HostEngine 5URP24 Computer User Guide

Similar documents
HostEngine 4U Host Computer User Guide

HostEngine 4U Host Computer User Guide

HostEngine 3U Host Computer User Guide

HostEngine 4U Host Computer User Guide

Xpander Rack Mount 16 5U Gen 3 with Redundant Power [Part # XPRMG3-1625URP] User Guide

Xpander Rack Mount 8 5U Gen 3 User Guide

Xpander Desktop Elite Gen 3 User Guide

Xpander Rackmount Elite Gen 3.0 User Guide

Chapter 6 Cubix SP1 Blade Server

DESERT STORM WS-TS700

ThinkServer RD450 Platform Specifications

High Performance Computing

AI Solution

Front-loading drive bays 1 12 support 3.5-inch SAS/SATA drives. Optionally, front-loading drive bays 1 and 2 support 3.5-inch NVMe SSDs.

Altos R320 F3 Specifications. Product overview. Product views. Internal view

Acer AR320 F1 specifications

NEC EXPRESS5800/R320a-E4 Configuration Guide

Capacity driven storage server. Capacity driven storage server

NEC Express5800/R120e-1M System Configuration Guide

NEC Express5800/R120d-2M Configuration Guide

Altos T310 F3 Specifications

Supports up to four 3.5-inch SAS/SATA drives. Drive bays 1 and 2 support NVMe SSDs. A size-converter

NEC Express5800/R120h-2M System Configuration Guide

ThinkServer RD630 Photography - 3.5" Disk Bay*

Cisco MCS 7828-I5 Unified Communications Manager Business Edition 5000 Appliance

B A. AW3000 Front View

(Please refer "CPU Support List" for more information.)

Suggested use: infrastructure applications, collaboration/ , web, and virtualized desktops in a workgroup or distributed environments.

Flexible General-Purpose Server Board in a Standard Form Factor

Cisco MCS 7835-H2 Unified Communications Manager Appliance

(Please refer "CPU Support List" for more information.)

Part Number Unit Descriptions

Acer AR320 F2 Specifications

RS500-E6/PS4. Configuration Guide

GPU-Xpander Product and Part Number Guide Q2 2016

TS700-E6/RS8. Configuration Guide

Cisco MCS 7825-I1 Unified CallManager Appliance

GW2000h w/gw175h/q F1 specifications

QuickSpecs. HPE Cloudline CL7100 Server. Overview

Acer AT310 F2 Specifications

CISCO MEDIA CONVERGENCE SERVER 7825-I1

Acer AW2000h w/aw170h F2 Specifications

NEC EXPRESS5800/R320b-M4 Configuration Guide

NEC Express5800/R120h-2E System Configuration Guide

M1034W Engineering Workstation

About 2CRSI. OCtoPus Solution. Technical Specifications. OCtoPus servers. OCtoPus. OCP Solution by 2CRSI.

NEC Express5800/D120h System Configuration Guide

Essentials. Expected Discontinuance Q2'15 Limited 3-year Warranty Yes Extended Warranty Available

About 2CRSI. OCtoPus Solution. Technical Specifications. OCtoPus. OCP Solution by 2CRSI.

ANNEX II + III : TECHNICAL SPECIFICATIONS + TECHNICAL OFFER

Intel Select Solutions for Professional Visualization with Advantech Servers & Appliances

System Configuration Guide

Data Sheet FUJITSU Server PRIMERGY CX2550 M1 Dual Socket Server Node

Acer AT110 F2 Specifications

(Please refer "CPU Support List" for more information.)

(Please refer "CPU Support List" for more information.)

Cisco MCS 7845-H1 Unified CallManager Appliance

Features. MIC-7700Q: 3 x independent displays (third display output via optional cable) MIC-7700H: 2 x independent displays Controller

(Please refer "CPU Support List" for more information.) (Please refer "Memory Support List" for more information.)

FWA-6280A User Manual 1. FWA-6280A User Manual

Integrated Ultra320 Smart Array 6i Redundant Array of Independent Disks (RAID) Controller with 64-MB read cache plus 128-MB batterybacked

Workstation Rack-Mount 4 RU Workstation, 4 RU Rack-Mount, Hexa-Core 3.5 GHz CPU, 16 GB DDR4 RAM, 256 GB SSD

NEC Express5800/B120f-h System Configuration Guide

IVH-9000 Series. 4K Isolated DIO

Dimensions. System Information. Memory. Stand mm (19.4 inches) mm (26.1 inches) Depth mm (1.4 inches) 78.2 mm (3.

Dual use as a high performance server and workstation

Chapter 2 BladeStation Enclosure

ESC2000 Configuration Guide

NEC EXPRESS5800/R320a-E4 Configuration Guide

EUR incl. 19% VAT, plus shipping. Intel WiFi, Intel WiDi! Dual Gigabit LAN! Gigabyte Features! NVMe M.2 slot!

Features. Q170: 3 x independent displays (third display output via optional cable) H110: 2 x independent displays Controller

The Why and How of Developing All-Flash Storage Server

EVS Series. Intel Xeon /Core i7/i5/i3 Fanless GPU Computing System with Intel C236 & NVIDIA GeForce GT K Isolated DIO.

HP ProLiant DL360 G7 Server - Overview

NEC Express5800/R120e-2E Configuration Guide

Part Number Class Category Title UPC Code Image Download Country of Origin Cost MSRP. Short Description. Long Description. Main Specifications

1U Device Expansion Unit Configuration Guide

ftserver 3300 Service Bulletin

Density Optimized System Enabling Next-Gen Performance

KEEX-7100 Series Single Board Computer in 3.5" ECX Form Factor with Intel Ivy Bridge Processors

Entry workstation with ultra-quiet and extreme I/O performance design. Up-to-date 22nm Processors, Latest Intel Platform Ready

Acer AT115 F1 Specifications

Sugon TC6600 blade server

CSU 0111 Compute Sled Unit

NEC Express5800/R120h-1M System Configuration Guide

CELSIUS R670 The new uncompromising high-end workstation

fit-pc Intense 2 Overview

Pegasus 5 Series. Ernitec Smart Backup. Massive Power. Optimized for Surveillance. Battery Backed 12Gbps Raid Controller.

Z370 PRO4. *8th Gen Intel CPU supports DDR4 up to Please refer to Memory Support List on ASRock's website for more information.

NEC EXPRESS5800/R320b-M4 Configuration Guide

Rack Systems. OpenBlade High-Density, Full-Rack Solution Optimized for CAPEX & OPEX

NVR-CV. Network Video Recorder Hot-Swappable Tray for 3.5 HDD x 4 or 2.5 HDD x 4 Gigabit Ethernet x 2 COM x 2, USB2.0 x 6. VGA x 1, DVI-D x 1

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.2

RS-200-RPS-E 2U Rackmount System with Dual Intel

High Density Computing for HPC Applications. Extreme High Density Computing Capability

CSU 0201 Compute Sled Unit

1. AMD Ryzen 2nd Generation processors 2. AMD Ryzen with Radeon Vega Graphics processors 3. AMD Ryzen 1st Generation processors

M1032W Engineering Workstation. The list below shows components included in an M1032W Engineering Workstation container.

New levels of efficiency and optimized design. The latest Intel CPUs. 2+1 expandability in UP 1U

Intel IP Network Server NSI2U

Transcription:

HostEngine 5URP24 Computer User Guide Front and Rear View HostEngine 5URP24 (HE5URP24) computer features Intel Xeon Scalable (Skylake FCLGA3647 socket) Series dual processors with the Intel C621 chipset. HE5URP24 supports up to 2TBytes error-correcting code (ECC) 3DS load-reduced, dual in-line memory module (RDIMM) memory or 1TByte ECC registered ECC DIMM memory. It provides 4 x PCI Express (PCIe) Gen 3.0 x16 expansion slots and 2 x PCIe Gen 3.0 x8 slots. Each x16 slot accommodates a full-height, full-length GPU. One x16 slot supports a double-wide GPU if one x8 slot is not populated. It also supports 2 x half-height, half-length, single-wide Cubix Host Interface Controller (HIC) that connects to Cubix Xpander Rackmount 8 and 1 or 2 x RAID controllers that connect to 24 x SAS hard disk drives (HDDs) or solid-state drives (SSDs). Each HIC connects to multiple slots within Xpander and each RAID controller connects to 24 x HDDs or SSDs within HE5URP24. To support the 24 x Serial-Attached SCSI (SAS with 12Gbits / second or 12Gbps transfer rate) 2.5 or 3.5 hot-plug hard-disk drives (HDDs) requires 1 x 24-port or 2 x 12-port SAS (12Gbps) RAID controller(s) in one or two of the 8 x slots. Each RAID controller port connects to a 4-port SAS backplane with a 1.0meter SFF-8643 mini-sas to SFF-8643 mini-sas HD cable, and in turn, each 4-port SAS backplane connects to 4 x SAS HDDs for a total of 24 x HDDs in each HE5URP24 and XPRM8G3-5URP24 chassis. The two chassis form a system with 48 x SAS HDDs. The total storage capacity is 48TBytes to 672TBytes, or 0.672PBytes, of direct-attached storage. It also provides 6 x rear-panel USB ports 4 x USB 3.0 and 2 x USB 3.1, a type A and a type C. HE4U also provides 2 x GbE network ports, one of which supports both local and remote management using IPMI 2.0. Each HE5URP24 and XPRM8G3-5URP24 also features a power supply with 3 + 1 hot-plug, redundant power modules and 4 x hot-plug cooling fans. Each is also rack-mountable with a tool-less access top cover. By connecting HostEngine 5URP24 to Xpander Rackmount 8 RP24, you can add up to 8 x double-wide GPUs such as NVIDIA Quadro P6000 to the HostEngine 4U computer for running Autodesk 3ds Max with NVIDIA iray or BlackMagic Design DaVinci Resolve for Linux or Windows. Cubix Corporation 2800 Lockheed Way Carson City, NV 89706-0719 Page 1 Sales 800.829.0550 http://www.cubix.com sales@cubix.com he5urp24-x11dai-n-12g20181016

HostEngine 5URP24 Technical Specifications Central Processing Unit (CPU) Intel Xeon Scalable Processor Series Number CPUs 2 with identical revision, core voltage and bus (core) speed Sockets 2 x Socket P LGA 3647 Speeds / Cores / Threads 1.8 3.5GHz / up to 28 cores / up to 56 threads Intel Smart Cache Up to 38.5MByte L3 cache UltraPath Interconnect (UPI) Up to 10.4 GigaTransfers/second (GT/s) across 2 x UPI links Chipset Intel C621 Front Side Bus Speed 2666MHz System Memory Sizes RDIMM: 64GByte, 32GByte, 16GByte or 8GByte LRDIMM: 128GByte, 64GByte or 32GByte Type Standard ECC Registered DIMMs (RDIMMs) Optional 3DS ECC Load-Reduced DIMMs (LRDIMMs) Configuration DDR4-2666MHz, 2400MHz, 2133MHz Maximum Size 1TByte using 16 x ECC Registered DIMMs (RDIMMs) 2TByte using 16 x 3DS ECC Load-Reduced DIMMs (LRDIMMs) PCI Express Gen 3.0 Slots PCIe Expansion 4 x PCI-E 3.0 x16: Slot 1 / 2 from CPU1; Slot 3 / 5 from CPU 2 2 x PCI-E 3.0 x8: Slot 4 / 6 from CPU 2 M.2 Expansion Sockets 1 x PCIe 3.0 x4 from CPU 1, M-Key 2280 and 22110 U.2 Expansion Sockets 2 x PCIe 3.0 x4 from CPU 1 (each requires 1 x data / power cable kit) System BIOS AMI User Extensible Firmware Interface (UEFI) BIOS Advanced Configuration and Power Interface (ACPI) 3.0 / 4.0 USB keyboard Feature Support Plug-n-Play (PnP) Serial Peripheral Interface (SPI) dual / quad speed System Management BIOS (SMBIOS) 2.7 or later Ethernet ports 2 x Intel RJ-45 ports supported by PCH C621 1 x port shared by Aspeed AST2500 BMC with dedicated IPMI Support 10 / 100 / 1000Mb/s Boot device Non-Volatile Memory Express (NVMe) Drive Format Solid-state drive (SSD) Transfer Rate / Connection M.2 / PCIe Gen 3 x4 Capacity, Terabytes (TB) 2, 1, 0.5 Solid-state drive (SSD) No. 24 Storage devices Serial-Attached SCSI (SAS) with 24-port RAID controller SSD Maximum Devices 24 Drive Format 2.5-inch (63.5mm) SSD 3.5-inch (88.5mm) SSD Transfer Rate / Connection 12.0Gbit/second (12Gbps) / SAS / 1.0meter mini-sas HD SFF-8643 Capacity, TB 14, 12, 10, 8, 6, 4, 2, 1, 0.5 Maximum 336TB with all drives operating RAID configuration 0, 1, 5, 6 or 10 hardware with 24-port RAID controller DVD Rewriter 8x SATA, access via front panel Baseboard Mgt Controller (BMC) Aspeed AST2500 BMC Graphics VGA Feature support IP Management Interface (IPMI) 2.0 Network 1 x GbE port shares LAN support with IPMI 2.0 Audio Controller High-Definition (HD) 7.1 with SPDIF-input digital header Universal Serial Bus (USB) Version 3.0 Ports 4 x USB 3.0 (5.0Gbits/sec) Cubix Corporation 2800 Lockheed Way Carson City, NV 89706-0719 Page 2

2 x USB 3.1 (Type-A and Type-C 10.0Gbits/sec) Cooling Fans 4 Maximum air flow each 178 cubic feet / minute (cfm) Remove / Replace Hot-plug One single-phase, auto-ranging, 100-240VAC, 45-24Amps, 50/60Hz AC Power Supply with 3 + 1 x 1,280Watt redundant modules; total output power is not to exceed 3,840Watts Operating Environment 0 to 30 Celsius (32 to 86 Fahrenheit) temperature 5% to 80% non-condensing humidity Altitude Maximum Operating 10,000ft (3,050meters) Storage 50,000ft (15,240meters) Dimensions 8.75 H x 19.00 W x 28.00 D (22.22cm H x 48.26cm W x 71.12cm D) Weight 49.00 lbs. (24.50kg) Warranty / Period Parts & labor return to manufacturer / 2 year Ext. Warranty Period Optional 3 rd year Memory Configuration DIMM Configurations for CPU1 Only # DIMMs Location Memory Scheme P1-DIMMF1 4 P1-DIMMC1 P1-DIMME1 P1-DIMMB1 P1-DIMMF1 P1-DIMMC1 Interleaved DIMMs must be identical P1-DIMME1 type and speed P1-DIMMB1 8 P1-DIMMA1 P1-DIMMA2 P1-DIMMD1 P1-DIMMD2 DIMM Configurations for CPU1 and CPU2 16 P1-DIMMF1 P1-DIMMC1 P1-DIMME1 P1-DIMMB1 P1-DIMMA1 P1-DIMMA2 P1-DIMMD1 P1-DIMMD2 P2-DIMMC1 P2-DIMMF1 P2-DIMMB1 P2-DIMME1 P2-DIMMA1 P2-DIMMD1 P2-DIMMA2 P1-DIMMD2 Interleaved DIMMs must be identical type and speed Memory Population Guidelines Use DDR4 DIMMs only. Do not mix LRDIMMs and RDIMMs. Do not mix 3DS and non-3ds LRDIMMs. If only one DIMM is populated in a channel, use the slot furthest from the CPU. Cubix Corporation 2800 Lockheed Way Carson City, NV 89706-0719 Page 3

Boot Device HostEngine provides one M.2 slot in 2280 and 22110 form factor such as the 80mm, 2TByte Samsung 960 Pro (see image at right). It also provides two U.2 slots for NVMe SSDs such as Intel SSD 750 Series. Both the M.2 and U.2 slots are PCIe Gen 3.0 x4. PCIe Gen 3 Slots When installing a HIC in HE4U, make sure you seat it in one of the PCIe Gen 3 x16 slots, which are numbered CPU1 Slot1, CPU1 Slot 2, CPU2 Slot4 and CPU2 Slot5. See the illustration at the right for the optimal configuration for BlackMagic Design DaVinci Resolve, for example. For double-wide accelerators like NVIDIA Quadro Series or AMD Firepro W Series, use slots 1, 3 and 5. If you add a single-wide display controller like AMD Firepro W2100 / W4100 or NVIDIA Quadro P4000 for connecting one or more 4K / UHD displays, use a PCIe x16 slot. For SAN controllers, which usually provide PCIe Gen 3 x8 connectivity, use CPU2 Slot 4 or Slot 6. Remove and replace PCIe devices PCIe devices can be removed and replaced from the top once you power down HostEngine, disconnect power and remove the top cover. See the image at the right for the features of each PCIe slot. Generally, install x16 devices like GPUs or Cubix HICs in x16 slots. Power down gracefully using the OS. Remove the power cord and wait for standby power to turn off. Loosen the two retention screws on the HostEngine front panel. Gently tug the HostEngine handles toward you. Remove the screws holding the top cover and set it aside. Cubix Corporation 2800 Lockheed Way Carson City, NV 89706-0719 Page 4

Disconnect auxiliary power cables from the PCIe devices such as accelerators, if needed. Remove / replace the PCIe devices and re-connect the drive power and data cables. Replace the top cover and its retaining screws. Slide HostEngine into the cabinet. Replace and tighten the retention screws. Power up HostEngine. Remove and replace a SATA drive SATA drives are removable from the front one by one after removal of the front panel. Remove the front panel, which is held in place with magnetic contacts. No tools needed. Remove / replace the drive. Replace the front panel. Remove / Replace HostEngine HostEngine can be removed and replaced from the front once you remove power. Power down gracefully using the OS or the front-panel on / off switch. Wait for the power to shut off. Disconnect power and all other cables from HostEngine. Loosen the two retention screws on the HostEngine front panel. Gently tug the HostEngine handles toward you. Extract the HostEngine while supporting its weight. Slide the replacement HostEngine into the rack mount slide mounts. Slide HostEngine into the cabinet. Replace and tighten the retention screws. Connect power and all other cables to HostEngine. Power up HostEngine. Controls, Indicators and Connections HE5URP24 front panel: 2 x USB 3 ports Press Power button to power up / down the OS Windows or Linux. Press and hold Power button 4 seconds to force power down. Press Reset button (recessed) to recycle power or reset OS Cubix Corporation 2800 Lockheed Way Carson City, NV 89706-0719 Page 5

Connections On the rear panel, HostEngine provides USB 3 ports, Gbps Ethernet ports, a VGA port and HD audio ports. The AC power receptacle is also on the rear panel. HostEngine also provides access for Cubix HICs that connect to GPU-Xpander Rackmount 8 or other Xpander enclosures using external PCIe x16 cables, if needed. With these connections, you can mount HostEngine immediately above or below GPU-Xpander Rackmount 8. You can also install PCIe cards inside HostEngine 4U. For example, install 4 x full-length, full-height, double-wide GPUs inside HostEngine 4U. On the front panel, HostEngine provides 2 x local USB ports. Troubleshooting Procedure Issue: The Cubix HIC in HostEngine is linking at x8 or x4, or at Gen 2, with Cubix Xpander, and not linking at the specified PCIE Gen 3 x16 transfer rate. Resolution: Confirm that the Cubix HIC is installed in HostEngine slot 1, 2, 3 or 5. Issue: The Cubix HICs in HostEngine are installed in PCIE Gen 3 x16 slots 1 & 3 or 2 & 5, but not all 8 x GPUs in Xpander Rackmount 8 show up in the operating system (ls pci in Linux or Windows Device Manager > Display adapters). Cubix Corporation 2800 Lockheed Way Carson City, NV 89706-0719 Page 6

Resolution: Issue: Resolution: Confirm the following setting in HostEngine system BIOS > Advanced > PCI Plug-n-Play > Above 4G Decoding > Enabled. How can I tell whether each GPU in Xpander connected to HostEngine is running at optimal bandwidth? Download Cubix GPU Manager for either Linux or Microsoft Windows (http://www.cubix.com/gpumanager/) and install it. Documentation is on-line here. Issue: Resolution: Cubix Corporation 2800 Lockheed Way Carson City, NV 89706-0719 Page 7