XPSMC16ZCPACK safety controller XPS-MC - 24 V DC - 16 input - 32 LEDs signalling

Similar documents
XPSMC16ZPPACK safety controller XPS-MC - 24 V DC - 16 input - 32 LEDs signalling

XPSMC16ZP safety controller XPS-MC - 24 V DC - 16 input - 32 LEDs signalling

XPSMC16Z safety controller XPS-MC - 24 V DC - 16 input - 30 LEDs signalling

XPSMC32Z safety controller XPS-MC - 24 V DC - 32 input - 46 LEDs signalling

XPSMC16Z safety controller XPS-MC - 24 V DC - 16 input - 30 LEDs signalling

XPSMP11123P module XPS-MP - 2 independent functions - 24 V DC

Safety automation system solutions 0 Preventa configurable safety controllers

TM3SAC5RG SAFETY MODULE FOR PLC TM2xx, 1 FUNCTION, CAT3, SPRING TERMINALS

TSXPAY262 Preventa safety module - 24 V DC - standard format - < 5 W

K1D004ACH cam switch - 4-pole A - for Ø 22 mm

RM4JA01F current measurement relay RM4-J - range ma V AC

Product Substitution Details - Safety Modules

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

TM3SAF. Main. Device short name

TM3SAK. Main. Device short name

RM4JA32MW current measurement relay RM4-J - range A V AC DC

K1B004TLH cam switch - 1 pole A - screw mounting

XPSMCMDI Input expansion module with screw term

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

K1D012ULH cam changeover switch - 2-pole A - screw mounting

SD328AU68S2 motion control stepper motor drive - SD328 - <= 6.8 A

XB4BK123B5. Product data sheet Characteristics. Complete illuminated selector switch. position stay put 1NO+1NC 24V. Main.

RM4UA33M voltage measurement relay RM4-U - range V V AC

XB7NG33 key selector switch - Ø 22 - keylock - 3 positions - 2 NO - Ronis 455 center

XB5AS8445 red Ø40 Emergency stop, switching off Ø22 trigger latching turn release 1NO+1NC

K1K015NZ4 cam stepping switch - 2-pole A - screw mounting

K1C024B body for BCD encoded output switch - 1 pole A - for Ø 22 mm

XB7NS8442 Emergency stop Ø 22 - red - mushroom head Ø 40 mm - turn to release - 1 NC

XB7NA4234 PB - Spring Rtn, red - 1NC -White "STOP"

K1F037MCH cam voltmeter switch - 3L and 3L-N A - for Ø 22 mm

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

Safety automation solutions

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

RM4TR31 three-phase network control relay RM4-T - range V

XPSMCMMX inputs 2 output pairs expansion module with screw term

XPSMCMDO Digital output pairs expansion modules with screw term

ZB4BW061 light block with body/fixing collar for BA9s bulb 250V 1NO

ZB5FG09 flush mounted selector switch head key pos stay put

XB4BT845 Red Ø40 Emergency stop, switching off Ø22 latching push pull 1NC+1NO

SR2B201FU compact smart relay Zelio Logic - 20 I O V AC - clock - display

XCKJ10541H29 limit switch XCKJ - th.plastic roller lever var. length - 1NC+1NO - snap - M20

RE8YG31BUTQ industrial timing relay s - type Qc - 24 V AC/DC, V AC - 1C/O

Safety automation system solutions 0

XCKM102 limit switch XCKM - steel roller plunger - 1NC +1NO - snap action - Pg11

XCKN2110P20 limit switch XCKN - metal end plunger - 1NC +1NO - snap - M20

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term

XCSRC10M12 Safety RFID contactless switch - Single model - Unique pairing

RE7YA12BU time delay relay for star-delta starter s - 24 V AC DC - 2OC

XB4BW33B5 green flush complete illum pushbutton Ø22 spring return 1NO+1NC 24V

RM4JA31M current measurement relay RM4-J - range ma V AC

RXM4AB3BD Miniature Plug-in relay - Zelio RXM 4 C/O 24 V DC 6 A with LED

XCKP2110G11 limit switch XCKP - metal end plunger - 1NC+1NO - snap - Pg11

XCKS141H29 limit switch XCKS - th.plastic roller lever var. length - 1NC+1NO - snap - M20

RE8TA31BU industrial timing relay s - type A - 24 V AC/DC, V AC - 1 C/O

K1F006ALH cam switch - 6-pole A - screw mounting

RE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

ABE7R16S210 sub-base - soldered electromechanical relays ABE7-16 channels - relay 10 mm

XCKS131 limit switch XCKS - thermoplastic roller lever - 1NC+1NO - snap action - Pg13

SR2B121FU. Price* : USD with ladder programming. 80 maat 100 V (without extension)

RM4LA32M liquid level control relay RM4-L V AC

SR2A201BD compact smart relay Zelio Logic - 20 I O - 24 V DC - no clock - display

RM4TA32 three-phase network control relay RM4-T - range V

RE7YA12BU. Main. Contacts type and composition Component name Time delay type. 24 V AC/DC at 50/60 Hz V AC/DCat 50/60 Hz

OTB1C0DM9LP. Main , length of segment <= 185 m , length of segment <= 160 m. 3.4 kohm for I8...I kohm I0...I1 5.7 kohm I6...

RXM4AB1MD Miniature Plug-in relay - Zelio RXM 4 C/O 220 V DC 6 A

XCKJ10511 limit switch XCKJ - thermoplastic roller lever - 1NC+1NO - snap action - Pg13

K1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm

Safety automation system solutions 0

SR3B261FU modular smart relay Zelio Logic - 26 I O V AC - clock - display

RSB1A160JD interface plug-in relay - Zelio RSB - 1 C/O - 12 V DC - 16 A

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

K1D011B body for BCD encoded output switch - 1 pole A - for Ø 22 mm

XB4BS542 red Ø40 Emergency switching off pushbutton Ø22 latching turn release 1NC

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

XCKD3918P16EX limit switch XCKD - roller lever - 2NC + NO - ATEX/IECEx

RM35TF V AC

RE7RM11BU off-delay timing relay with control contact s - 24 V AC DC - 1OC

ABL1REM24025 regulated SMPS - single phase V input - 24 V output - 60 W

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

XB4BT842 Red Ø40 Emergency stop, switching off Ø22 latching push pull 1NC

RPM42P7 power plug-in relay - Zelio RPM - 4 C/O V AC - 15 A - with LED

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

RXM4AB1BD miniature plug-in relay - Zelio RXM - 4 C/O - 24 V DC - 6 A

RPM13F7 power plug-in relay - Zelio RPM - 1 C/O V AC - 15 A - with LED

TM3AI4 module TM3-4 analog inputs

XCMD2110L1 limit switch XCMD - metal end plunger - 1NC +1NO - snap - 1 m

RM35LM33MW liquid level control relay RM35-L V AC/DC

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

TM3TI8T module TM3-8 inputs temperature

SR3B261FU modular smart relay Zelio Logic - 26 I O V AC - clock - display

SR3B261FU modular smart relay Zelio Logic - 26 I O V AC - clock - display

SR2A201FU compact smart relay Zelio Logic - 20 I O V AC - no clock - display

ABL8MEM12020 regulated SMPS - 1 or 2-phase V AC - 12 V - 2 A

SR2B121B compact smart relay Zelio Logic - 12 I O - 24 V AC - clock - display

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA 250 V AC

ABE7H16R11 passive connection sub-base ABE7-16 inputs or outputs - Led

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

Transcription:

Characteristics safety controller XPS-MC - 24 V DC - 16 input - 32 LEDs signalling Main Range of product Product or component type Safety module name Preventa Safety automation Kit configurable safety controller XPSMC Safety use category Category 4 maximum conforming to EN 954-1/EN/ISO 13849-1 PLE maximum conforming to EN/ISO 13849-1 SIL 3 maximum conforming to IEC 61508 Type of start Configurable Standards EN 1760-1/ISO 13856-1 EN 574/ISO 13851 EN 954-1/EN/ISO 13849-1 EN/IEC 60204-1 EN/IEC 60947-5-1 EN/IEC 61496-1 IEC 61508 Product certifications CSA TÜV UL [Us] rated supply voltage 24 V DC - 20...20 % Number of inputs 16 Communication port protocol CANopen with 1 SUB-D 9-pin male port(s), serial link, transmission rate: 20 kbps, 50 kbps, 125 kbps, 250 kbps, 500 kbps, 800 kbps or 1 Mbps Modbus with 1 RJ45 port(s), serial link, transmission rate: 1200 bps, 2400 bps, 4800 bps, 9600 bps or 19200 bps Safety level Can reach PL e/category 4 conforming to EN 954-1/EN/ISO 13849-1 Can reach SIL 3 conforming to IEC 61508 Complementary Kit composition CANopen SUB-D female connector 180 CANopen SUB-D female connector 90 Configuration software Connection cable Ethernet cable 2m Packaging small model for software configuration Printed packaging label 80 x 50 mm Safety controller Set of cage clamp terminals Set of screw terminals USB/RS485 converter VDE slot screwdriver 2.5 x 75 mm 5-Apr-2019 1 Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications

Function of module Synchronisation time between inputs Power consumption in W Input protection type [Uc] control circuit voltage Line resistance Output type Breaking capacity Breaking capacity Output thermal current [Ith] conventional free air thermal current Associated fuse rating Minimum output current Minimum output voltage Response time Dynamic monitoring of hydraulic valves on linear presses Eccentric press Emergency stop monitoring, with or without time delay, 1 or 2-channel wiring Enabling switch monitoring, 2 or 3 contacts Foot switch monitoring Guard monitoring for injection presses and blowing machines Guard monitoring with 1 or 2 limit switches Hydraulic press Magnetic switch monitoring Monitoring safety stop at top dead centre on eccentric press Muting function of light curtains Position selector Safety mat monitoring Safety time delays Shaft/chain breaking monitor Zero speed detection Light curtain monitoring (category 4) conforming to EN/IEC 61496 Two-hand control (category 3) conforming to EN 574/ISO 13851 Depending on configuration selected 12 W External fuse 16 A 28.8 V 100 Ohm 2000 m 2 relays, 2 NO contacts (4 NO total) circuit(s) Solid state, 6 circuit(s), volt-free C300: holding 180 VA AC-15 relay output C300: inrush 1800 VA AC-15 relay output 1.5 A/24 V - L/R = 50 ms, DC-13 relay output 2 A/24 V for static output circuit 4 A for both outputs simultaneously 6 A for 1 output and 2 A for the other relay output <= 16 A for relay output <= 6.5 A for static output circuit 16 A gl for power supply 4 A gl for relay output 6 A fast blow for relay output 10 ma relay output 17 V relay output Configurable : 20 ms or 30 ms with software XPSMCWIN [Ui] rated insulation voltage 300 V, degree of pollution 2 conforming to IEC 60647-5-1, DIN VDE 0110 part 1 [Uimp] rated impulse withstand voltage 4 kv overvoltage category III conforming to IEC 60647-5-1, DIN VDE 0110 part 1 Method of access Exchange size Number of addresses Parity Data format Supported modbus function Local signalling Mounting support Depth Height Width Product weight Slave 14 words 1...247 Modbus 1...127 CANopen Even Modbus No Modbus Odd Modbus 1 start bit/8 data bits 1 stop bit even or odd 2 stop bits without parity RTU (Remote Terminal Unit) mode 01: 8-bit output data/32-bit input data 02: 32-bit input data/8-bit output data 03: information and errors 32 LEDs Mounting plate 6.02 in (153 mm) 5.96 in (151.5 mm) 2.91 in (74 mm) 1.81 lb(us) (0.82 kg) 2

Environment IP degree of protection IP20 conforming to EN/IEC 60529 Ambient air temperature for operation 14...131 F (-10...55 C) Ambient air temperature for storage -13...185 F (-25...85 C) Contractual warranty Warranty period 18 months 3

Dimensions Drawings Dimensions 1 When using XPSMCTS connectors this dimension is 153 mm (6.02 in) When using XPSMCTC connectors this dimension is 151,5 mm (5.96 in) 4

Mounting and Clearance Installation Metal adaptor for fixing on metal: DIN rail 35 mm/1.38 in. 5

Connections and Schema Wiring Diagrams Refer to the Instruction Sheet To download the instruction sheet, follow below procedure: 1 Click on Download & Documents. 2 Click on Instruction sheet. 6

Technical Description Safety Functions Emergency stop monitoring with time delay: 1 channel wiring, with automatic start. 2 channel wiring, with start button. Emergency stop monitoring without time delay: 1 channel wiring, with automatic start. 2 channel wiring, with start button. Two-hand control. Guard monitoring: with 1 limit switch. with 2 limit switches. with 2 limit switches, with guard locking. Guard monitoring for injection presses and blowing machines. Magnetic switch monitoring. Sensing mat monitoring. Light curtains monitoring: Relay output type. Solid-state output type. Muting function for light curtains. Zero speed detection. Dynamic monitoring of hydraulic valves on linear presses. Safety time delays. 7

Other functions: Foot switch monitoring Chain shaft breakage monitoring Position selector Monitoring safety stop at top dead centre on eccentric press. Hydraulic press. Eccentric press. Enabling switching monitoring: 2 contact type. 3 contact type. 8