Determination of suitable hardware for the Process Historian 2014 with the PH-HWAdvisor tool

Similar documents
Application example 02/2017. SIMATIC IOT2000 Connection to IBM Watson IoT Platform SIMATIC IOT2040

Application example 12/2016. SIMATIC IOT2000 OPC UA Client SIMATIC IOT2020, SIMATIC IOT2040


Configuration of an MRP Ring and a Topology with Two Projects

SINAMICS G/S: Integrating Warning and Error Messages into STEP 7 V5.x or WinCC flexible

Setting up time synchronization of Process Historian and Information Server

Setting up 08/2017. Setting up the SIMATIC IOT2000 SIMATIC IOT2020, SIMATIC IOT2040

Data Storage on Windows Server or NAS Hard Drives

Migration of a Process Historian database

Windows firewall settings for X-Tools Server Pro. CMS X-Tools / V / CPU PN/DP. Application description 6/2016

Setting up 01/2017. Setting up the SIMATIC IOT2000 SIMATIC IOT2020, SIMATIC IOT2040


RAID systems within Industry

Improving the performance of the Process Historian


Integration of Process Historian / Information Server in a Domain

Checking of STEP 7 Programs for the Migration of S7-318 to S CPU318 Migration Check. Application description 01/2015

Automatic Visualization of the Sample Blocks in WinCC Advanced



Check List for Programming Styleguide for S7-1200/S7-1500

X-Tools Loading Profile Files (LPF)

SIMATIC NET OPC Server Implementation

SINAMICS G/S: Tool for transforming Warning and Error Messages in CSV format

APF report templates based on data from the WinCC User Archive


Multiuser Engineering in the TIA Portal

Position Control with SIMATIC S and SINAMICS V90 via IRT PROFINET SINAMICS V90 PROFINET. Application description 03/2016

Configuration of an MRP ring with SIMOCODE and SIMATIC S SIMOCODE pro V PN, SIMATIC S Siemens Industry Online Support

Library Description 08/2015. HMI Templates. TIA Portal WinCC V13.


Generating the Parameters for the Modbus/TCP Communication




PNDriver V2.1 Quick Start Guide for IOT2040 SIMATIC IOT

SIMATIC Energy Suite Visualization example of the "*.csv"-energy Data Files

Acyclic communication between S and V90PN via PROFINET. Application example 12/



Moving a Process Historian/ Information Server from Workgroup A to Workgroup B


Display of SINAMICS Fault Messages in WinCC V7.4




Display of SINAMICS Error Messages in Runtime Professional

Calculating the expected PH storage requirements of SIMATIC BATCH batches

Networking a SINUMERIK 828D


Transmitting HMI data to an external monitor

Exchange of large data volumes between S control system and WinCC

House Control with Touch Panel

Communication between HMI and Frequency Converter. Basic Panel, Comfort Panel, Runtime Advanced, SINAMICS G120. Application Example 04/2016



Plant Data Interface for the Food & Beverage Industry in SIMATIC PCS 7. Interface description based on Weihenstephan Standards

Installation of a Process Historian on a Fujitsu Primergy Server

Setting up a secure VPN connection between two SCALANCE S Modules Using a static IP Address


Application on Control Technology

Visualizing Energy Data of a SITOP PSU8600

User Login with RFID Card Reader

Cover. WinAC Command. User documentation. V1.5 November Applikationen & Tools. Answers for industry.

STEP 7 function block to control a MICROMASTER 4 or SINAMICS G120/G120D via PROFIBUS DP

Key Panel Library / TIA Portal

S Data Transfer with SEND/RECEIVE Interface


SIMATIC Visualization Architect (SiVArc) Getting Started

Single Message Report for the Information Server. SIMATIC PCS 7, SIMATIC Information Server Siemens Industry Online Support



STEP 7 Professional V14 SP1, Energy Suite V14 SP1, SENTRON PAC Measuring Devices, Modbus TCP

SIMATIC PDM - Central access to MODBUS RTU devices

Production feedback via WinCC Data Transfer with XML file

Check List for Programming Styleguide for S7-1200/S7-1500

Setting up a secure VPN Connection between SCALANCE S and SSC Using a static IP Address. SCALANCE S, SOFTNET Security Client


PCS 7 Process Visualization on Mobile Devices with RDP

Message Cycle Report for the Information Server. SIMATIC PCS 7, SIMATIC Information Server Siemens Industry Online Support

X-Tools configuration to connect with OPC servers and clients

TeleService of a S station via mobile network

Applikationen & Tools. Network Address Translation (NAT) and Network Port Address Translation (NAPT) SCALANCE W. Application Description July 2009


Report operator actions with the WinCC WebNavigator

Integral calculation in PCS 7 with "Integral" FB or "TotalL" FB

SIMATIC PCS 7 Minimal Configuration


Universal Parameter Server

Integration of SIMATIC PCS 7 Asset Management into existing projects

Topology Reporter Tool Description April 2012 Applications & Tools Answers for industry.

Setting up a secure VPN Connection between the TS Adapter IE Advanced and Windows 7

Recording user activity on a SIMATIC Controller using a SIEM System. SIMATIC Controller S H, S7-410E SIMATIC PCS 7

Application for Process Automation

Tracking the MOP setpoint to another setpoint source to bumplessly changeover the setpoint

Applications & Tools. Service Concept: Auto Backup for the Comfort Panels. WinCC (TIA Portal) V12. Application Description May 2013

Engineering of the Configuration Control for IO Systems


Block for SIMOTION SCOUT for Monitoring 24V-Branches

SINAMICS V: Speed Control of a V20 with S (TIA Portal) via MODBUS RTU, with HMI

Transcription:

Application example 12/2016 Determination of suitable hardware for the Process Historian 2014 with the PH-HWAdvisor tool SIMATIC Process Historian 2014 https://support.industry.siemens.com/cs/ww/de/view/109740115

Warranty and Liability Warranty and Liability Note The Application Examples are not binding and do not claim to be complete regarding the circuits shown, equipping and any eventuality. The Application Examples do not represent customer-specific solutions. They are only intended to provide support for typical applications. You are responsible for ensuring that the described products are used correctly. These Application Examples do not relieve you of the responsibility to use safe practices in application, installation, operation and maintenance. When using these Application Examples, you recognize that we cannot be made liable for any damage/claims beyond the liability clause described. We reserve the right to make changes to these Application Examples at any time without prior notice. If there are any deviations between the recommendations provided in these Application Examples and other Siemens publications e.g. Catalogs the contents of the other documents have priority. We do not accept any liability for the information contained in this document. Any claims against us based on whatever legal reason resulting from the use of the examples, information, programs, engineering and performance data etc., described in this Application Example shall be excluded. Such an exclusion shall not apply in the case of mandatory liability, e.g. under the German Product Liability Act ( Produkthaftungsgesetz ), in case of intent, gross negligence, or injury of life, body or health, guarantee for the quality of a product, fraudulent concealment of a deficiency or breach of a condition which goes to the root of the contract ( wesentliche Vertragspflichten ). The damages for a breach of a substantial contractual obligation are, however, limited to the foreseeable damage, typical for the type of contract, except in the event of intent or gross negligence or injury to life, body or health. The above provisions do not imply a change of the burden of proof to your detriment. Any form of duplication or distribution of these Application Examples or excerpts hereof is prohibited without the expressed consent of the Siemens AG. Security information Siemens provides products and solutions with industrial security functions that support the secure operation of plants, systems, machines and networks. In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement and continuously maintain a holistic, state-of-the-art industrial security concept. Siemens products and solutions only form one element of such a concept. Customer is responsible to prevent unauthorized access to its plants, systems, machines and networks. Systems, machines and components should only be connected to the enterprise network or the internet if and to the extent necessary and with appropriate security measures (e.g. use of firewalls and network segmentation) in place. Additionally, Siemens guidance on appropriate security measures should be taken into account. For more information about industrial security, please visit http://www.siemens.com/industrialsecurity. Siemens products and solutions undergo continuous development to make them more secure. Siemens strongly recommends to apply product updates as soon as available and to always use the latest product versions. Use of product versions that are no longer supported, and failure to apply latest updates may increase customer s exposure to cyber threats. To stay informed about product updates, subscribe to the Siemens Industrial Security RSS Feed under http://www.siemens.com/industrialsecurity. Entry ID: 109740115, V3.0, 12/2016 2

Table of contents Table of contents Warranty and Liability... 2 1 Introduction... 4 2 Determine suitable hardware... 5 2.1 Creating a project-specific report... 5 2.2 Structure of report... 7 3 Menu explanations... 8 3.1 File... 8 3.2 Basic Settings... 9 3.3 HDD Price Settings... 10 3.4 Data Group Settings... 11 4 References... 12 5 History... 12 Entry ID: 109740115, V3.0, 12/2016 3

1 Introduction 1 Introduction The Process Historian is used for long-term archiving of process data and messages. To ensure optimum operation and constant availability of data, the Process Historian 2014 has been subjected to a special delivery release since March 2016, which needs the determination of the suitable hardware. Since 5th of September 2016 the obligatory consultation of the Systems Support has been replaced by the following process and the "PH-HWAdvisor" tool. The "PH-HWAdvisor" tool guides you through a catalog of questions on the individual requirements of your PCS 7 project and provides a results protocol with the recommended hardware, which has to be sent to the responsible Product Manager for getting the order approval. Follow these steps: 1. Download the tool. 2. Unzip and start the tool. 3. Fill in the fields provided and start the evaluation. 4. Send the signed protocol to the specified address in order to obtain order approval for the Process Historian 2014. Entry ID: 109740115, V3.0, 12/2016 4

2 Determine suitable hardware 2 Determine suitable hardware 2.1 Creating a project-specific report Data input Enter the general project information and information on the Siemens Sales region in the PH-HWAdvisor. Also enter information concerning the PCS 7 project, such as the number of PCS 7 OS systems that archive in the PH and information about the PH, e.g. for how many years the online availability of the data is required. Click the button Calculate to create the report. Based on these inputs the tool determines a suitable hardware for the Process Historian and outputs this as a report (HTML). Entry ID: 109740115, V3.0, 12/2016 5

2 Determine suitable hardware Printing After entering the required data, print out the report using the Print or PrintPreview button in the report dialog. Signing Sign the report in the signature field provided. Scanning Sending Scan in the signed report. Send the report via e-mail to the responsible product manager for the order approval: Mr. Dr. Dino Drinjakovic dino.drinjakovic@siemens.com Entry ID: 109740115, V3.0, 12/2016 6

2 Determine suitable hardware 2.2 Structure of report General information Memory requirements The report is divided into four areas: The input data are listed in this section. The storage requirements of the PH database for process values (in GB and TB), for the alarms (in GB and TB) and for the archive segments per year (in TB) are output here. Hardware recommendations Recommendations for the appropriate CPU, RAM and required hard disk / hard disk systems (hard disk array) as well as their partitioning are made in this section. Information for appropriate CPU Required memory Hard disk systems for alarms: 2x 600GB disks in RAID 1 Netw ork General recommendations This section offers information on back-up strategy, virtualization, ordering possibilities, etc. Entry ID: 109740115, V3.0, 12/2016 7

3 Menu explanations 3 Menu explanations 3.1 File Below you will find a detailed description of the menus and commands: New Open Save as Menu command Calculate Send configuration to PCS 7 Systems Support Description Creates a new empty configuration. Opens a configuration that had previously been saved. Saves the current entries as configuration under a name. Ascertains a suitable hardware and outputs a report on the basis of the current entries. If PH-HWAdvisor cannot make a valid hardware recommendation, the PCS 7 Systems Support must be consulted. Close Closes the PH-HWAdvisor. Entry ID: 109740115, V3.0, 12/2016 8

3 Menu explanations 3.2 Basic Settings In the Basic Settings dialog the basic settings for the following parameters are displayed: Days per segment = 7 Number of Runtime segments = 5 Number of Prepared segments = 1 Compression factor = 10 You must take these values into account - with the exception of the compression factor - when segmenting the Process Historian Archive in the PH dashboard. The above values are standard values for the segmentation of the PH database. Entry ID: 109740115, V3.0, 12/2016 9

3 Menu explanations 3.3 HDD Price Settings The hard disks or hard disk systems (hard-disk array) and their partitioning in Section 3 of the report is determined by the PH-HWAdvisor on the basis of the cost of the hard disks due to the required storage capacity. Hard Disk Drive costs are in the HDD Price Settings dialog, which can be accessed via the Settings menu Consideration of the appropriate hard disk for hardware recommendation Costs for hard disks In this dialog you can enter the cost of the individual hard disks. If a certain hard disk is not to be considered when determining the hardware recommendation, you can make the appropriate setting with the corresponding checkbox. Select the Ignore prices option in order for the hard disk prices not to be factored in to the hardware recommendation. When this is done, the PH-HWAdvisor bases its selection of hard disk or hard disk systems (hard disk array) and their partitioning exclusively on storage space requirements Entry ID: 109740115, V3.0, 12/2016 10

3 Menu explanations 3.4 Data Group Settings The Data group settings dialog shows the minimum number of data groups depending on the number of OS systems. 2 OS systems ore more: at least 2 data groups are considered for hardware recommendation for the storage of the process value. Entry ID: 109740115, V3.0, 12/2016 11

4 References 4 References Topic \1\ Siemens Industry Online Support https://support.industry.siemens.com \2\ Download page of this entry https://support.industry.siemens.com/cs/ww/de/view/109740115 \3\ Several instructions around the topic installation, configuration, commissioning and maintenance of the Process Historian (PH) and the Information Server (IS) https://support.industry.siemens.com/cs/ww/en/view/66579062 5 History Version Date Change V1.0 09/2016 First edition V2.0 09/2016 Update V2.1 09/2016 New tool version V3.0 12/2016 New tool version Entry ID: 109740115, V3.0, 12/2016 12