Technical Information Promonitor NRF560

Similar documents
Technical Information Prothermo NMT532

Prothermo NMT 532. Technical Information. Intrinsically safe multi-signal converter with precision average temperature sensor for inventory control

Technical Information RIA16

Operating Instructions and Description of Instrument Function Prothermo NMT539

Technical Information RIA15

Series 3730 Type Electropneumatic Positioner

Operating Instructions Soliswitch FTE20

Technical Information RIA16

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline

TFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5

Series 3730 Type Electropneumatic Positioner

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

4 â RIA251. Technical Information. Process display Digital loop powered display for ma current loops

Inventory Control Tank Side Monitor NRF 590

Dräger Polytron 8200 Stationary gas detector (CatEx)

WirelessHART Adapter SWA70

Assembly. max Example: 2-wire connection IH More connection types see section electrical connections. Auxiliary voltage.

Level measurement. Applications. Special features. Description

T EN TROVIS Electropneumatic Positioner

3/2 Directional control valves Direct solenoid operated poppet valves Internal thread G 1/2, 1/2 NPT or flanged with NAMUR interface

Safety Instructions Cerabar S PMP71, PMP75

4 â Active barrier RN221N with optional HART diagnosis. Technical Information

CombiTemp TFRN/TFRH. Operating instructions. Temperature sensor. Operating Instructions: EN.

Installation & Operation Manual

Safety switches with separate actuator

Operating pressure (bar) kv factor (m 3 /h) *3)

Series 3730 Electropneumatic Positioner Type

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

Series 3731 Electropneumatic Ex d Positioner Type with FOUNDATION TM Fieldbus communication

Special Documentation Soliphant M with electronic insert FEM57 + Nivotester FTL325P

INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069

Safety switches for hinged doors

Stratos Pro A4 PH. Connection

Installation & Operation Manual

Micro Motion Model 2200S 2-Wire Transmitter with MVD Technology

Level Measurement Continuous level measurement - Ultrasonic transmitters

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

Functional safety manual Liquiphant M/S with FEL58 and Nivotester FTL325N

21023, 21025, 2/2 Direct solenoid actuated poppet valves

Assembly. Function 41

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

Technical Data. General specifications. Rated operating distance s n 3 mm

Process display RIA 251. Digital loop powered display for ma current loops. Application areas. Plant and machine construction.

Supplementary Components WirelessHART products

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. WirelessHART components Gateway and accessories

General Specifications

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED

Grounding Monitoring Device Series 8485

Safety instructions. IECEx TUN Ex ia IIC T6 Gb

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

26360, Inline. Technical data. Ordering information See page 2. For connector plugs see page 2 and data sheets N/en /2 5/2.

Technical Information Tank Side Monitor NRF590

Series 3731 Type Electropneumatic Ex d Positioner with FOUNDATION TM fieldbus communication

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

Liquipoint T FTW 31, FTW 32 Level limit switch for multiple point detection in conductive liquids

Technical Information WirelessHART Adapter SWA70. Smart WirelessHART interface module with power supply for field devices. Products Solutions Services

Operating pressure. N/en/en

Series 3731 Type Electropneumatic Ex d Positioner with HART communication

PROFIBUS-PA Positioner Type 3785

UFD 5. Display for ALTOSONIC 5. Technical Datasheet. Configurable display for ALTOSONIC 5 Easy installation Durable design

Data Sheet T 8493 EN. Series 3793 TROVIS 3793 Electropneumatic Positioner with HART communication

26360, NAMUR. Technical data

Safety switches with manual mechanical delay and separate actuator

Minilog RDL10. Technical Information. Measured value collector with 2 input channels for storing analog and digital values

Series 3793 TROVIS SAFE 3793 Electropneumatic Positioner with HART communication

Series 3731 TROVIS SAFE Electropneumatic Ex d Positioner

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Operating pressure (bar)

Operating pressure. N/en/en

Connection of OXY module with oxygen sensor (SE 706, Mettler Toledo InPro 6800, Hamilton Oxyferm) Model used: Stratos Pro A401N OXY/ V AC/DC

97105 Inline 3/2, 5/2 & 5/3 way spool valves electromagnetic actuated, indirectly controlled G1/4, 1/4 NPT, G1/2, 1/2 NPT

T 9510 EN Media 7 Differential Pressure Meter with remote data transmission

Guided Wave Radar Level and Interface Transmitter

Safety switches with separate actuator

SCADAPack Modbus multivariable transmitter

VALVES Inline 3/2-, 5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT

4110 HART Level Encoder

Data Sheet T 8394 EN. Series 3725 Type 3725 Electropneumatic Positioner

Ethernet CPU Module & Power Module for Zone 1 / Div. 1 Series 9441/12 and 9444/12

ExCos-P Pressure sensor 20 Pa Pa

YT-870 / 875 Series. Rotork YTC Limited VERSION 1.06

Grounding Systems / Ground Monitoring Device Series 8146/5075 and 8125/5071

Flow Measurement SITRANS F M

95100, 2/2 (stainless steel) Direct solenoid actuated poppet valves

Linear Luminaire with LED Series 6012/5

General Specifications

ExBin-D Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh)

Spare Parts for RM71 SmartLine Guided Radar Level Meter

CURRENT TO PROFIBUS PA CONVERTER

D1093S INSTRUCTION MANUAL. D SIL 3 Relay Output Module with Line and Load diagnostics. DIN-Rail Model D1093S

General Specifications

System Components Surge Arrester HAW 261 and HAW 262

Termination Board FC-GPCS-RIO16-PF. Features. Assembly. Function. Connection USIO/UPIO 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Inductive sensor with analog output BI15-M30-LI-EXI

Series 95000, 2/2 Direct solenoid actuated poppet valve

Technical Information Tankside Monitor NRF81

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

Grounding Monitoring Device Series 8485

Transcription:

TI00462G/08/EN/03.14 71264171 Products Solutions Services Technical Information For tank side monitor and control of Proservo NMS5 intelligent tank gauge Application is a monitoring unit for use with Proservo series of tank gauges. Mounted at the tank side or up to 1200m (meters) away (local HART connection). NRF560 provides indication of measured level, temperature data and operating status, and can send operating commands to Proservo NMS5 from a convenient location. Features and Benefits Remote monitoring and control for NMS tank gauge Indication via two line illuminated display Operation via 3 optical keys (touch control) and Endress+Hauser user friendly Programming matrix Protection class IP 67 housing Explosion proof for hazardous area mounting

Table of Contents Important Document Information.....................3 Notes on Safety Conventions and Symbols................ 3 Function and System Design..........................4 System Design........................................ 4 Input and Auxiliary Energy.......................... 5 Measured Variables.................................... 5 Communication....................................... 5 NRF560 Terminals.................................... 5 Overvoltage Protection................................. 5 Power Supply......................................... 5 Current Consumption.................................. 5 Grounding............................................ 5 Performance Characteristics..........................6 Display (LCD)......................................... 6 Operating Conditions: Installation.....................7 Mounting on The Wall................................. 7 Display............................................... 7 Mounting on A Pipe................................... 7 Operating Conditions: Environment and Process........ 8 Ambient Temperature................................. 8 Storage Temperature.................................. 8 Degree of Protection................................... 8 Electromagnetic Compatibility........................... 8 Cable Entries......................................... 8 Mechanical Construction............................ 9 Dimensions........................................... 9 Weight.............................................. 9 Housing Material...................................... 9 Human Interface................................... 10 Operation Concept.................................... 10 Display Operation.................................... 10 Certificates and Approvals.......................... 11 CE Mark............................................ 11 Ex Approvals........................................ 11 External Standards and Guide Line...................... 11 Ordering Information.............................. 12 NRF560............................................. 12 Accessories....................................... 13 Bracket............................................. 13 Supplementary Documentation..................... 14 Technical Information................................. 14 Operating Instructions................................ 14 Safety Instructions.................................... 14 2 Endress+Hauser

Important Document Information Notes on Safety Conventions and Symbols Symbols for Safety Conventions Symbol Meaning DANGER A0011189-EN WARNING A0011190-EN CAUTION NOTICE A0011191-EN A0011192-EN DANGER! This symbol alerts you to a dangerous situation. Failure to avoid this situation will result in serious or fatal injury. WARNING! This symbol alerts you to a dangerous situation. Failure to avoid this situation can result in serious or fatal injury. CAUTION! This symbol alerts you to a dangerous situation. Failure to avoid this situation can result in minor or medium injury. NOTICE! This symbol contains information on procedures and other facts which do not result in personal injury. Symbols for Certain Types of Information Symbol Meaning Allowed Indicates procedures, processes or actions that are allowed. A0011182 Recommendation Indicates procedures, processes or actions that are recommended. A0011183 Forbidden Indicates procedures, processes or actions that are forbidden. A0011184 A0011193 Tip Indicates additional information. Endress+Hauser 3

U-D Function and System Design System Design NRF 560 is a tank side monitor and control station for NMS of intelligent tank gauges. NRF 560 is a simple low-cost tank side monitor for displaying interface level, tank bottom level, and temperature. Additionally, NMS can be operated to measure the level, interface level, bottom level, or to hoist the displacer. The tank gauge is operated by three visual operating elements ("touch control"). For the transmission between NMS5 and NRF 560, a two-wire HART protocol is utilized. NMT53 series NMS5/7 E - + Power (AC / DC) Output: Primary Digital V1 Serial Bus RS485 HART Mark Space WM550 Enraf BPM Output: Secondly Analog 4 SPST, alarm output 4-20mA x 2 channel Temperature Liquid & Gas/ Vapor Level Tank Bottom Interface Level Density Local HART NRF560 0.0 C LEVEL Displacer Operation Temperature Display Displacer Position for: 1. Liquid Level 2. Interface Level 3. Bottom Level Power (AC / DC) LEVEL 0.0 C U-D Level Temperature Displacer status Gauge status Figure 1: NRF560 System Configuration 4 Endress+Hauser

Input and Auxiliary Energy Measured Variables Communication Multidrop local HART 2 wire, Endress + Hauser HART protocol to host communication gauge NMS auxiliary energy NRF560 Terminals Internal Power to power Module N Lighting Arrester V2 V1 V1 E V2 L1 N 2 4 6 8 10 9 Power Supply High Voltage: 85-264 VAC, 50/60 Hz N L Low Voltage: 20-62 VDC / 20-55 VAC, 50/60 Hz L 7 5 N Remote Communication 1113 15 17 19 L+ L- 1214 16 18 20 Remote Comm. Signal from CPU Module 3 1 L1 Terminal No.1 Terminal No.3 CAUTION 9 7 5 2 13 15 4 Lightning Arrester 2 Power Supply Fuse Ground Terminal for Cable Screen Signal Cable Caution! Use the cable gland attached to NRF560 for TIIS Ex d IIB T4. In all other specifications, the cable graldn is not provided. Figure 2: NRF560 Terminals Confirm that the main power is turned off. Insert power supply and signal cables from the designated cable entries (see below). Connect cables to each terminal. Use a general crimped connection (not supplied) and do make sure wires are safely and securely connected. After completing all electric connections, replace the terminal cover with screws. Secure the plastic terminal guard. Replace the terminal cover. Overvoltage Protection Power Supply NRF560 has internal surge arrester which complies with EN/IEC 61000-4-5 (Line to Line 1.0kV, Line to ground 2.0kV) Connect the metallic housing of the NRF560 to the tank wall or screen directly with an electrically conductive lead to ensure reliable potential matching. 85-264VAC, 50/60Hz, 25VA 20-62VDC, 20-55VAC, 50/60Hz, 25VA WARNING Allowable voltage supply is specified depending on each Ex approval. Refer to the designated certification. Current Consumption Grounding Maximum 25 VA NRF560 must be grounded to the tank potential before connection to host gauge. All ground connections must be compliant with local and company regulations, and checked before the equipment is commissioned. Endress+Hauser 5

Performance Characteristics Display (LCD) 4 lines. 128 x 64 (pixels) Language selection: English, Chinese, Japanese 6 Endress+Hauser

Operating Conditions: Installation Mounting on The Wall NRF 560 Standard Bracket M6 x 4 pcs. Ø55 LEVEL 0.0 C U-D Ø 7, 4 Holes PCD 78 Cable Gland Flexible tube, Conduit, or Steel Armoured Cable Figure 3: NRF560 Installation Display LEVEL 0.0 C U-D LEVEL 0.0 C U-D Figure 4: NRF560 Display NRF560 display can be rotated at 90 degrees when removing the cover. Mounting on A Pipe Cable Gland NRF560 U bolt (2 (50A)) Flexible Tube, Conduit, or Steel Armoured Cable Standard Bracket 2"(50) pipe Figure 5: 2" (50A) Pipe Endress+Hauser 7

Operating Conditions: Environment and Process Ambient Temperature Storage Temperature Degree of Protection Electromagnetic Compatibility Cable Entries -20 to +60 C(-4 to +140 F) -20 to +60 C(-4 to +140 F) IP67 Electromagnetic compatibility meets with EN 61326-1. The following cable entries are available: G1/2 NPT 1/2 M 20 CAUTION For TIIS, Ex d IIB T4, cable glands are provided. Be sure to use provided cable glands. For all other specifications, except TIIS, Ex d IIB T4, cable glands are not provided. 8 Endress+Hauser

Mechanical Construction Dimensions 229 179 70 1 123 111 4 3 2 105 66 172 ø134 LEVEL 0.0 C U-D 5 200 150 110 Standard Bracket Ø12 4 holes 1. Electrical Compartment 2. Terminal Box 3. LCD 4. Cable Entry 5. Touch Control U bolt (Option) Approx. 30 30 Approx. Ø60 74 74 110 Body Color: Blue Suitable Bolt: U bolt (option ) Plate Thickness: max. 15mm Approx. 85 M10 Figure 6: Dimensions Weight Housing Material Approx. 6.5 kg Aluminum, coated with rust-inhibitor paint Endress+Hauser 9

Human Interface Operation Concept NRF560 is operated by three visual operating elements, namely the keys "E", "+", and "-". They are actuated when the appropriate field on the protective glass of the front is touched with the finger ("touch control"). The corresponding transmitting and receiving diodes are not affected by external influences, e.g. direct sunlight. The software and hardware installed in NRF560 rule out any malfunction that may be caused in this way. Even in explosive hazardous areas, the explosion-proof housing of the touch control ensures a safe access to the data. Operational Security The software and hardware installed in NRF560 rule out any malfunction that may be caused in this way. Even in explosion hazardous areas, the explosion-proof housing of the touch control ensures safe access to the data. Key E Function Access to the programming matrix (touching the key for more than 3 s) Return to the HOME position (touching the key for more than 3 s) Moving horizontally within a function group to select functions Saving parameters or access code + Moving vertically to select function groups Selecting or setting parameters Setting access code Display Operation NRF560 has an illuminated LCD that consists of 4 lines with 128 x 64 (pixels). During normal operation, NRF560 shows level, temperature, and status of the device at "HOME" position. NRF560 also shows other data by touching "E, -, +" keys (a light touch with the fingertips is enough to show data). Illuminated LCD LEVEL 0.0 C U-D Infrared Transmitting Diaode Infrared Receiving Diaode 3 Optical Operating Elements "Touch Control" Figure 7: Display 10 Endress+Hauser

Certificates and Approvals CE Mark Ex Approvals External Standards and Guide Line The measuring system meets the legal requirements of the EC-guidelines. Endress+Hauser confirms the instrument passing the required tests by attaching the CE mark. TIIS Ex d IIB T4 FM XP Cl.I, Div.1, Gr.A-D CSA Cl.I, Div.1, Gr.A-D ATEX II 2G Ex d IIC T4 ATEX II 2G Ex d IIC T4, NMi IECEx, Ex d IIC T4 Gb NEPSI Exd IIC T4 To conception and development for NRF560 have been followed the external standards and guidelines: EMC-Directive 89/336/EC EN 60529 Protection class of housing (IP code) Endress+Hauser 11

Ordering Information NRF560 010 Approval: 0 Weather proof, IP67 NEMA 4X 1 TIIS Ex d IIB T4 4 FM XP Cl.I, Div.1, Gr.A-D 5 CSA Cl.I, Div.1, Gr.A-D 6 ATEX II 2G Ex d IIC T4 8 ATEX II 2G Ex d IIC T4, NMi F IECEx, Ex d IIC T4 Gb G NEPSI Exd IIC T4 9 Special version, TSP-no, to be spec. 020 Cable Entry: A 2x thread G1/2 B 2x thread NPT1/2 D 2x thread M20 Y Special version, TSP-no, to be spec. 030 Power Supply: 3 85-264VAC, 50/60Hz 4 20-62VDC, 20-55VAC, 50/60Hz 9 Special version, TSP-no, to be spec. 040 Mounting Bracket: 0 not selected 1 selected 9 Special version, TSP-no, to be spec. 050 Color: 0 blue 9 Special version, TSP-no, to be spec. NRF560- Completion product designation 12 Endress+Hauser

Accessories Bracket U bolt is not provided with bracket for installing NF560 to a tank. Contact Endress+Hauser Japan if needed. Standard Bracket U Bolt (Option) 200 150 Ø12x4 Approx. Ø60 74 Approx. 85 M10 30 74 110 Figure 8: Bracket Endress+Hauser 13

Supplementary Documentation Technical Information Operating Instructions TI 00452G Technical Information Proservo NMS5 BA 00425G Operating Instructions NRF560 BA 00401G Operating Instructions Proservo NMS5 Safety Instructions XA 00664G (IECEx) XA 00586G (ATEX) XA01258G (NEPSI) 14 Endress+Hauser

www.addresses.endress.com