SIMATIC HMI. WinCC WinCC Runtime Advanced readme. Security information 1. Installation 2. Runtime 3. System Manual. Online help printout

Similar documents
Readme SiVArc V14 SP1 Update 6

SIMATIC. Process Control System PCS 7 Configuration McAfee Endpoint Security Security information 1. Preface 2.

Team engineering via Inter Project. Engineering. TIA Portal. Team engineering via Inter Project Engineering. Basics of "Inter Project Engineering"

SIMATIC. PCS 7 Process Control System SIMATIC Logon Readme V1.6 (Online) Security information 1. Overview 2. Notes on installation 3.

SIMATIC. TIA-Portal SIMATIC Visualization Architect. Security information 1. Basics 2. Installation 3. Elements and basic settings 4

SIMATIC. Process Control System PCS 7 Configuration Symantec Endpoint Protection V14. Security information 1. Preface 2.

Siemens Industrial SIMATIC. Process Control System PCS 7 Configuration Trend Micro OfficeScan Server XG. Security information 1.

SIMATIC. PCS 7 Licenses and configuration limits (V9.0) Security information 1. Preface 2. Selecting the correct license keys 3

SIMOCODE pro. Read me SIMOCODE ES. Introduction 1. Installation notes 2. Installation/License key/ Uninstallation 3.

SIMATIC. WinCC Readme Runtime Professional. Validity 1. Improvements in Update 7 2. Improvements in Update 6 3. Improvements in Update 5 4

SIMATIC. Process Control System PCS 7 VT Readme V8.2 (online) Security information 1. Overview 2. Notes on Installation 3. Notes on usage 4.

Creating the program. TIA Portal. SIMATIC Creating the program. Loading the block library 1. Deleting program block Main [OB1]

Siemens Drives & PLCs

SIMATIC. Process Control System PCS 7 CFC Readme V9.0 (online) Security information 1. Overview 2. Notes on Installation 3. Notes on usage 4.

SIMATIC. Industrial PC Microsoft Windows 7 (USB stick) Safety instructions 1. Initial startup: Commissioning the operating system

SIMATIC. SIMATIC Energy Manager V1.0 App for ios and Android. Preface. SIMATIC Energy Manager app. Establish connection to SIMATIC Energy Manager PRO

SIMATIC. Process Control System PCS 7 Advanced Process Functions Operator Manual. Preface. Security information 1. Overview 2. Material management 3

SIMATIC. Process control system PCS 7 Operator Station (V9.0 SP1) Security information 1. Preface 2

SIMATIC. WinCC Readme Runtime Professional. Validity 1. Improvements in Update 2 2. Improvements in Update 1 3

PD PA AP How To Configure Maxum II TimeServer Access

SIMATIC NET. Industrial Ethernet / PROFINET Primary Setup Tool (PST) Preface. Functions 1. Software installation 2. Operation. Configuration Manual

SIMATIC NET. Industrial Ethernet Security SCALANCE S615 Getting Started. Preface. Connecting SCALANCE S615 to the WAN 1

SIMATIC. Industrial PC Microsoft Windows 7. Safety instructions 1. Initial startup: Commissioning the operating. system

SIMATIC. Process Control System PCS 7 PCS 7 system documentation - Readme V8.0 SP2 (Update 1) Options for Accessing Documentation 1

SIMATIC NET. Industrial Remote Communication - Remote Networks SINEMA Remote Connect - Client. Preface. Requirements for operation 1

SIMATIC. S7/HMI SIMATIC Automation Tool V3.1 SP1 product information. SIMATIC Automation Tool features 1. Known problems. Product Information

Optional package printer driver V1.4

SIMATIC NET. Industrial Remote Communication TeleService TS Gateway. Preface. Application and properties. Installation, commissioning and operation 2

Siemens Spares. Setting up security in STEP 7. Professional SIMATIC NET. Industrial Ethernet Security Setting up security in STEP 7 Professional

SIMATIC. Process Control System PCS 7 SIMATIC Management Console (V9.0) Security information 1. Preface 2. Basics 3

MindSphere. Visual Explorer. Introduction. User roles for "Visual Explorer" Connecting "Visual Explorer" to MindSphere data. Creating Visualizations

SIMATIC. Process control system PCS 7 PCS 7 - PC Configuration (V9.0 SP1) Security information 1. Preface 2. PC components of a PCS 7 system 3

SIMATIC. Industrial PC Microsoft Windows Embedded Standard 7. Safety instructions 1. Initial startup: Commissioning the operating.

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3 SIMATIC. Readme. Readme

SIMATIC. Process Control System PCS 7 Trend Micro OfficeScan (V8.0; V8.0 SP1) Configuration. Using virus scanners 1.

SIMATIC. WinCC Readme Runtime Professional. Validity 1. Improvements in Update 6 2. Improvements in Update 3 3. Improvements in Update 2 4

Industrial Controls. Motor management and control devices SIMOCODE pro - Application examples. Introduction 1. Application example

Industrial Controls. Motor management and control devices SIMOCODE pro. Introduction 1. Configuring a reversing starter. List of abbreviations

Commissioning PC Stations - Manual. and Quick Start SIMATIC NET. PC software Commissioning PC Stations - Manual and Quick Start.

SIMATIC. SIMATIC Logon V1.6. Security information 1. Conditions for secure operation of SIMATIC Logon 2. User management and electronic signatures 3

SIMATIC. Process Control System PCS 7 SIMATIC Management Console (V9.0 Update 1) Security information 1. Preface 2. Basics 3

SIMATIC/SINAMICS. Getting started with SINAMICS V90 PN on S Motion Control. Fundamental safety instructions 1. Introduction

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3 SIMATIC. Improvements in Openness 4. Readme. Readme

SIMATIC. Process Control System PCS 7 Symantec Endpoint Protection 11.0 Configuration. Using virus scanners 1. Configuration 2. Commissioning Manual

SIMATIC. STEP 7 PLUS TIA Portal Teamcenter Gateway. Introduction to TIA Portal Teamcenter Gateway 1. System requirements 2

SINEMA Remote Connect - Client SIMATIC NET. Industrial Remote Communication SINEMA Remote Connect - Client. Preface. Requirements for operation

SINETPLAN Siemens Network Planner

Getting Started - Startdrive. Startdrive SINAMICS. Introduction 1. Connecting the drive unit to the PC. Creating a project 3

SIMATIC. Process Control System PCS 7 OS Process Control (V8.1) Security information 1. Preface 2. Additional documentation 3

Class documentation. COMOSKDictionary COMOS. Platform Class documentation COMOSKDictionary. Trademarks. General. KDictionary. Programming Manual

SIMATIC. PCS 7 Process Control System Support and Remote Dialup. Security information 1. Preface 2. Support and Remote Dialup 3.

IO-Link Master (6ES7147-4JD00-0AB0) SIMATIC. ET 200pro IO-Link Master (6ES7147-4JD00-0AB0) Preface. Documentation guide. Product overview.

Performance data abgn SCALANCE W770/W730 SIMATIC NET. Industrial Wireless LAN Performance data abgn SCALANCE W770/W730.

COMOS. Platform Class documentation RevisionMaster_dll. Class: RevisionInfo 1. Class: RevisionMaster 2. Programming Manual

Performance data abgn PCIe Minicard MPCIE-R1-ABGN-U3 SIMATIC NET

SITOP UPS1600 under STEP 7 V13. SITOP UPS1600 under STEP 7 V13. Introduction. Safety notes. Description. Assigning the IP address

Industrial Controls. SIMOCODE pro SIMOCODE pro PCS 7 Library. Preface. Security information. Product specific security. information.

SIMATIC HMI. WinCC V11 WinCC Readme. General notes 1. Functional Constraints 2. Notes on use. Migration. Special considerations for Windows 7

SIMATIC Visualization Architect

SIMATIC. ET 200SP Open Controller Product information on CPU 1515SP PC. Preface. Product Information. Technical update. Technical specifications 3

Cycle and response times SIMATIC. S Cycle and response times. Preface. Documentation guide. Program processing 2. Cyclic program processing 3

SIMATIC HMI. WinCC V11 WinCC Readme. General information 1. Functional Constraints 2. Notes on use. Migration. Special considerations for Windows 7

SIMATIC. PCS 7 process control system OpenPCS 7 (V8.2) Security information 1. Preface 2. Basics 3. Installation and licensing 4. PCS 7 Engineering 5

Siemens Automation Products

party software COMOS Platform Third-party software Trademarks 1 Requirements for the system environment Third-party software releases Operating Manual

SIMATIC NET. Industrial Remote Communication - Remote Networks SINEMA Remote Connect. Preface. Connecting the SINEMA RC Server to the WAN 1

SIMATIC. Process Control System PCS 7 PCS 7 Documentation (V8.1) Options for Accessing Documentation 1. Documentation for the Planning Phase 2

Operator Station (V8.0) SIMATIC. Process Control System PCS 7 Operator Station (V8.0) Preface 1. The PCS 7 Operator Station

SIMATIC. PCS 7 Process Control System CFC Readme V9.0 SP2 Upd2 (Online) Security information 1. Overview 2. Notes on Installation 3.

SIMATIC HMI. WinCC V7.4 SP1 SIMATIC HMI WinCC V7.4 Getting Started. Welcome 1. Icons 2. Creating a project. Configure communication

RF-MANAGER simulator SIMATIC. RFID-Systems RF-MANAGER simulator. Simulating projects. Compact Operating Instructions 06/2010 A5E

SIMATIC. Process Control System PCS 7 OS Process Control (V8.1) Preface 1. Additional documentation 2. Functions of the PCS 7 OS in process mode 3

SIMATIC. S7-1500, ET 200SP, ET 200pro Structure and Use of the CPU Memory. Preface. Documentation guide. Memory areas and retentive memory

SINEMA server SIMATIC NET. Network management SINEMA server. Preface. Network management with SINEMA Server - introduction

Firewall Settings for SIMATIC B.Data

SIMATIC. Process Control System PCS 7 Software update with utilization of new functions. Security information 1. Preface 2.

SIMATIC HMI. Software RemoteOperate V2. Preface. Overview 1. Range of functions of the RemoteOperate software. Hardware and software requirements

Primary Setup Tool (PST) SIMATIC NET. Industrial Ethernet / PROFINET Primary Setup Tool (PST) Preface. Description. Software installation 2


SIMATIC. SIMATIC Logon V User management and electronic signatures 1. Hardware and Software Requirements 2. Scope of delivery 3.

S7-300 Getting Started - Commissioning a CPU 31xC: Closed-loop control

SIMATIC. Information Server 2014 SP2 SIMATIC Information Server. Information Server - Installation Notes 1. Information Server - Release Notes

SIMATIC NET. Network management SINEMA Server. Preface. Network management with SINEMA Server - introduction

SIMATIC. Process Control System PCS 7 SFC Visualization (V9.0 SP2) Security information 1. What's new in SFV? 2. SFC Visualization (SFV) 3

SIMATIC. PCS 7 Web Option for OS (V8.2) Security information 1. Preface 2. Overview of the Web Option for OS 3. Additional documentation 4

SIMATIC. Process Control System PCS 7 Licenses and quantity structures (V8.0) Preface 1. Selecting the correct license keys 2

SIMATIC HMI. WinCC V7.4. WinCC/Calendar Options. Calendar Options overview 1. WinCC/Calendar Options. Installation Notes 2

SIMATIC IPC Wizard for. Widescreen devices with multitouch SIMATIC. Industrial PC SIMATIC IPC Wizard for. Preface.


SIMATIC. Process Control System PCS 7 Help for SIMATIC PDM (V9.1) Security information 1. Preface 2. Using SIMATIC PDM 3.

Class: DocumentManager 1 COMOS. Platform Class documentation DocumentManager_dll. Programming Manual 03/2017 V10.2.

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

SIMATIC HMI. WinCC V7.4 SP1 WinCC/Audit. WinCC/Audit - Installation Notes 1. WinCC/Audit - Release Notes 2. WinCC/Audit - Documentation.

Configuration limits for products of the SIMATIC NET PC Software V8.1 SIMATIC NET

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

Key Panels Library SIMATIC HMI. Key Panels Library. Preface 1. Installation of Key Panels Library. Working with the Key Panels Library

SIMATIC. PCS 7 process control system OpenPCS 7 (V8.1) Preface 1. Basics 2. Installation and licensing 3. PCS 7 Engineering 4. System configurations 5

Siemens Spares SIMATIC NET. Industrial Remote Communication - TeleControl TeleControl Server Basic. Preface. Application and functions

SIMATIC. Process Control System PCS 7 Compendium Part D - Operation and Maintenance (V8.2) Security information 1. Preface 2

SIMATIC. PCS 7 process control system OpenPCS 7. Preface 1. Basics 2. Installation and licensing 3. PCS 7 Engineering 4. System configurations 5

Transcription:

Security information 1 Installation 2 SIMATIC HMI Runtime 3 WinCC System Manual Online help printout 12/2017 Online help printout

Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION indicates that minor personal injury can result if proper precautions are not taken. NOTICE indicates that property damage can result if proper precautions are not taken. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems. Proper use of Siemens products Note the following: Trademarks WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed. All names identified by are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens AG Division Digital Factory Postfach 48 48 90026 NÜRNBERG GERMANY Document order number: Online help printout P 12/2017 Subject to change Copyright Siemens AG 2017. All rights reserved

Table of contents 1 Security information...5 2 Installation...11 3 Runtime...13 3.1 Notes on operation in Runtime...13 3.2 Notes on operation of Runtime Advanced...15 3.3 Communication...15 Index...17 System Manual, 12/2017, Online help printout 3

Table of contents 4 System Manual, 12/2017, Online help printout

Security information 1 Security information Siemens provides products and solutions with industrial security functions that support the secure operation of plants, systems, machines and networks. In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement and continuously maintain a holistic, state-of-the-art industrial security concept. Siemens products and solutions only form one element of such a concept. Customer is responsible to prevent unauthorized access to its plants, systems, machines and networks. Systems, machines and components should only be connected to the enterprise network or the internet if and to the extent necessary and with appropriate security measures (e.g. use of firewalls and network segmentation) in place. Additionally, Siemens guidance on appropriate security measures should be taken into account. For more information about industrial security, please visit http://www.siemens.com/industrialsecurity (http://www.industry.siemens.com/topics/global/ en/industrial-security/pages/default.aspx) Siemens products and solutions undergo continuous development to make them more secure. Siemens strongly recommends to apply product updates as soon as available and to always use the latest product versions. Use of product versions that are no longer supported, and failure to apply latest updates may increase customer s exposure to cyber threats. To stay informed about product updates, subscribe to the Siemens Industrial Security RSS Feed under http://www.siemens.com/industrialsecurity Passwords Various passwords are set by default in WinCC. For security reasons, you should change these passwords. On HMI devices with version V11 or V12, the password "100" is preset for the Sm@rtServer and for the integrated Web server. A default password is not preset for HMI devices with version V13. For the user "Administrator", the default password is "administrator". Integrated Web server It is always possible on a PC to access HTML pages in Runtime, even though the option"html pages" is disabled. Setup always installs the standard pages of the Web Server on the PC. Assign an administrator password to prevent unauthorized access to the pages. System Manual, 12/2017, Online help printout 5

Security information Communication via Ethernet In Ethernet-based communication, end users themselves are responsible for the security of their data network. The proper functioning of the device cannot be guaranteed in all circumstances; targeted attacks, for example, can lead to overload of the device. Use of SSL 3.0 For security reasons, the use of the protocol SSL 3.0 is not recommended. The use of the protocol SSL 3.0 is disabled by default on Comfort Panels. If you nevertheless wish to activate the use of SSL 3.0, select the option "Use SSL 3.0" in Internet Explorer or in "Start Center > Settings" under "Internet options > Advanced". For RT Advanced, the use of SSL 3.0 can be disabled in Internet Explorer or in the Control Panel under "Internet Options > Advanced" by deactivating the "Use SSL 3.0" option. Network settings WinCC Advanced (without simulation) Name The following tables show the network settings of each product which you need in order to analyze the network security and for the configuration of external firewalls: Port number Transport protocol ALM 4410* TCP Inbound, Outbound Direction Function Description License service HMI Load 1033 TCP Outbound HMI Load (RT Basic) HMI Load 2308 TCP Outbound HMI Load (RT Advanced) * Default port that can be changed by user configuration This service provides the complete functionality for software licenses and is used by both the Automation License Manager as well as all license-related software products. This service is used to transmit images and configuration data to Basic Panels. This service is used to transmit images and configuration data to panels. WinCC Simulation for Basic Panels Name Port number Transport protocol Direction Function Description HMI Load 1033 TCP Inbound HMI Load (RT Basic) EtherNet/IP 44818 TCP Outbound Ethernet/IP channel 2222 UDP Inbound Ethernet/IP channel Modbus TCP 502 TCP Outbound Modbus TCP channel This service is used to transmit images and configuration data to Basic Panels. The Ethernet/IP protocol is used for connections to Allen Bradley PLCs. The Ethernet/IP protocol is used for connections to Allen Bradley PLCs. The Modbus TCP protocol is used for connections to Schneider PLCs. RFC 1006 102 TCP Outbound S7 channel Communication with the S7 controller via Ethernet/PROFINET Mitsubishi MC 5002 TCP Outbound Mitsubishi MC channel The Mitsubishi protocol is used for connections to Mitsubishi PLCs. 6 System Manual, 12/2017, Online help printout

Security information WinCC Simulation for Panels and Runtime Advanced Name Port number Transport protocol Direction Function Description DCP --- Ethernet Outbound PROFINET The DCP protocol (Discovery and basic Configuration Protocol) is used by PROFINET and provides the basic functionality for locating and configuring PROFINET devices. LLDP --- Ethernet Inbound, Outbound PROFINET SMTP 25 TCP Outbound SMTP Communication The LLDP protocol (Link Layer Discover Protocol) is used by PROFINET for topology detection. This service is used by WinCC Runtime Advanced to send e-mails. HTTP 80* TCP Inbound Sm@rtServer The Web server is only available when Sm@rtService is activated. The used port may differ depending on automatically selected settings. RFC 1006 102 TCP Outbound S7 channel Communication with the S7 controller via Ethernet/PROFINET NTP 123 UDP Outbound Time synchronization The NTP protocol (Network Time Protocol) is used for time synchronization in IP-based networks. SNMP 161 UDP Outbound PROFINET The SNMP client functionality is used by STEP 7 to read status information from PROFINET devices. HMI Load 2308 TCP Outbound HMI Load (RT Advanced) This service is used to transmit images and configuration data to panels. HTTPS 443* TCP Inbound Sm@rtServer The Web server with HTTPS protocol is only available when Sm@rtService is activated. The used port may differ depending on automatically selected settings. VNC server 5900* TCP Inbound Sm@rtServer This service is only available when Sm@rtService is activated. 5800* TCP Inbound Sm@rtServer This service is only available when Sm@rtService is activated. VNC client 5500 TCP Outbound Sm@rtServer This service is only available when Sm@rtService is activated. * Default port that can be changed by user configuration PROFINET protocols for Panels and Runtime Advanced Name Port number Transport protocol DCP --- Ethernet Outbound Lifelist, LLDP --- Ethernet Inbound, Outbound Direction Function Description PROFINET Discovery and configuration PROFINET Link Layer Discovery protocol The DCP protocol (Discovery and basic Configuration Protocol) is used by PROFINET and provides the basic functionality for locating and configuring PROFINET devices. The LLDP protocol (Link Layer Discover Protocol) is used by PROFINET for topology detection. System Manual, 12/2017, Online help printout 7

Security information PROFINET protocols for Panels and Runtime Advanced MRP --- Ethernet Outbound PROFINET medium redundancy PROFINET IO Data --- Ethernet Inbound, Outbound NARE --- Ethernet Inbound, Outbound PROFINET Context Manager 34964 UDP Inbound, Outbound PROFINET Cyclic IO data transfer Name Address Resolution PROFINET connection less RPC The MRP protocol (Medium redundancy protocol) enables control of redundant transmission paths using a ring topology. Cyclic data exchange is used by panels for direct keys and LEDs. This protocol is used to resolve network names and assign IP addresses. The PROFINET Context Manager provides an endpoint mapper in order to establish an application relation (PROFINET AR). Communication connections for Panels and WinCC Runtime Advanced Name Port number Transport protocol Direction Function Description Telnet 23 TCP Inbound Telnet This service can be used for maintenance. SMTP ** TCP Outbound SendEMail This service is used by Windows CE / PC Runtime to send e-mails. HTTP 80* TCP Inbound Hypertext Transfer Protocol The HTTP protocol is used for communication with the internal Web server. RFC 1006 ** TCP Outbound S7 channel Communication with the S7 controller via Ethernet/PROFINET. HMI Load 102 TCP Inbound Transfer This service is used to transmit images, Runtime, and configuration data to the panel via PN/IE NTP ** UDP Outbound Time synchronization The NTP protocol (Network Time Protocol) is used for time synchronization in IP-based networks. DCOM*** 135 TCP Inbound OPC server This service is a component of the Microsoft Windows operating system. Communication via OPC (DA) is based on DCOM. This service is therefore required to initialize OPC (DA) connections. DCOM*** ** TCP Outbound OPC server The communication via OPC (DA) is based on DCOM and uses unspecified ports assigned by the system. This should be taken into consideration when using OPC (DA) and creating rules for the firewall. NetBIOS over TCP/IP NetBIOS over TCP/IP ** UDP Outbound With the use of Remote File Share ** UDP Outbound With the use of Remote File Share SNMP 161 UDP Inbound Simple Network Management Protocol Register / log on to a remote server. Register / log on to a remote server. The SNMP client functionality is used by STEP 7 to read status information from PROFINET devices. 8 System Manual, 12/2017, Online help printout

Security information Communication connections for Panels and WinCC Runtime Advanced HTTPS 443* TCP Inbound Secure Hypertext Transfer Protocol Modbus TCP ** TCP Outbound Modbus TCP channel Mitsubishi MC ** TCP Outbound Mitsubishi MC channel The HTTP protocol is used for communication with the panel-internal Web server via Secure Socket Layer (SSL). The Modbus TCP protocol is used for connections to Schneider PLCs. The Mitsubishi protocol is used for connections to Mitsubishi PLCs. Printing ** TCP Outbound Printing Printing on the control panel (via Ethernet). HMI Load 2308 TCP Inbound Transfer This service is used to transmit images and configuration data to panels. On Comfort Panels, this service has been replaced by Device Manager and SCS as of V13. This service is used to transmit configuration data to WinCC Runtime Advanced. HMI Load 50523 TCP Inbound Transfer This port is used if port 2308 is not available. ALM 4410* TCP Inbound, Outbound Application License Manager This service is used to transmit images and configuration data to panels. On Comfort Panels, this service has been replaced by Device Manager and SCS as of V13. This service is used to transmit configuration data to WinCC Runtime Advanced. This service of RT Advanced makes available the complete functionalities for software licenses and is used by the Automation License Manager. OPC UA 4870* TCP Inbound OPC UA server This service is required for communication via OPC UA. HMI Load 5001 TCP Inbound Device Manager This service is used to transmit images and Runtime to panels. HMI Load 5002 TCP Inbound SCS (System Configuration Server) This service is used to transmit configuration data to panels. VNC client 5500 TCP Inbound Sm@rtServer Reverse VNC server connection. Receive mode is set for the VNC client. VNC server 5800* TCP Inbound Sm@rtServer VNC server connection HTTP 5900* TCP Inbound Sm@rtServer VNC server connection SIMATIC Logon ** TCP Outbound UMAC (User Management to the Access Control) Allen Bradley Ethernet IP Reserved 49152... 65535 ** TCP Outbound Ethernet/IP channel * Default port that can be changed by user configuration ** Port is assigned automatically. *** Supported by WinCC Runtime Advanced only. Register / log on to a remote server. The Ethernet/IP protocol is used for connections to Allen Bradley PLCs. TCP/UDP Outbound Dynamic port range is used, for example, to connect to the remote file sharing. System Manual, 12/2017, Online help printout 9

Security information 10 System Manual, 12/2017, Online help printout

Installation 2 Contents Information that could not be included in the online help. Virus scanners during installation Virus scanners should be disabled during the installation of WinCC. Operating system message for SIMATIC USB drivers An operating system message relating to the SIMATIC USB driver is issued on the operating system Windows Server 2003 R2 StdE SP2. This message must be acknowledged with "Yes" as soon as possible after the message has been issued. The message may be in the background and therefore not be immediately visible. After a certain period of time, the setup continues with the next component. The SIMATIC USB drivers are then not installed and can not be used. System Manual, 12/2017, Online help printout 11

Installation 12 System Manual, 12/2017, Online help printout

Runtime 3 3.1 Notes on operation in Runtime Contents Information that could not be included in the online help and important information about product features. Focus in runtime If you have configured a low-contrast combination of focus color and border color for an HMI device with version 12.0.0 or earlier, the focus may no longer be identifiable in runtime after you change the device version in the TIA Portal. Change one of the two colors. Language behavior - Layout of on-screen keyboard The layout of the on-screen keyboard does not change when you switch to a runtime language that is not installed for the keyboard layout. In this case, the language setting for the keyboard remains set at the most recent valid language or the language setting for the default keyboard layout of Windows is used. Tag values exceed the maximum length You enter a character string in a string tag via an I/O field. If the character string exceeds the configured number of tags, the character string will be shortened to the configured length. Empty alarm texts Runtime is running with a project. The project is saved on a network drive. In the event of interruptions to the network drive connection, Runtime may attempt to load alarm texts from the network drive. In the event of disconnection, the alarm window or the alarm view remains empty. To avoid this, copy the project to a local drive before the starting the project in Runtime. Duration of log initialization (Panels, RT Advanced) Initialization of the logs on some storage media can take up to 5 minutes. The successful completion of initialization is immediately confirmed by a system event. If there is no storage medium for logging when Runtime starts, the appearance of the system event can also take up to 5 minutes. System Manual, 12/2017, Online help printout 13

Runtime 3.1 Notes on operation in Runtime Large logs delay the ending of Runtime (Basic Panels 2nd Generation) When very large logs are used, ending Runtime can take a long time. Use segmented logs as an alternative to very large circular logs. Slow reaction of SmartServer The following programs may start and respond very slowly with Windows 7: HMI TouchInputPC SmartServer: <Ctrl+Alt+Del> shortcut in the logon dialog The delay is caused by the callback for the Internet certificate validation. Remedy: You can find the following files on the product DVD under: Support\Windows7\CRL_Check or CD_RT\ Support\Windows7\CRL_Check\: DisableCRLCheck_LocalSystem.cmd DisableCRLCheck_CurrentUser.cmd 1. Run the "DisableCRLCheck_LocalSystem.cmd" file with administrator rights. Select the command "Run as administrator" from the shortcut menu of the file. 2. Reboot the PC. If the problem persists, follow these steps: 1. Double-click the file and run the "DisableCRLCheck_CurrentUser.cmd" file with user rights. 2. Reboot the PC. Note The callback for the certificate validation is disabled for all users or PCs. To restore the original state, perform the following files: RestoreDefaults_LocalSystem.cmd RestoreDefaults_CurrentUser.cmd You can find the files in the following directory of the product DVD: Support\Windows7\CRL_Check or CD_RT\Support\Windows7\CRL_Check\ Ending screensaver on the Sm@rtServer When the screensaver is active on the Sm@rtServer on the server HMI device, you require write access to the Sm@rtClient side in order to end the screensaver on the server HMI device. Avoiding corrupt files during power failure If a power failure occurs in Windows systems while the WinCC system is active, files may be corrupt or destroyed. Operation with the NTFS file system provides better security. Secure, continuous operation is only ensured by using an uninterruptible power supply (UPS). 14 System Manual, 12/2017, Online help printout

Runtime 3.3 Communication 3.2 Notes on operation of Runtime Advanced Contents Information that could not be included in the online help and important information about product features. Starting Runtime Only WinCC Runtime V15 can be started in TIA Portal V15. WinCC Runtime V11.02, V12, V13, V13 SP1, V14 and V14 SP1 can be simulated in TIA Portal V14 SP1. Screen saver on computers with Windows 10 On a computer with Windows 10, an activated screen saver is no longer terminated when an alarm of the "error" class is output. Authorization for starting Runtime (RT Advanced) On a computer running the 32-bit version of Windows 7, WinCC Runtime Advanced can only be started if a user is a member of the automatically created group "Siemens TIA Engineer"..Net-Controls in Runtime If you have incorporated a.net control in your project as "Custom.Net control", you have to copy the files belonging to these controls to the installation directory of WinCC Runtime, e.g. "C:\ProgramFiles\Siemens\Automation\WinCC RT Advanced". Otherwise, the control cannot be loaded in Runtime. Disabling automatic checking for software updates If the Engineering System is installed together with Runtime on a PC, the operator gets notifications above software updates. For the system to run reliably on a multi-user system, the same software version must be installed on all PCs. It is possible to disable the automatic checking for software updates and to thus improve performance. To disable the automatic checking for software updates, go to "Settings > General > Software updates" and clear the "Check daily for updates" check box. 3.3 Communication Contents Information that could not be included in the online help. System Manual, 12/2017, Online help printout 15

Runtime 3.3 Communication Using "DTL" data type for area pointers Use the "DTL" data type for configuration of area pointers "Date/time" and "Date/time PLC". The "DTL" data type supports time stamp information in the nanosecond range. Because Basic Panels support time stamp information only down to the millisecond range, you will encounter the following restrictions when using the area pointers: Area pointer "Date/time" For transmission of time information from a Basic Panel to the PLC, the smallest unit of time is 1 millisecond. The value range from microseconds to nanoseconds of the "DTL" data type will be filled with zeros. Area pointer "Date/time PLC" For transmission of time information from a PLC to a Basic Panel, the area from microseconds to nanoseconds will be ignored. The time information will be processed on the panel down to milliseconds. RT Advanced communication via Station Manager (SIMATIC NET) with a SIMATIC S7 1200 The following restrictions apply to the PC that communicates with SIMATIC S7 1200 via router using WinCC RT Advanced or RT Professional: Windows 7: Only with installed SIMATIC NET 8.1 Windows XP: Communication via Station Manager (SIMATIC NET) is not supported These restrictions also apply if you are using WinAC MP or Station Manager. Connections with the help of the Station Manager of Runtime Advanced are always treated as routed connections. 16 System Manual, 12/2017, Online help printout

Index A Area pointer Date/time, 16 Date/time PLC, 16 D DTL data type Restriction, 16 System Manual, 12/2017, Online help printout 17

Index 18 System Manual, 12/2017, Online help printout