INCOM communications adapter module

Similar documents
Time delay undervoltage module

Series NRX drawout circuit breaker and cassette rejection interlocks

COOPER POWER SERIES. Input/Output (I/O) module installation instructions. Voltage Regulators MN225067EN

COOPER POWER SERIES. RS-485 digital communications accessory board installation and operation instructions. Voltage Regulators MN225074EN

COOPER POWER SERIES. 600 A U-OP visible break connector system operation instructions. Deadbreak Apparatus Connectors MN650022EN

Power Xpert Meter 350 (PXM350) three-phased DIN-rail multifunction meter

Digitrip 520MC with Maintenance Mode

Multi Unit Enclosed Meter

COOPER POWER SERIES. Visible-Break switch accessory operation instructions. Padmounted switchgear MN285011EN

Instructions for Testing Magnum DS Trip Units Using PACB Test Kit Styles 87C0270G01-G03

COOPER POWER SERIES. DC motor operator control installation and operation instructions. Padmounted Switchgear MN285018EN

Power Xpert Meter 2000 Series

COOPER POWER SERIES. Fiber-optic/RS-232 communications module installation and operation instructions. Voltage Regulators MN225020EN

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2

Eaton Innovative TechnologyT XT50/100 surge protective device

E-Series Troubleshooting Guide

COOPER POWER SERIES. Ethernet communications module installation and operation instructions. Voltage Regulators MN225033EN

for the SPV Installation and Operation Manual Instruction Manual IM E Contents

Cutler-Hammer. Westinghouse Transfer Switch Equipment. IQ Transfer

INSTRUCTIONS FOR THE IQ DC POWER SUPPLY INSTRUCTION LEAFLET IL E

Instructions for installation, operation and maintenance of the Arc Quenching Device (AQD)

LP800 Loop Tester. Installation and Operation Manual

Installer Guide. About SecureConnect. Contents. About this guide. Eaton SecureConnect. About the web portal

COOPER POWER SERIES. Form 4C microprocessor-based recloser control standard and automation power supply kit installation and operation instructions

PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY

ALPHA Plus and A3 ALPHA Switchboard Meters with the CPS Power Supply

DeviceNet Master (Scanner) HE800DNT450 / HE-DNT450* DeviceNet Communications * HE- denotes plastic case.

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

PM Series Power Meter

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Single Phase Vacuum Capacitor Switch. UltraVacLT 15kV 95kV or 125kV BIL

CSM_PYF S/P2RF- -S_DS_E_2_5

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

iconverter 2-Module Power Chassis

COM32. Installation & Operation Manual

MN150004EN E-Allocation Software User Guide. Effective July 2017 Supercedes October 2016

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

H704-42(H)(E), H704-42/1(H)(E)

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS

Remote I/O Scanner. Catalog Number 1747-SN. Installation Instructions. Publication

SIMADYN D Digital Control System. Fiber-Optic Rack Coupling CS12. User Manual. Edition DK No

Serial Communications Accessories SITRANS RD200/300. Operating Instructions 05/2013 SITRANS

CAN Fiber Optic Modem

FLEX Ex Spring Clamp Terminal Base

Wallstations for use with Grafik 3000 and 4000 Series Systems

Installation & Operation Guide

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2

High Speed Remote I/O Module

EX-RC1 Remote I/O Adapter

Shutter and rail locking device for low-voltage switchgear

S82S (3/7.5-W Models)

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

MicroTech III Water Source Heat Pump BACnet MS/TP Communication Module

22 Digital Inputs, including 2 Analog, 2 HSC/Shaft-encoder inputs 16 Transistor Outputs

Contents. HP E1586A Rack Mount Terminal Panel User s Manual

NE1A-SCPU Series. Safety Network Controller. Achieve Safety Control through Programming. Ordering Information. Specifications.

PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

Soft Starter Remote Operator. Section 1.0 Introduction 1.1 Important user information General Manual description...2.

Vision OPLC V TR6/V350-J-TR6

Instruction Leaflet IL EN Series NRX with PXR - instructions for PROFIBUS DP communications adapter module (PCAM)

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

RS-485 Fiber-Optic Link RS-485 to Multi-Mode Fiber-Optic converter ST Fiber Connectors DIN Rail Mount

500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System

INSTALLATION MANUAL SLI 50 INVERTER

PowerLogic High Density Metering System 1-Meter Enclosure

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

Install Motor Controller User Manual

Tempco Instruction Manual

Vapor Monitor Interface Module

Digital ac/dc (24V) Input Module

DTS 310. DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter. Page 1. Measurlogic MQ A

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L MONITORED DEVICE

EDR-3000 Eaton Distribution Relay

INSTALLATION INSTRUCTIONS

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

SPiiPlusEC Network Manager Installation Guide November2014 Document Revision: 02

WR-5e Remote Control

Instruction Bulletin

Agilent OBSAI Protocol Tester

Serial PROFIBUS Interface

Zonit μats TM Users Guide μats1-lv Version 1.2

Acoustic Design Series

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Digitrip 1150 with Maintenance Mode

PIM-Mini Pulsed Current Source Operation Manual

Cutler-Hammer. Instructions for Installation, Operation and Maintenance of Cutler-Hammer IQ Analyzer Electrical Distribution System Monitor TD 17530A

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1

Eaton SPD Series. for Mounting External to Electrical Distribution Equipment. Instruction Manual IM E Effective March 2014 Rev.

MicroTech III Applied Terminal Systems BACnet MS/TP Communication Module

User Manual for XL-J1939

PGR-6100 MANUAL GROUND-FAULT & INSULATION MONITOR

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Digital Lighting Systems, Inc. PD216. Two Channel Dimmer and Switch Packs PROTOCOL USER'S MANUAL. PD216-UM Rev. E - 02/03

Transcription:

Instruction Leaflet IL0131124EN Supersedes July 2016 INCOM communications adapter module Power Defense ICCB Instructions apply to: UL489 : PD-NF UL489 : PD-RF IEC : PD-NF, IZMX16 IEC : PD-RF, IZMX40 WARNING (1) ONLY QUALIFIED ELECTRICAL PERSONNEL SHOULD BE PERMITTED TO WORK ON THE EQUIPMENT. (2) ALWAYS DE-ENERGIZE PRIMARY AND SECONDARY CIRCUITS IF A CIRCUIT BREAKER CANNOT BE REMOVED TO A SAFE WORK LOCATION. (3) DRAWOUT CIRCUIT BREAKERS SHOULD BE LEVERED (RACKED) OUT TO THE DISCONNECT POSITION. (4) ALL CIRCUIT BREAKERS SHOULD BE SWITCHED TO THE OFF POSITION AND MECHANISM SPRINGS DISCHARGED. FAILURE TO FOLLOW THESE STEPS FOR ALL PROCEDURES DESCRIBED IN THIS INSTRUCTION LEAFLET COULD RESULT IN DEATH, BODILY INJURY, OR PROPERTY DAMAGE. WARNING THE INSTRUCTIONS CONTAINED IN THIS IL AND ON PRODUCT LABELS HAVE TO BE FOLLOWED. OBSERVE THE FIVE SAFETY RULES: DISCONNECTING ENSURE THAT DEVICES CANNOT BE ACCIDENTALLY RESTARTED VERIFY ISOLATION FROM THE SUPPLY EARTHING AND SHORT-CIRCUITING COVERING OR PROVIDING BARRIERS TO ADJACENT LIVE PARTS DISCONNECT THE EQUIPMENT FROM THE SUPPLY. USE ONLY AUTHORIZED SPARE PARTS IN THE REPAIR OF THE EQUIPMENT. THE SPECIFIED MAINTENANCE INTERVALS AS WELL AS THE INSTRUCTIONS FOR REPAIR AND EXCHANGE MUST BE STRICTLY ADHERED TO PREVENT INJURY TO PERSONNEL AND DAMAGE TO THE SWITCHBOARD. Power Defense

Section 1: General information The INCOM Communications Adapter Module (ICAM) (Figure 1) is an accessory that will operate as a communicating device in conjunction with a compatible trip unit/breaker in a master communications network (Figure 2). Figure 1. (ICAM). Master device Communications network The INCOM network sends a burst of data as a 92-115.2 khz carrier signal at a 9600 baud rate over twisted pair conductors to interconnect the many devices comprising the network. These bursts of data can be captured and used in a variety of ways depending upon the manner in which the master computer program is configured. For example, all the settings can be viewed via the master computer. Also, the data for the individual phase current values is available on the network. The software will select the appropriate data, decode it, and display it in a useful manner. Following an overcurrent trip operation, the cause of trip, the value, and the phase or ground current responsible for the trip are available on the network. The is a slave device and, as such, requires a master device for control command initiation. Each provides: Circuit breaker Open/Close/Reset control; Flashing status LED, indicating the module has power; INCOM communication Enable/Disable selection jumper for remote Open/Close control; DIN rail mounting (11 mm H, 28 mm W, DIN rail minimum requirement); Input power for module from 24 Vdc. The is designed to be installed, operated, and maintained by adequately trained people. These instructions do not cover all details or variations of the equipment for its storage, delivery, installation, checkout, safe operation, or maintenance. If you have any questions or need additional information or instructions, please contact your local Eaton representative or visit www.eaton.com. ICAM module 1 ICAM module 2 ICAM module 3 breaker breaker breaker Figure 2. s in an INCOM network. 2

STATUS TRANSMIT RECEIVE SOURCE GROUND - Enable - Disable INCOM Control Section 2: Installation of remote mount CAM module adapter This section illustrates the proper installation of the adapter for remote mounting of the CAM module. Table 1. Kit contents. Qty. Item 1 Adapter harness CAM module to breaker secondary 1 Ferrule 2-18 AWG (Weidmuller PN 9004310000) 1 Installation instructions This kit does not include the DIN rail for mounting the CAM module. This kit provides an additional cable adapter for connection from the communications adapter module (CAM) to the circuit breaker when the CAM needs to be mounted remotely such as with a fixed mount circuit breaker (see Figure 3). The adapter consists of a 1 m (3 ft.) length of cable that connects between the CAM module and the breaker secondary. The CAM module should be mounted on a length of standard grounded DIN rail. INCOM Communications Adapter Module CAT.ICAM + NP66A1559H01 + 1 meter cable length Unpopulated plugs 19 +24 V 25 CMM1 27 CMM3 AGND 20 CMM2 26 CMM4 28 Figure 3. Connection of adapter cable to the circuit breaker. 3

The numbered flags on each wire of the cable directly correspond with the breaker secondary terminal designators. When connecting the adapter to the CAM module, ensure the unpopulated plugs are positioned on the left hand side as indicated in Figure 4. Note that the CAM module connector is keyed to fit in only one orientation. Section 3: Basic wiring rules The following basic rules apply given a system consisting of a single daisy-chained main cable link between master and slave devices (Figure 2). For more complex considerations including star configurations, please refer to the INCOM wiring specification TD17513. 1. Recommended cable specifications: Eaton cable catalog #IMPCABLE, Style #2A95705G01; Belden 9463 cable family; Identical Commscope or Quabbin cables. 2. The maximum system capacity is 10,000 ft. (3048 m) of communications cable and 1,000 slave devices. 3. Non-terminated taps, up to 200 ft. (61 m) in length, off the main link are permitted, but add to the total cable length. Unpopulated plugs Figure 4. Connection to the CAM module. 4. Make sure there is a twisted wire pair present that is intended for INCOM network use. Use shielded twisted pair wire to connect each slave device to the INCOM network, daisy-chain style. The polarity of the twisted pairs is not important. 5. Ferrules for use in double connection point daisy-chain wiring are available (Weidmuller part 9004310000 [2-#18 AWG]). The drain wire may be connected to the SHIELD terminal on the MCAM or the ICAM. Or it may be connected to the grounded DIN rail. If a PCAM or ECAM module is used use the 2-18 AWG ferrule provided to connect the cable drain wire for a proper connection to the power supply ground terminal as shown in Figure 5. Figure 5. Connection to the CAM module. 4

Section 4: INCOM communications adapter module connections WARNING ALL APPLICABLE SAFETY CODES, SAFETY STANDARDS, AND SAFETY REGULATIONS MUST BE STRICTLY ADHERED TO WHEN INSTALLING, OPERATING, OR MAINTAINING THIS EQUIPMENT. FAILURE TO COMPLY COULD RESULT IN DEATH, BODILY INJURY, OR PROPERTY DAMAGE. For installation specifics, refer to Figures 7 and 8 on pages 6 and 7 respectively for wiring diagrams, as well as pin-out Table 2 (Power connector) and Table 3 (INCOM connector) on this page. Section 5: Jumpers and indicator LEDs Refer to Figure 6 to become familiar with specific jumper and LED locations on the. Status LED Table 2. Power connector pin-outs 1. Pin number Input signal 1 24 Vdc + 2 24 Vdc 3 Control signal common 4 Control open signal 5 Control close signal 1 Module power uses a 5-pin input connector. Power requirement is 24 Vdc, 10 watts. Jumper plug for source testing (Not functional for PXR trip units) Jumper plugs for communication control Table 3. INCOM connector pin-outs 1. Pin number Input/output signal 1 INCOM carrier network 2 INCOM carrier network 3 Shield 1 Connect shield wire to ground at master device only. Interconnect shielding where devices are daisychained. Figure 6. (front view, close up). Microcontroller LED (status) This indicator will be flashing green whenever the module is powered up and when the microprocessor is executing instructions. When the is connected to a PXR for the first time, this LED will alternately flash red and green to signal a learning process between both units. This automatic process will take approximately 15 seconds and occurs only once during the initial startup. The LED will also flash red if the module is not connected to or unable to communicate with a PXR trip unit. INCOM control jumper This jumper provides the user with a means of enabling or disabling remote communication control commands to the PXR trip unit. With jumper placed in the ENABLE position, remote slave action commands, such as Open and Close, can be acted upon. With the jumper in the DISABLE position, commands will not be accepted. Source/residual ground selection jumper This jumper is not applicable and does not function for PXR style trip units. The source/residual ground setting is programmed via the PXR trip unit front panel display 5

6 5 100 ohms Comm control 25 26 27 28 circuit breaker PXR The communications module is a separate device that snaps onto a remote mounted DIN rail. The trip unit auxiliary voltage is 24 Vdc ±10% and should be sourced from a reliable service, with 10 watt capability. INCOM communication cable is a two conductor with shield type wire in daisy chain configuration. The recommended cable (Belden # 9643 or equivalent) has a twisted-pair of wires (#20 AWG stranded 7 x 28 conductors with PVC insulation) having an aluminum/mylar foil shield with drain wire. The polarity of the twisted-pair is not important. Ground the shield at the host computer (device). Set the jumper on the module to enable or disable the remote open and close communication control commands, as desired. Connectors are UL /CSA rated 300 V, VDE rated 250 V. Recommended: (BL 3.5/90/5BK) Orientation: 90 lead exit, but other lead orientations are possible. Wire gauge: #18 AWG/0.82 mm. The final device in the daisy-chain configuration must have a 100 ohms termination resistor installed across terminals #1 and #2 on TB #2. Figure 7. INCOM communication with PXR 20/25. 6

Optional external contacts l 35 36 m k j Communications module Circuit breaker j Choose spring release coil voltage rating as desired if communications is required. k Choose shunt trip rating to be the same as spring release rating if communication is required. l Control power rating must match ST and SR coil rating. m Close duration is two seconds on communication activation when communications control is enabled. Figure 8. Spring release and shunt trip wiring as shown for optional communication close or open capability. 7

Section 6: Viewing/setting INCOM address The PXR 20/25 trip unit is used as the means to display and modify the programmed INCOM address setting of the ICAM module. All modules are shipped with a factory set default address of 4094. The allowable address range is 0001-4094. A trip unit containing a full display, such as the PXR 20 or PXR 25, will provide the ICAM settings in menu form. To set or view ICAM settings on a PXR 20 or PXR 25 limited display, the following sequence is used. To set or view the address and baud rate, go to the "Settings - Communications - INCOM CAM" menu on the PXR trip unit. A PXR trip unit display screen is shown in Figure 9. For the PXR, two communication settings are available and can be viewed as shown in Table 4. Section 7: Network communication protocols The INCOM communication for the INCOM communications adapter module is based on a master (PC, communicating trip unit, etc.) - slave () set of protocols. For more comprehensive information on the INCOM communications adapter module communication protocol, please see the following reference material: IL17384 - Part A: INCOM Communications Standard Figure 9. PXR trip unit INCOM settings screen. Table 4. ICAM communications setting ranges. Allowable range Communication address 001 4094 Baud rate 9600 8

Section 8: Troubleshooting The most common issues experienced with the installation of a are addressed below. If you have additional questions or need further information and/or instructions, please contact your local Eaton representative or visit www.eaton.com. Observation 1 - Status LED not flashing. Action - Verify proper input power to the module connectors. Observation 2 - Status LED flashing green, but module does not change state in response to master command requests. Action - Verify correct module address. Action - Verify communication cable is connected correctly from master to module. 9

Disclaimer of warranties and limitation of liability The information, recommendations, descriptions, and safety notations in this document are based on Eaton Corporation s ( Eaton ) experience and judgment, and may not cover all contingencies. If further information is required, an Eaton sales office should be consulted. Sale of the product shown in this literature is subject to the terms and conditions outlined in appropriate Eaton selling policies or other contractual agreement between Eaton and the purchaser. THERE ARE NO UNDERSTANDINGS, AGREEMENTS, WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, OTHER THAN THOSE SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES. ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON. THE CONTENTS OF THIS DOCUMENT SHALL NOT BECOME PART OF OR MODIFY ANY CONTRACT BETWEEN THE PARTIES. In no event will Eaton be responsible to the purchaser or user in contract, in tort (including negligence), strict liability, or otherwise for any special, indirect, incidental, or consequential damage or loss whatsoever, including but not limited to damage or loss of use of equipment, plant or power system, cost of capital, loss of power, additional expenses in the use of existing power facilities, or claims against the purchaser or user by its customers resulting from the use of the information, recommendations, and descriptions contained herein. The information contained in this manual is subject to change without notice. Eaton Electrical Sector 1000 Eaton Boulevard Cleveland, OH 44122 United States 877-ETN-CARE (877-386-2273) Eaton.com 2019 Eaton All Rights Reserved Printed in USA Publication No. IL0131124EN / LNT14 Part Number: IL0131124ENH02 January 2019 Eaton is a registered trademark. All other trademarks are property of their respective owners.