Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Similar documents
Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F

4 Remote I/O. Digital Output Module 8-Channel Version Series 9475/ from Rev. F

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12

Ethernet CPU Module & Power Module for Zone 1 / Div. 1 Series 9441/12 and 9444/12

Operating instructions

CPU module for zone 2 Series 9442/35

Digital Input Output Module for Zone 1

5 Fieldbus Technology

Terminal Boxes Series 8118

Load Disconnect Switches and Motor Switches

Engineering Guideline. pac-carriers Type for Honeywell system Experion Series C I/O

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail

Fieldbus Isolating Repeater

PI-EX-ME-2NAM/COC-24VDC

Grounding Monitoring Device Series 8485

Assembly. Front view. LED yellow/red: Status output Ι/ Fault signal Function. Switch Power Rail

PI-EX-ME-2NAM/COC-120VAC

PHOENIX CONTACT - 12/2007

Control Buttons / Switches for Panel Mounting Series 8003

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Grounding Systems / Ground Monitoring Device Series 8146/5075 and 8125/5071

Grounding Monitoring Device Series 8485

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

SolConeX Wall-Mounted Socket, 16 A

Control Switches for Panel Mounting Series 8003

Linear Luminaire with LED Series EXLUX 6002/1 Version IIB+H2

MACX MCR-EX-SL-NAM-R(-SP)

MACX MCR-EX-SL-NAM-2RO(-SP)

Intrinsically Safe Explosion Proof Barriers

Linear Luminaire with LED Series 6012/5

Loop-powered Transmitter for Thermocouple Type K (NiCr-Ni)

MACX MCR-EX-SD LP(-SP)

PHOENIX CONTACT - 02/2008

Micro Limit Switch Series 8064

DeltaV Bulk Power Supplies

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Termination Board FC-GPCS-RIO16-PF. Features. Assembly. Function. Connection USIO/UPIO 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Termination Board. HiCTB08-SCT-44C-SC-RA. Features. Assembly. Function. Connection. 24 V DC (I), 24 V DC (II), Fault. Zone 0, 1, 2 Div.

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

Terminal Block Catalog Numbers 1719-TB6, 1719-TB6S, 1719-TB8, 1719-TB8S, 1719-TB8Sx2, 1719-TB8x2

Tubular Light Fitting with LED Series 6036

Cable End Boxes Series 8146

4 â Active barrier RN221N with optional HART diagnosis. Technical Information

Operating and monitoring systems Thin Client SERIES 500 Device platform EAGLE PM ET-556-TX

FB-6SP and FB-12SP. Block device couplers. Data sheet 3177_en_A. 2 Features. 1 Description

Operating and monitoring systems Panel PC SERIES 400 Device platform EAGLE PM ET-436-TX

Inductive sensor BI5-EM18-Y1X-H1141

Miniature Circuit-Breaker IEC Series 8562

Position Switches Series 8070

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur.

Inductive sensor BI1.5-EG08-Y1-H1341

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

FLEX Ex Spring Clamp Terminal Base

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X

Interface and Supply module. IPC 3x0i / PSC 3x0i

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

Inductive sensor BI1.5-EG08-Y1-H1341

Inductive sensor NI3-EG08K-Y1-H1341

INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur.

Operating and monitoring systems Operator Interface SERIES 300 Device platform EAGLE OS ET-306-FX

Linear Luminaire with LED Series 6412/5

DeltaV Bulk Power Supplies

Technical Data. General specifications. Rated operating distance s n 3 mm

D1093S INSTRUCTION MANUAL. D SIL 3 Relay Output Module with Line and Load diagnostics. DIN-Rail Model D1093S

Operating and monitoring systems Panel PC SERIES 400 Device platform EAGLE PM MT-436-TX

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

Barriers. EB3N Discrete Input Barrier with Redundant Output

Standard enclosure for Remote I/O Series 8150

Operating and monitoring systems Operator Interface SERIES 300 Device platform EAGLE PM MT-336-FX

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140

Emergency Luminaire for Fluorescent Lamps Series EXLUX 6009

Separating and protective. Separating and protective instruments. VEGATRENN 149AEx Separator type KFDO Barrier type Product Information

Magnetic Field Sensor for pneumatic cylinders BIM-INT-Y1X-H1141

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

SITOP in the SIMATIC Design

Operating and monitoring systems Operator Interface SERIES 300 Device platform EAGLE OS MT-316-TX

Operating instructions. Speed monitor D / / 2014

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X-H1141

Safety instructions VEGATOR 121, 122

Operating instructions. Switching amplifier DN0210 DN / / 2015

RSTI-EP Slice I/O. Digital Output Module

Isolating repeater IRU 420

MACX MCR-EX-SL-2NAM-T(-SP)

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

Ground Monitoring Device Series 8485

Digital Positioner 8049

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi

Intrinsically Safe Barriers

Transcription:

www.stahl.de > 4-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Additional Ex i control input for "Plant STOP" (acc. IEC61508 up to SIL2) > Line fault monitoring and LED display per channel > LED display for output signal per channel > Diagnostics based on NE107 > Module can be replaced in the hazardous area under power (hot swap) 15236E00 The Digital Output Module is used for connecting of up to 4 intrinsically safe solenoid valves, indication or signal elements to the IS1 Remote I/O system. The additional Ex i control input "Plant STOP" is used for safe switching off all outputs. All channels are individually monitored for wire breakage and short-circuit. The Ex i outputs are short-circuit proof, galvanically connected to each and galvanically separated from the system. Compatible spare for IS1 I/O modules: Series 9475/12-04-11, 9475/12-04-21, 9475/22-04-21 ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2 Ex interface x x x x x x Ex interface x x x x x x Ex interface x x x x x x Installation in x x x x Installation in x x x x Installation in x x x x x x WebCode 9475E Remote I/O /1

Explosion Protection Global (IECEx) Gas and dust IECEx DEK 12.0070X Ex ia [ia Ga] T4 Gb [Ex ia Da] I Europe (ATEX) Gas and dust DEKRA 12 ATEX0232X E II 2 (1) G Ex ia [ia Ga] T4 Gb Certifications and certificates Certificates Ship approval E II (1) D [Ex ia Da] I ATEX, IECEx, Brazil (INMETRO), India (PESO), Canada (cfm), Kazakhstan (TR), Russia (TR), Serbia (SRPS), USA (FM), Belarus (TR) ABS, CCS, ClassNK, DNVGL, LR, RINA, RS Further parameters Installation in Zone 1, Zone 2, Zone 21, Zone 22 and in the safe area Further information see respective certificate and operating instructions Safety data Design 9475/32-04-12 Max. voltage U o 19.7 V Output ia IIB / I Output ib IIB / I 142 ma 698 mw L o [mh] 1.3 1.1 0.5 0.2 0.1 0.05 C o [nf] 99 109 119 149 189 220 L o [mh] 7.5 5.0 2.0 0.5 0.2 0.1 0.05 C o [nf] 669 879 889 889 989 1189 1439 53.8 ma 617 mw L o [mh] 3.1 2.0 0.6 0.5 0.2 0.1 0.05 C o [nf] 109 109 119 119 149 189 220 L o [mh] 27 20 10 5.0 0.2 0.1 0.05 C o [nf] 499 609 869 899 1089 1189 1439 Max. internal capacity C i 11 nf (in the above tables, C i is subtracted from C o) Max. internal inductance L i negligible /2 Remote I/O

Explosion Protection Safety data Design 9475/32-04-22 Max. voltage U o 25.7 V Output ia IIB / I Output ib IIB / I 110 ma 708 mw L o [mh] 1.45 0.75 0.5 0.37 0.25 0.1 0.05 C o [nf] -- 56 67 76 93 95 95 L o [mh] 10 5 2.0 1.0 0.5 0.2 0.1 C o [nf] 323 323 333 393 473 633 783 49.5 ma 648 mw L o [mh] 1.5 1.0 0.86 0.5 0.37 0.2 0.1 C o [nf] 43 51 55 69 760 93 95 L o [mh] 24 20 2.0 1.0 0.5 0.2 0.1 C o [nf] 333 333 343 393 483 633 783 Max. internal capacity C i 7.2 nf (in the above tables, C i is subtracted from C o) Max. internal inductance L i negligible Ex i control input "Pant STOP" Connection terminals X3 1, 2 (without galvanic separation, 9475/22 compatible) Type of protection Ex ia Ex ia Max. voltage U o 5.1 V -- 0.44 ma -- 0.5 mw -- LO [mh] 100 10 2 1 0.2 0.01 -- CO [μf] 2.195 2.595 3.295 3.695 5.495 15.995 IIB / I LO [mh] 100 10 2 1 0.2 0.01 -- CO [μf] 9.995 12.995 16.995 19.995 31.995 159.995 Max. voltage U i -- 30 V Max. internal resistance R i -- 4940 Ω Max. internal capacity C i 5.2 nf (in the above tables, negligible C i is subtracted from C o) Max. internal inductance L i negligible negligible X3 3, 4 (with galvanic separation, switchable in parallel) Remote I/O /3

Selection Table Version Digital output module with "Plant STOP" Note Open-circuit voltage Max. output current Internal resistance Installation Order number Weight 17.9 V 40 ma 170 Ω Zone 1 9475/32-04-12 0.275 23.6 V 40 ma 287 Ω Zone 1 9475/32-04-22 0.275 Please order terminal separately - see Accessories kg Technical Data Electrical data Design 9475/32-04-12 9475/32-04-22 Ex i outputs Number of channels 4 4 Open-circuit voltage 17.9 V 23.6 V Output nominal current 40 ma 40 ma Internal resistance 170 Ω 287 Ω Rated operation U 11.3 V 12.3 V I 40 ma 40 ma Output characteristic 25 25 Ex i control input X3 Function Suitability Connection terminals 15285E00 "Plant STOP" to switch off all outputs Switch-off up to SIL 2 (IEC61508) X3 1, 2 (without galvanic separation, 9475/22 compatible) Supply voltage 3.3 V -- Internal resistance 20.5 kω -- Control voltage for all outputs OFF > 2.2 V < 1 V ( Plant STOP activated) Normal operation < 0.7 V > 6 V ( Plant STOP deactivated) Galvanic separation Test voltage acc. to standard EN 60079-11 Between auxiliary ) 1500 V AC power/system components Between two I/O ) 500 V AC modules Between I/O ) 500 V AC channels/system components Between I/O ) 500 V AC channels/ground (PA) Between I/O ) 500 V AC channels/"plant STOP" (X3 3, 4) Between "Plant ) 500 V AC STOP" (X3 3, 4)/ earth (PA) Electromagnetic compatibility U[V] 20 15 10 5 0 0 5 10 15 20 25 30 35 40 45 I[mA] Tested to the following standards and regulations: EN 61326-1 (2006) IEC 61000-4-1 6, NAMUR NE 21 U[V] 20 15 10 5 0 0 5 10 15 20 25 30 35 40 45 I[mA] 15286E00 X3 3, 4 (with galvanic separation, switchable in parallel) /4 Remote I/O

Technical Data Electrical data Electrical connection Power supply BusRail Types 9494 Ex i field signals Pluggable, blue terminals, 16-pole, 2.5 mm 2, screw or spring type version with lock Ex i control input Pluggable, blue terminal, 2-pole, 2.5 mm 2, screw type version with lock Auxiliary power Version Intrinsically safe Ex ia via BusRail Intrinsically safe Ex ia via BusRail Behaviour during all outputs "OFF" all outputs "OFF" undervoltage Max. current 210 ma 240 ma consumption Max. power 5 W 5.8 W consumption Max. power dissipation 4 W 4.5 W Device-specific data Settings Module Diagnosis ON / OFF messages Signal Line fault ON / ON without test current / OFF monitoring Test current 0.2... 0.28 ma Behaviour in case ON / OFF / hold last value of error Ambient conditions Ambient temperature -40 +75 C Storage temperature -40 +80 C Maximum relative 95 % (without condensation) humidity Semi-sinusoidal shock 15 g (3 shocks per axis and direction) (IEC EN 60068-2-27) Sinusoidal vibration (IEC EN 60068-2-6) Mechanical data Degree of protection (IEC 60529) Module enclosure Fire resistance (UL 94) Pollutant class Dimensions Indication LED indication Module requires maintenance Operating state Group error Channel error Channel status "Plant STOP" Function indication Retrievable parameters Error indication Module status and alarms 1 g in the frequency range 10... 500 Hz 2 g in the frequency range 45... 100 Hz IP20 polyamide 6GF V2 corresponds to G3 L = 128 mm, W = 96.5 mm, H = 67 mm LED "M/S", blue LED "RUN", green LED "ERR", red LED red, for each channel LED yellow, for each channel LED yellow ("Plant STOP" active, all outputs are high-impedance) Manufacturer, Type, hardware revision, software revision, serial number Internal bus error primer / redundant No response from IOM Configuration does not correspond to the module Hardware error Excess temperature Slot error Module requires maintenance Remote I/O /5

Technical Data Indication Error indication Signal errors for each channel Signal status bit "0" = output high-impedance / "1" = output is supplied Wire breakage > 10 kω ( with deactivated test current can be detected only if the output is switched on) output Short circuit output < 30 Ω (response range 30... 60 Ω) (can be detected only if the output is switched on) Mounting / Installation Mounting orientation horizontal or vertical (observe operating instructions) Mounting type on 35 mm DIN rail NS 35/15 (DIN EN 60715) Dimensional Drawings (All Dimensions in mm / inches) - Subject to Alterations 7mm 0.28 " 128,5 mm / 5.06 " 143 mm / 5. 63 " 154 mm / 6. 06 " 9 8 mm / 3.8 6 " 96,5 mm / 3.8 " 20 mm 0.79 " 68 mm / 2. 6 8 " 64 mm / 2.52 " 70 mm / 2. 76 " 10989E00 Accessories and Spare Parts Designation Figure Description Art. no. Pluggable terminal 02079E00 2.5 mm 2 with lock, 16-pole, screw connector, blue, for connecting the field signals to I/O modules, for intrinsically safe field circuits Labelling: 1... 16 Attention: An additional terminal is necessary for I/O module Series 9470 and 9480. Designation: 17... 32 162702 02077E00 2.5 mm 2 with lock, 16-pole, spring clamp connection, blue, for connecting the field signals to I/O modules, for intrinsically safe field circuits, incl. test jacks Labelling: 1... 16 Attention: An additional terminal is necessary for I/O module Series 9470 and 9480. Designation: 17... 32 162695 Electronic relay Model 9174/10-14-00 The electronic relay module 9174 is used to switch Ex e loads by using intrinsically safe control signals. input: Ex i output: 48 V / 2 A DC, Ex e 212340 Electronic relay Model 9174/10-15-00 The electronic relay module 9174 is used to switch Ex e loads by using intrinsically safe control signals. input: Ex i output: 250 V / 1 A DC, Ex e 212431 04036E00 LED indicating lamp Model 8010 LED indicator lamp for intrinsically safe circuits 8010/3-02, Ex i 237972 11403E00 /6 Remote I/O

Accessories and Spare Parts Designation Figure Description Art. no. Labelling strips "FB Addr... Mod No..." for pluggable terminal, sheet with 26 strips 162788 05869E00 DIN sheet For label plate on I/O modules; 6 labels on each sheet; print-out using IS Wizard; packaging unit = 20 sheets 162832 09900E00 Partition For mounting between intrinsically safe and non-intrinsically safe connections of the I/O modules, in order to adhere to the required 50 mm distance 220101 15196E00 Warning sign "Clean modules only with a damp cloth." 162796 Resistor error message suppression 05872E00 17310E00 The resistors are used to suppress error messages for unused I/O channels Resistance value: 5K6 / 0.5 W Suitable for: AIM 9468; DIOM 9470; DIOM 9471; DIOM 9472; DOM 9475 single electrical equipment for intrinsically safe circuits according to EN 60079-11 244911 We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. Remote I/O /7