HP 5920 & 5900 Switch Series

Similar documents
H3C S7500E Switch Series

HP 10500/ G Unified Wired-WLAN Module

HP 5920 & 5900 Switch Series

About the HP 830 Series PoE+ Unified Wired-WLAN Switch and HP 10500/ G Unified Wired-WLAN Module

HP 5120 EI Switch Series

HP High-End Firewalls

About the Configuration Guides for HP Unified

HP A5120 EI Switch Series IRF. Command Reference. Abstract

HP MSR Router Series. IPX Configuration Guide(V5) Part number: Software version: CMW520-R2513 Document version: 6PW

HP 527 Dual Radio ac Unified Wired-WLAN Walljack

HP 5920 & 5900 Switch Series

HP 5820X & 5800 Switch Series IRF. Command Reference. Abstract

HP FlexFabric 5700 Switch Series

H3C S9800 Switch Series

HP 5130 EI Switch Series

HP Intelligent Management Center

HP MSR Router Series. Layer 2 LAN Switching Command Reference(V7)

HPE FlexNetwork MSR Router Series

HP 5120 SI Switch Series

H3C S5120-EI Switch Series

HP 6125XLG Blade Switch

HP 6125G & 6125G/XG Blade Switches

HP Intelligent Management Center Connection Resource Manager (Virtual Application Network Manager)

HP A3100 v2 Switch Series

v7.0 Intelligent Management Center MySQL 5.5 Installation and Configuration Guide (for Windows)

H3C S5130-EI Switch Series

Contents. Configuring LLDP 2

H3C S5130-EI Switch Series

HP MSR Router Series. About the HP MSR series Configuration Guides(V5)

Contents. Configuring LLDP 2

HP 5920 & 5900 Switch Series

HPE PSR300-12A & PSR300-12D1

H3C WX3000E Series Wireless Switches

HP Intelligent Management Center v7.1 MySQL 5.6 Installation and Configuration Guide (Windows)

HP FlexFabric 5700 Switch Series

Installation and Configuration Guide (for Linux)

H3C SecPath Series High-End Firewalls

HP 5820X & 5800 Switch Series Layer 2 - LAN Switching. Configuration Guide. Abstract

HP FlexFabric 7900 Switch Series

H3C S6300 Switch Series

H3C MSR Router Series

Contents. Configuring LLDP 2

H3C SecPath Series High-End Firewalls

HP 6125XLG Blade Switch

SQL Server Installation and Configuration Guide. Abstract

H3C S5500-HI Switch Series

H3C S7500E Switch Series

HP Load Balancing Module

H3C S6800 Switch Series

H3C S3100V2 Switch Series

HP 6125 Blade Switch Series

EVB Revisions. Paul Bottorff 13/14/2011 EVB

HP FlexFabric 5930 Switch Series

HP FlexFabric Virtual Switch 5900v Technology White Paper

Contents. Configuring LLDP 2

H3C S5830V2 & S5820V2 Switch Series

HPE Intelligent Management Center

H3C S6800 Switch Series

H3C SecPath Series High-End Firewalls

HP FlexFabric 5700 Switch Series

H3C Intelligent Management Center

v7.0 HP Intelligent Management Center MySQL 5.6 Installation and Configuration Guide (for Linux)

HP 6125 Blade Switch Series

H3C S10500 Switch Series

ProCurve Switch G ProCurve Switch G

H3C SR6600/SR6600-X Routers

H3C SecPath Series Firewalls and UTM Devices

HP Routing Switch Series

H3C S5120-HI Switch Series

H3C S12500-X & S12500X-AF Switch Series

H3C Firewall Devices. High Availability Configuration Guide (Comware V7) Hangzhou H3C Technologies Co., Ltd.

SQL Server 2008 R2. Installation and Configuration Guide

HP A-F1000-A-EI_A-F1000-S-EI VPN Firewalls

HP A3100 v2 Switch Series

H3C S5830V2 & S5820V2 Switch Series

HP VSR1000 Virtual Services Router

HPE FlexFabric 7900 Switch Series

HP 3600 v2 Switch Series

Installation and Configuration Guide

H3C S6520XE-HI Switch Series

H3C SecBlade SSL VPN Card

H3C SecPath Series Firewalls and UTM Devices

H3C S6300 Switch Series

HP V1905 Switch Series Release Notes

HP 6125 Blade Switch Series

H3C SR G Core Routers

HP 5820X & 5800 Switch Series Network Management and Monitoring. Configuration Guide. Abstract

Guidelines for using Internet Information Server with HP StorageWorks Storage Mirroring

H3C S6800 Switch Series

H3C SecPath Series High-End Firewalls

HPE FlexFabric 5940 Switch Series

SQL Server 2008 R2. Installation and Configuration Guide

H3C S5120-SI Switch Series

HP MSR Router Series. EVI Configuration Guide(V7) Part number: b Software version: CMW710-R0304 Document version: 6PW

HP Intelligent Management Center Remote Site Management User Guide

HP A5820X & A5800 Switch Series MPLS. Configuration Guide. Abstract

H3C S5130-HI Switch Series

About the HP MSR Router Series

H3C S5820X&S5800 Series Ethernet Switches

HP 3600 v2 Switch Series

Transcription:

HP 5920 & 5900 Switch Series EVB Configuration Guide Part number: 5998-3379 Software version: Release2207 Document version: 6W100-20121130

Legal and notice information Copyright 2012 Hewlett-Packard Development Company, L.P. No part of this documentation may be reproduced or transmitted in any form or by any means without prior written consent of Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. HEWLETT-PACKARD COMPANY MAKES NO WARRANTY OF ANY KIND WITH REGARD TO THIS MATERIAL, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Hewlett-Packard shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.

Contents Configuring EVB 1 Overview 1 Basic concepts 2 EVB working mechanism 2 Protocols and standards 3 EVB configuration task list 3 Enabling EVB 3 Configuring LLDP 4 Specifying a default VSI manager 4 Configuring VDP negotiation parameters 5 Configuring an S-channel 5 Creating an S-channel 5 Configuring a description for an S-channel interface 6 Configuring RR mode for an S-channel 6 Configuring MAC address learning for an S-channel 7 Configuring a VSI 7 Creating a VSI 7 Configuring VSI filters 8 Activating a VSI 8 Displaying and maintaining EVB 9 EVB configuration example 9 Support and other resources 12 Contacting HP 12 Subscription service 12 Related information 12 Documents 12 Websites 12 Conventions 13 Index 15 i

Configuring EVB Edge Virtual Bridging (EVB) allows virtual machines (VMs) on a physical server to obtain bridge relay services through a common bridge port. It enables coordinated configuration and management of bridge services for VMs. Overview Data center virtualization includes network virtualization, storage virtualization, and server virtualization. Server virtualization uses specific virtualization software such as VMware to create VMs on a single physical server. Each VM operates independently and has its own operating system, applications, and virtual hardware environments as shown in Figure 1. Figure 1 Server virtualization VMs on a physical server communicate with each other or with the outside network through a Virtual Ethernet Bridge (VEB). VEBs are implemented through software or hardware such as NICs. Both implementation methods have the following limitations: Lack of traffic monitoring capabilities such as packets statistics, traffic mirroring, and NetStream. Lack of network policy enforcement capabilities, such as QoS. Lack of management scalability, especially in unified deployment of the internal server network and the external network. EVB solves these limitations. It uses a physical switch (called EVB bridge) to switch traffic for VMs on a directly connected physical server (called EVB station). EVB implements traffic monitoring, network policy enforcement, and unified network deployment and management for VMs. 1

Basic concepts Figure 2 shows the components on the EVB station and EVB bridge. Figure 2 EVB architecture Edge Relay (ER) Transfers packets between one URP and one or more DRPs. An ER has one or more DRPs and one URP. Both URP and DRPs are called ER ports. An EVB station can have multiple ERs. S-channel A point-to-point S-VLAN established between a Port-mapping S-VLAN component in an EVB station and a Port-mapping S-VLAN component in an EVB bridge. An S-channel corresponds to the URP of an ER. On an EVB bridge, the end point of an S-channel is known as an S-channel interface. An S-channel is identified by the S-VLAN Identifier (SVID) and the S-channel Identifier (SCID), and the two values together are called an (SCID, SVID) pair. Virtual Station Interface (VSI) A port on a VM that directly connects to the DRP of an ER. A VSI is associated with a logical entity called VSI instance, which is identified by the VSI Instance Identifier (VSIID). A VSI is associated with the EVB bridge port to implement VM traffic management and policy configuration. A VSI can be considered as a subinterface of an S-channel. Reflective Relay (RR) An operation mode in which a received frame on a port that supports this function can be forwarded out of the same port. The EVB bridge uses this mode to forward traffic among VMs on an EVB station, as shown in Figure 2. EVB working mechanism An EVB station and an EVB bridge go through the following steps to implement VM traffic management: 1. Use the S-channel Discovery and Configuration Protocol (CDCP) to establish an S-channel. CDCP is used to configure S-channels between stations and bridges. When a station creates or deletes an S-channel, CDCP sends a CDCP TLV in an LLDP packet that is addressed using the Nearest non-tpmr Bridge address to the bridge. The bridge creates or deletes the S-channel. 2. Exchange EVB TLVs through LLDP to negotiate EVB capabilities for the S-channel, such as RR, ECP parameters, and VDP parameters. 3. Use the VSI Discovery and Configuration Protocol (VDP) to associate the VSIs of VMs with the bridge port. The bridge uses the VSIs to manage traffic for VMs. VDP manages the association between a VSI and a station-facing bridge port (SBP) on a bridge. VDP uses the Edge Control Protocol (ECP) to carry VDP TLVs. A VDP TLV comprises the VSIID, VSI type, and VSI version. 2

When a station creates a VM, it sends a VDP pre-associate, pre-associate with resource reservation, or associate packet to the bridge. The bridge sends the request to a VSI manager. The VSI manager notifies the bridge to create a VSI and apply policies. When a station shuts down a VM, it sends a VDP de-associate packet to the bridge. The bridge sends the request to the VSI manager. The VSI manager notifies the bridge to delete the VSI. Protocols and standards IEEE P802.1Qbg/D2.2, Draft Standard for Local and Metropolitan Area Networks MAC Bridges and Virtual Bridged Local Area Networks - Amendment XX: Edge Virtual Bridging. EVB configuration task list This document only describes EVB bridge configuration. For information about EVB station configuration, see the station manual. Tasks at a glance Enabling EVB Configuring LLDP (Optional.) Specifying a default VSI manager (Optional.) Configuring VDP negotiation parameters (Optional.) Configuring an S-channel: Creating an S-channel Configuring a description for an S-channel interface Configuring RR mode for an S-channel Configuring MAC address learning for an S-channel (Optional.) Configuring a VSI: Creating a VSI Configuring VSI filters Activating a VSI Enabling EVB Perform this task to enable EVB on a bridge port that directly connects to a station. After that, you must configure the port to operate in trunk mode. Otherwise, EVB does not work because VSI filter configuration (see "Configuring VSI filters") does not take effect. After you enable EVB on the bridge port, the device cannot forward the data received from the port at Layer 3. Do not enable both EVB and VLAN mapping, or both EVB and TRILL on a port. Do not configure the qinq enable or qinq ethernet-type service-tag command on a port enabled with EVB, and vice versa. For more information about the two commands, see Layer 2 LAN Switching Command Reference. To enable EVB: 3

2. Enter Ethernet interface view. interface interface-type interface-number 3. Enable EVB. evb enable By default, EVB is disabled on a bridge port. After EVB is enabled, a default access-type S-channel with both SCID and SVID as 1 is automatically created on this port. Configuring LLDP EVB uses LLDP to transmit CDCP TLVs, and CDCP TLVs are carried by the LLDP packet that is addressed using the Nearest non-tpmr Bridge address, so you must configure LLDP. For detailed information about the lldp global enable, lldp enable and lldp agent nearest-nontpmr admin-status commands, see Layer 2 LAN Switching Command Reference. To configure LLDP: 2. Enable LLDP globally. lldp global enable By default, LLDP is disabled globally. 3. Enter Ethernet interface view. interface interface-type interface-number 4. Enable LLDP on the interface lldp enable 5. Configure the Nearest non-tpmr Bridge agent for LLDP to operate in TxRx mode. lldp agent nearest-nontpmr admin-status txrx By default, LLDP is enabled on a port. The default mode is Disable. Specifying a default VSI manager When the bridge receives a VDP packet other than a De-Associate packet from a station, it contacts the VSI manager specified in the VDP packet to get VSI resources and policies for the station. The VSI manager ID TLV in a VDP packet carries the VSI manager's IP address. If the value for the TLV is all-zero, the VDP packet does not contain a VSI manager's IP address, so the bridge communicates with the specified default VSI manager. To specify a default VSI manager: 4

2. Specify a default VSI manager. evb default-manager { { ip ip-address ipv6 ipv6-address name name } [ port port-number ] local-server } By default, no default VSI manager is specified. Configuring VDP negotiation parameters After a station sends a VDP request other than a De-Associate request to the bridge, the bridge requests the VSI resources and policies from the VSI manager. If the bridge receives no response from the VSI manager before the VDP response-wait-delay time expires, the VDP negotiation fails. The VDP response-wait-delay time on the EVB bridge is calculated as: VDP response-wait-delay time (seconds) = 2 VDP resource-wait-delay 10 5. The value of the VDP resource wait-delay exponent is the larger of the values proposed by the station and bridge through EVB TLV. When a Pre-Associate, Pre-Associate with Resource Reservation, or Associate request from a station is successfully handled, the VSI manager notifies the bridge to create a VSI for the corresponding VM. Then the bridge starts a "VDP keepalive timer" for the VSI. If the bridge receives no keepalive from the station before the timer expires, it releases resources reserved for the association. The VDP keepalive time is calculated as: VDP keepalive time (seconds) = 1.5 [ 2 VDP keepalive + (2 ECP maximum retransmission time + 1) 2 ECP retransmission ] 10 5. The value of the VDP keepalive exponent is the larger of the values proposed by the station and bridge through EVB TLV. The ECP maximum retransmission time and ECP retransmission exponent are fixed to 3 and 16, respectively. To configure VDP negotiation parameters: 2. Enter Ethernet interface view. 3. Configure the VDP resource-wait-delay timer exponent. 4. Configure the VDP keepalive timer exponent. interface interface-type interface-number evb vdp timer resource-wait-delay exponent value evb vdp timer keepalive exponent value The default is 20. The default is 20. Configuring an S-channel Creating an S-channel An S-channel is automatically created by CDCP, and the system automatically saves the configuration in the configuration file on the bridge. You can also manually create an S-channel by performing this task. If an (SCID, SVID) pair for an S-channel is created both automatically and manually, the one automatically created takes precedence. A manually created S-channel has an access link type, and an automatically created S-channel has a trunk link type. 5

The device checks C-VLAN tagged frames (frames taking the original VLAN tags) entering an S-channel for their C-VLAN tags. If the C-VLAN does not belong to the VLANs that the S-channel and the port where the S-channel is created permit, the device cannot transmit the frames. Therefore, you must specify the C-VLAN range for the frames that an S-channel can transmit before you assign the S-channel and the port where the S-channel is created to these C-VLANs. For more information about assigning ports to a VLAN, see Layer 2 LAN Switching Configuration Guide. Follow these guidelines when you create an S-channel: Create an S-channel on a port with EVB enabled. Otherwise, an error is displayed. A default S-channel with both SCID and SVID as 1 is automatically created for the port on which EVB is enabled. When you manually create an S-channel, do not use the SCID or SVID being used by any other S-channel. Otherwise, an error is displayed. To manually create or remove S-channel, disable CDCP to automatically perform these operations. To create an S-channel: 2. Enter Ethernet interface view. 3. Create an S-channel. interface interface-type interface-number evb s-channel channel-id service-vlan svlan-id By default, only the automatically created default S-channel, with both SCID and SVID as 1, exists on a port with EVB enabled. Configuring a description for an S-channel interface 2. Enter S-channel interface view. 3. Configure a description for the S-channel interface. interface s-channel interface-number:channel-id description text The default description information is "interface name Interface." Configuring RR mode for an S-channel EVB TLVs exchanged through LLDP allow an EVB station and EVB bridge to negotiate the use of reflective relay. When the EVB station requests the use of RR mode and the EVB bridge supports RR mode, the bridge automatically enables RR mode for the S-channel and saves the configuration in the configuration file on the bridge. You can also manually enable RR mode for an S-channel by performing this task. To configure RR mode for an S-channel: 6

2. Enter S-channel interface view. interface s-channel interface-number:channel-id 3. Enable RR mode for the S-channel. evb reflective-relay By default, the RR mode is disabled for an S-channel. Configuring MAC address learning for an S-channel You can manually disable the MAC address learning function for an S-channel by performing this task. To disable MAC address learning for an S-channel: 2. Enter S-channel interface view. 3. Disable MAC address learning for the S-channel. interface s-channel interface-number:channel-id evb mac-learning forbidden By default, the MAC address learning function is enabled for an S-channel. IMPORTANT: For an S-channel with RR mode disabled, do not disable its MAC address learning function. Otherwise, the bridge might fail to forward traffic for VMs on the EVB station. After you disable the MAC address learning function for an S-channel, the bridge will discard packets with an unknown source MAC address. Configuring a VSI Creating a VSI VSIs are typically created by a VSI manager. You can also create a VSI or modify its Pre-Associate and Associate properties. A VSI is a subinterface of an S-channel interface on an EVB bridge. Removing an S-channel also removes all its VSIs. To create a VSI: 7

2. Enter S-channel interface view. 3. Create a VSI. interface s-channel interface-number:channel-id evb vsi vsi-local-id { association pre-association } By default, no VSI exists on an S-channel. Configuring VSI filters A VSI filter contains a set of VID values (VLAN information) or a set of MAC and VID values (<MAC, VLAN>). The EVB bridge uses a VSI filter to identify VSI traffic for a VM. Filters are usually assigned by a VSI manager. You can also manually create or remove VSI filters by performing this task. Follow these guidelines when you configure VSI filters for VSIs on an S-channel: Before the configuration, make sure the S-channel where you configure a VSI filter operates in trunk mode. Otherwise, the configuration fails. When you configure a VSI filter on a VSI, if the S-channel interface to which the VSI belongs or the physical port associated with the S-channel does not permit the VLAN specified in the VSI filter, the S-channel interface or the physical port automatically permits the VLAN. When you delete a VSI filter that contains information about a VLAN on a VSI, if other VSI filters on all VSIs of the S-channel interface to which the VSI belongs or on the physical port associated with the S-channel do not contain the VLAN, the S-channel interface or the physical port automatically prohibits the VLAN. When a filter configured on a VSI contains information about a VLAN, you cannot configure the filter on the same VSI again or on other VSIs of the S-channel interface to which the VSI belongs. Otherwise, the system displays an error. If the VSI filter is a set of VID values, and the MAC address learning function for the corresponding S-channel is disabled, traffic for the VSI cannot be forwarded. Activate a VSI after configuring a VSI filter, and deactivate a VSI before removing a VSI filter. To configure a VSI filter for a VSI: 2. Enter VSI view. 3. Configure a VSI filter. interface s-channel interface-number:channel-id.vsi-loc al-id evb vsi filter vlan vlan-id [ mac mac-address ] By default, no VSI filter is configured. Activating a VSI Configurations such as traffic policing for a VSI (see ACL and QoS Configuration Guide) take effect only after the VSI is activated. When a VSI is not activated, do not make any configuration except for VSI filter configuration for the VSI. To activate a VSI, you must first configure a VSI filter. To remove a VSI filter for a VSI, you must first deactivate the VSI. To activate a VSI: 8

2. Enter VSI view. interface s-channel interface-number:channel-id.vsi-lo cal-id 3. Activate the VSI. evb vsi active By default, no VSI is activated. 4. (Optional.) Configure a description for the VSI. description text The default description information is "interface name Interface." Displaying and maintaining EVB Execute display commands in any view and the reset command in user view. Task Display CDCP negotiation information. Display S-channel EVB TLV negotiation information. Command display evb cdcp [ interface interface-type interface-number ] display evb evb-tlv [ interface interface-type interface-number ] Display S-channel information. display evb s-channel [ interface interface-type interface-number ] Display EVB summary. display evb summary Display VSI information. display evb vsi [ verbose ] [ interface interface-type interface-number ] Display information about an S-channel interface or a VSI. Clear statistics for an S-channel interface or a VSI. display interface [ s-channel [ interface-number:channel-id interface-number:channel-id.vsi-local-id ] ] [ brief [ description ] ] reset counters interface [ s-channel [ interface-number:channel-id interface-number:channel-id.vsi-local-id ] ] EVB configuration example Network requirements As shown in Figure 3, the Layer 2 network of a data center comprises two switches that form an IRF fabric, four EVB bridges, and four EVB stations. They communicate within VLAN 100. An S-channel and its corresponding VSIs must be automatically created for both EVB bridge and EVB station. 9

Figure 3 Network diagram Configuration procedure This section only contains EVB configurations. For information about how to configure EVB stations, see the EVB station manual. 1. Configure EVB bridge 1: # Create VLAN 100 on EVB bridge 1. <EVB_bridge1> system-view [EVB_bridge1] vlan 100 [EVB_bridge1-vlan100] quit # Enable EVB on Ten-GigabitEthernet 1/0/1 that connects to EVB station 1, and configure Ten-GigabitEthernet 1/0/1 to operate in trunk mode. [EVB_bridge1] interface ten-gigabitethernet 1/0/1 [EVB_bridge1-Ten-GigabitEthernet1/0/1] evb enable [EVB_bridge1-Ten-GigabitEthernet1/0/1] port link-type trunk [EVB_bridge1-Ten-GigabitEthernet1/0/1] quit # Enable LLDP on EVB bridge 1 globally. Enable LLDP on Ten-GigabitEthernet 1/0/1, and configure the Nearest non-tpmr Bridge agent for LLDP to operate in TxRx mode. [EVB_bridge1] lldp global enable [EVB_bridge1] interface ten-gigabitethernet 1/0/1 [EVB_bridge1-Ten-GigabitEthernet1/0/1] lldp enable [EVB_bridge1-Ten-GigabitEthernet1/0/1] lldp agent nearest-nontpmr admin-status txrx [EVB_bridge1-Ten-GigabitEthernet1/0/1] quit Configure other EVB bridges in the same way. (Details are not shown.) 2. Verify the configuration: a. View CDCP information. Assume that each EVB station requires two S-channels. # Display CDCP information on EVB bridge 1. [EVB_bridge1] display evb cdcp ------------------------ Ten-GigabitEthernet1/0/1 ------------------ S-component capability : Local-supported/Remote-supported Supported S-Channel numbers per-port : Local-167/Remote-3 SVID range : 2-4094 10

SCID requested from remote : 1, 2, 3 SCID/SVID pair list allocated : <1, 1>, <2, 2>, <3, 3> The output shows that the EVB station has established two S-channels, 2 and 3. S-channel 1 is the default S-channel. # Display brief S-channel information on EVB bridge 1. [EVB_bridge1] display interface s-channel brief The brief information of interface(s) under bridge mode: Link: ADM - administratively down; Stby - standby Speed or Duplex: (a)/a - auto; H - half; F - full Type: A - access; T - trunk; H - hybrid Interface Link Speed Duplex Type PVID Description SCH1/0/1:1 UP auto A T 1 SCH1/0/1:2 UP auto A T 1 SCH1/0/1:3 UP auto A T 1 The output shows that the corresponding S-channel interfaces have been created. b. Verify the VSI creation. # Display EVB summary on EVB bridge 1. [EVB_bridge1] display evb summary Default manager ID: Not configured Port number: Not configured Interface S-Channel number VSI number XGE1/0/1 3 0 The output shows that no VSI exists before the EVB station sends VDP packets to the EVB bridge. [EVB_bridge1] display evb summary Default manager ID: Not configured Port number: Not configured Interface S-Channel number VSI number XGE1/0/1 3 1 The output shows that a VSI has been created after the EVB station sends VDP packets to the EVB bridge. [EVB_bridge1] display evb summary Default manager ID: Not configured Port number: Not configured Interface S-Channel number VSI number XGE1/0/1 3 0 The output shows that the corresponding VSI has been automatically deleted after the EVB station is moved. 11

Support and other resources Contacting HP For worldwide technical support information, see the HP support website: http://www.hp.com/support Before contacting HP, collect the following information: Product model names and numbers Technical support registration number (if applicable) Product serial numbers Error messages Operating system type and revision level Detailed questions Subscription service HP recommends that you register your product at the Subscriber's Choice for Business website: http://www.hp.com/go/wwalerts After registering, you will receive email notification of product enhancements, new driver versions, firmware updates, and other product resources. Related information Documents Websites To find related documents, browse to the Manuals page of the HP Business Support Center website: http://www.hp.com/support/manuals For related documentation, navigate to the Networking section, and select a networking category. For a complete list of acronyms and their definitions, see HP FlexNetwork Technology Acronyms. HP.com http://www.hp.com HP Networking http://www.hp.com/go/networking HP manuals http://www.hp.com/support/manuals HP download drivers and software http://www.hp.com/support/downloads HP software depot http://www.software.hp.com HP Education http://www.hp.com/learn 12

Conventions This section describes the conventions used in this documentation set. Command conventions Convention Boldface Italic Description Bold text represents commands and keywords that you enter literally as shown. Italic text represents arguments that you replace with actual values. [ ] Square brackets enclose syntax choices (keywords or arguments) that are optional. { x y... } [ x y... ] { x y... } * [ x y... ] * &<1-n> Braces enclose a set of required syntax choices separated by vertical bars, from which you select one. Square brackets enclose a set of optional syntax choices separated by vertical bars, from which you select one or none. Asterisk-marked braces enclose a set of required syntax choices separated by vertical bars, from which you select at least one. Asterisk-marked square brackets enclose optional syntax choices separated by vertical bars, from which you select one choice, multiple choices, or none. The argument or keyword and argument combination before the ampersand (&) sign can be entered 1 to n times. # A line that starts with a pound (#) sign is comments. GUI conventions Convention Boldface Description Window names, button names, field names, and menu items are in bold text. For example, the New User window appears; click OK. > Multi-level menus are separated by angle brackets. For example, File > Create > Folder. Symbols Convention WARNING CAUTION IMPORTANT NOTE TIP Description An alert that calls attention to important information that if not understood or followed can result in personal injury. An alert that calls attention to important information that if not understood or followed can result in data loss, data corruption, or damage to hardware or software. An alert that calls attention to essential information. An alert that contains additional or supplementary information. An alert that provides helpful information. 13

Network topology icons Represents a generic network device, such as a router, switch, or firewall. Represents a routing-capable device, such as a router or Layer 3 switch. Represents a generic switch, such as a Layer 2 or Layer 3 switch, or a router that supports Layer 2 forwarding and other Layer 2 features. Port numbering in examples The port numbers in this document are for illustration only and might be unavailable on your device. 14

Index bridging EVB default VSI manager specification, 4 EVB LLDP configuration, 4 EVB S-channel configuration, 5 EVB VDP negotiation parameter configuration, 5 EVB working mechanism, 2 configuring creating EVB, 3, 9 EVB LLDP, 4 EVB S-channel, 5 EVB VDP negotiation parameters, 5 EVB VSI, 7 EVB VSI filter, 8 EVB S-channel, 5 default VSI manager (EVB), 4 edge relay (EVB), 2 Edge Virtual Bridging. Use EVB enabling EVB, 3 Ethernet EVB EVB configuration, 3, 9 basic concepts, 2 configuration, 3, 9 default VSI manager specification, 4 displaying, 9 edge relay, 2 enabling, 3 how it works, 2 LLDP configuration, 4 maintaining, 9 filter LLDP network protocols and standards, 3 reflective relay, 2 S-channel, 2 S-channel configuration, 5 S-channel creation, 5 VDP negotiation parameter configuration, 5 virtual station interface, 2 VSI configuration, 7 VSI filter configuration, 8 EVB VSI filter configuration, 8 configuring for EVB, 4 EVB default VSI manager specification, 4 EVB enable, 3 EVB LLDP configuration, 4 EVB S-channel configuration, 5 EVB S-channel creation, 5 EVB VDP negotiation parameter configuration, 5 EVB VSI configuration, 7 EVB VSI filter configuration, 8 EVB working mechanism, 2 network management port EVB configuration, 3, 9 EVB configuration, 3, 9 EVB enable, 3 EVB LLDP configuration, 4 EVB S-channel configuration, 5 15

EVB VDP negotiation parameter configuration, 5 procedure configuring EVB, 3, 9 configuring EVB LLDP, 4 configuring EVB S-channel, 5 configuring EVB VDP negotiation parameters, 5 configuring EVB VSI, 7 configuring EVB VSI filter, 8 creating EVB S-channel, 5 displaying EVB, 9 enabling EVB, 3 maintaining EVB, 9 protocols and standards EVB, 3 reflective relay routing EVB RR, 2 EVB configuration, 3, 9 EVB default VSI manager specification, 4 EVB LLDP configuration, 4 EVB S-channel configuration, 5 EVB VDP negotiation parameter configuration, 5 EVB working mechanism, 2 S-channel configuration, 5 creation, 5 EVB, 2 EVB VSI configuration, 7 EVB VSI filter configuration, 8 S-channel interface EVB VSI configuration, 7 EVB VSI filter configuration, 8 traffic management EVB VSI filter configuration, 8 VDP negotiation parameters, 5 Virtual Ethernet Bridge. Use VEB virtual station interface (EVB), 2 virtualization EVB configuration, 3, 9 VM EVB configuration, 3, 9 VSI EVB configuration, 7 filter configuration, 8 16