TSXPAY262 Preventa safety module - 24 V DC - standard format - < 5 W

Similar documents
TSXCTY2A 2 channels counter modules - 40 khz - 30 ma at 24 V DC, 280 ma at 5 V DC

ABL8WPS24400 regulated SMPS - 3-phase V - 24 V - 40 A

ABL8RPS24100 regulated SMPS - 1 or 2-phase V - 24 V - 10 A

ABL8BBU24400 battery control module V DC - 24 V - 40 A - for regulated SMPS

XPSMP11123P module XPS-MP - 2 independent functions - 24 V DC

XCKM102 limit switch XCKM - steel roller plunger - 1NC +1NO - snap action - Pg11

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

RM35TF V AC

ABL8RPS24100 regulated SMPS - 1 or 2-phase V - 24 V - 10 A

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

XPSMC16ZP safety controller XPS-MC - 24 V DC - 16 input - 32 LEDs signalling

XPSMCMDI Input expansion module with screw term

ABL8WPS24200 regulated SMPS - 3-phase V AC - 24 V - 20 A

XPSMC16Z safety controller XPS-MC - 24 V DC - 16 input - 30 LEDs signalling

XPSMC16ZCPACK safety controller XPS-MC - 24 V DC - 16 input - 32 LEDs signalling

XPSMCMDO Digital output pairs expansion modules with screw term

XPSMC16ZPPACK safety controller XPS-MC - 24 V DC - 16 input - 32 LEDs signalling

XCKJ10541H29 limit switch XCKJ - th.plastic roller lever var. length - 1NC+1NO - snap - M20

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

RXM4AB1MD Miniature Plug-in relay - Zelio RXM 4 C/O 220 V DC 6 A

XCKS141H29 limit switch XCKS - th.plastic roller lever var. length - 1NC+1NO - snap - M20

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

XPSMC32Z safety controller XPS-MC - 24 V DC - 32 input - 46 LEDs signalling

XPSMCMMX inputs 2 output pairs expansion module with screw term

ABL8RPS24030 regulated SMPS - 1 or 2-phase V - 24 V - 3 A

ABE7R16S210 sub-base - soldered electromechanical relays ABE7-16 channels - relay 10 mm

TM3SAC5RG SAFETY MODULE FOR PLC TM2xx, 1 FUNCTION, CAT3, SPRING TERMINALS

XPSMC16Z safety controller XPS-MC - 24 V DC - 16 input - 30 LEDs signalling

TSXCCY1128 electronic cam module cams - 1 axis - 7 W

ABL8RPS24100 regulated SMPS - 1 or 2-phase V - 24 V - 10 A

ZB5FG09 flush mounted selector switch head key pos stay put

STBEHC3020KC counter kit STB - 1 CH Hz - 2 I

XCKJ10511 limit switch XCKJ - thermoplastic roller lever - 1NC+1NO - snap action - Pg13

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term

XB7NS8442 Emergency stop Ø 22 - red - mushroom head Ø 40 mm - turn to release - 1 NC

XCKS131 limit switch XCKS - thermoplastic roller lever - 1NC+1NO - snap action - Pg13

XB5AS8445 red Ø40 Emergency stop, switching off Ø22 trigger latching turn release 1NO+1NC

XCKL115 limit switch XCKL - thermoplastic roller lever - 1NC+1NO - snap - Cable gland

TM3SAF. Main. Device short name

BMXMSP0200 PTO module - 2 channels - 4 input - 24 V DC ma - 2 connectors 28 pins

XCKD3918P16EX limit switch XCKD - roller lever - 2NC + NO - ATEX/IECEx

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

XCKN2110P20 limit switch XCKN - metal end plunger - 1NC +1NO - snap - M20

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

XUSL4E14F046N XUSL type 4 - Finger protection - Std sensing range - Hp = 460 mm, R=14mm

ILA1F572PB1A0 integrated drive ILA with servo motor V - CANopen - PCB connector

XB7NA4234 PB - Spring Rtn, red - 1NC -White "STOP"

TM7NCOM16A CANopen interface block - IP67-16 I/O - M12

BMXAMI0410 analog input module M340-4 inputs - high speed

XB4BT845 Red Ø40 Emergency stop, switching off Ø22 latching push pull 1NC+1NO

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

TM3DI16 module TM3-16 inputs

XB7NG33 key selector switch - Ø 22 - keylock - 3 positions - 2 NO - Ronis 455 center

XCKP2110G11 limit switch XCKP - metal end plunger - 1NC+1NO - snap - Pg11

RM17UB3. Price* : USD

XCKJ10541H29 limit switch XCKJ - th.plastic roller lever var. length - 1NC+1NO - snap - M20

XCKJ10559H7 limit switch XCKJ - thermoplastic round rod lever 6 mm - 1NC+1NO - snap - 1/2NPT

ABE7H16R11 passive connection sub-base ABE7-16 inputs or outputs - Led

RM35LM33MW liquid level control relay RM35-L V AC/DC

XCKN2118G11 limit switch XCKN - thermoplastic roller lever - 1NC+1NO - snap - Pg11

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

XCKP2145N12 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - 1/2NPT

TM3SAK. Main. Device short name

BMEP processor module M580 - Level 1 - Distributed

SD328AU68S2 motion control stepper motor drive - SD328 - <= 6.8 A

BMXCPS3020H power supply module X V isolated DC -

LXM28AU07M3X motion servo drive - Lexium 28 - single and three phase V W

XCMD2110L1 limit switch XCMD - metal end plunger - 1NC +1NO - snap - 1 m

RM35JA32MR Current control relay 0.15A 15A, 2 C/O

XUX9ARCNT16 photo-electric sensor - XUX - polarised - Sn 11m VAC/DC - terminals

XUSL2E30H166N XUSL type 2 Hand protection - Std sensing range - Hp = 1660mm, R=30mm

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

ATS22D88S6U. ATS22D88S6U soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Product data sheet Characteristics.

XUSL4E30H151N XUSL type 4 - For hand protection - Std sensing range - Hp = 1510 mm, R=30mm

RM4JA01F current measurement relay RM4-J - range ma V AC

ATS22C21S6U softstarter-ats22-control110vpower208v(60hp)/230v(75hp)/460v(150hp)/575v(200hp)

XUSL4E14F121N XUSL type 4 - Finger protection - Std sensing range - Hp = 1210mm, R=14mm

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

RE22R2CMR Off-delay Timing Relay s 300h V AC/DC - 2C/O

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

TM258LD42DT4L compact base M I/O - 24 V DC

TSXCCY1128 electronic cam module cams - 1 axis - 7 W

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

ILS1M851PB1F0 integrated drive ILS with stepper motor V - I/O for motion sequence - 5A

TM7BDM16A expansion block - TM7 - IP67-16 DI/DO - 24V DC A - M12 connector

RE22R2KMR Off-delay Timing Relay s 10min V AC/DC - 2C/O

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

ATV32HU75N4 variable speed drive ATV kw V - 3 phase - with heat sink

RM4JA32MW current measurement relay RM4-J - range A V AC DC

RSB1A160JD interface plug-in relay - Zelio RSB - 1 C/O - 12 V DC - 16 A

ABL1REM24025 regulated SMPS - single phase V input - 24 V output - 60 W

140ERT85420 multifunction input module Modicon Quantum - 32 I - IRIG-B - DCF77

RM4TR31 three-phase network control relay RM4-T - range V

ABR1S102B. Main. Contacts type and composition [Uc] control circuit voltage Control circuit type

TM3AI4 module TM3-4 analog inputs

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

ABL4RSM24050 regulated SMPS - 1 or 2 phase V AC - 24 V - 5A

K1D004ACH cam switch - 4-pole A - for Ø 22 mm

RM22LA32MR Level control relay RM22-L V AC/DC - 2 C/O

XCKP2110N12 limit switch XCKP - metal end plunger - 1NC +1NO - snap - 1/2NPT

Transcription:

Characteristics Preventa safety module - 24 V DC - standard format - < 5 W Main Range of product Product or component type Complementary [Us] rated supply voltage Supply voltage limits Activation threshold Short-circuit protection Modicon Premium Automation platform Preventa safety module 24 V DC 19.2...30 V < 20 V Isolation voltage 4000 V III 2 1 A gg external conforming to IEC 947-5-1 on power supply 4 A gg external conforming to IEC 947-5-1 on safety relay outputs Discrete input number 1 double or single contact selection input conforming to IEC 1131 Type 1 1 feedback loop input conforming to IEC 1131 Type 1 1 reset PB input conforming to IEC 1131 Type 1 1 reset PB monitoring input conforming to IEC 1131 Type 1 12 emergency stop or limit switch discrete inputs conforming to IEC 1131 Type 1 Discrete input logic Inrush current Isolation between input and earth Power dissipation in W Safety outputs [Ue] rated operational voltage Rated power in VA Rated power in W [Ithe] conventional enclosed thermal current Minimum output current Response time on output Positive <= 0.5 A 500 Vrms 50/60 Hz for 60 s < 5 W 2 NO safety relay AGCDO gold plated volt free output 17...127 V DC relay output 19...250 V AC relay output 120 VA 48 V AC-15 inductive 280 VA 110 V AC-15 inductive 550 VA 220 V AC-15 inductive 60 VA 24 V AC-15 inductive 60 W 24 V DC-13 inductive 100 ms <= 2.5 A >= 30 ma < 12 ms Isolation between output and earth 300 V conforming to DIN VDE 0110 part 2 1500 Vrms 50/60 Hz for 60 s Safety acquisition Apr 6, 2019 Monitor external power supply of the module Read enable inputs 1 Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications

Local signalling Electrical connection Cable cross section Current consumption Module format Product weight Read feedback loop Read the safety outputs control Read status of the 24 inputs 28 LEDs diagnostic of safety system 1 connector removable screw terminal block 6 pins for connecting the safety output 1 connector SUB-D 44 pins for connecting the safety system input 1.5 mm² with cable end safety output circuit 0.2...2.5 mm² without cable end safety output circuit < 150 ma 5 V DC <= 200 ma 24 V DC Standard 0.43 kg Environment Ambient air temperature for operation Ambient air temperature for storage -25...70 C 0...40 C without fan 0...60 C with fan module IP degree of protection IP20 conforming to IEC 60529 Standards Product certifications CSA C22.2 specific requirements (PLC) EN 954 machine safety parts of control systems EN/IEC 60204-1 machine electrical equipment EN/IEC 61131-2 specific requirements (PLC) EN/ISO 12100 machine electrical equipment ISO 13850 emergency stop equipment UL 508 specific requirements (PLC) ISO 13849-1 category 4 machine safety parts of control systems IEC 61508 SIL 3 machine safety parts of control systems BG CSA UL Offer Sustainability RoHS (date code: YYWW) REACh Product end of life instructions Compliant - since 0927 - Schneider Electric declaration of conformity Schneider Electric declaration of conformity Reference not containing SVHC above the threshold Reference not containing SVHC above the threshold Need no specific recycling operations Contractual warranty Warranty period 18 months 2

Dimensions Drawings Standard and Extendable Racks for Modules Mounting Dimensions of Modules and Racks (1) With screw terminal block modules. (2) Maximum depth for all types of modules and their associated connectors. 3

The Safety System 4

Connection of Emergency Stop Buttons and Safety Switches Double Contacts (recommended) Double contact wiring of inputs is suitable for applications requiring category 3 or 4 compliant levels of safety. Short circuits between channels are detected. ES PB or PS short circuits are detected and pinpointed. NOTE: If less than 12 double contacts are being used, the input terminals that are not in use must be bridged. Single Contact This wiring is not suitable for applications requiring category 3 or 4 compliant levels of safety. Not all errors are detected, nor are ES PB or PS short circuits. Here, pressing this PB will not cause the safety circuits to open (loss of the safety function). 5

NOTE: If less than 12 contacts are being used, the input terminals that are not in use must be bridged. 6

Safety Output Wiring Diagrams Feedback Loop Connection The category 4 immediate stop system design requires supply shut-off device redundancy and activation monitoring. Wiring of open contacts (K3, K4) or (K3, K4, K5, K6) allows every activation request to be checked. It is compulsory for the contacts of relays (K3, K4) or (K3, K4, K5, K6) to be mechanically linked. Category 3 wiring means: no wiring of auxiliary contacts in the feedback loop (a strap links terminals Y1 and Y2/S33), standard switches, with non-guided contacts, are sufficient. 2-switch set-up (category 4): 4-switch set-up (category 4): 7

Connection of the Safety System Reactivation Function Wiring Diagram for Automatic Reactivation Wiring Diagrams for Manual Reactivation With Reactivation button monitoring (recommended): Without Reactivation button monitoring: 8

Safety Outputs Wiring Diagram 13, 23: Independent supply inputs 14, 24: Safety outputs NOTE: Wires cross-section: with termination: 2 x 1 mm 2 /16 AWG or 1 x 1.5 mm 2 /14 AWG without termination: 1 x 2.5 mm 2 /12 AWG 9