SECURA KEY CARD ACCESS CONFIGURATION GUIDE Multi-Reader Systems with NOVA.16 (SK-MRCP) 16-Door Panel

Similar documents
SK-ACPE User/Installation Manual

TERMS AND CONDITIONS PRODUCT GUIDE WITH LIST PRICING. Smart. Reliable. Secure.

TERMS AND CONDITIONS PRODUCT GUIDE WITH LIST PRICING. FOR ORDERS: FAX (818) TOLL-FREE (877)

Quick Start Installation Guide

UC-2000 Installation Manual Unicorn Computers Technology Limited

Two Door Controller GEN-045

Suprex RS-485 SPX-7500 Wired Reader-Extender

C5S120 Installation and Connection Guide

Installation Instructions. i-net Access Control Units. Part Code: IA-PCB IA-ACB IA-ACU IA-KIT

CRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09

TERMS AND CONDITIONS PRODUCT GUIDE WITH LIST PRICING. FOR ORDERS: FAX (818) TOLL-FREE (877)

genesis TECHNICAL MANUAL Two-Door Controller GEN-045

Quick Start Installation Guide

System Galaxy Hardware Manual

6222 Two Door Module Technical Operations Manual

TAC I/NETTM 1284, 1280, Security Control Unit

Quick Installation Manual

ENTRACOMP 28SA Plus. User/Installation Manual

Installation Guide. Avigilon ACM Embedded Controller

TB21. NO - Relay. Relay. Common - Relay. NC - Relay. Input J23. Ground TB22 TB23. NO - Relay Common - Relay NC - Relay Input Ground.

Amano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL

DESIGN GUIDE FOR INFINITY SYSTEMS

Symmetry M2100 Controller

Access Control System

721EX Access Controller Installation

MTGW. Installation Guide. CAN-RS-485 BUS Gateway

PRO3200 Professional Modular Access Control Hardware

Suprex RF Series CYPRESS. Operations Manual. Suprex Reader Extender - RF Wireless Interface EXP SPX Mhz SPX-5521_MAN_0316

NXT-1R/-3R/-5R Exit Reader Installation Drawing 4-Conductor - OR - CAT-5 Cabling. IO-Plus (Green) Ground (Black) +12 VDC (Red) Shield (Silver)

WRI400 WIRELESS READER INTERFACE

Code Dynamics, Inc. Port Splitter

Cluster Controller. Impro (CCM) Cluster Controller Module INSTALLATION MANUAL

MS-3000 MicroStar Reader

VertX. V100, V200 and V300. Installation Guide Barranca Parkway Irvine, CA USA. November Rev A.1

PIB300 and PIB301 User Guide. Installation and operation instructions for Panel Interface Board

CYPRESS " " EXP SPX Expansion interface! modules EXP-2000_MAN_0314

Cardax FT Controller 3000

Installation Instructions for UL Rev A

SmartLock Controller INSTALLATION MANUAL

SPX-5000 Series. Operations Manual. Suprex Reader Extender - RF Wireless Interface. RPT GHz Repeater. SPX GHz

Wiring Guide. EP.NMiNi 2. Version 1.04 Last Updated:

Connecting a Cisco Output Module

Micro Engine Biometric Reader

Access Easy Control System. Reference Guide

PRO2200 Professional Modular Access Control Hardware

Thursday, May 29,

MS-7000: SuperStar Reader

SolarVu Installation Guide For CSI-KTL-GS Three Phase Inverters

Single-Door + Multi-Function

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

This network (Figure 5) has a Panel-Version Facilitator, Operator Terminal, five controllers, and a repeater.

Windows-Based Terminal. TK-3550 H.W. Manual

The Future of Proximity Access Control

EA500. Installation Instructions Transponder

NetGen Hardware Installation Guide. for NetGen Ethernet Door Controllers

ACTpro Single Door IP Controller. Operating & Installation Instructions

Bewator Granta Controller Installation Handbook

Brivo Access Control System (ACS) Installation Manual DOCUMENT NUMBER ENG-DOC-003 ACS5000-E ENG-WI-001

BioPointe Reader Installation Guide

1. FEATURES AND BENEFITS

DATA LOGGER GEOLOGGER G8 PLUS

STANLEY MANUFACTURED ACCESS CONTROL ACCESS STARTER KIT EASY-TO-USE AND HIGHLY RELIABLE ACCESS CONTROL

Canlan INSTALLATION MANUAL

CCN-to-Ethernet Converter Installation Instructions

BACnet Flow Controller for Fan Filter Units

Click Save to return to the main Setup screen.

This is Cansec s 25th anniversary. Many of

ACS5000 Panel (A/E/S) Installation Manual

Connecting a Cisco Input Module

SmartLock Pro INSTALLATION MANUAL

PW6000 Modular Access Control System PW6000 Intelligent Controllers and Modules

AccessPlus VOICE and/or DATA CELLULAR SYSTEM

MegaTrak MCU-9000 Harness Wiring

SPX-7200 Series SPX-7200 EXP Operations Manual. Suprex Reader Extender - Ethernet SPX-7200_MAN_082112

Rev Cutler-Hammer Smart Breaker Panel Control Manual

SINGLE READER EXPANSION MODULE

ACCESS CONTROL STARTER KIT HARDWARE INSTALLATION GUIDE

NETAFIM WILL NOT ACCEPT RESPONSIBILITY FOR DAMAGE RESULTING FROM THE USE OF NETAFIM'S PRODUCTS OR THE USE OF THIS MANUAL.

Installation Instructions

Accessories IC690ACC900

PXL-250 Tiger Controller

VOICE and/or DATA CELLULAR SYSTEM

MS-5000: MiniStar Reader

Installation & Operation Guide

"PC" Central Access Control System

INSOMNIAC CIA G-600 Gateway Installation Manual P/N CIA Revision 1.0 Date Code:

OMX-CI-RS232 Control Interface

Installation Instructions for the AUTOcard-SA System

N-1000-II. Installation & Programming Manual. Version rev. 2.0

Quick Start Guide. SEB-710 I/O Expansion board. Introduction

Brivo ACS6000 (A/E/F/S) Installation Manual

PR602LCD v1.0 Installer Manual Rev. A

GRAVIMETRIC GATEWAY PRE-SALES SUPPORT DOCUMENT. December 3, Computer Communications

Installation Instructions (KF-2000)

istar Pro Installation Guide

SALLIS. Installation & Maintenance Guide. Issue: /07/03. Author: Jon Mendizabal

Select a Data Communication Interface

Displayport, as shown, has 20 pins and can be used for audio, video, or both audio and video transmission.

WAC-IPMG200 IP Based Access Control System

Overview of the Cisco Wireless Gateway for LoRaWAN

Transcription:

SECURA KEY CARD ACCESS CONFIGURATION GUIDE Multi-Reader Systems with (SK-MRCP) -Door Panel WITH RS- GATEWAY CONNECTED DIRECTLY TO A PC RS- GATEWAY POWER: EIGHT (8) SMART READERS EVENLY SPACED UP TO 000 FT. WITH 8/ * DATA: UP TO 4000 FT. TOTAL WITH CAT 5. 5e OR SK- DB9 SK-PLUG9 RS- UP TO 00 Ft.... WITH RS- TO RS-485 CONVERTER () RS-RS485 CONVERTER PLUG INTO SK- POWER: EIGHT (8) SMART READERS EVENLY SPACED UP TO 000 FT. WITH 8/ * DATA: UP TO 4000 FT. TOTAL WITH CAT 5. 5e OR UP TO 4,000 Ft. SK- RS-485... * HAS TWO SEPARATELY FUSED 4VDC POWER OUTPUTS - EACH HANDLES MULTIPLE READERS WITH SINGLE LOCATION RS- CONNECTION SK- DB9 SK-PLUG9 STAR / DAISY CHAIN / MULTIDROP FANOUT T CONFIG RS-485 communications. Suggested cable: CAT 5 cable or Two Twisted Pair. Total system cable length: 4,000 ft. STUBBED RS- communications. Suggested cable: -Conductor, NOTE: Shielded, with no twisted pairs. PC or serial printer. Total Each SK-MRCP above can support cable length 00 feet. SK- may be required if your Smart readers. PC does not have a COM port. Page

(SK-MRCP) MULTI LOCATION SYSTEM WITH SK-NET-MLD SOFTWARE RS- GATEWAY SK- SK- MODEM TELCO LINE MODEM SK-MDM Up to s A virtually unlimited number of remote locations can be set-up on one PC with SK-NET-MLD Software. Up to s Network Wiring Connections Line B () J Line A () DC SIGNAL GROUND () (REQUIRED) Earth Grounded Shield is highly recommended in environments subject to high voltage electrical discharge (i.e. lightning). Shield should be connected to earth ground only at one end of the cable. DC Signal ground is required. DC Ground wire is NOT to be connected to earth ground. Earth Grounded Shield is highly recommended in environments subject to high voltage electrical discharge (i.e. lightning). Shield should be connected to earth ground only at one end of the cable. DC Signal ground is required. DC Ground wire is NOT to be connected to earth ground. SINGLE LOCATION RS-485 with CONVERTER RS-RS485 CONVERTER PLUG INTO SK- SK- RS-485 communications. Suggested cable: CAT 5 cable or Two Twisted Pair. Total system cable length: 4,000 ft. RS- communications. Suggested cable: -Conductor, Shielded, with no twisted pairs. PC or serial printer. Total cable length 00 feet. SK- may be required if your PC does not have a COM port. Note: When using the RS- to RS-485 converter, you cannot use the stubbed, star fanout or T configuration. All network connections from SK-MRCP to the next SK-MRCP must be in parallel with each other. The J connector, Pins and must be a twisted pair. Pin (Ground) uses a conductor from another pair, if you are using CAT 5 or CAT cable. Page

(SK-MRCP) SYSTEM USING SK-NET-MLD SOFTWARE WITH MULTIPLE LAN CONNECTIONS ROUTER/SWITCH HUB WIRED/WIRELESS ROUTER WITH OPTIONAL SK-WLSE MOD* ETHERNET CABLE: (Required cables CAT 5e or CAT ). Wired: max distance 00 (00m) between devices. Wireless: Typically 00-00 (0-0m) depending on interference, building structure and metal objects. NOTE: Each SK-MRCP above can support Smart Readers. * Call Factory for availability. SINGLE LOCATION WITH LAN CONNECTION NOTE: SK-NET-MLD software must be used when connecting more than one SK-MRCP to the LAN. This can also be a remote location connected over a WAN, if a static IP address is used at each remote site. NETWORK STAR / T CONFIG DAISY CHAIN / MULTIDROP FANOUT RS-485 communications. Suggested cable: CAT 5 cable or Two Twisted Pair. Total system cable length: 4,000 ft. STUBBED RS- communications. Suggested cable: -Conductor, Shielded, with no twisted pairs. PC or serial printer. Total cable length 00 feet. ETHERNET CABLE: Standard Ethernet cable connector connected to existing LAN. NOTE: Each SK-MRCP above can support smart readers. Page

SYSTEM equipment components ACCESS CONTROL UNIT: (SK-MRCP): -Door Access Control Unit with Ethernet connector Radio Key Low Frequency Proximity READERS - Proximity Smart Reader ( per SK-MRCP) RKDT-SR-M (Mullion Style Reader) RKDT-SR-S (Switchplate Style Reader) CARDS/TAGS: RKCM-0- RKKT-0- RKCI-0- Molded Proximity Cards - / bit encoding Key Tags - / bit encoding ISO Proximity Cards - / bit encoding E*Tag High Frequency Proximity: READERS -Contactless Smart Readers ( per SK-MRCP) ET8-SR-X-M (Mullion Style Reader) ET8-SR-X-D-W, or ET8-SR-X-D-I (Switchplate/ Decora Style Reader, white or ivory) CARDS/TAGS: ETCI04-- ISO Card- / bit encoding ETCI04-4- ISO Card- / bit encoding, Mag-Stripe ETST0--Key Tag Trapezoidal - / bit encoding ETKT0- Key Tag, Rounded End, / bit encoding SOFTWARE: SK-NET -DM - Basic Software - Flash Drive & Manual SK-NET -MLD - Multi-Location Software with Flash Drive and manual SK-NET-MLD - CSXX (XX=,5,0 or 5 workstations) Flash Drive and Manual with Client Server License PC REQUIREMENTS: See Table OPERATING SYSTEM MINIMUM REQUIREMENTS* PROCESSOR SPEED RAM AVAILABLE DISK SPACE WINDOWS XP OR GHz GB GB NEWER * For larger installation more disk space may be required. RECOMMENDED SYSTEM WINDOWS XP OR GHz GB 0 GB NEWER * For larger installation more disk space may be required. SERVER REQUIREMENT (FOR CLIENT/SERVER VERSIONS)** WINDOWS 00 GHz GB GB OR NEWER ** For SK-NET-MLD-C/S version, a server is required to install ADS and the database. SK-NET must be installed on a workstation only. Required Peripherals: RS- COM Port, Port or TCP/IP, a modem if you use dial-up and a printer for reports. ACCESSORIES: - RS- to RS-485 Converter with Power Supply (plug into SK-) RELAY BOARDS ELK-94 Sensitive Relay, Altronix RBSN or RBSNTTL Relay Modules (Contact your dist.) RS-E - Connects J MTA connector to DB9 SK-4VDC - DC power supply, provides A@4VDC. SK-SR - SecuRelay Intelligent Relay Module SK-MDM - Modem - 5K Baud External Modem for dial-up connection to any SK-MRCP with MLD software SK-ACP-PS - A, 4VDC 4.0 AH supply and stand by battery for SK-MRCP. SK-BAT - 4.0 AH standby battery for SK-MRCP. SK-PLUG9 - Computer connector (DB9) with wire pigtail. SK- - Converts Port at PC to serial COM Port with DB9 connector SK-WIO- - One-door Wiegand Reader Interface, Connects to RS-485 Peripheral Bus SK-WLSE-MOD* - Wireless LAN adapter, 80. b/g. Powered by SK-MRCP. Connect at J and set jumpers. SK-XFRMR -.5VAC 40VA Transformer for SK-MRCP. * Contact Factory for Availability. Page 4

SECURA KEY sk-mrcp Typical Door Installation INPUT TO PC HOST, 4, 5 DOOR MONITOR INPUT REMOTE DOOR- OPEN SWITCH SMART READER PERIPHERAL BUS L A T C H ELECTRIC STRIKE or MAG LOCK POWER STRIKE OR MAGLOCK SUPPLY CABLE TYPES: RS485 PERIPHERIAL BUS (TO ADDITIONAL SMART COND, -8 AWG READERS) COND, SHIELDED 8-4 AWG RS-485 - CAT 5 NETWORK CABLE OR TWO TWISTED PAIR 4 TCP/IP - CAT 5e OR CAT ETHERNET CABLE 5 RS-5 or CONDUCTOR, SHIELDED, NON-TWISTED DATA & READER POWER CABLE: - CAT 5 (RS-485) + 8/ (reader Power) - Coleman 9795-0- CAT5 + 8/ siamese cable 7995 Page 5 www.securakeystore.com (800) 878-789 sales@securakeystore.com