PowerCore Model TEC-10 Installation Manual

Similar documents
*Approved by CSA for non-hazardous locations (Group Safety Publication IEC Third Edition).

PowerView Model PV485. Installation Manual Section 78

HelmView 450 Model HV450. Installation Manual Section 78

HelmView Model HV750; HVS750. Installation Manual Section 78

HelmView Model HV750. Installation Manual Section 78

PowerView Model PV750. Installation and Operations Manual Section 78

MLC 380 R2. For Mechanical Engines. Installation Manual

PowerView Model PV450. Installation and Operation Manual Section 78

PowerView Model PV350 and PV380. Installation Manual Section 78

PowerView Model PV1000. Hardware Installation Manual Section 78

EMS467 Monitoring System. Installation and Operations Manual Section 40

PowerView Model PV450. Installation and Operation Manual Section 78

PowerView Model PV450. Installation and Operation Manual Section 78

TECHNICAL DATASHEET #TDAX050000K CAN

PanelView Plus/VersaView CE Terminals and Display Modules

PowerView TM Model PV350 and PV380. Operations Manual Section 78

EX-RC1 Remote I/O Adapter

EXPRESS SETUP. PanelMate 1700 Series PanelMate Power Pro. Cutler-Hammer

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

DATA SHEET Compact Genset Controller, CGC 200

INSTALLATION INSTRUCTIONS

General-Purpose Photoelectric Sensor

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

COMPACT FLEXIBLE ALL IN ONE INDUSTRIAL PUMP CONTROL ELECTRONIC MONITORING SYSTEM CONTROLLER

EX-RC1 Remote I/O Adapter

Model INSTRUCTION MANUAL DIGITAL MULTIMETER

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs

B&W RearView Camera Installation & Operation

Thread length (overall length) material

Resolver to Digital Expansion Board

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

Cylindrical Proximity Sensor

5 B&W Rear View System Camera

Technical Data Sheet OPUS A3 STANDARD Basic

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

MODBUS RTU I/O Expansion Modules - Models C267, C277, and C287. Installation and Operations Manual Section 50

INSTALLATION INSTRUCTIONS

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

TCNM-ACBB1 Installation Manual

User Manual Entry Line Industrial Fast Ethernet Switch 5x 10/100Base-TX

DX561 Digital Input/Output Module

Model 7705 Control Module

PowerFlex 400 AC Drive Guide Specification

PowerLogic High Density Metering System 1-Meter Enclosure

DC562, digital input/output module,

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

Model A Mini AC/DC Clamp Meter. User's Guide

Hall-Effect Paddle Joystick

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

IP Apartment System Quick Start Guide

IGLOO IGLOO EASY INSTRUCTION MANUAL

Magnetically Actuated Safety Interlock Switches

the Interactive Catalog

EX-RC1 Remote I/O Adapter

1.6. Counters, Panel Meters, Tachometers and Timers. Contents Description Fusion Integrated Machine Control Standards and Certifications...

Beacon Power Supply Operating and Installation Instruction Manual

PV Rapid Shutdown device

DC 2-wire Cylindrical Inductive Proximity Sensor

CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application

User Manual Entry Line Industrial Gigabit Ethernet High Power 60/95 W PoE Injector

Model 2657A-LIM-3 LO Interconnect Module

Quick Start Guide. SEB-710 I/O Expansion board. Introduction

Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC

Safegard V4 Panel. Installation Datasheet. Safegard V4 Panel Installation Instructions and Datasheet release 1.7 August 2016

ASI Systems ML5740A Series

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

ASI Systems ML5720A Series

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

RXTH DUAL ROOM SENSOR / SWITCH

CVU-3K-KIT. 3 kv Bias Tee Kit. Description. Parts list / October 2014 *P * 1

V E1B Snap-in I/O Module

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

P/N: AX Applications: power gen set engine control systems oil and gas equipment automation off-highway machine automation

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data:

GX-5SU(B) is just 5.4 mm 0.213in in diameter, the smallest in existing DC two-wire sensors. It saves you space.

MODEL: R1M-D1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

IO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation Systems 1

Manual# Installation Manual. 200E Series. DCU 210E/208E Engine Panel RP 210E/220E Remote Panel

DC561, digital input/output module,

EP/2 Installation Instructions

A Axis M-Functions Level 1 A Axis Standard A Axis SMT Level 2. Each console includes the following:

S7999D SOLA Operator Interface Display

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

TEC100 USER/INSTALLER MANUAL V2.0 REV. 03/2018

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

SORDS ELECTRIC ~ MA7200. Sensorless Vector AC Inverter.

E101 - Strain Gauge Transducer Display Module. Contents

SMI-100 Stack Monitoring Interface Installation & Operation Manual

User Manual. cmt-iv5 Startup Guide

This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens).

Rotary Measurement Technology Absolute Encoders, Singleturn

DI561 Digital Input Module

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

1 Description. 2 Specifications. Product Installation Document. Honeywell 12 Clintonville Road Northford, CT

Transcription:

PowerCore Model TEC-10 Installation Manual Products covered in this document comply with European Council electromagnetic compatibility directive 2014/30/EU and electrical safety directive 2014/35/EU. 00-02-0977 2018-02-23 Section 30

In order to consistently bring you the highest quality, full-featured products, we reserve the right to change our specifications and designs at any time. The latest version of this manual can be found at enovationcontrols.com. BEFORE BEGINNING INSTALLATION OF THIS MURPHY PRODUCT: Read and follow all installation instructions. Visually inspect this product before installation for any damage during shipping. Disconnect all electrical power to the machine. Failure to do this before welding can result in damage to the panel and/or its components. It is your responsibility to have a qualified technician install the unit and make sure the installation conforms to local codes including, but not limited to, double insulation and fire containment. Observe all Warnings and Cautions in each section of these instructions. The TEC-10 is designed for use in industrial environments for monitoring and control which include engine driven pumps, compressors, grinders, chippers and rock crushers. Potential difficulties may exist when ensuring electromagnetic compatibility in other environments due to conducted as well as radiated disturbances. Contact Enovation Controls Technical Service if you have any questions or concerns at: +1 918-317-4100. IMPORTANT! Improper use and operation of electronic products can be dangerous. It is required that point-ofoperation guarding devices be installed and maintained. All such devices must meet OSHA and ANSI Machine safety standards. The manufacturer shall not accept any responsibility for installation, application or safety of systems.

Table of Contents Operations Manual Location... 2 Hardware Installation... 2 Inspecting Package Contents... 2 Tools Needed... 2 Installation... 3 Dimensions for Installation... 4 PIN Specifications... 6 Accessories... 7 Specifications... 8 Interface... 8 Power Supply... 8 Inputs (9)... 8 Outputs (8)... 8 Communications... 8 Mating Connectors... 8 Physical / Environmental... 8

The TEC-10 can be set as an AutoStart Controller. Please be cognizant at all times of hands and other objects that are in close proximity to the machine(s) being controlled as they may commence operation suddenly and without warning. LENS CLEANING PROCEDURES The lens on the TEC-10 is composed of Polycarbonate materials. Use only mild soap and water to clean the lens/display window. Evidence of improper cleaning techniques or chemicals includes cracks, smear marks, scratches, or fogged/hazy lenses. 2018-02-23-1 -

Operations Manual Location After installation, please review the TEC-10 Operations Manual prior to placing the controller into service. In order to access the TEC-10 Operation Manual, please visit: support.enovationcontrols.com Then search for TEC-10. Download the latest manual by clicking the link under the Manuals section of the page. Hardware Installation Inspecting Package Contents Before attempting to install the product, it is recommended that you ensure all parts are accounted for and inspect each item for damage (which sometimes occurs during shipping). The items included in the box are: TEC-10 Controller kit P/N 40-70-0495 includes: TEC-10 Control Panel Mounting Kit: o o 4 Shockmount Isolators 4 ¼ x 20 Hex Keps Nuts TEC-10 Installation Manual P/N 00-02-0977 Tools Needed Use a 9/32 or 7.5mm drill bit to make the approximately sized 0.28125 or 7.5mm mounting holes. Use a 7/16 or 11mm torque wrench for shockmount nut installation. 2018-02-23-2 -

Installation Preparing the Enclosed Panel Determine the location of the TEC-10 Panel on the customersupplied mounting bracket or plate. The suitability of the location is subject to investigation by the local authority having jurisdiction at the time of the installation. Recommended torque for tightening both the shockmounts into the panel and the nuts on the shockmounts is 78 inch-pounds or 8.8 Nm (Newton Meters). Although thread lock is not required, only blue polycarbonate compatible thread lock should be used for the TEC-10 mounting screws. 2018-02-23-3 -

Dimensions for Installation Front Inches [mm] Side View 2018-02-23-4 -

Back View 2018-02-23-5 -

PIN Specifications PIN 21 Pin Connector (A) PIN 31 Pin Connector (B) A Unavailable 1 Unavailable B Battery (positive) 2 Unavailable C Unavailable 3 Unavailable D Relay 1, +DC (10A), Default Setting: Crank 4 Unavailable E Battery (negative) 5 Unavailable F J1939 CAN Shield 6 Unavailable G Relay 2, +DC (10A), Default Setting: ECU Enable 7 Unavailable H Unavailable 8 Unavailable J Alternator Excite Output, +DC (1A) 9 Analog Input 3, Default Setting: Not Used K Unavailable 10 Unavailable L Unavailable 11 Unavailable M Unavailable 12 Unavailable N Unavailable 13 Digital Output 1, +DC, (1A), Default Setting: Not in Auto) P Unavailable 14 Digital Input 3, Default Setting: Dual Contact Stop, R S Digital Output 3, -DC, (1A), Default Setting: Throttle Decrease) Digital Output 4, -DC, (1A), Default Setting: Throttle Increase B- 15 Unavailable 16 Unavailable T Frequency Input 17 Relay 3 Common (RLY 3 Defaulted to Not Used) U V J1939 CAN Low (includes terminating resistor, Default to ON) J1939 CAN High, (includes terminating resistor, Default to ON) 10A Max 18 Relay 3 NC (RLY 3 Defaulted to Not Used) 10A Max 19 Relay 3 NO (RLY 3 Defaulted to Not Used) 10A Max W Analog Input 2, Default Setting: Not Used 20 Digital Input 5, Default Setting: Low Lube Oil Level B- X Analog Input 1, Default Setting: Not Used 21 Digital Input 1, Default Setting: Not Used NOTE: Wiring of this device must meet all applicable electrical codes. 22 Unavailable 23 Digital Input 2, Default Setting: Dual Contact Start, B- 24 Digital Output 2, +DC, (1A), Default Setting: Engine Running) 25 Unavailable 26 Battery (negative) 27 Unavailable 28 Unavailable 29 Digital Input 4, Default Setting: Low Coolant Level, B- 30 RS485 (positive) 31 RS485 (negative) 2018-02-23-6 -

Accessories Part Description Number 40000602 Engine Harness, 21 Position Connector 10 Whip Harness (3m approx.) 40000603 I/O Harness, 31 Position Connector 10 Whip Harness (3m approx.) 40000479 Deutsch Connector Kit, 21-pin and 31-pin, Panel Connector Kit 40000531 Deutsch Connector Kit, 21-pin, Panel Connector Kit, Engine Only 78700046 Deutsch Connector Kit, 31-pin, Panel Connector Kit, I/O Only 40051073 Replacement Fuse Door 40051143 Replacement Fuse Door Pad 40000601 Replacement Shock Mount Kit 40000636 Replacement Key Set 40000625 TEC-10 Programming Kit 2018-02-23-7 -

Specifications Interface Display: Monochrome HR-TFT with backlight 2.7 / 68 mm, WQVGA (400 x 240 pixels) Languages: English, Spanish, German, French, Italian (3) LEDs: Green (mode), Yellow (warning) and Red (shutdown) Operator Controls: (11) Raised silicone keypads, tactile feedback (1) Rotary key switch, power on/off (1) Push switch (red), engine stop Power Supply Operating Voltage: 8-32 VDC, reverse battery polarity and load-dump protected Cranking Power Holdup: 0 VDC up to 50mS (also good for brownout / blackout instances) Current Consumption: Power on in stopped state; 117 ma at 12 VDC. Power on in standby mode; 52 ma at 12 VDC Inputs (9) (5) Digital: configurable (active on High, Low, Open) (3) Analog: configurable (4-20 ma, 0-5V, resistive or digital ground) (1) Frequency: supporting: Magnetic Pickup (30 Hz 10 khz, 2.0 VAC 120 VAC) and Engine Alternator (30 Hz 10 khz, 4.5 VRMS 90 VRMS) Outputs (8) (2) Relay: switched +DC, 10A (1) Relay: Form C (dry / volt-free), 10A (2) Low-side FET: (-DC), 1A (2) High-side FET: (+DC), 1A (1) Dedicated Alternator Excitation: +DC, 1A Communications (1) CAN: J1939 (1) RS485: Modbus RTU Mating Connectors 21 Position, Deutsch HDP26-24-21SE 31 Position, Deutsch HDP26-24-31SE Physical / Environmental Enclosure material: Polycarbonate Dimensions (WxHxD): 9.59 x 7.34 x 5.20 in. (243.48 x 186.5 x 132.23 mm) Weight: 4 lbs (1.8 kg) IP Rating: IP67 Operating and Storage Temperature: -40 to +85 C (-40 to 185 F) Vibration: 7.86 G rms (5-2000 Hz), 3-axes random Shock: ±50G, 3-axes 2018-02-23-8 -