REDUCED ORDER MODELING IN MULTISPECTRAL PHOTOACOUSTIC TOMOGRAPHY

Similar documents
Diffuse Optical Tomography, Inverse Problems, and Optimization. Mary Katherine Huffman. Undergraduate Research Fall 2011 Spring 2012

Advanced Image Reconstruction Methods for Photoacoustic Tomography

A fast algorithm for sparse reconstruction based on shrinkage, subspace optimization and continuation [Wen,Yin,Goldfarb,Zhang 2009]

WEIGHTED L1 AND L2 NORMS FOR IMAGE RECONSTRUCTION: FIRST CLINICAL RESULTS OF EIT LUNG VENTILATION DATA

Outline. Introduction to photoacoustic computed tomography (PACT) Imaging models and iterative image reconstruction. Success with small animal imaging

Assessment of Diffuse Optical Tomography Image Reconstruction Methods Using a Photon Transport Model

MEDICAL IMAGE ANALYSIS

Compressed Sensing Algorithm for Real-Time Doppler Ultrasound Image Reconstruction

DEEP LEARNING OF COMPRESSED SENSING OPERATORS WITH STRUCTURAL SIMILARITY (SSIM) LOSS

Multilevel Optimization for Multi-Modal X-ray Data Analysis

Forward and Adjoint Radiance Monte Carlo Models for Quantitative Photoacoustic Imaging

Implementing the probe beam deflection technique for acoustic sensing in photoacoustic and ultrasound imaging

Phase problem and the Radon transform

Méthodes d imagerie pour les écoulements et le CND

Light and tissue: 2. Two-photon, Optical Coherence Tomography, Photoacoustics

Adaptive Reconstruction Methods for Low-Dose Computed Tomography

Collaborative Sparsity and Compressive MRI

Monte Carlo Methods in Quantitative Photoacoustic Tomography

Model parametrization strategies for Newton-based acoustic full waveform

ELEG Compressive Sensing and Sparse Signal Representations

Imaging of flow in porous media - from optimal transport to prediction

Theory: modeling, localization and imaging

Computer Vision 2. SS 18 Dr. Benjamin Guthier Professur für Bildverarbeitung. Computer Vision 2 Dr. Benjamin Guthier

Optimization for Machine Learning

Full-Colour, Computational Ghost Video. Miles Padgett Kelvin Chair of Natural Philosophy

BME I5000: Biomedical Imaging

Today. Motivation. Motivation. Image gradient. Image gradient. Computational Photography

Development and validation of a short-lag spatial coherence theory for photoacoustic imaging

Refractive Index Map Reconstruction in Optical Deflectometry Using Total-Variation Regularization

Accelerating the Hessian-free Gauss-Newton Full-waveform Inversion via Preconditioned Conjugate Gradient Method

University of Lübeck, Medical Laser Center Lübeck GmbH Optical Coherence Tomography

Refraction Corrected Transmission Ultrasound Computed Tomography for Application in Breast Imaging

Two Dimensional Microwave Imaging Using a Divide and Unite Algorithm

CS 565 Computer Vision. Nazar Khan PUCIT Lectures 15 and 16: Optic Flow

Multi-Mesh CFD. Chris Roy Chip Jackson (1 st year PhD student) Aerospace and Ocean Engineering Department Virginia Tech

l ealgorithms for Image Registration

Extending the search space of time-domain adjoint-state FWI with randomized implicit time shifts

Unstructured Mesh Generation for Implicit Moving Geometries and Level Set Applications

Diffuse light tomography to detect blood vessels using Tikhonov regularization Huseyin Ozgur Kazanci* a, Steven L. Jacques b a

Bayesian estimation of optical properties of the human head via 3D structural MRI p.1

Full waveform inversion by deconvolution gradient method

Bilevel Sparse Coding

Adaptive finite element methods for the solution of inverse problems in optical tomography

Practical Least-Squares for Computer Graphics

Mathematical Methods for Photoacoustical Imaging

Introduction to Topics in Machine Learning

Efficient Iterative Semi-supervised Classification on Manifold

Edge and local feature detection - 2. Importance of edge detection in computer vision

MODEL REDUCTION FOR LARGE-SCALE SYSTEMS WITH HIGH-DIMENSIONAL PARAMETRIC INPUT SPACE

Efficient Imaging Algorithms on Many-Core Platforms

Formulas of possible interest

Image Reconstruction of the Speed of Sound and Initial Pressure Distributions in Ultrasound Computed Tomography and Photoacoustic Computed Tomography

Effect of Sensor Directionality on Photoacoustic Imaging: A Study Using the k-wave Toolbox

CoE4TN3 Medical Image Processing

Compressed Sensing for Electron Tomography

Lecture 19: Motion. Effect of window size 11/20/2007. Sources of error in correspondences. Review Problem set 3. Tuesday, Nov 20

Introduction to Optimization

Numerical methods for volume preserving image registration

Introduction to Optimization Problems and Methods

Total Variation Denoising with Overlapping Group Sparsity

Lecture 2: Seismic Inversion and Imaging

Adaptive Waveform Inversion: Theory Mike Warner*, Imperial College London, and Lluís Guasch, Sub Salt Solutions Limited

The Spherical Harmonics Discrete Ordinate Method for Atmospheric Radiative Transfer

A Novel Iterative Thresholding Algorithm for Compressed Sensing Reconstruction of Quantitative MRI Parameters from Insufficient Data

Vision par ordinateur

Fast and Efficient Stored Matrix Techniques for Optical Tomography

Guided Image Super-Resolution: A New Technique for Photogeometric Super-Resolution in Hybrid 3-D Range Imaging

Image Reconstruction in Optical Tomography : Utilizing Large Data Sets

Curvelet-based non-linear adaptive subtraction with sparseness constraints. Felix J Herrmann, Peyman P Moghaddam (EOS-UBC)

Capturing, Modeling, Rendering 3D Structures

CHAPTER 9 INPAINTING USING SPARSE REPRESENTATION AND INVERSE DCT

Partial Differential Equations

Introduction to seismic body waves Tomography

3-D Tomographic Reconstruction

Sparse Reconstruction / Compressive Sensing

Numerical Methods on the Image Processing Problems

Inter and Intra-Modal Deformable Registration:

Advanced phase retrieval: maximum likelihood technique with sparse regularization of phase and amplitude

Histograms of Sparse Codes for Object Detection

A primal-dual framework for mixtures of regularizers

G Practical Magnetic Resonance Imaging II Sackler Institute of Biomedical Sciences New York University School of Medicine. Compressed Sensing

ADVANCED RECONSTRUCTION FOR ELECTRON MICROSCOPY

Reconstruction of dielectrics from experimental data via a hybrid globally convergent/adaptive inverse algorithm

arxiv: v1 [cs.cv] 9 Jul 2018

Today s Outline - April 17, C. Segre (IIT) PHYS Spring 2018 April 17, / 22

SUPPLEMENTARY INFORMATION

dq dt I = Irradiance or Light Intensity is Flux Φ per area A (W/m 2 ) Φ =

1. Techniques for ill-posed least squares problems. We write throughout this lecture = 2. Consider the following least squares problems:

arxiv: v1 [math.na] 26 Jun 2014

CME 345: MODEL REDUCTION

Dual modality electrical impedance and ultrasound reflection tomography to improve image quality

The Immersed Interface Method

Image Restoration and Background Separation Using Sparse Representation Framework

Improving Forward Matrix Generation and Utilization for Time Domain Diffuse Optical Tomography. Damon Hyde

Fast Radial Basis Functions for Engineering Applications. Prof. Marco Evangelos Biancolini University of Rome Tor Vergata

Compressive Sensing of High-Dimensional Visual Signals. Aswin C Sankaranarayanan Rice University

Geometric adaptation and parameterization of subspacebased reduced models

Clustering: Classic Methods and Modern Views

DS Machine Learning and Data Mining I. Alina Oprea Associate Professor, CCIS Northeastern University

Markov Networks in Computer Vision

Transcription:

REDUCED ORDER MODELING IN MULTISPECTRAL PHOTOACOUSTIC TOMOGRAPHY Arvind Saibaba Sarah Vallélian Statistical and Applied Mathematical Sciences Institute & North Carolina State University May 26, 2016

OUTLINE MULTISPECTRAL PAT Prospects for Brain Imaging Forward and Inverse Problems MS-PAT INVERSION REDUCED ORDER MODELING

PHOTOACOUSTIC TOMOGRAPHY Figure: The photoacoustic tomography experiment. 3 / 20

PAT FOR BRAIN IMAGING Advantages High contrast and high resolution Noninvasive, nondestructive, inexpensive Multispectral imaging capability for better reconstructions Multiscale imaging capability Success in small animals Figure: Photoacoustic tomography on multiple scales. S. Hu and L. Wang, Front. Neuroenergetics 2010. 4 / 20

FORWARD PROBLEM Forward Problem: To compute the ultrasound pressure field at the detector array assuming that we know all properties of the medium. 1. Use the illumination pattern and optical properties to determine the absorbed optical energy, converted into pressure by the photoacoustic effect. (diffusion equation) 2. Use the internal pressure as an initial condition and propagate it with the given ultrasound speed to the detectors. (wave equation) 5 / 20

INVERSE PROBLEM Inverse Problem: To recover the interior optical properties, using the ultrasound pressure measurements at the detector array as data. One-step reconstruction via non-linear least squares is most flexible in terms of data, enforcing/requiring prior knowledge. T. Ding, K. Ren and S. V., Inverse Problems 2015. 6 / 20

TYPICAL RECONSTRUCTIONS Naive approach: 40 40 image, single wavelength, 5 mins. Data contains 1% random noise. Relative L2 error: 0.19 7 / 20

MULTISPECTRAL PAT Prospects for Brain Imaging Forward and Inverse Problems MS-PAT INVERSION REDUCED ORDER MODELING 8 / 20

MULTISPECTRAL PAT HAS ADDITIONAL UNKNOWNS Wavelength Dependence D(x, λ) = α(λ)d(x) Υ(x, λ) = γ(λ)υ(x) µ(x, λ) = K σ k (λ)µ k (x) k=1 Figure: Chromophores for biomedical optical imaging. T.G. Phan and A. Bullen, Immunol. Cell Biol. 2010. 9 / 20

FORWARD PROBLEM Diffusion Equation Wave Equation D(x, λ) φ + µ(x, λ)φ = 0, in Ω L φ = g(x, λ), on Ω L. 1 2 p c 2 (x) t 2 p = 0, in R + R d L p(0, x, λ) = Υ(x, λ)µ(x, λ)φχ Ω(x), in R d L p t (0, x, λ) = 0, in Rd L. Measurements m λ := p(t, x, λ) at certain times (0, τ), locations Σ, wavelengths L 10 / 20

SOLVING THE INVERSE PROBLEM IS COSTLY Given Υ(x, λ), D(x, λ), and {σ k (λ)} K k=1 Solution Unknown µ = {µ k (x)} K k=1 µ = arg min J(µ) := 1 m λ Λ(µ; λ) 2 + αr(µ) 2 λ L Solve via e.g. quasi-newton method, dimension is a problem: Compute Λ(µ; λ) for a given unknown µ at each iteration (solving 2 PDEs) diffusion: solve linear system of size N # pixels wave: dominant cost O(N 2 ) in 2d Compute the gradient for a given unknown µ at each iteration (solving 2 adjoint PDEs) At each iteration, must solve at all wavelengths! 11 / 20

REALISTIC PROBLEM SIZE N = 1 million: 3d image of size 1 cm 3 (approx. size of mouse brain), 100 µm resolution N λ = 10-200: different wavelengths for optical imaging K = 2 4: chromophores N r = 50-300: # ultrasound receivers N t : # time points measured Main Issue Repeated solution of large-scale systems 12 / 20

TYPICAL RECONSTRUCTIONS Naive approach: 40 40 images, 100 wavelengths, 4 hours. Data contains 1% random noise. Relative L2 error for the pair: 0.03 13 / 20

MULTISPECTRAL PAT Prospects for Brain Imaging Forward and Inverse Problems MS-PAT INVERSION REDUCED ORDER MODELING 14 / 20

WHAT IS REDUCED-ORDER MODELING (ROM)? Many ROMs use projection over a reduced-space basis: x Vx r x R N is full-scale output x r R R is reduced-order output Columns of V R N R are O.N. basis vectors, R N 15 / 20

ROM ACROSS WAVELENGTHS Goal: Avoid solving the PDEs for all wavelengths whenever possible Photon density φ(x, λ) is a smooth function of λ Diffusion system is parameterized as ( ) K α(λ)k + σ k (λ)m k φ = b(λ) k=1 Optimal ROM for wavelength-dependence: truncate SVD of φ R N N λ ; too expensive Alternative: greedy basis construction 16 / 20

REDUCTION STRATEGY Given the diffusion model as linear system Aφ = b, iteratively construct a projection matrix V R N R (R N λ ): 1. First column of V is normalized solution φ 1 to system eqns at an initial wavelength λ 1 2. Galerkin project the linear system with V and solve for reduced soln φ r at all wavelengths 3. Compute the residual norm at all wavelengths 4. Pick the wavelength λ j with largest residual; add φ j to V after ortho-normalization 5. Stop when residual at all remaining wavelengths is below tolerance 17 / 20

TEST - TWO CHROMOPHORES 0.12 0.1 Diffusion HbO2 HbR 10 0 10-2 Coefficients 0.08 0.06 0.04 Relative Residual 10-4 10-6 0.02 10-8 0 600 650 700 750 800 850 900 950 1000 Wavelength [nm] 10-10 0 2 4 6 8 10 12 14 16 18 Iteration History N λ = 200 wavelengths reduced to R = 18. Relative error b(λ) A(λ)Vφ for all wavelengths decreases as R increases. No loss of accuracy. 18 / 20

SAVINGS For the current value of µ, Operation # Diffusion Solves # Wave Solves Forward map N λ R N λ R Gradient N λ R N λ R Forward Map: Reduce # of diffusion solves Compress the initial condition of wave Reduce # of wave solves Gradient: Compress the residual m λ Λ(µ; λ) Reduce # of adjoint wave solves Compress the source of adjoint diffusion Reduce # of adjoint diffusion solves 19 / 20

SUMMARY Photoacoustic tomography is an emerging modality with applications to brain imaging Reduced-order modeling can approximate the PDE solutions in lower dimensions, cheaply We developed a ROM framework for multispectral, multispecies PAT Tradeoff: setup cost for the ROMs vs. computational savings in the inverse problem Thank you! 20 / 20