NI PXI Installing the NI PXI-8104 INSTALLATION GUIDE

Similar documents
This document includes instructions for installing and configuring your PXIe-8861 PXI Express controller module.

Caution Electrostatic discharge can damage your controller. To avoid such damage, handle the controller only in a proper ESD-controlled environment.

NI PXI Contents GETTING STARTED GUIDE

This document includes instructions for installing and configuring your PXIe-8821 PXI Express controller module.

NI What You Need to Get Started. Unpacking INSTALLATION GUIDE. This document explains how to set up your NI 8262 expansion module.

NI Contents. Hardware Overview INSTALLATION GUIDE. NI 8221 Features

This document includes instructions for installing and configuring your NI PXIe-8880 embedded controller.

VXI-MXI-Express Series

PXI The PXI-8220 is a two-slot PC Card (PCMCIA) carrier for the PXI/CompactPCI bus.

Getting Started with the NI 783x R

PCI/PXI Gigabit Ethernet Adapters

Electromagnetic Compatibility Guidelines

PXI The PXI-8210 is a Fast Ethernet/Ultra Wide SCSI interface for the PXI/CompactPCI bus.

NI PXIe-1062Q Power Supply Shuttle

Where to Start with NI ELVIS

NI-Industrial Communications for EtherCAT

Foundation Fieldbus Hardware and NI-FBUS Software for Windows 2000/XP

PXI and PXI Express Chassis Fan Replacement

NI-DAQ mx Base 1.x. Contents GETTING STARTED GUIDE

Using Desktop PCs as RT Targets with the LabVIEW Real-Time Module

NI PXI-1042 POWER SUPPLY SHUTTLE USER GUIDE

Where to Start with NI ELVIS

Foundation Fieldbus Hardware and NI-FBUS Software

LabVIEW Real-Time Module for Mac OS X User Manual Addendum

Installing Your PCI-GPIB, PXI-GPIB, or PMC-GPIB and NI for Solaris

NI PXI-1042 Series Power Supply Shuttle

Reconfigurable Embedded Chassis with Integrated MXI-Express (x1) MXI-Express Switch

24-Channel, ±24 V Precision PXI Source Measure Unit

R Series for PXI Express Digital RIO with Kintex-7 325T FPGA. ni.com/manuals. This document explains how to install and configure the NI PXIe-7822R.

This document provides installation, configuration, and reference information for the PXIe-8301 remote control module.

Getting Started with the NI 8234

12-Channel, ±24 V Precision PXI Source Measure Unit

R Series Reconfigurable I/O Module (AI, AO, DIO) for PXI Express, 6 AI, 18 AO, 48 DIO, 1 MS/s AIO, 512 MB DRAM, Kintex-7 160T FPGA

8x16, 2-Wire Terminal Block for the NI PXI The following conventions are used in this guide:

Using the PXI-8150B in a PXI-1025 Chassis NOTE TO USERS

This document describes the features, functions, and operation of the NI PXIe-8383mc PXImc adapter module.

Getting Started with the NI 8234

NI PXIe-4138/4139. Contents. Electromagnetic Compatibility Guidelines GETTING STARTED GUIDE. Single-Channel System SMU

Electromagnetic Compatibility Guidelines

R Series for USB Multifunction RIO with Kintex-7 70T FPGA. ni.com/manuals. Electromagnetic Compatibility Guidelines

Bracket and Mounting Dimensions

GFT9404 EIGHT CHANNEL DIGITAL DELAY GENERATOR USER MANUAL

PXIe Contents. Verifying the System Requirements GETTING STARTED GUIDE. 32-Channel Digital Pattern Instrument

NI USB-6211/6218 OEM

After completing this chapter, you will meet these objectives:

This is a learning module for a specific Learning Outcome as stipulated in the HSP that is :

INFORMATION AND COMMUNICATION TECHNOLOGY

NI sbrio Safety Guidelines GETTING STARTED GUIDE. Single-Board RIO OEM Devices. This document describes how to begin using the NI sbrio-9627.

NI TB Introduction. Conventions INSTALLATION INSTRUCTIONS Wire Terminal Block for the NI PXI-2529

NI PXIe-4080/4081/4082

Getting Started with R Series Intelligent DAQ

INSTALLATION GUIDE AND SPECIFICATIONS PXIe-4844

The NI TB-2648/2649/2650/2651 terminal blocks configure your NI PXI/PXIe-2531 (NI 2531) in one of the following topologies. 1-wire 8 64 matrix

RADEON /RADEON VE Getting Started...

To access NI 5622 documentation, navigate to Start»All Programs»National Instruments» NI-SCOPE»Documentation.

Programming for the LabVIEW Real-Time Module Using LabWindows/CVI

LabVIEW Datalogging and Supervisory Control Module

Getting Started with NI-Motion for NI 73xx Motion Controllers

Installing the A4505A PCI Module Upgrade. HP Part No. A Edition E0297 Printed in U.S.A.

INSTALLATION INSTRUCTIONS LFH160 Cable

SCB-68 User Guide. 68-Pin Shielded Desktop Connector Block

Related Information Refer to the NI Switches Help for detailed information about features and programming options for your NI switch product.

VXI-8340 SERIES INSTALLATION

GETTING STARTED NI 9501 C Series Stepper Drive Modules and NI SoftMotion Module

Getting Started with R Series Multifunction RIO

PXIe Contents GETTING STARTED GUIDE. 32-Channel Digital Pattern Instrument

Sound Card Installation for Windows 95/98

Upgrading and Servicing Guide

Chapter 3: Computer Assembly

NI PXI/PXIe/PCI Contents GETTING STARTED GUIDE. 14-Bit, 100 MS/s PXI Oscilloscope

NI CMS Contents MAINTAINING HARDWARE. NI Condition Monitoring System for NI InsightCM Enterprise

Upgrading and Servicing Guide

R Series Digital I/O Module for PCI Express, 128 DIO, 512 MB DRAM, Kintex-7 160T FPGA. This document describes how to begin using the PCIe-7821R.

Upgrading and Servicing Guide

NI PXIe Contents GETTING STARTED GUIDE. RF Preselector Module

NI CMS-9068 and NI MMS-9068

NI CMS Contents MAINTAINING HARDWARE. NI Condition Monitoring System for NI InsightCM Enterprise

Upgrading and Servicing Guide

Upgrading and Servicing Guide

Replacing the Battery HP t5730 and t5735 Thin Clients

User Guide for NUC7i3DNHNC. Intel NUC7 Business, a Mini PC with Windows 10 NUC7i3DNHNC. User Guide

Dialogic Voice Board & Driver Installation

NI PXIe-5160/5162. Contents. Electromagnetic Compatibility Guidelines GETTING STARTED GUIDE. 10-Bit Oscilloscope

Copyright 2017 HP Development Company, L.P.

You need the following to set up and use your terminal block:

Computer Assembly Step by Step DRAFT

PXI/PCI Contents GETTING STARTED GUIDE. 2 GS/s Oscilloscope

NI PXI Contents GETTING STARTED GUIDE. 8 GHz RF Amplifier

Single-Channel Precision System Source Measure Unit (SMU)

Getting Results with the NI PXI-6585R

For NI PXI and NI SCXI Switch Modules

IVN Safety Guidelines GETTING STARTED GUIDE. 100BASE-T1 Media Converter

Upgrading and Servicing Guide

IMAQ Vision Deployment Engine Note to Users

IMAQ Vision Deployment Engine Note to Users

NI CardBus-8310-to-PXI Expansion Kit

LabVIEW Real-Time Module Release and Upgrade Notes

Intel NUC Kit NUC6CAYS User Guide

NI USRP-2900/2901. Contents. Electromagnetic Compatibility Guidelines GETTING STARTED GUIDE. Universal Software Radio Peripheral

HP ProLiant SL160z G6 Server

Transcription:

INSTALLATION GUIDE NI PXI-8104 Installing the NI PXI-8104 This document contains information about installing the NI PXI-8104 controller in a PXI chassis. For complete configuration and troubleshooting information (including information about BIOS setup, adding RAM, etc.), refer to the NI PXI-8104 User Manual. The manual is in PDF format on the recovery CD included with the controller and on the National Instruments Web site, ni.com. This section contains general installation instructions for the NI PXI-8104. Consult the NI PXI-8104 User Manual for specific instructions and warnings. 1. Plug in the chassis before installing the NI PXI-8104. The power cord grounds the chassis and protects it from electrical damage while you install the module. (Make sure the power switch is turned off.) Caution To protect both yourself and the chassis from electrical hazards, leave the chassis off until you finish installing the NI PXI-8104 module. 2. Remove any panels blocking access to the system controller slot (Slot 1) in the chassis. 3. Touch the metal part of the case to discharge any static electricity that might be on your clothes or body. 4. Remove the protective plastic covers from the four bracket-retaining screws as shown in Figure 1. 5. Make sure the injector/ejector handle is in its downward position. Align the NI PXI-8104 with the card guides on the top and bottom of the system controller slot.

1 1 Protective Screw Cap (4X) Figure 1. Removing Protective Screw Caps Caution Do not raise the injector/ejector handle as you insert the NI PXI-8104. The module will not insert properly unless the handle is in its downward position so that it does not interfere with the injector rail on the chassis. 6. Hold the handle as you slowly slide the module into the chassis until the handle catches on the injector/ejector rail. 7. Raise the injector/ejector handle until the module firmly seats into the backplane receptacle connectors. The front panel of the NI PXI-8104 should be even with the front of the chassis. 8. Tighten the four bracket-retaining screws on the top and bottom of the front panel to secure the NI PXI-8104 to the chassis. 9. Check the installation. 10. Connect the keyboard and mouse to the USB connectors. If you are using a PS/2 keyboard and a PS/2 mouse, use USB-to-PS/2 adapters to connect both to the USB connectors on the front panel. You may use a Y-splitter adapter to connect both keyboard and mouse to one USB port, leaving the other USB ports free for other peripherals, such as a CD-ROM drive, or secondary hard drive. National Instruments offers a Y-splitter adapter cable, part number 778713-02, available through the online catalog at ni.com/products. NI PXI-8104 Installation Guide 2 ni.com

11. Connect the DVI monitor video cable to the DVI connector. If you are using a VGA monitor, use the DVI-to-VGA adapter included with your kit. 12. Connect peripherals to ports as required by your system configuration. 13. Power on the display. Refer to the NI PXI-8104 User Manual for details. 14. Power on the chassis. 15. Verify that the controller boots. If it does not boot, refer to the What If the NI PXI-8104 Does Not Boot? section later in this guide. Figure 2 shows an NI PXI-8104 controller installed in the system controller slot of a National Instruments PXI-1042 chassis. You can place PXI devices in any other slot. 1 2 3 1 NI PXI-1042 Chassis 2 NI PXI-8104 Controller 3 Injector/Ejector Rail Figure 2. NI PXI-8104 Controller Installed in a PXI Chassis National Instruments Corporation 3 NI PXI-8104 Installation Guide

How to Remove the Controller from the PXI Chassis The NI PXI-8104 controllers are designed for easy handling. To remove the unit from the PXI chassis: 1. Turn off power. 2. Remove the cables from the controller front panel. 3. Unscrew the bracket-retaining screws in the front panel. 4. Press the injector/ejector handle down. 5. Slide the unit out of the chassis. What If the NI PXI-8104 Does Not Boot? Several problems can cause a controller not to boot. Here are some things to look for and possible solutions. Things to Notice Things to Try Which LEDs come on? The Power OK LED should stay lit. The Drive LED should blink during boot as the disk is accessed. What appears on the display? Does it hang at some particular point (BIOS, Operating System, etc.)? If nothing appears on the screen, try a different monitor. Does your monitor work with a different PC? If it hangs, note the last screen output that you saw for reference when consulting National Instruments technical support. What has changed about the system? Did you recently move the system? Was there electrical storm activity? Did you recently add a new module, memory chip, or piece of software? Make sure the chassis is plugged into a working power source. Check any fuses or circuit breakers in the chassis or other power supply (possibly an uninterruptible power supply). Make sure the controller module is firmly seated in the chassis. Remove all other modules from the chassis. Remove any nonessential cables or devices. Try the controller in a different chassis or a similar controller in this same chassis. Clear the CMOS. (Refer to the System CMOS section of the NI PXI-8104 User Manual.) Recover the hard drive on the controller. (Refer to the Hard Drive Recovery section of the NI PXI-8104 User Manual.) NI PXI-8104 Installation Guide 4 ni.com

For more troubleshooting information, refer to the NI PXI-8104 User Manual. The manual is in PDF format on the recovery CD included with your controller and on the National Instruments Web site, ni.com. What If I Cannot See the Video? This problem usually results from having the video card output set past the limits of the monitor. You will need to boot Windows in Safe Mode. To do this, reboot the controller. As Windows begins to boot, hold down <F8>. You should now be able to reset the video driver to lower settings. Try setting the resolution to 640 480 and the refresh rate to 60 Hz. Once you reboot, you can raise these values again, using the test option in Windows. These settings are accessible through the Advanced tab of the Display item in the Control Panel. Alternately, you can try a different monitor, preferably a newer and larger one. If the system has been booted to Windows without a monitor attached, the driver may have defaulted to the video output connector being disabled. Press <Ctrl-Alt-F1> to re-enable the video display in Windows. Press <Ctrl-Alt-F4> to re-enable a DVI display. For more information, refer to KnowledgeBase 3OHCFRD8 at ni.com/support. National Instruments Corporation 5 NI PXI-8104 Installation Guide

National Instruments, NI, ni.com, and LabVIEW are trademarks of National Instruments Corporation. Refer to the Terms of Use section on ni.com/legal for more information about National Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National Instruments products, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your CD, or ni.com/patents. 2007 National Instruments Corporation. All rights reserved. 372412A-01 Dec07