Quality of Semiconductor Raw Materials: Evolution and Challenges. Yongqiang Lu Kevin McLaughlin

Similar documents
Supporting Information. Highly Selective and Reversible Chemosensor for Pd 2+ Detected by Fluorescence, Colorimetry and Test Paper.

ENDF/B-VII.1 versus ENDFB/-VII.0: What s Different?

ICP-OES. By: Dr. Sarhan A. Salman

ISO INTERNATIONAL STANDARD. Water quality Digestion for the determination of selected elements in water Part 2: Nitric acid digestion

New Generation Explorer Handheld XRF. EXPLORER 7000 Mineral Ore Analyzer

Row 1 This is data This is data

Row 1 This is data This is data. This is data out of p This is bold data p This is bold data out of p This is normal data after br H3 in a table

Activity concentration for exempt material (Bq/g)

Applications of DSA for lithography

Thermo Scientific Niton XL2 GOLDD Series Environmental Analyzers Elemental Limits of Detection in SiO 2

The Pyramid Table. The Four Matrices; Top Level, Matrix; x = 1. Matrix; x = 2

Waleed Pervaiz CSE 352

VI... VIII

So il Geochem ica l Ba seline and Env ironm en ta l Background Va lues of Agr icultura l Reg ion s in Zhejiang Prov ince.

Frontiers in CD-SEM metrology

G450C Briefing and Supply Chain Collaboration on 450mm Transition. SEMI Northeast Forum Sept. 11,2013

MONITORING THE REPEATABILITY AND REPRODUCIBILTY OF A NATURAL GAS CALIBRATION FACILITY

TEST REPORT : SCENTCO LIMITED. : China : USA, EU, ASIA. : 16-May EN71 Part 3:2013 Migration of Certain Elements Pass

XRF for Regulatory Programs RoHS and Consumer Safety Compliance

LA ICP MS Analysis with

Overview INTELLIGEN ULV DISPENSE SYSTEM. Advanced two-stage system enabling superior dispense and filtration of ultra-low viscosity fluids

Challenges in Manufacturing of optical and EUV Photomasks Martin Sczyrba

Lockheed Martin Nanosystems

Improvements in LA-ICP-MS for Trace Forensic Analysis of Common Household Products Using a Short Pulse Ultraviolet Laser

IPR Äspö Hard Rock Laboratory. International Progress Report. TRUE Block Scale project. Summary of chemical data December 2002

MACHINE VISION FOR SMARTPHONES. Essential machine vision camera requirements to fulfill the needs of our society

CLEAN ROOM PROTOCOL AND WAFER HANDLING

800 W. 6 th Street, Austin, TX 78701

APPENDIX C. Chain of Custody Forms

MLI INTRODUCTION GUIDE. copyright reserved 2012 MLI

GEOPT19 - AN INTERNATIONAL PROFICIENCY TEST FOR ANALYTICAL GEOCHEMISTRY LABORATORIES REPORT ON ROUND 19 / July 2006 (Gabbro, MGR-N)

Key Considerations to Probe Cu Pillars in High Volume Production

Release Notes: Thermo-Calc Software Package Version 2018a

Why Quality Depends on Big Data

Metrology for Characterization of Wafer Thickness Uniformity During 3D-IC Processing. SEMATECH Workshop on 3D Interconnect Metrology

Medical Sealing Solutions

800 W. 6 th Street, Austin, TX 78701

GeoPT22 - MBL-1, Basalt

INCAGSR. Gun Shot Residue

DEFINITIVE ANNUAL REPORT Trace elements 2014

Flexible Organic LCD: From lab to fab to the next wave of products

Nanosight NS300 NBTC User Instructions

How to Extend 2D-TLC Endurance to 3,000 P/E Cycles

800 W. 6 th Street, Austin, TX 78701

IMPROVE XRF Analysis SOP 301, Version 2.1 TI 301F-Level I Validation of Monthly XRF data Date: Dec 14, 2015 Page 1 of 7.

VLSIresearch - Critical Subsystems and Components Service Overview

MECHANICAL CONTRACTORS ASSOCIATION OF AMERICA, INC. CLEANROOM PIPING AND PROCEDURES BASIC CONSIDERATIONS

High Value Manufacturing for Low Cost Electronics

FSMA Template Package List of Documents

ABRT Series Air-Bearing Direct-Drive Rotary Stage

NOTES on: An NJOY Processing Caution when Doppler Broadening

Globalization and its Impact on the Probing Process. Alan Romriell (Spansion) Manish Gulati (FormFactor)

Product / Process Change Notification

Sampling Approaches to Metrology in Semiconductor Manufacturing

ABRT Series Air-Bearing Direct-Drive Rotary Stage

Vision Based Metal Spectral Analysis using

HP environmental messaging

EM Sample Preparation Coating Technology. April 2013

SPS3 autosampler. Innovation with Integrity. For the Bruker 810/820-MS. Mass Spectrometry

Addressable Test Chip Technology for IC Design and Manufacturing. Dr. David Ouyang CEO, Semitronix Corporation Professor, Zhejiang University 2014/03

Cleanroom Design. Second Edition W. WHYTE. JOHN WILEY& SONS Chichester New York Weinheim Brisbane Singapore Toronto. Edited by

Bringing 3D Integration to Packaging Mainstream

Overlay control methodology comparison: field-by-field and high-order methods

Drill-down Analysis with Equipment Health Monitoring

EEMI450 and global 450mm Cooperation

TEST REPORT. The following test item(s) was/were performed on submitted sample(s) and/or component(s) confirmed by applicant.

Thin n-in-p planar pixel modules for the ATLAS upgrade at HL-LHC

Experiences from CRYRING diagnostics

High Value Manufacturing for Low Cost Electronics

Flatness Compensation Updates/Challenges

Joint Research with imec Belgium Targeting Measurement for 10-nm Generation

Design of Experiment Application for Unit Process Development in Semiconductor Manufacturing

Optimizing Pharmaceutical Production Processes Using Quality by Design Methods

Highly Parallel Wafer Level Reliability Systems with PXI SMUs

LECTURE 15. Dr. Teresa D. Golden University of North Texas Department of Chemistry

FST s status on EUV Pellicle & Inspection System Development

Case Study Core Capabilities in Nuclear Forensics

Lecture 4a. CMOS Fabrication, Layout and Simulation. R. Saleh Dept. of ECE University of British Columbia

GEOPT10 - AN INTERNATIONAL PROFICIENCY TEST FOR ANALYTICAL GEOCHEMISTRY LABORATORIES - REPORT ON ROUND 10 / December 2001 (CH-1 marine sediment).

Flexar FX-20 LC Pump: Ultimate Performance and Flexibility for UHPLC and HPLC

A Fast Estimation of SRAM Failure Rate Using Probability Collectives

HOW TO SELECT A CLEANROOM: MODULAR CLEANROOMS FOR NEW BUSINESSES, NEW PRODUCT DEVELOPMENT

Designing Next Generation Test Systems An In-Depth Developers Guide

Software and computing evolution: the HL-LHC challenge. Simone Campana, CERN

300 mm semi-/fully-automated probe system

TEST REPORT MATERIAL SUBMITTED IMPORTER COMPANY MODEL NO SUPPLIER REFERENCE BUYER : : : :

ANZTB 2010 Conference. Tuesday, 2 nd March 2010 Hybrid Keyword Data Driven. Frameworks by Jonathon Wright. Introduction ANZTB

Cosmetics. Density, Refractive Index, ph and Color Multiparameter Analysis

Electronics and Optoelectronics

TEST REPORT : SCENTCO LIMITED. : China : USA, EU, ASIA. : Not Present. : 16-May : 19-Jun-2014

Press release. High-purity positioning systems for demanding applications. Assembly in Schneeberger's cleanroom

Shielding factors for traditional safety glasses

Energy Saving in Cleanrooms

ISMI Industry Productivity Driver

11607 E 43 rd Street North Tulsa, Oklahoma T F E edge.com

Clean Manufacturing Conception & Realisation

REGULATORY COMPLIANCE. Each device complies with the EMC Directive 2004/108/EC and is CE marked

3D SYSTEM INTEGRATION TECHNOLOGY CHOICES AND CHALLENGE ERIC BEYNE, ANTONIO LA MANNA

Free-Free, Fixed or Other Test Boundary Conditions for the Best Modal Test?

A Case for Custom Power Management ASIC

Transcription:

Quality of Semiconductor Raw Materials: Evolution and Challenges Yongqiang Lu Kevin McLaughlin

Outline Advance of Fab technologies and the evolution of raw materials for ever higher quality Challenges: metrology Case study--icp MS Case study particle measurement Challenges: supply chain Case study-supply chain Challenges: cost Summary 2 External use

25% TMAH Quality Roadmap 32 45 nm 22 28 nm Current Metrology Limits 14 16 nm 10 7 nm 5 3 nm Current Metrology Limits 9 External use

Metal and particle metrologies have been pushed to their limits and lag behind the requirement Metals: detection limit to the single ppt or below Challenges of Metrology Reality: 1~10 ppt especially in difficult matrix like TMAH GR&R in the 30% or worse Particles: <20 nm in liquids Reality: 30nm Nano/micro bubbles causing issues Contamination from every thing in contact with the products packaging, tubing, even the instrument used to measure the samples No material is clean including DIW, PTFE etc In the field of Uncertainty Principle applies

ppt Case Study ICPMS # "metal ions" in 40 nl/s 1000 43,000 100 4,300 10 430 1 43 0.1 4 At 10 ppt or less, only a few hundred metal ions reach ICPMS detector per second, measurement error increase significantly At 0.1 ppt, one metal ion from any where will contribute 25% of the measurement

Case study ICPMS Monte Carlo Simulation Using Poisson distribution model and process parameters Assume a true 10 ppt sample Simulation Result: Average 11.5 ppt, Distribution shift to the right (high) side due to contaminations events If the spec is 11.5, there will be 50% chance for the true 10 ppt sample to be measured out of spec Due to uncertainty, significantly more measurement needed to detect small difference Supplier and customer measurement correlation and lab collaboration absolutely key

Metrology: Metals Ag 15 ppt K 50 ppt Al 15 ppt Li 50 ppt As 50 ppt Mg 25 ppt Au 50 ppt Mn 15 ppt B 300 ppt Mo 50 ppt Ba 50 ppt Na 50 ppt Be 50 ppt Ni 15 ppt Ca 100 ppt Pb 50 ppt Cd 50 ppt Rb 50 ppt Co 15 ppt Sn 50 ppt Cr 15 ppt Sr 50 ppt Cs 50 ppt Ta 50 ppt Cu 25 ppt Ti 50 ppt Fe 10 ppt Tl 50 ppt Ga 50 ppt V 50 ppt Hg 50 ppt W 50 ppt Ir 15 ppt Zn 25 ppt 11 External use Number of required metals continues to increase Increases likelihood of OOC event Metals levels as low as 10ppt require ICP-MS detection limits at 1ppt Extremely difficult to achieve in 25% TMAH matrix Current metrology limits closer to 10ppt Metrology method development required for each metal measured

Case Study LPC Particle Measurement Two different filtration systems LPC counted about the same for 2 samples ~300@0.03um Need LPC to be able to count lower than the current 30nm to 20 or even 10nm Huge difference on wafer particle count @ 20nm

Supply Chain

Supply Chain Challenges I Supplier, sub-supplier management Petrochemical-based raw materials dirty Unmotivated suppliers not willing to clean their products for semi applications scale too small Management of Change moving upstream Better may not be good, changes always bad, need to be closely managed Bring sub-suppliers up to speed to Fab requirements Freezes supply chain much earlier in development, limiting options Quality roadmap outpacing metrology Controlling what you can t see Management of Change 6 External use

Supply Chain Challenges II Demands for local supply Challenges economies of scale Regional, local challenges Different registration requirements and processes China s pollution crackdown Product stewardship: Cradle to Grave has become Cradle to Cradle Minimize waste, waste disposal Waste composition (e.g. nitrogen content) Recycle 7 External use

Case Study --Supply Chain Minimizing Contaminations Manufacturing Metal-free raw materials Metal-free process flow Purification and filtration Bulk Delivery Metals <25 ppt Filtration @ 30-50 nm Facility Side Metals <25 ppt Filtration @ 30 nm Dilution/Chemical Distribution Metals <2.5 ppt Filtration @ 10-20 nm Tool Side Metals <2.5 ppt Filtration @ 2-5 nm 10 External use

Case Study --Product Packaging Effects Particle Count (#/ml) 5000 4500 4000 3500 3000 2500 2000 1500 1000 500 0 0.5 0.2 0.1 0.04 Particle Size (µm) As-produced As-delivered Packaging well-known to affect product quality Leaching of metals, organics Shedding of particles Effects increase exponentially with severity of purity specifications Sufficiently clean packages order of magnitude more expensive than packages historically used Reusable packages used in closedloop systems can meet purity requirements Customers generally require dedicated packaging return loops, greatly complicating logistics, inventory management 13 External use

Case Study O-Ring Metal Leaching Element Metal (ppt) OR1 Metal (ppt) OR2 Metal (ppt) OR3 B 234 222 < 200 Na 31 < 20 35 Mg 100 93 97 Al 171 194 169 K < 20 24 40 Ca < 20 < 20 25 Ti 22 < 20 < 20 Fe < 20 < 20 < 20 Co < 20 < 20 < 20 Ni < 20 < 20 21 Cu < 20 < 20 < 20 Zn 1548 < 20 < 20 As < 20 < 20 < 20 Sr < 20 < 20 < 20 Mo < 20 < 20 < 20 Ag < 20 < 20 < 20 Cd < 20 < 20 < 20 Sn < 20 181 < 20 Three different O- ring from 2 vendors Soaked in 25% TMAH for 6 hours OR1 Could be a source of Zn contamination

Product Fingerprinting Increasing requests for product fingerprinting to evaluate unknown unknowns Creates potential Intellectual Property concerns Raw material, manufacturing, and purification IP can be compromised through evaluation of fingerprinting data 14 External use

Cost Considerations Cost Trend of Raw Materials with Technology Nodes Challenges Raw materials cost increase exponentially to meet the low ppt level metals and 30 nm particles for nodes 14nm and beyond Increased PM, consumables, analytical Increase packaging and package handling Increase waste Shortened equipment lifetime Decreased process capacity etc New cleanroom or upgrade One Sigma rule (only accepting product within 1 sigma range) Will further increase the cost and waste Find the use for about 40% rejected Not encouraging reduce process variability

Summary Raw material suppliers face many critical challenges Metrology not currently meeting the demands, facing a lot of Uncertainty Much more complicated supply chain and processes Stiff cost increase Develop vigorous quality control mentality Working with customers, learning from customers, and serving the customers It s ALL about understanding and reducing variations Specs is only the bare minimum Stable performance of your products is the key Management of Change Not just for customers Process Change Notification, open communication with customers Transparency is key, needs to be a 2-way street; Supplier to customer, customer to supplier 15 External use

Acknowledgements: Dr. Dan Montville for his Monte Carlo simulation and valuable discussion for ICPMS analysis, Hidde van Assendelft for his Market related materials SACHEM kmclaughlin@sacheminc.com 512-421-4929 ylu@sacheminc.com 512-421-4978 17 External use