Esensors. Websensor User Guide. Save trees. Print only when necessary

Similar documents
Instruction Manual. Power Meter PM01. AC line voltage monitor. Version 2.0

Instruction Manual. HVAC Monitor Model EM32-F. Wi-Fi Websensor. Version 6.0

Websensor Add-on: ES11 Flood Sensor User Manual

SD1306. Speed Dome IP Camera. Quick User Guide

USB Server User Manual

Plus-X 300. Installation and Operation Manual

BrewTroller Phoenix. Owners Manual. Updated - March 14, 2016 BREWTROLLER PHOENIX 1

Innovative Electronics for a Changing World. NPM-R10 Remote Network Power Monitor. With optional relay board and GSM module INDEX

INDEX. Network Power Monitor R10 SNMP

Plus-X 600. Installation and Operation Manual

Innovative Electronics for a Changing World INDEX

PWRguard PLUS Spring City Drive Waukesha, WI

Plus-X RP-8 Adapter. Installation and Operation Manual

Plus-X Dual IP-8 Adapter. Installation and Operation Manual

User Guide. Wireless Router

DESCRIPTION. The DC-RMCU1 comes with the DuraComm three-year warranty.

Dolphin ebase. Communication Cradle for the Dolphin 9700 Mobile Computer. User s Guide

Plus-X AC-8. User Guide

INDEX. Network Power Monitor NPM-R10-SNMP. Innovative Electronics for a Changing World. NPM-R10-SNMP Remote Network Power Monitor

AVer FD1020. Quick User Guide

212iL Rev. 1.1

Industrial. micro USB Module

Industrial mini SATA III Flash Module

Apricorn Aegis Secure Key

Quick Installation Guide

zclock-200w User Manual

Firmware Updates Model 24 / 44 / 42 Cryogenic Temperature Controllers

IIT-ECON-8 Configuration. Rev 1.00

KEYPAD MODEL USER MANUAL

Industrial M SATA III NGFF SSD

PlusConnect BDI DPS-100D. Installation and Operation Manual

Carefree-Security. Installation and programming instructions 1050A. Owner s Manual

Instruction Manual for IEEE Prototyping Kit (PC Version)

12-Bay Docking Station Standard Battery Version User Guide

User s Guide. OM-CP-PRHTEMP2000 Pressure, Humidity and Temperature Data Logger with LCD

FC2020-P1. Cube IP Camera. Quick User Guide

Aegis Padlock DT. User s Manual

pakedgedevice&software inc.

MLC. Mini SATA III Flash Module. HERMES-JI Series. Product Specification APRO MLC MINI SATA III FLASH MODULE

zpen-1080p Features zpen-1080p Layout

Owner s Manual. Date of installation: Installed by: Installer phone#: Serial #:

Longshine Technologie Europe GmbH

PWRcheck Spring City Drive Waukesha, WI

Installation of the PCMeasure Movement Sensor (30114)

SpeedVault Model SV 500 User Manual

MLC 2.5 SATA III SSD

Instruction Manual Environmental Monitoring Unit with Optional POE. Watchdog 15 Series Firmware Version 1

SAFETY INSTRUCTIONS Be careful with electricity: Power cord Lightning Ventilation Overheating Risk of Fire Proper Connections Object Entry

Telephone System SYSTEM GUIDE

MF25A. Wireless Router Quick Start Guide

SATA II HDD Canister KISS DA 435 Quick Reference Guide

It s Under Control. Installation and Operation Guide CPB-1. Control Port Connecting Block V 1.1

TABLE OF CONTENTS COPYRIGHT INTRODUCTION...3 PRODUCT OVERVIEW...3 COMPONENTS AND FEATURES...3 HARDWARE INSTALLATION

LabelWriter. Print Server. User Guide

OZONE SWITCH Model OS-6. OS-6 Features

Remote Control for Inverter RC-300. Owner's Manual. Please read this manual BEFORE operating your RC-300 Remote Control

Ambient Weather WeatherBridge Nano Weather Station Server for Davis Instruments Quick Start Guide

IpAlarm Module Set Up

Chapter 1 : FCC Radiation Norm...3. Chapter 2 : Package Contents...4. Chapter 3 : System Requirements...5. Chapter 4 : Hardware Description...

Universal Switch Panel USP-KEYSERVER. User Manual

B Polling Interface

UPS COMMUNICATION Web Card

Wi-Fi HDD Docking Station WITH SuperSpeed USB 3.0

USERS GUIDE MCX-VTH. VGA to HDMI Converter. Manual Number:

Lab - Connect to a Router for the First Time

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features

Moxa Remote Connect Gateway User s Manual

EPSON PreferredSM Limited Warranty Program for the Epson Stylus

UTelligent Management System UMS UMS-SH-A1 UMS-SH-B1. Quick Start Guide V1.4.0

THECHARGEHUB.COM. User Manual. For Square & Round Models

MLC 2.5 PATA SSD. HERCULES-Q Series. Product Specification MLC APRO RUGGED METAL 2.5 PATA SSD. Version 01V0 Document No. 100-xR2IF-MQTMB June 2016

PCMCIA Flash Card User Guide

TP-LINK TD-W9970 Wireless ADSL2+ Modem Router

General Notice Introduction Functional Description Product Troubleshooting Driver Setup...

Global Water globalw.com. Global Water. Instrumentation, Inc.

MLC. Semi Metal USB. Generation 5 / 5L HERCULES-PB Series. Product Specification MLC. Semi Metal USB Flash Disk Generation 5/5L

aslc Mini SATA III Flash Module PHANES-HR Series Product Specification APRO aslc MINI SATA III FLASH MODULE

MLC. Semi-Metal USB. Generation 3L HERMIT-C Series. Product Specification MLC. Semi-Metal USB Flash Disk Generation 3L

Industrial 2.5 PATA SLC SSD. HERCULES-Q Series. Product Specification INDUSTRIAL APRO RUGGED METAL 2.5 PATA SLC SSD

Xxxxx Xxxxxx Bridge / Strain Gauge Data Logger

DTX SERIES. DTX RG 301W Operations Manual (Software Release 3.0)

PoE Digital Clock. PoE Digital Clock Installation and User Guide

QUICK GUIDE. Camera Installation for iphone, ipad, Android smart phone and tablet

SATA III MLC CFast Card

MF920V Quick Start Guide

2.5 SATA III MLC SSD

VP Process Inc. Model: VP-EC-RDU Modbus RTU LCD Display

ASCL1 / ASCL2. CarLink Guide for BlackBerry Users Audiovox Electronics Corporation. All rights reserved.

LEGAL INFORMATION. Copyright 2014 ZTE CORPORATION. All rights reserved.

Industrial Semi Metal USB

EPSON Preferred. Priority Technical Support. Toll-Free Phone Number. Security and Peace of Mind. On-Site Repair

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features

HDMI Extender over Ethernet, with RS232, POE

CF15118 CompactFlash Carrier utilitymodules User s Manual

hyperion ! This device requires a downloaded phone app in Instruction Manual Data Transfer Module

60 GHz Wireless Dock Basic Model

MLC MICRO SATA III FLASH MODULE

Wireless Location Receiver PLK-TR015-10

Power Xpert Meter 2000 Series

ES-600 Ozone Controller Operation Manual

Transcription:

Esensors Websensor User Guide EM32 Le, Xe Websensors SM1 Le, Xe Soil Moisture sensors AQUO Le, Xe Water sensors PM01 Voltage/ Current Sensors IOT Interfaces Save trees. Print only when necessary

ii

COPY RIGHTS The information in this document is subject to change without notice and should not be construed as a commitment by Esensors, Inc. While every effort has been made to assure the accuracy of the information contained herein, Esensors Inc. assumes no liability for damages from the use of the information contained in this manual. All software described in this manual is furnished under a license and may be used or copied only in accordance with the terms of that license. COPYRIGHT 2017 by Esensors, Inc. All rights reserved. Websensor and the Websensor logo are trademarks of Esensors Inc. Other products or company names are or maybe the trademarks or registered trademarks and are the property of their respective owners. No part of this publication may be reproduced, photocopied, stored on a retrieval system or transferred without the expressed written consent of Esensors, Inc. iii

LIMITED WARRANTY This limited warranty is granted to the customer by Esensors, Inc. and extends only to the original customer performing the purchase of Esensors product. The goods you purchased are warranted free from defects in workmanship and materials at the time of sale. If a product exhibits a manufacturing defect, Esensors Inc. will, at its option, repair or replace it (with the same or equivalent model), with no charge to you. If the limited warranty period is not explicitly stated on any prior written agreement, then the limited warranty defaults to one (1) year from invoice date. Damage resulting from accidents, alterations, failure to follow instructions, incorrect assembly, misuse, unauthorized service, fire, flood, power surges, acts of God, regular wear and tear or other causes not arising from manufacturing defects is NOT covered by this warranty. If the product is altered in any way, the warranty is voided. Esensors Inc. or its suppliers will not be liable and will not compensate for loss of time, inconvenience, loss of the use of the product, property damage caused by the product, personal injury and/or death arising from the use of this product, its failure to work or any other incidental or consequential damage arising from the usage of this product. Esensors Inc. provides no warranty, expressed or implied, as to the fitness of the products for any particular purpose. Parts used in repairing or replacing the product will be warranted until the original warranty expires. Products or parts that malfunction and are not warranted will be replaced or repaired and then shipped entirely at the expense of the customer. This warranty is given in lieu of all other warranties, expressed or implied, including the warranties of merchantability and fitness for a particular purpose and constitutes the only warranty made by Esensors, Inc iv

CONTENTS Websensor User Guide... 1 1. Introduction... 6 2. Getting Started... 6 3. User Interface... 8 4. Network Configuration... 8 5. Sensor Settings... 12 6. IOT Interface Configuration... 13 7. Offset and slope calibration... 15 8. Email Configuration... 16 9. Cloud Push Setup... 17 10. SNMP Configuration... 17 11. Appendix... 17 v

1. Introduction Congratulations on purchasing your Websensor. This user manual will get you started with the initial configuration and settings for your sensor unit. EM32 Le PM01 EM32 Xe PM01 Xe AQUO Le IOT Interfaces AQUO Xe 2. Getting Started A Quick look at your websensor. Snooze/ Reset Ethernet Power NO Comm NC Relay Port Expansion Port for IOT Sensors (Level, Flow,Pressure, RTD,Prox Flood Sensor Temperature/ Humidity Sensor Spot Level Sensor/ Contact Input/ Thermistor GSM Sim Slot Voltage Sensor 6

Features and available ports may vary depending on the model of websensor you have, and on your choice of sensors, connectivity options and peripherals. To learn which features are available on your device,check out the product page on our website. For models with GSM enabled, SIM card may not be included. Pick a service provider based on the location and availability of mobile service providers as fit for your application. Services that send or receive data over a cellular network may incur additional fees. Check with your carrier for information about your service plan and fees. 7

3. User Interface The Websensor provides a simple and easy to use web interface. All settings on the sensor are accessible under different tabs in the navigation menu. If you are using a tablet of a phone, the navigation switches to a drop down menu. Simply click on the tabs, and you can access, modify, and save settings to match your requirements. Note: Depending on the firmware version of your sensor, the user interface theme may vary. 4. Network Configuration Your Websensor model may have Ethernet, and optionally WiFi, GSM or both. Ethernet interface is enabled by default. The network configuration and other settings pages are open by default, but can be password protected. 8

Configuring via Ethernet To configure and use your sensor with Ethernet connection, connect the sensor to a PC, switch or router via an Ethernet cable. Then Power up your sensor with the micro USB cable and power adaptor included in the package. By default, Websensor boots up in DHCP mode. When booting in DHCP mode, models with built-in LCD display will show the IP address on the top right part of the display. For models without display, you will need to check the DHCP client list to identify the IP Address. Alternatively, If you prefer the sensor to boot up in static IP mode, then keep the reset button pressed before you power up the sensor. Now the sensor will boot in static IP mode. In static IP mode, the default address for the Websensor is 192.168.254.102. This requires that the PC being used to configure the Websensor has its network interface card (NIC) set with the same subnet address: 192.168.254.*** This can be changed in the network and sharing center of your PC or Mac. Pick an IP that is different from that of the Websensor. NOTE: Before you make any changes, please Note down your PC s original settings so that after the configuration is done, you can set your PC back to its original settings. A sample setting you can temporarily assign your PC is given below. IP address: 192.168.254.110 Subnet: 9255.255.255.0 Router: 192.168.254.1 Primary DNS: 192.168.254.1

Once you have your PC on the same subnet as the Websensor, the Websensor is connected to it and powered via the supplied DC Wall Supply, the Websensor can be queried by typing the following command into the address line of a web browser. http://192.168.254.102 Once the default IP address is entered, the browser screen should display the Sensor Web Interface page.. For models with WiFi If your websensor is WiFi enabled, An access point network will be available for the first 30 minutes during power up. Using a laptop, tablet, or a similar wifi enabled device, search for EsensorSetup-xxxxx network where the xxxxxx represents the serial number of your device. Connect to this open network. Then, open a web browser and type in the default Access point IP of the device http://192.168.4.1 Follow the instructions on the screen to connect your sensor to your home or office network. Once setup is finished, you can access the rest of the device settings. 10

From the NETWORK CONFIGURATION screen it is possible to change the various network settings involved in any IP addressable device, port number for the webpage, DNS, gateway, admin ID and password. You can choose to enter the information manually, or you can enable DHCP which will automatically assign IP and other network parameters to the device. Once changes are made, Click Save for the changes to take effect. When you change the IP address though the webpage interface, the next page displayed is the Reboot in Progress page. Wait for the websensor to save the settings. This usually takes 10-30 seconds. Point your browser to the new IP address and you should see the home page. Note: If you get the message Error: Connection to the sensor was lost this is because the browser still points to the old IP address. When the new IP address is entered into the address bar the screen will correctly display the Home Page. Setting Device Time There are two ways to set device's clock. One is to let device automatically synchronize its clock from Internet every day. The network configurations like gateway and DNS must be properly set for this feature since device need Internet access. Another way is to set device's clock manually. This can be done by 11

click "Set Device Clock" button in Network Configuration webpage. Device does not need Internet access in this mode. The disadvantages are: the clock need to be set whenever device is re-powered since it can not save time when power lost. 5. Sensor Settings This page holds the sensor thresholds and time settings for the various sensors supported on your device. For sensors with varying measurements (eg: Temperature), Settings options consists of the following minimum fields. Lower threshold: If the sensor reading is below this value, an alarm will be triggered. Upper threshold: If the sensor reading crosses above this value, an alarm will be triggered Trip time (Threshold is violated, and Stays there for ): This is the time that the sensor must stay beyond the threshold for an alarm to be triggered. Eg: For temperature sensor, if lower threshold is set to 65 ºC, and trip time is 5 seconds, An alarm is triggered if temperature drops below 65 ºC and stays below 65 ºC for 5 seconds or more. Similarly with for upper thresholds. Same logic is applicable for other sensors unless otherwise specified. Alarm Return/ reset Time: This is the time that a sensor must stay in its normal range (after it returns from an alarm) for the alarm to be reset. Eg: if the temperature sensor is reading below 65 ºC and an alarm is triggered, and if Alarm reset time is set to 60 seconds, the sensor must come back and stay above 65 ºC for 60 seconds or more for the previous alarm to be reset. 12

Onboard LED Indicators The websensor has two LED indicators, the Main LED Indicator on the front face and a flasher LED on the RESET button. When the websensor is turned on, the Main LED turns RED while it waits for an IP address. If the sensor is configured to boot in DHCP mode, Main LED remains RED until the IP is received. At this point, it turns green. During this time, the flasher LED will be off. Once the websensor is configured and running, If one or more of the sensors go to alarm mode, the Main LED will turn red and the flasher LED will start to flash. The flasher will continue to flash until the time set for snooze buzzer on the settings page has expired. At that point, the flasher will stop blinking and remain solid red. Once the sensor readings are back to normal, the Main LED will turn green, and the flasher LED will turn off. 6. IOT Interface Configuration Due to the large number of sensor choices, most models under the IOT Interface category are shipped without stock sensors. The interface is designed such as to accommodate a wide range of sensors of your choice. Physical Connection IOT Interfaces are shipped with a 3 pin terminal block interface which intern connects to a 3 pin stereo input. The pinout for this interface is as follows. 13

SIGNAL PWR GND Power pin can provide 3 different voltage levels which can be set on the settings page. This includes 3.3V (Default) 5V 12V Your sensor may or may not need to use this power source. It is given only as an option. CAUTION: Due to the present of a supply voltage available on the terminal, It is highly recommend while connecting or disconnecting the sensors, unplug the power to the sensor interface unit itself. After you complete the connections, you may power up the interface. Signal Types The signal pin can accept the following type of signals. Voltage (upto 5.5V) Current (4-20mA) RTD (PT100, PT1000) Resistance Input (eg: Level Sensors) Prox Switches 14

Each of these signals will be directed to different channels through a built-in multiplexer. You may select the type of signal on the sensor settings page based on your sensor specification. Signal Limits/ Gradient Settings Settings options are provided to enter the signal values at zero and full scale readings of the sensor. This is used to calculate the gradient/ slope for calculating the values. Eg: A pressure sensor with 4-20mA type signal and a range of 0 to 20 PSI will have the following settings values Current at zero (min reading): 0 ma Current at full scale (max reading: 20mA. It is recommended to leave the Gradient field blank for automatic calculation. Data Units Multiple data units are available for selection based on your sensor, and application. A percentage fullscale unit is also available for few select types. NOTE: Based on the type of unit you select, make sure that all the appropriate values are entered based on this unit. 7. Offset and slope calibration To correct for offsets, and gradient slopes, a calibration interface is available on the settings page. For some sensors, a basic offset 15

calibration is provided. For IOT interfaces, offset adjustments as well as an advanced 2 point slope calibration option is available. 2 Point Curve Correction For the 2 point curve correction method, a live feed of raw data is provided right below the input fields. First set the sensor to the zero level, and observe the raw value. Enter this value in the minimum measured value field. Now, set the sensor to the max value, and observe the raw reading. Enter this value in the max value field. Click to save calibration settings. Check the home page to see corrected values. If needed, perform calibration again. You can choose between offset correction and curve correction based on the observed reading. If the offset is fixed, then a simple offset correction may be sufficient. It may be noted that Slope correction is done to the raw input signal, where as offset is applied to the final result. 8. Email Configuration The Email Configuration can be accessed by clicking on the email tab of the navigation menu. The basic setting only needs a To Email address. On advanced settings, options to configure your SMTP server settings are provided. Enter the settings for the SMTP server and port number. Contact your email service provider to get information about your SMTP server and port number. 16

Enter the recipient email(s) separated by commas. 9. Cloud Push Setup Basic instructions are provided on the Cloud tab web page itself. Sensor-side settings Advanced Websensor/ IOT Interfaces (XE versions) allows you to push data to remote servers. Simply provide the server configuration information, Save the settings Server-side settings On the server side, include a script (which is what you provide on the sensor-side as the target file) which contains the necessary script to parse XML. You can save the data in any format you choose, or you can enter them into databases for further processing. 10. SNMP Configuration SNMP v2c is available on all models. Advanced (XE) versions support SNMP V3. MIB file is available for download on the SNMP page of the web interface. 11. Appendix Data output Data from the sensor can be accessed via the following methods 17

a. Http web interface: This is the simplest way of accessing data. Simply type in the IP address of the device onto any standard web browser, and the device returns sensor data through an elegant web interface b. XML Interface: More friendly towards machine-to-machine interfaces, the XML output provides all sensor data with tags that can be parsed for further processing. A sample looks like below. c. JSON interface. Same data, in JSON format. d. Push Method: See section 7 e. SNMP: See section 8 18

Basic Troubleshooting Instructions 1. Did you change the IP address? The DHCP server probably assigned the device a new IP address, but your computer's network cache has saved the wrong address. From the command prompt in Windows, enter "nbtstat -R" or "arp -d" to clear old values and try again. Make sure you launch the command prompt as administrator. 2. Did you try the IP address? Try accessing the device directly at the IP address you entered if DHCP was turned off. (Example: if you entered 192.168.5.23 as the IP, enter "http://192.168.5.23/" into your browser). If this fails, then the IP address you used is not reachable. Accessing device via IP address is more reliable than using host name since some networks may have troubles dealing with host name. If you forgot the IP address and the host name of EM32 device, try Step 3 below. 3. Settings not saved, Sensor reboots by itself or when trying to update settings? Try clearing the cache on your browser. Trying a different browser can also help in some cases. If these do not help, a device reset is recommended. 19

4. Still not working? Device Reset You can restore the factory default settings by erasing the device's flash ROM. Snooze/ Reset Ethernet Power NO Comm NC Relay Port Resetting your sensor unit Simply Press and hold the Snooze/ Reset button for about 5-6 seconds until you hear a long beep. Got questions? Write to us: support@eesensors.com We prefer email, but you can call us too. +1.716.837.8719 20

Save trees. Print only when necessary 21