

Model 149-10A A B Measured object Earth ground Fig. 3-2 High voltage cable After the high voltage line and low voltage line are identified as above, make complete connections of the cables as shown in Fig. 3-3 and, then, measure the voltage. Model 149-10A A B Measured object Earth ground Earth ground Securely ground the low voltage side to a good earth ground. Fig. 3-3 High voltage cable Note: For the 149-10A Digitalmeter, grounding may be done via the protective grounding terminal on the rear panel. 149-10A 13

6. Set the AC/DC selector switch in accordance with the measured voltage. The meter will not be damaged even if a voltage is measured with a wrong setting of this selector switch, although the meter does not indicate the correct voltage. 7. Connect the high voltage cable of the instrument to the high voltage line of the measured voltage source. The meter will digitally indicate the measured voltage. 8. Turn ON the power of the measured voltage source. 3.4.2 To Correct the Meter Reading for High Impedance Voltage Source The meter input impedance is very high (1000MΩ). When the voltage source impedance is substantially high, however, errors can be caused. In such a case, make correction calculation as follows: E = Eo 1+ o 1000M ( ) where, E : True voltage Eo : Meter reading γo : Source impedance of measured voltage In most cases the value of source impedance (go) is unknown. In such cases, use the above equation as follows: When γo 10 MΩ for example, Eo < E 1.01 x Eo As above, when the source impedance is lower than 10MΩ, the error caused impedance-wise is less than 1%. Measurement can be done with an accuracy of this error plus meter accuracy. 14 149-10A

Chapter 4 SPECIFICATIONS Item Specification Power requirements 100V±10%, 50/60 Hz AC, approx. 10VA Measuring ranges 0.500 to 10.000 kv AC/DC AC: ±(1% of rdg + 0.05% of range) DC: ±(0.5% of rdg + 0.03% of range) Measuring accurancies at 23 C±10 C *(for sine wave, at 50 to 60 Hz) AC : 11kV rms (sine wave, 50 to 60 Hz) Maximum allowable DC : ±14 kv input voltages Pulse : 15 kv peak Display 7-segment LEDs Double integration type. For AC measurement, mean value response, sine wave Type of voltmeter rms value calibration. Input resistance Ambient temperature and humidity: 3 samples/sec 0 C to 35 C (32 C to 95 C), 80% RH External dimensions : Overall Dimentions Maximum dimensions: Weight Approx. 3 kg (6.6 lbs) 1 set AC power cord 1 Accessories High voltage test cords (TL05-TOS) 1 HTL2.5DH 1 Operation manual 1 149-10A 15

Chapter 5 CALIBRATION 5.1 Calibration of Digitalmeter 1. Instruments Required for Calibration To calibrate the 149-10A covering its all measuring ranges, a standard voltage generator which will provide the following voltages is required. AC: 10 kv ± 0.1% DC: 10 kv ± 0.05% If you cannot prepare an above standard voltage generator, calibrate the 149-10A with a calibrator which can generate the voltage range which you use, or order your KIKUSUI agent for calibration. 2. Notes before calibration (a) As a high voltage of 10 kv is dealt with when calibrating the 149-10A, pay full attention for safety. (b) Before calibration, warm up the 149-10A for at least 60 minutes. 3. Set the 149-10A in the DC mode, apply a calibration voltage of 10 kv DC to the input terminal of the 149-10A, and so adjust CALIBRATION (DC) semi-fixed resistor on the side panel of the 149-10A that it displays 10.000. Next, set the 149-10A in the AC mode, apply a calibration voltage of 10 kv AC, and so adjust the CALIBRATION (AC) semi-fixed resistor that the 149-10A displays 10.000. When doing this, the displayed value may change by about three digits. For calibration, use the center value. When adjustment for DC measurement is done, the voltage dividing ratio of the input circuit varies. Be sure to perform the DC calibration first. 16 149-10A

Chapter 6 BLOCK DIAGRAM 149-10A 17