STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Similar documents
POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

MONITOR Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

ANT CNTR DC ALRM LNB RX DC ALRM +18V OFF

Instruction Manual Model Block Translator

Model L 10MHz Frequency Source, Switch, Inserter

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

Enhanced Mini-Chansim Model VCS-232

RE-82 RACK MOUNT DIMMER OWNERS MANUAL. 8 X 2400Watts. Revision /29/2007

Model x-Series

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

Model No. ST200-S-RCP

PMDX-108-Output. 8-Channel Isolated Output Board for PC parallel port pins 2-9. User s Manual

MODEL No. SW1X8 RS422 SWITCHER

PagePac PAGEPAC PLUS ZONE EXPANSION UNIT V

Automated Tuner System Power Distribution Hub

F280XD Fiber-Optic RS-232 Modem Technical Manual

Series 8000 RF Signal Switch Solution

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Installation & User Manual for. the Model TM-1 Sound Monitor

ACLD Channel Opto-isolated Digital Input Board

TC1880 Series. 4/5/6/8 Channel RS-232 FIBER OPTIC MICRO MUX User's Manual

CMSA-100 Manual. Cinema Media Server Automation

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features

F2238A and F2245A Fiber-Optic EIA-530/MIL-STD Modem Technical Manual

MAXIMA+ Series Rotary Level Indicator

S-Band Redundant LNA Systems

iconverter 2-Module Power Chassis

TRC-190 User s Manual

OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR065-48S / OPR065-48R. Manual

TRC-190 User s Manual

DMX512-A 2.10 HUB. User Guide

V-9939B MICROPHONE ADAPTER

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features

PMDX-103. Parallel Port Isolator Board. User s Manual. Document Revision: 1.2 Date: 20 February 2007 PCB Revision: PCB-447B

IKS-G6524A/G6824A Series Quick Installation Guide

RS422 PORT SWITCHER REMOTE CONTROL PANEL

TB-100 ControLynx Terminal Block

smar Specifications and information are subject to change without notice. Up-to-date address information is available on our website.

ES-600 Ozone Controller Operation Manual

PMDX-170 Slotted Optical Sensor

DMX512-A 1.5 HUB. User Guide

INSTRUCTION MANUAL RA 19-5B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

Digital Lighting Systems, Inc.

AirTest Model CN9000 Series Sensor Controller

OPERATION MANUAL SMARTLAB USB 8 CHANNELS RELAY OUTPUT 8 CHANNELS PHOTO ISOLATOR INPUT BOARD

OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL

FA-2448 SIX POSITION Filter Wheel

Remote Microprocessor Control Panel. for use with the. Redi-Purge. High Efficiency Purge System

MAXIMA + Series ROTARY LEVEL CONTROL

Model 282 Total Interface Isolation Module Reference Manual Rev. A Print Table of Contents 1.0 General Description 2.

V-9908 MESSAGE/PAGE PANEL

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A

imaging Series Quartet Guide to Installation and Operation M

Series 8900 LAN. Operation Manual. Part Number (example configuration) Part Number (example configuration)

ASK-4 #101-DV AUDIO MONITORING SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS

INSTRUCTION MANUAL RA 19-7B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

SIAC-PS 3G SIGNAL ISOLATOR WITH POWER SUPPLY (PART NO. 8890) INSTALLATION INSTRUCTIONS

MAXIMA + Series ROTARY LEVEL CONTROL

INSTRUCTION MANUAL RA 19-6B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

Card Nest Universal 12 position card nest for all K-AB cards above and all other K-AB cards.

User Guide. DMXSM-H18 Splitter. DMXSM-H81 Merger. Document Release Aug Revision B

INSTRUCTION MANUAL RA 19-4B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

87421/22A Power Supply. Operating and Service Manual

Series 8000 RF Signal Switch Solution

Installation & Operation Guide

V-9941A ONE ZONE HANDSFREE TALKBACK CONTROL UNIT

INSTRUCTION MANUAL. Sensoray Model 720RB/DIN. Relay I/O Board (Rev A) October 12, 2001

M82xxD Fiber Optic RS-232 MicroModem Technical Manual

Model Number: DZ300-12EU

VIP-812A DUAL NETWORKED STATION PORT

Model (DRS-54V) Ver. 2.0 August. Dongah Rectifier System Operating Manual

Owner s Manual. TSD-DCPDV DC Power Distribution with Fixed & Variable Outputs. TSD-DCPDV DC Power Distribution. AtlasSound.com

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

LINE VOLTAGE TESTER CT101 USER S MANUAL. Please read this manual carefully and thoroughly before using this product.

Installation & Operation Guide

R & D SPECIALTIES SERIES 100 RO CONTROLLER USERS MANUAL. 2004, by R & D Specialties, Inc. All Rights Reserved.

Hybrid AC Driver [GCNC-1110]

PMDX Axis Breakout/Motherboard for Gecko Stepper Motor Drivers User s Manual

FVT/FVR20D2I1C4E INSTALLATION AND OPERATION MANUAL

T-Monitor E-Monitor TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...3 SECTION 3 - INSTALLATION...5

VIP-804 QUAD ENHANCED NETWORK AUDIO PORT

DCM Digital Control Modules

REDUNDANT POWER SUPPLY SYSTEM FOR NETGEAR RPS CAPABLE ETHERNET SWITCHES

CA-A480-A Elevator Controller. Reference & Installation Manual

PMDX-105 Quad Isolator Board

VE8014A/VE8014AR QUAD NETWORKED STATION PORT

Owner s Manual. TSD-DCPDV DC Power Distribution with Fixed & Variable Outputs. TSD-DCPDV DC Power Distribution. AtlasIED.com

FDCCM1-MM-L & FDCCM1-MM-R

Innovative Circuit Technology Ltd.

INSTALLATION & OPERATING INSTRUCTIONS

Chassis Power Supplies

LVN5200A-R2, rev. 1, Hardware Installation Guide

SVP48 SURGE VOLTAGE PROTECTOR INSTRUCTION MANUAL

500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System

Universal Switch Panel USP-KEYSERVER. User Manual

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions

Intelligent Channel Bank Shelf

SECURE/NONSECURE LED SIGN USER MANUAL

AEXX-349 SERIES REMOTE DISPLAYS

Zonit μats TM Users Guide μats1-lv Version 1.2

Transcription:

Instruction Manual Model 1582-45L Data Switch September 2010, Rev A REMOTE LOCAL SWITCH STATUS SELECT REMOTE LOCAL LOCAL SELECT CHANNEL SELECT POWER MODEL 1582 SWITCH CROSS TECHNOLOGIES, INC. Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., but may be reproduced or duplicated without the prior permission of Cross Technologies, Inc. for purposes of operating the equipment. Printed in USA. When ordering parts from Cross Technologies, Inc., be sure to include the equipment model number, equipment serial number, and a description of the part. CROSS TECHNOLOGIES, INC. 6170 Shiloh Road Alpharetta, Georgia 30005 (770) 886-8005 FAX (770) 886-7964 Toll Free 888-900-5588 WEB: www.crosstechnologies.com E-MAIL: info@crosstechnologies.com

INSTRUCTION MANUAL MODEL 1582-45L SWITCH TABLE OF CONTENTS PAGE Warranty 2 1.0 General 3 1.1 Equipment Description 3 1.2 Technical Characteristics 4 2.0 Installation 5 2.1 Mechanical 5 2.2 Rear Panel Signals 6 2.3 Front Panel Controls, Indicators 7 2.4 Operation 7 3.0 Environmental Use Information 9 WARRANTY - The following warranty applies to all Cross Technologies, Inc. products. All Cross Technologies, Inc. products are warranted against defective materials and workmanship for a period of one year after shipment to customer. Cross Technologies, Inc. s obligation under this warranty is limited to repairing or, at Cross Technologies, Inc. s option, replacing parts, subassemblies, or entire assemblies. Cross Technologies, Inc. shall not be liable for any special, indirect, or consequential damages. This warranty does not cover parts or equipment which have been subject to misuse, negligence, or accident by the customer during use. All shipping costs for warranty repairs will be prepaid by the customer. There are not other warranties, express or implied, except as stated herein. CROSS TECHNOLOGIES, INC. 6170 Shiloh Road Alpharetta, Georgia 30005 (770) 886-8005 FAX (770) 886-7964 Toll Free 888-900-5588 WEB: www.crosstechnologies.com E-MAIL: info@crosstechnologies.com 1582-45L Manual_Rev.A Page 2 09/21/10

MODEL 1582-45L Switch 1.0 General 1.1 Equipment Description - The 1582-45L provides remote or local latched relay switching between CH1, CH2, CH3 and CH4 data signals. The maximum data rate is 1 Mbps on the clock and data lines (8 lines) and up to 56 kbps on all other lines. Remote selection of CH1 to CH4 is by a contact closure to ground of the corresponding selection pin when the SELECT switch on the front panel is set to REMOTE. Local Selection of CH1 to CH4 is by push button switches on the front panel when the SELECT switch on the front panel is set to LOCAL. When in LOCAL operation all remote commands will be disabled, and when in REMOTE operation all the push buttons on the front panel will be disabled. On power loss the selected channel remains on. LEDs and contact closures to ground indicate the channels selected and REMOTE or LOCAL operation. The 1582-45L Switch is housed in a 1 3/4 X 19 X 12 deep rack mount chassis. SWITCH REMOTE LOCAL STATUS SELECT REMOTE LOCAL LOCAL SELECT CHANNEL SELECT POWER MODEL 1582 SWITCH CROSS TECHNOLOGIES, INC. FRONT AC IN J4 - DATA 4 J2 - DATA 2 GND J6 - CONTROLS/INDICATORS 1 14 J3 - DATA 3 J5 - DATA SWITCHED J1 - DATA 1 REAR FIGURE 1.1 Model 1582-45L Front and Rear Panels SWITCHED DATA 25 25 25 25 25 DATA 1 DATA 2 DATA 3 DATA 4 1 2 3 4 REMOTE SELECT CONTROL LOGIC 1 2 3 4 CH SELECT INDICATOR REMOTE/LOCAL INDICATOR 1582-45L Switch Block Diagram REMOTE LOCAL FIGURE 1.2 Model 1582-45L Block Diagram 1582-45L Manual_Rev.A Page 3 09/21/10

1.2 Technical Characteristics TABLE 1.1 1582-45L Switch Specifications* Data Characteristics Input/Output RS422 or RS232 Data Rate, max. 1 Mbps on clock and data lines up to 56 kbps on other lines Pins Switched All 25 Switch Characteristics Type Data Direction Isolation Switch time Contact resistance Configuration Controls and Indicators LOCAL/REMOTE Switch LOCAL CH Select LEDs Other Connector, Alarm/Control Connectors, Data Mechanical Power Latching Relay Both ways, non-blocking 40 db, min. 10 milliseconds, max. 10 max., < 1 typ. 25P4T Slide switch selects between LOCAL and REMOTE operation Push button switches locally select CH1, CH2, CH3, or CH4 CH1, CH2, CH3, CH4 ON-LINE; POWER; LOCAL; REMOTE Barrier Strip DB25, female 19 inch standard chassis 1.75 high X 12 deep Single AC Power Supply; 100-240 ±10% VAC, 47-63 Hz, 30 W *+10 to +40 degrees C; Specifications subject to change without notice 1582-45L Manual_Rev.A Page 4 09/21/10

2.0 Installation 2.1 Mechanical - The 1582-45L consists of one printed circuit board (PCB) housed in a 1 RU (1 3/4 inch high) by 12 inch deep chassis. A single power supply provides +5V and +15V DC power to the PCB. Connectors are DB25, female for the data connections and a barrier strip for the controls/indicators. The 1582-45L can be secured to a rack using the 4 holes on the front panel. Figure 2.1.shows how the 1582-45L is assembled. J6 connects DC Power to the PCB as shown and J2 and J4 are connected to the rear panel DB25 connectors via a ribbon cable. PCB J2 - Connected with ribbon cable to Rear Panel Mounted DB25 female connector. 14 26 1 13 J4 - Connected with ribbon cable to Rear Panel Mounted DB25 female connector. 14 26 1 13 PIN6 +15V PIN5 +5V PIN4 +5V PIN3 GND PIN2 GND PIN1 NC J7 1 POWER SUPPLY FIGURE 2.1 1582-45L Mechanical Assembly 1582-45L Manual_Rev.A Page 5 09/21/10

2.2 Rear Panel Signals - The input/output and control/indicator connectors located on the rear panel are shown in Figure 2.2. In order to select CH1 to CH4 remotely, switch SW5 on the front panel must be set to REMOTE operation. With SW5 set to REMOTE operation, the local push button switches on the front panel will be disabled. AC1 - POWER IN AC input for single power supply (90-260 VAC). J6 - CONTROLS/INDICATORS Contains REMOTE SELECT signals, CH1 to CH4 indicator signals and LOCAL and REMOTE indicator signals J1 to J4 - DATA 1 to 4 CH1 to CH4 data from which J5 (DATA SWITCHED) is switched between; DB25, female connector. AC IN GND J4 - DATA 4 J2 - DATA 2 J6 - CONTROLS/INDICATORS 1 14 J3 - DATA 3 J5 - DATA SWITCHED J1 - DATA 1 FIGURE 2.2 1582-45L Rear Panel Signals J5 - DATA SWITCHED The data switched will be from (or to)either CH1, CH2, CH3, or CH4; DB25, female connector. 13 12 11 10 9 8 7 6 5 4 3 2 1 25 24 23 22 21 20 19 18 17 16 15 14 FIGURE 2.3 DB25, Female Connector Pinout TABLE 2.1 J1,J2,J3,J4,J5 Pinout (Data, DB25 - Figure 2.3) Function Pin # Description CLOCK/DATA 2,3,9,11,14,16,17,24 1 Mbps RS422 clock/data lines OTHER 1,4,5,6,7,8,10,12,13,15, 56 kbps data/other lines 18,19,20,21,22,23,25 TABLE 2.2 J6 Pinout (Controls and Indicators, Barrier Strip) Function Pin # Description CH1 SELECT 1 Closure to ground and switch SW5 set to REMOTE selects CH1 CH2 SELECT 3 Closure to ground and switch SW5 set to REMOTE selects CH2 CH3 SELECT 5 Closure to ground and switch SW5 set to REMOTE selects CH3 CH4 SELECT 7 Closure to ground and switch SW5 set to REMOTE selects CH4 CH1 ONLINE 9 *Relay closure to ground (<5 ) indicates CH1 is selected CH2 ONLINE 10 *Relay closure to ground (<5 ) indicates CH2 is selected CH3 ONLINE 11 *Relay closure to ground (<5 ) indicates CH3 is selected CH4 ONLINE 12 *Relay closure to ground (<5 ) indicates CH4 is selected LOCAL ALARM 13 **Open collector output (<5 ) to ground when in LOCAL operation REMOTE ALARM 14 **Open collector output (<5 ) to ground when in REMOTE operation GND 2,4,6,8 Ground *Max voltage able to be connected to this is +30VDC @ 100ma **Max voltage able to be connected to this is +20VDC @ 30ma 1582-45L Manual_Rev.A Page 6 09/21/10

2.3 Front Panel Controls and Indicators - Figure 2.4 shows the controls and indicators located on the front panel. When switch SW5 is set to REMOTE operation, the push button selection switches, SW1-SW4, on the front panel are disabled. When switch SW5 is set to LOCAL operation the push button switches, SW1-SW4, will be enabled and all remote control will be disabled. DS1 - REMOTE LED Lights yellow when in Remote Select mode. DS2 - LOCAL LED Lights red when in Local Select mode. SW1 to SW4 - LOCAL SELECT Push button switches locally select the desired data channel (CH1 to CH4). REMOTE LOCAL SWITCH STATUS MODEL 1582 SWITCH 1 2 3 4 1 2 3 4 SELECT REMOTE LOCAL LOCAL SELECT CHANNEL SELECTED POWER SW5 - REMOTE/LOCAL SWITCH Switches between Remote and Local selection. DS4 to DS7 - CHANNEL LED Lights green when CH1 to CH4 are selected, respectively. DS3 - POWER LED Lights green when DC power is applied to the unit. FIGURE 2.4 1582-45L Front Panel Controls and Indicators 2.4 Operation 2.4.1 Installing and Operating the 1582-45L 1.) Install the 1582-45L in the equipment rack. 2.) Connect data to the DB25 DATA connectors, J1 - J5 (Figure 2.2). 3.) Connect to signals on the CONTROLS/INDICATORS connector, J6, as desired (Figure 2.2). 4.) Connect 100-240 ±10% VAC, 47-63 Hz to AC IN on the back panel (Figure 2.2). 5.) Be sure the POWER LED, DS3, is on (Figure 2.4). 6.) Set SW5 for REMOTE or LOCAL operation (Figure 2.4). 7.) Choose the desired data path either remotely (J6, Figure 2.2) or locally using the push buttons (SW1 - SW4, Figure 2.4) and check for proper data flow and that the appropriate CHANNEL LED (DS4 - DS7, Figure 2.4) is lit. 8.) AC Fuse - The fuse is a 5 mm X 20 mm, 2 amp slow blow (Type T) and is inserted in the far slot in the drawer below the AC input as shown in Figure 2.5. There is a spare fuse in the near slot. If a fuse continues to open, the power supply is most likely defective. 1582-45L Manual_Rev.A Page 7 09/21/10

FUSE DRAWER SPARE FUSE DRAWER AC Fuse - 2 amp slow blow (Type T), 5 mm X 20 mm ~ INPUT 100-240± 10%VAC 47-63 Hz 2A MAX FUSE TYPE T 2A GDC 250 VOLT FOR 100-240 V~ FIGURE 2.5 Fuse Location and Spare Fuse 1582-45L Manual_Rev.A Page 8 09/21/10

3.0 Environmental Use Information A. Rack-Mounting - To mount this equipment in a rack, please refer to the installation instructions located in the user manual furnished by the manufacturer of your equipment rack. B. Mechanical Loading - Mounting of equipment in a rack should be such that a hazardous condition does not exist due to uneven weight distribution. C. Elevated Operating Ambient Temperature - If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack may be greater than room ambient temperature. Therefore, consideration should be given to Tmra. D. Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised. Additional space between unit may be required. E. Circuit Overloading - Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of circuits could have on over current protection and supply wiring. Appropriate consideration of equipment name plate rating should be used when addressing this concern. F. Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connection to the Branch (use of power strips). G. Top Cover - There are no serviceable parts inside the product so, the Top Cover should not be removed. If the Top Cover is removed the ground strap and associated screw MUST BE REINSTALLED prior to Top Cover screw replacement. FAILURE TO DO this may cause INGRESS and/or EGRESS emission problems. 1582-45L Manual_Rev.A Page 9 09/21/10

CROSS TECHNOLOGIES, INC. 6170 Shiloh Road Alpharetta, Georgia 30005 (770) 886-8005 FAX (770) 886-7964 Toll Free 888-900-5588 WEB: www.crosstechnologies.com E-MAIL: info@crosstechnologies.com Printed in USA 1582-45L Manual_Rev.A Page 10 09/21/10