User Manual Back-UPS BE650MC

Similar documents
Installation and Operation Manual Back-UPS BR900G-RS

Installation and Operation Back-UPS Pro 900

Installation and Operation Back-UPS Pro BR700G-TW

Installation and Operation Back-UPS Pro 900

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN

Back-UPS RS 550 Installation & Operation

User Manual Back-UPS Pro BN 1100/1350/1375/1400/1500 M2 BN 1100/1350/1500 M2-CA

Back-UPS RS APC Back-UPS RS 800VA 120V Black

Broadband Automatic Disconnect Switch. User Manual

Powerware 3105 UPS User s manual

Powerware 3105 UPS User s manual

Installation and Operation

IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

Model: VA/230W UPS Backup System

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA. GE Critical Power

OFFICE UPS MULTI-DEVICE PROTECTION UPS 500S/600S/750S

Operation Manual. Smart-UPS. Uninterruptible Power Supply. 750/1000/1500/2200 VA Rack-Mount 2U 100/120/230 Vac

EATON 5S 850/1200/1600

powerware 5105 User s Guide VA

Operation Manual. Smart-UPS X Uninterruptible Power Supply

APC Matrix-UPS 3kVA 208V/240V In 120/208/240V Out

Smart-UPS RT APC SMART-UPS RT 2000VA 120V

VS Series 120V 600VA 300W Line-Interactive Desktop UPS, Tower, 6 Outlets

Smart-UPS APC Smart-UPS 1500VA USB & Serial 120V

Owner s Manual. Models: ECO650LCD, ECO850LCD. Not suitable for mobile applications

Smart-UPS APC Smart-UPS 750VA USB & Serial RM 1U 120V

Smart-UPS APC Smart-UPS 2200VA USB & Serial 120V

POS Series 120V 50/60Hz 500VA 300W Standby UPS, Tower, USB port, 6 Outlets, TEL/DSL Protection

User s Manual Legend SB425 K

U P S USER S MANUAL IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. Uninterruptible Power System. Line Interactive (Network) UPS

Smart-UPS APC Smart-UPS 2200VA RM 3U 120V/230V In 120V Out

ECO Series 120V 850VA 425W Energy-Saving Standby UPS with USB, LCD Display and 12 Outlets

APC Back-UPS - Floor Style

Smart-UPS APC Smart-UPS 750VA USB & Serial 120V

TAA-Compliant POS Series 120V 500VA 300W Standby UPS, Tower, USB port, 6 Outlets, TEL/DSL Protection

ECO Series 120V 850VA 425W Energy-Saving Standby UPS with USB port, LCD Display and 12 Outlets

QuickSpecs HP T750 UPS. Overview

User Manual. C Type Power Filter. Model C3 and C3BLK

Operation Manual. Back-UPS Pro. Uninterruptible Power Supply. BG Vac

User Manual Smart-UPS On-Line SRC1KI, SRC2KI, SRC1KI-AR, SRC2KI-AR

TAA-Compliant ECO Series 120V 550VA 300W Energy-Saving Standby UPS with USB monitoring and 8 Outlets

Protect It! 10-Outlet Surge Protector, 8 ft. Cord with Right-Angle Plug, 2395 Joules, Tel/DSL Protection, Black Housing

Liebert PSA5. Installer/User Guide

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

SmartPro LCD 120V 1500VA 900W Line- Interactive UPS, AVR, 2U Rack/Tower, LCD, USB, DB9 Serial, 8 Outlets

Internet Office UPS System - All-in-one SOHO Solution

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE

Smart-UPS XL APC Smart-UPS XL 2200VA RM 3U 120V

User s Manual Legend SB500R UPS K

SmartPro 120V 1.5kVA 1.35kW Line-Interactive Sine Wave UPS, 2U, Extended Run, Network Card Options, LCD, USB, DB9

User Manual. C Type Wall Mount Power Filter C2, C2-CN

Thunderbolt 3 Multiport Dock USER MANUAL UH7230

Symmetra LX APC Symmetra LX 8kVA Scalable to 8kVA N+1 Rack-mount, 208/240V Input, 208/240V and 120V Output

Model #: ECO350UPS. 350VA Eco Energy-Saving UPS System. Highlights. Description. Features

Symmetra LX APC Symmetra LX 8kVA Scalable to 16kVA N+1, Tower 208/240V Input, 208/240V and 120V Output

ECO Series 120V 900VA 480W Energy-Saving Standby UPS with USB, Muted Alarm and 12 Outlets

Internet Office 120V 600VA 300W Standby UPS, Ultra-Compact Desktop, USB

Internet Office 120V 750VA 450W Standby UPS, Ultra-Compact Desktop, USB

Line Interactive 1000VA/1400VA/2000VA Uninterruptible Power System

SmartPro LCD 120V 50/60Hz 1500VA 900W Line- Interactive UPS, AVR, Tower, LCD, USB, 10 Outlets

TV WIRELESS HEADPHONES

Metered Rack PDU Rack PDU, Metered, Zero U, 20A, 120V, (24) NEMA 5-20R

Protect It! 8-Outlet A/V Surge Protector, 10-ft. Cord, 3240 Joules, Tel/Modem/Coax Protection

Reliable backup power and surge protection for your critical electronics. Uninterruptible Power Supply Back-UPS Pro Compact Towers

Installation Guide Smart-UPS On-Line SRT5K/6K Tower/Rack-Mount 3U/4U

SmartPro LCD 120V 1300VA 720W Line- Interactive UPS, AVR, Tower, LCD, USB, 8 Outlets

SmartOnline SVTX Series 3-Phase 380/400/415V 30kVA 27kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

OFFICE UPS MULTI-DEVICE PROTECTION UPS 500S/600S/750S USER S MANUAL

Protect It! 10-Outlet Surge Protector, 8 ft. Cord with Right-Angle Plug, 2395 Joules, Tel/DSL Protection, Black Housing

Internet Office 120V 550VA 300W Standby UPS, Ultra-Compact Desktop, USB

Symmetra LX APC Symmetra LX 8kVA Scalable to 16kVA N+1 Rack-mount, 208/240V Input, 208/240V and 120V Output

Liebert PST5. Installer/User Guide

SmartPro LCD 120V 1500VA 900W Line-Interactive UPS, AVR, Tower, LCD, USB, 10 Outlets

TAA-Compliant SmartPro LCD 120V 1000VA 500W Line-Interactive UPS, AVR, Tower, USB, TEL/DSL/Coax Protection, 8 Outlets

550VA Audio/Video Backup Power Block - Exclusive UPS Protection for Structured Wiring Enclosure

ECO Series 120V 350VA 180W Energy-Saving Standby UPS with USB and 6 Outlets

Line-Interactive UPS with USB and 8 Outlets - 120V, 1000VA, 600W, 50/60 Hz, AVR, ECO Series, ENERGY STAR

SmartPro 120V 1.5kVA 1.44kW Line-Interactive Sine Wave UPS, 2U, Extended Run, Network Card Options, USB, 8 Outlets

Safety and Maintenance You can use your Tablet PC under a wide range of environmental conditions. However, to ensure long use and continued high

SmartPro LCD 120V 1200VA 700W Line- Interactive UPS, AVR, 2U Rack/Tower, LCD, USB, DB9 Serial, 8 Outlets

SmartPro 230V 1kVA 500W Line-Interactive UPS, Tower, LCD, USB, 6 Outlets

USB-C Multiport Dock with Power Charging USER MANUAL UH3230

SmartOnline. Rack/Tower Mount On-Line UPS Systems. Not suitable for mobile applications.

SmartPro UPS System Intelligent line interactive medical-grade battery backup and network power management

850VA 480W Line-Interactive UPS with 6 C13 Outlets - AVR, 230V, C14 Inlet, LCD, USB, Tower

TAA SmartPro 120V 1.5kVA 1.35kW Line- Interactive Sine Wave UPS, 2U, Extended Run, Network Card Options, LCD, USB, DB9

SmartOnline 120V 3kVA 2.7kW On-Line Double- Conversion UPS, 2U Rack/Tower, Extended Run, Network Card Option, ENERGY STAR

SmartPro 120V 750VA 500W Line-Interactive Sine Wave UPS, Tower, SNMPWEBCARD Option, USB, DB9 Serial

Model #: INTERNET750U

Table of Contents. Automatic Transfer Switch. User Manual ATS-16A/20A/30A/32A

Protect It! 7-Outlet Surge Protector, 6 ft. Cord, 1080 Joules, Diagnostic LED, Light Gray Housing

SmartPro 120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMPWEBCARD Option, USB, DB9 Serial

R/T2000 G2 HP R/T 2200 UPS INTL HP R/T 2200 UPS JPN/TWN

SmartOnline 120V 3kVA 2.7kW Double- Conversion UPS, 3U Rack/Tower, Extended Run, WEBCARDLX Network Interface, LCD, USB, DB9

SmartPro LCD 120V 1000VA 500W Line-Interactive Desktop UPS, AVR, Tower, USB, TEL/DSL/Coax, 8 Outlets, ENERGY STAR

Isobar 2-Outlet Surge Protector, Direct Plug-In, 1410 Joules, Diagnostic LEDs, Tel/Fax/Modem, Black Metal Housing

SmartOnline SVX Series 90kVA 400/230V 50/60Hz Modular Scalable 3-Phase On-Line Double- Conversion Medium-Frame UPS System, 5 Battery Modules

SmartPro 120V 1kVA 750W Medical-Grade Line- Interactive Tower UPS with 4 Outlets, Full Isolation, USB, Lithium Battery

SmartOnline 230V 2kVA 1800W On-Line Double- Conversion UPS, Tower, Extended Run, Network Card Options, LCD, USB, DB9

SmartOnline 208/230V 1kVA 900W Double- Conversion UPS, 2U, Extended Run, SNMP Card Option, LCD, USB, DB9, ENERGY STAR

Transcription:

User Manual Back-UPS BE650MC Inventory Back-UPS ES 650 bu075b This unit is intended for indoor use only. Do not operate this unit in direct sunlight, in contact with fluids, or where there is excessive dust or humidity. Connect the Back-UPS power cord directly into a wall outlet. Do not use a surge protector or an extension cord. Specifications Input Output Protection and Filter Battery Physical EMC compliance Voltage 120 Vrms nominal Frequency 60 Hz ± 3 Brownout transfer 92 Vrms typical Over-voltage transfer 139 Vrms typical Output Power 650 VA, 390 W Total Amperage (8 outlets) 12 A (including UPS output) Voltage - On Battery 115 Vrms ± 8% (step-approximated sine wave) Frequency - On Battery 60 Hz ± 1 Hz Transfer time 6 ms typical, 10 ms maximum Utility power surge protection Always on, 340 Joules Modem/Phone/FAX surge protection Single line, 2-wire EMI/RFI filter Always on Utility input Resettable circuit breaker Type Sealed, maintenance-free lead-acid Average life 3-5 years depending on the number of discharge cycles and environmental temperature Net weight 6.0 kg (13.2 lbs) Dimensions H x W x D 28 cm x 18 cm x 9 cm (11 in x 7 in x 3 in) Operating temperature 0º C to 40º C (32º F to 104º F) Storage temperature 5º C to 45º C (5º F to 113º F) Operating relative humidity 0 to 95% non-condensing Operating elevation 0 to 3,000 m (0 to 10,000 ft) Notice: This device complies with part 68 and part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. "Locate the label on the bottom of this device that contains, among other information, the FCC registration number and ringer equivalence number (REN) for this device. If requested, this information must be provided to the telephone company." 990-3929 06/2010

Installation Battery Backup and Surge Protection Outlets Master Battery Backup+ Surge Protection Master Enable Power On Back-UPS ES 650 Surge Protection Controlled by Master bu092b Surge Protection Outlets Building Wirint Fault Circuit Breaker Push to Reset Modem/ Phone/FAX Wall Outlet Data Port CAUTION-Refer to bottom of unit for safety markings. bu108b Connect the battery Press the battery compartment cover release tab located on the rear side of the unit. Slide the battery cover off. Remove the battery from the Insert the battery into the compartment. Connect the battery compartment. Replace the battery cable securely to the battery terminal. cover. Ensure the release tab locks into place. bu064b bu065b bu066b Connect equipment to battery backup outlets Battery backup outlets provide protection to connected equipment when the Back-UPS is turned on and connected to utility power. Battery backup outlets receive power from the Back-UPS for a limited period of time when a power outage or brownout condition occurs. Battery backup outlets provide protection from power surges and spikes. Connect a computer, a monitor, and other peripheral devices to the battery backup outlets. 2 User Manual BE650MC

Install PowerChute software Install the PowerChute software CD in the computer and follow the prompts to install the software. Connect modem/phone/fax Use a standard telephone cable to connect the Back-UPS Wall Outlet port to a telephone wall jack. Use a standard telephone cable to connect the Back-UPS Modem/Phone/FAX port to a modem or FAX machine. Connect equipment to surge protection outlets Surge protection outlets provide protection to connected equipment when the Back-UPS is connected to utility power and is turned on or off. Surge protection outlets provide protection from power surges and spikes. Connect a printer, FAX machine, scanner, or other peripheral devices to the surge protection outlets. Connect equipment to power saving outlets The Master and Controlled by Master outlets provide energy conservation capability. Connect a computer or an A/V receiver to the Master outlet. Connect peripheral devices, such as a printer, speakers, or a scanner to the Controlled by Master outlets. When the device connected to the Master outlet goes into Sleep mode, Standby mode or turns off, the devices connected to the Controlled by Master outlets will automatically shut down. Note: The Back-UPS ships with the power saving feature DISABLED. To use this feature, the outlets must be enabled. Enable the power saving feature The Master Enable LED illuminates green when the power saving feature is enabled. Press and hold Master Enable button for two seconds. The unit will beep to indicate the feature is enabled. The Master Enable LED will illuminate green. Disable the power saving feature Press and hold Master Enable button for two seconds. The unit will beep to indicate the feature is disabled. The Master Enable LED not be illuminated. Setting the threshold The amount of power used by a device in Sleep or Standby mode varies. It may be necessary to adjust the threshold at which the Master outlet signals the Controlled outlets to shut down. 1.Ensure a master device is connected to the Master outlet. Put that device into Sleep mode, Standby mode, or turn the device off. Press and hold the Master Enabled button for six seconds. After two seconds the unit will beep. Continue holding the button down until the unit beeps three times. Release the Master Enabled button. The Back-UPS will now recognize the new threshold level of the master device and save it as the new threshold setting.connect the battery The Back-UPS is shipped with one battery cable disconnected. Prior to connecting any equipment to the unit, connect the battery cable to the unused battery terminal. User Manual BE650MC 3

Operation Turn On the Back-UPS Press the Power On button located on the top of the Back-UPS. The Power On LED will illuminate and a single short beep will be audible, indicating that the Back-UPS is providing protection for connected equipment. To turn the Back-UPS off, press the Power On button. The Back-UPS battery charges during the first 16 hours while connected to utility power. The Back-UPS battery will charge while the Back-UPS is connected to utility power and is turned on or off. Status Indicators Status LED Indicator Audible Indicator On - Back-UPS is supplying conditioned utility power to connected equipment. On Battery-Back-UPS is supplying battery power to battery backup outlets. Low Battery Warning- Back-UPS is supplying battery power to the battery backup outlets and the battery is near a total discharge state. - The battery is disconnected. The battery needs to be charged, or replaced. Overload Shutdown- While operating on battery power an overload condition has occurred in one or more of the battery backup outlets. Sleep Mode- While on battery power the battery is completely discharged. The Back-UPS will begin operation once utility power is restored. Building Wiring Fault-LED illuminates when there is no ground circuit, an overloaded neutral, or there is a reversed polarity in the building wiring. Discontinue use and have a qualified electrician check the wiring in the building. Master Enable LEDilluminates when the power saving feature is enabled. LED illuminates green. LED illuminates green. The LED is not illuminated during the beeps. LED flashes green. LED flashes alternately green and red. LED flashes alternately green and red. Back-UPS beeps four times every 30 seconds. Back-UPS emits rapid beeping, (every 1/2 second). Constant tone Constant tone LED or Audible Indicator Off Beeping stops when power transfers back to utility power or the Back-UPS is turned off. Beeping stops when power transfers back to utility power or the Back-UPS is turned off. Back-UPS is turned off. Back-UPS is turned off. Constant tone Back-UPS is turned off. Building Wiring Fault LED illuminates red. Master Enable LEDilluminates green when the power-saving feature is enabled. Back-UPS beeps four times every 30 seconds. Utility power is restored If utility power is not restored within 32 seconds The Back-UPS is turned off Back-UPS is turned off. Building wiring fault is corrected. 4 User Manual BE650MC

Voltage Sensitivity Adjustment (optional) The Back-UPS detects and reacts to line voltage distortions by transferring to battery backup power to protect connected equipment. In situations where either the Back-UPS or the connected equipment is too sensitive for the input voltage level it is necessary to adjust the transfer voltage. 1. Connect the Back-UPS to a wall outlet. The Back-UPS will be in Standby mode, no indicators will be illuminated. 2. Press and hold the Power On button for 10 seconds. The LED will illuminate alternately green-amber-red, to indicate that the Back-UPS is in Program mode. 3. The Back-UPS will indicate the current sensitivity level. Refer to the table below for an explanation of the transfer voltage sensitivity levels. 4. To select LOW sensitivity, press and hold the Power On button until the LED flashes green. 5. To select MEDIUM sensitivity, press and hold the Power On button until the LED flashes red. 6. To select HIGH sensitivity, press and hold the Power On button until the LED flashes amber. 7. To exit Program mode wait five seconds and all LED indicators will extinquish. Program mode is no longer active. LED color flashes Sensitivity Setting Input Voltage Range Use Indications Green LOW 88 V to 142 V Input voltage is extremely low or extremely high. Not recommended for computers. Red MEDIUM (factory default) 92 V to 139 V Use when the Back-UPS frequently switches to battery operation. Amber HIGH 96 V to 136 V Use when connected equipment is sensitive to voltage fluctuations. User Manual BE650MC 5

Troubleshooting Problem and Possible Cause The Back-UPS will not turn on The Back-UPS has not been turned on. The Back-UPS is not connected to utility power, there is no utility power available at the wall outlet, or the utility power is experiencing a brownout or over voltage condition. The Surge Protection outlets have no power The surge protection outlets are experiencing an overload condition. The Back-UPS is not connected to utility power, there is no utility power available at the wall outlet, or the utility power is experiencing a brownout or surge condition. Connected equipment loses power Press the Power On button. Solution Ensure the power cord is securely connected to the wall outlet, and that there is utility power available at the wall outlet.where applicable, check that the wall outlet is switched on. Remove all nonessential equipment connected to the surge protection outlets. Push the Circuit Breaker Reset button located on the side of the unit. Ensure the power cord is securely connected to the wall outlet, and that there is utility power available at the wall outlet, (check that any switch for the wall outlet is on). Equipment is connected to the surge protection outlets. Make sure the equipment that must remain functioning during a power failure, is plugged into the battery backup outlets. A Back-UPS overload condition has occurred. Remove all nonessential equipment connected to the outlets. One at a time reconnect equipment to the Back-UPS. The Back-UPS battery is completely discharged. Connect the Back-UPS to utility power and allow the battery to recharge for 16 hours. PowerChute software has performed a shutdown due to a power The Back-UPS is operating normally. failure. The Back-UPS may require service. Contact APC Technical Support for more in depth troubleshooting. The Back-UPS is on and the Replace Battery LED flashes and the unit emits a constant tone The battery is disconnected. Refer to Specifications on page 1. The Power On LED is illuminated and the Back-UPS beeps four times every 30 seconds The Back-UPS is operating on battery power. The Building Wiring Fault LED illuminates A building wiring fault exists. The Back-UPS has an inadequate battery runtime The battery is not fully charged. The battery life cycle is near completion. The Back-UPS is sending no Modem/Phone/FAX signal The data line from the ISP or wall outlet is connected to the wrong port on the Back-UPS. The connection from the Back-UPS to the internet is lost during a power outage The modem has lost power. The Back-UPS is operating normally on battery power. At this point the user should save all open files, and shutdown the computer. When utility power is restored the battery will recharge. Do not operate the Back-UPS, this will void the warranty. Call a qualified electrician to correct the building wiring fault. Leave the Back-UPS connected to utility power for 16 hours while the battery charges to full capacity. As the battery ages the runtime capability decreases. To order a replacement battery contact APC at www.apc.com. The data ports on the Back-UPS are labelled. Check to be sure they are connected properly. Connect the modem cable into one of the surge protection outlets. 6 User Manual BE650MC

Battery replacement Deliver the used battery to a recycling facility. Replace the used battery with an APC approved battery. Replacement batteries can be ordered through the APC Web site, www.apc.com. Warranty The standard warranty is 3 years from the date of purchase. APC standard procedure is to replace the original unit with a factory reconditioned unit. Customers who must have the original unit back due to assigned asset tags and set depreciation schedules must declare such a need at first contact with APC Technical Support. APC will ship the replacement unit once the defective unit is received by the repair department or cross-ship upon the provision of a valid credit card number. The customer pays for shipping to APC, and APC pays ground freight transportation costs back to the customer. Service If the unit requires service, do not return it to the dealer. Follow these steps: 1. Review the Troubleshooting section of the manual to eliminate common problems. 2. If the problem persists, contact APC Customer Support through the APC Web site, www.apc.com. a. Note the model number and serial number and the date of purchase. The model and serial numbers are located on the rear panel of the unit and are available through the LCD display on select models. b. Call APC Customer Support and a technician will attempt to solve the problem over the phone. If this is not possible, the technician will issue a Returned Material Authorization Number (RMA#). c. If the unit is under warranty, the repairs are free. d. Service procedures and returns may vary internationally. Refer to the APC Web site for country specific instructions. 3. Pack the unit in its original packaging. If this is not available, refer to www.apc.com to obtain a new set. a. Pack the unit properly to avoid damage in transit. Never use foam beads for packaging. Damage sustained in transit is not covered under warranty. b. For the UPS, always DISCONNECT THE BATTERY before shipping in compliance with U.S. Department of Transportation (DOT) and IATA regulations. The battery may remain in the unit. c. Internal batteries may remain connected in the XLBP during shipment, (if applicable, not all units have XLBPs). 4. Write the RMA# provided by Customer Support on the outside of the package. Return the unit by insured, pre-paid carrier to the address provided by Customer Support. Contact APC Worldwide Support APC Web site, www.apc.com Telephone Support: (888) 272 3858 Customer support and warranty information is available at the APC Web site, www.apc.com. 2010 APC by Schneider Electric. APC, the APC logo, Back-UPS and PowerChute are owned by Schneider Electric Industries S.A.S., American Power Conversion Corporation, or their affiliated companies. All other trademarks are property of their respective owners. User Manual BE650MC 7