Contents. MicroDome Surface Mount Installation. Arecont Vision MicroDome Installation Manual

Similar documents
Contents. MicroDome Recess Mount Installation. Arecont Vision MicroDome Installation Manual

Installation Manual AV2245PM-W AV2246PM-W AV3245PM-W AV3246PM-W AV5245PM-W AV2245PM-D AV2245PM-D-LG AV2246PM-D AV2246PM-D-LG AV3245PM-D AV3245PM-D-LG

Installation Manual. Wide Angle Models AV2225PMIR AV2225PMIR-A AV2226PMIR AV3225PMIR AV3226PMIR AV3226PMIR-A AV5225PMIR AV5225PMIR-A AV10225PMIR

Installation Manual. MegaBall 2 PM Models (Remote Zoom, Remote Focus, P-iris) AV2245PM-W AV2246PM-W AV3245PM-W AV3246PM-W AV5245PM-W AV2245PM-D

MicroBullet Installation Manual

Arecont Vision MegaView TM v1x Installation Manual

Arecont Vision MegaDome Installation Manual

Arecont Vision MegaDome 2 Installation Manual (DN Models Only)

Arecont Vision MegaView TM v1 Installation Manual

Arecont Vision MegaDome TM Installation Manual

MegaVideo G5. Installation Manual. Models: 1.2 Megapixel AV1215PM-S. 1080p AV2215PM-S AV2216PM-S. 3 Megapixel AV3215PM-S AV3216PM-S.

Arecont Vision MegaView 2 Installation Manual. Installation Manual. Wide Angle Models AV10225PMTIR-S. Telephoto Models:

Arecont Vision MegaView TM Installation Manual

MegaVideo 4K Installation Manual

MegaVideo Flex. Installation Manual. Models: 1.2 Megapixel AV1195DN AV1195DN-NL. 1080p AV2195DN AV2195DN-NL AV2196DN AV2196DN-NL. 3 Megapixel AV3195DN

Installation Manual. Wide Angle Models: IR Motorized Model. DN Motorized Model AV1255PM-SH AV3256PM-A AV2256PMIR-S AV3256PMIR-SA AV10255PMIR-SH

Fantasea Blue Ray Tray (Cat. No. 2040, 2045, 2050) Instruction Manual

IS-DM220/IR/HB IS-DM220

Quick Start Guide V5.1.

GH-30. Gimbal Head. You re on steady ground

DUAL-ARM MONITOR MOUNT For in. ( cm) desktop computer monitors

GV-IPCam H.264. Hardware Manual. Vandal Proof IP Dome Target Vandal Proof IP Dome

PV Series. Owner s Manual. Photo Tripod

Universal Tablet Holder

2M IR Mini Dome Quick Installation Guide

Installation and User Guide

IQeye Alliance-mx Vandal-Resistant IP Camera. Installation and Operating Instructions

FLEXIBLE MACRO BRACKET WITH ARCA-STYLE MOUNT. User Manual

MACROFIER Reverse Mount and Extension Tube with Automatic Functionality for Canon EOS Lenses. User Manual

IQeye Alliance Series

VITEK VTC-TNB8RFS. Transcendent Series 8 Megapixel H.265 Indoor/ Outdoor WDR IP Bullet Camera with 36 IR LED Illumination QUICK START GUIDE

DX-M. Owner s Manual. Photo Tripod

FH M AIRCRAFT ALUMINUM FILTER HOLDER. for Nikon 14-24mm f/2.8 G AF-S lens. User Manual

ZC-OH5 TAMPER-RESISTANT INDOOR/OUTDOOR HOUSING INSTRUCTION MANUAL FOR USE WITH GANZ ZC-D5000 SERIES MINIDOME CAMERAS

3-Lamp Fluorescent Ring Light 19" INSTRUCTIONS

MPP200 User s Manual

ZAVIO Outdoor IR Mini Dome. Quick Installation Guide

Contera Outdoor Dome Installation Manual

with External Springs

VITEK VTD-THD2RFE VTC-THT2RFE VTC-THB2RFE. 2.1 Megapixel Indoor/Outdoor HD-TVI/ AHD/CVI/CVBS IR Cameras

CC186 AND CC186/2 STAND-ALONE OR SYSTEM CLOCK

NBS-2X NIMBUS STABILIZER QUICK-START GUIDE

RS-600AF-V2 RS-850AF-V2. Camera. Track Slider. with Adjustable Feet

Next Gen Sarix Enhanced IME Series Mini Dome Cameras

Model#: IN-DO3MIRF 3MP Outdoor Dome with True Day/Night, IR, Basic WDR, Fixed lens

Standard Dome Accessories Accessories for Indoor/Outdoor Ceiling, Wall, Pole and Corner Mounting Solutions

Quick Start Guide.

BTU 4 & Sensors. Installation and Operation Manual

PSL-C / PSL-N / PSL-R PowerSlave Transmitter / Receiver INSTRUCTIONS

Shoulder Support System

RS-600AF RS-850AF RS-1200AF. Camera. Track Slider. With Adjustable Feet

MD-BSL15W / SPRING-LOADED TWIN-ARM. For ( cm) LCD desktop computer. User Manual

Warning Before Installation. Package Contents EN - 1. Refer to your user s manual for the operating temperature.

MTX-A Temperature Gauge User Manual

Auto Lens Adapter. Four Thirds Lens to Micro Four Thirds Camera

IQeye Alliance-mini Series. Installation and Operating Instructions

MicroDome. Series Accessories. Accessories. Accessories for MicroDome and MicroDome G2 Indoor/Outdoor Ceiling, Wall, and Corner Mounting Solutions

SD1306. Speed Dome IP Camera. Quick User Guide

RAS REFLECTOR ADAPTER FOR SPEEDLIGHT

Warning Before Installation. Package Contents EN - 1. Refer to your user's manual for the operating temperature.

MD-BD13B / DUAL SEGMENT TWIN-ARM. For (33-69 cm) LCD desktop computer monitors. User Manual

Warning Before Installation

Outdoor PTZ. Mounting on the Ceiling Using Pendant Mount. Installation Guide. For Models: I93, I94, I95, I96, KCM /12/03

TAKAMA FLIP-ZIP INTRODUCTION. KEY FEATURES (Illustration - 1) MULTI-FUNCTIONAL TRIPOD MONOPOD KIT. Thanks for choosing Takama!

VITEK VTD-TND4RMS FEATURES

VIP-480AL IP One-Way Horn

QUICK START GUIDE. 1. How to register your Camera to Hubble account A. Setting Up the Camera - can be connected via WiFi or LAN

FREEWAVE FUSION USER MANUAL

NT1B-300 Rack Installation Instructions

HVPS-C. High Voltage Power Supply. HVPS-C. Package Contents: Sold Separately. Table of Contents:

VIP-148AL IP Talkback Horn

Next Gen Sarix Enhanced IME Series Mini Dome Cameras

500 SERIES. Hardware Installation and Modification Manual. Process Controllers. for Electronic Products Series 531, 532, 535, 545, 555 Model 2

VIP-804 QUAD ENHANCED NETWORK AUDIO PORT

MPP1700 User s Manual

Sarix Professional IMP Series 3.75 Indoor Dome. Quick Start Guide IMP121-1IS IMP221-1IS IMP321-1IS IMP521-1IS C2291M-B-EN (12/16)

LED-200P. Mobile LED Light Set. User Manual

RAPID LENS CHANGER. User Manual

FortiCam FD40 Mounting Guide

Fabric Rain Cover RC-FC500 RC-FC500B. for Canon and select Nikon DSLRs. Fits lenses from 7 14 long and lens diameters of

GV-IPCam H.264. Hardware Manual. Bullet Camera Ultra Bullet Camera Target Bullet Camera

VIP-812A DUAL NETWORKED STATION PORT

BTU-4D/BTU-4D-I Digital Temperature Unit & Sensors. Installation and Operation Manual

AE21 SERIES DISPLAY CONTROL TERMINAL

User s Manual. Revision 1.0. Copyright 2008 Maretron, LLP All Rights Reserved

Escort LED LIGHTS USER MANUAL

PSA200 User s Manual

AUTO LENS ADAPTER. User Manual. LAE-SE-NF Nikon F-Mount to Sony E-mount Camera

IQeye Sentinel Series Indoor/Outdoor Camera. Installation and Operating Instructions

HeadMouse Extreme. Bracket Installation Instructions for DynaVox Maestro. Additional Resources. Bracket Installation Instructions for Maestro

Owner s Manual. TSD-DCPDV DC Power Distribution with Fixed & Variable Outputs. TSD-DCPDV DC Power Distribution. AtlasSound.com

MTX-A, Fuel Pressure Gauge PSI

PD10. Pulse Divider Instructions PROUDLY MADE IN THE USA

Camera Features. Package Contents. Camera Features

Arecont Vision HSG2 Installation Manual

AirLink GX Series X-Card Installation Guide

VE8014A/VE8014AR QUAD NETWORKED STATION PORT

COBALT C INSTALLATION GUIDE RFID CONTROLLER ESCORT MEMORY SYSTEMS. High Frequency Passive Radio Frequency Identification Controller

QSB (Q-Star) Electronics for QSE Electromagnetic Meter. Owner s Manual TABLE OF CONTENTS

IQeye 4 Series Dome. IQinVision. When you can t afford to miss a thing. Installation & Operating Instructions

Transcription:

INSTALLATION MANUAL AV1455DN-S AV2455DN-S AV2456DN-S AV3455DN-S AV3456DN-S AV5455DN-S

MicroDome Surface Mount Installation Contents Package Contents... 3 Warranty Information... 3 Installation Overview... 4 Installation... 5 Focusing the Camera... 7 Changing the Lens... 8 Focusing Alternate Lenses... 8 Digital Input and Output... 9 LED Indicators... 10 Support... 11 Camera Discovery, Setup, and Configuration... 12 Wall Mount Accessory... 13 Pendant Mount Accessory... 14 Mount Template: MicroDome Camera... 15 Mount Template: MicroDome Wall Mount... 16 Mount Template: MicroDome Pendant Mount... 17 Page 2

Package Contents Item MegaPixel Camera Mounting Kit Arecont Vision CD Description MicroDome Ceiling template 6x Mounting Screws 3/8 NPT Male to 1/2 NPT Female Adapter Network Patch Cable 3x Security Torx Dome Cover Fasteners Manual, Warranty, Installation Software Warranty Information 3 Year Limited Warranty ARECONT VISION warrants to Purchaser (and only Purchaser) (the Limited Warranty ), that: (a) each Product shall be free from material defects in material and workmanship for a period of thirty-six (36) months from the date of shipment (the Warranty Period ); (b) during the Warranty Period, the Products will materially conform with the specification in the applicable documentation; (c) all licensed programs accompanying the Product (the Licensed Programs ) will materially conform with applicable specifications. Notwithstanding the preceding provisions, ARECONT VISION shall have no obligation or responsibility with respect to any Product that (i) has been modified or altered without ARECONT VISION s written authorization; (ii) has not been used in accordance with applicable documentation; (iii) has been subjected to unusual stress, neglect, misuse, abuse, improper storage, testing or connection; or unauthorized repair; or (iv) is no longer covered under the Warranty Period. ARECONT VISION MAKE NO WARRANTIES OR CONDITIONS, EXPRESS, IMPLIED, STATUTORY OR OTHERWISE, OTHER THAN THE EXPRESS LIMITED WARRANTIES MADE BY ARECONT VISION ABOVE, AND ARECONT VISION HEREBY SPECIFICALLY DISCLAIMS ALL OTHER EXPRESS, STATUTORY AND IMPLIED WARRANTIES AND CONDITIONS, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, NON-INFRINGEMENT AND THE IMPLIED CONDITION OF SATISFACTORY QUALITY. ALL LICENSED PROGRAMS ARE LICENSED ON AN AS IS BASIS WITHOUT WARRANTY. ARECONT VISION DOES NOT WARRANT THAT (I) THE OPERATION OF THE PRODUCTS OR PARTS WILL BE UNINTERRUPTED OR ERROR FREE; (II) THE PRODUCTS OR PARTS AND DOCUMENTATION WILL MEET THE END USERS REQUIREMENTS; (III) THE PRODUCTS OR PARTS WILL OPERATE IN COMBINATIONS AND CONFIGURATIONS SELECTED BY THE END USER; OTHER THAN COMBINATIONS AND CONFIGURATIONS WITH PARTS OR OTHER PRODUCTS AUTHORIZED BY ARECONT VISION OR (IV) THAT ALL LICENSED PROGRAM ERRORS WILL BE CORRECTED. For RMA and Advance Replacement information visit ArecontVision.com Page 3

Installation Overview Ceiling Gasket NPT Port Camera Housing Mounting Screws Gasket Captive Fasteners (Hand Tighten Only) Dome Cover Page 4

Arecontt Vision MicroDome Installation Manual Installation Tech Tip 1. Visit http://www.arecontvision.com/ and check to ensure your camera has the most current firmware. 2. For installations in harsh environments it is recommended to use all six mounting screws supplied with your camera to create the best seal possible betweenn your camera and the mounting surface using the supplied gasket. 3. If using the NPT port always use Teflon tape around threads to ensure proper sealing. 4. After plugging in the network cable check that the indicator LED ss are indicating the desiredd conditions (see LED Indicator table). 5. Use Arecont Vision software AV100 or AV200 locatedd on the CD or available for download at our website (www.arecontvision.com) for camera discovery and setup (see Instruction Manual located on CD or available on our website). 6. Adjust the pan and tilt to obtain the desired field of view (see Focusing Instructions). 7. Lens may be further secured by tightening the lens lock screw using Phillips head screwdriver. 8. Install the Dome Cover by aligning the captive fasteners with the mating threaded holes on the camera housing. 9. When mounting the Dome Cover to the Camera Housing ensure that the gasket is properly seating and not folded. Failure to do so may result in water and dustt ingress. 10. When mounting the Dome Cover to the Camera Housing do not over torque the three captive fasteners as this will cause the threads to strip. Only hand tighten these screws.. Best Practice Tips When mounting to vertical surface it is best to use the Wall Mount Accessory (MCD WMT) which includes a junction box. For outdoor use it is always best to properly seal the product using caulk around the edges to prevent water ingress from mounting to porous or uneven surfaces. Use Teflon tape on threaded interfaces. Use all 6 supplied mounting screws for best seal when mounting outdoors. Page 5

Page 6

Arecontt Vision MicroDome Installation Manual Focusing the Camera Tech Tip Tech Tip 1. Open a live view of the camera from your web browser or the AV Software provided (AV1000 or AV200). 2. Loosen the lens lock screw using a phillips head screwdriver (if necessary). Only do so if lens seems veryy tight when turning. Lock screw should be tightened enough to provide some friction against the lens to avoid focusing problems. 3. Manually rotate the lens to adjust the focus until the desired image is obtained. 4. For some lenses a focus shift will occur once the bubble is in place. Hold the bubble up to the lens whenn focusing to account for the focus shift or see the Focusing Alternate Lenses section below for further instruction. 5. Retighten the lock screw if necessary. 6. Install the Dome Cover by aligning the captive fasteners with the mating threaded holes on the camera housing. 7. When mounting the Dome Cover to the Camera Housing ensure that the gasket is properly seating and not folded. Failure to do so may result in water and dust ingress. 8. When mounting the Dome Cover to the Camera Housing do not over torque the three captive fasteners as this will cause the threads to strip. Only hand tighten these screws.. Page 7

Arecontt Vision MicroDome Installation Manual Changing the Lens 1. Remove the Dome Cover by loosening the captive fasteners. 2. Loosen the lens lock screw using a phillips head screwdriver (if necessary). Only do so if lens seems veryy tight when turning. 3. Manually unscrew the lens, this may take several seconds. 4. Replace lens. 5. Retighten the lock screw if necessary. 6. Reinstall Dome Cover per instructions outlined above. Focusing Alternate Lenses When focusing the 6mm, 8mm, 12mm or 16mmm lens optionss you will encounter a focus shift when using the bubble. To account for this follow these steps: Tech Tip 1. Focus the camera without the bubble. 2. Rotate the lens per the chart below. The rotation will account forr most of the focus shift. 3. Put cover with bubble on. You should be close to being focused. 4. Remove cover and rotate a couple degrees at a time in either direction until you gain the desired image.. Lens MPM16.0 MPM12.0 MPM8.0 MPM6.0 16mm 12mm 8mm 6mm Rotation <3/4 CCW 250 1/4 CCW 90 >1/8 CCW 60 1/8 CCW 45 Example: Using a 16mmm lens you will focus the lens without the bubble until you get the desired image. Rotate the lens almost ¾ of a turn (250 ). Put the bubble on and view the image.. It should be almost in focus. Removee the bubble and rotate a degree or two in one direction and view the image with the bubble on. Depending on the image you may need to adjust in the opposite direction or continue in the same direction until the desired image is obtained. Page 8

Digital Input and Output Use 4 position connector inside camera housing to interface with Digital I/O. DIGITAL I/O BLACK IN WHITE IN + YELLOW OUT ORANGE OUT + Electrical Characteristics MIN MAX Input Voltage (V) (Measured between + and terminals) Output Current (ma) (Measured between + and terminals) Applied Voltage Range : 0 80V ON 2.9 6.3 OFF 0 1.3 ON 50 OFF 0.1 NOTE: Both the input and the output are electrically isolated from the rest of the camera s electrical circuitry via general purpose photo couplers. The input is additionally protected with a serial 250 Ohm resistor and a debouncing circuit. Duration of any input signal should be at least 5ms to comply with the requirements of the debouncing circuit. Page 9

LED Indicators LED Status Description Yellow Flashing Link has been established. Solid Normal Operation. None No connection. Green Flashing Camera has been accessed. Normal operation. Solid N/A None No Connection. Page 10

Support 1. Arecont Vision FAQ Page Located at ArecontVision.com 2. Check the following before you call: Restore camera to factory default with AV100, AV200 or the camera webpage. Upgrade to the latest firmware by visiting ArecontVision.com. Isolate the camera on a dedicated network and test with AV100 or AV200. Swap the troubled camera with a known good camera to see if the problem follows the camera or stays at the location. 3. Contact Arecont Vision Technical Support one of three ways: 1. Online Portal : Support.ArecontVision.com 2. Phone : 1.818.937.0700 (option #1) 3. Email : Page 11

Camera Discovery, Setup, and Configuration For camera discovery and setup please use Arecont Vision software AV200 which you can find on the CD included with your camera or at: http://www.arecontvision.com/softwares.php The user manual for the AV200 software is included on the CD and is also located on our website. To configure the camera use either the AV200 software or the web interface utility. The web interface can be accessed by typing the camera IP address into your web browser or by clicking on the web interface button in AV200. The user manual for our web interface is included on the CD and is also located on our website. Page 12

Arecontt Vision MicroDome Installation Manual Gasket Alignment features must be aligned for proper installation. Wall Mount Accessor ry (MCD WMT) Installation Notes: 1. Always ensure gaskets are properly seated. 2. Use Teflon tape on threaded interfaces. 3. 3/8 male to 1/2 female NPT adapter included. 4. Mount holes from camera housing to flange are not symmetrical. Alignment features indicated must be properly lined up for mount hole alignment t. Page 13

Pendant Mount Accessory (MCD CMT) Arecontt Vision MicroDome Installation Manual Installation Notes: 1. 2. 3. 4. Always ensure gaskets are properly seated. Use Teflon tape on threaded interfaces. 3/8 male to 1/2 female NPT adapter included. Mount holes from cameraa housing to flange are not symmetrical. Alignment features indicated must be properly lined up for mount hole alignment. Gasket Alignmentt features must be aligned for proper installation. Page 14

Mount Template: MicroDome Camera Page 15

Mount Template: MicroDome Wall Mount Page 16

Mount Template: MicroDome Pendant Mount Page 17

Contact Arecont Vision Technical Support one of three ways: Online Portal : Support.ArecontVision.com Phone : 1.818.937.0700 (option #1) Email : Page 18