Leksell SurgiPlan. Powerful planning for success

Similar documents
Leksell SurgiPlan Overview. Powerful planning for surgical success

Comprehensive treatment planning for brachytherapy. Advanced planning made easy

Accuracy study. Elekta Synergy S. High precision radiation therapy using Elekta Synergy S. UMC, Utrecht, Netherlands. Institution: Purpose:

OBJECT MANAGEMENT OBJECT MANIPULATION

LEAD LOCALIZATION. Version 1.0. Software User Guide Revision 1.1. Copyright 2018, Brainlab AG Germany. All rights reserved.

Automatic Subthalamic Nucleus Targeting for Deep Brain Stimulation. A Validation Study

Oncentra Brachy. Anatomy-based treatment planning for HDR/PDR brachytherapy

Image Registration I

Computational Medical Imaging Analysis Chapter 4: Image Visualization

5. USER INTERFACE. We use a commercially available six-degree-of-freedom tracking system called the FASTRAK, manufactured by

If it matters to you, it matters to us

iplan RT Image Advanced Contouring Workstation - Driving Physician Collaboration

Neuroscience. Products and Services Catalog. Gamma Knife Radiosurgery Magnetoencephalography Stereotactic Neurosurgery Elekta Services

Position accuracy analysis of the stereotactic reference defined by the CBCT on Leksell Gamma Knife Icon

A Study of Medical Image Analysis System

Ultrasound To Go. The MySono U5 -

Redefining ultrasound access. Introducing the Viera portable breast ultrasound

Design and performance characteristics of a Cone Beam CT system for Leksell Gamma Knife Icon

Leica EM KMR3. Balanced-break Glass Knife Maker

Experience workflow in full bloom PCR Eleva Philips Computed Radiography

BUZZ - DIGITAL OR WHITEPAPER

Computer Aided Surgery 8:49 69 (2003)

Ultrasound To Go. MySono U5

Imaging protocols for navigated procedures

ADVANCING CANCER TREATMENT

Measure at the speed of light...

Methodological progress in image registration for ventilation estimation, segmentation propagation and multi-modal fusion

ADVANCING CANCER TREATMENT

A Workflow Optimized Software Platform for Multimodal Neurosurgical Planning and Monitoring

Interoperability Issues in Image Registration and ROI Generation

By your side. Anytime. Anywhere.

As fl exible as your care requires

Fiber Selection from Diffusion Tensor Data based on Boolean Operators

IMSURE QA SOFTWARE FAST, PRECISE QA SOFTWARE

Advanced Visual Medicine: Techniques for Visual Exploration & Analysis

Intelligent 3DHD Visualization for Microsurgery

Research on Laser Positioning Technology of CMOS Triangulation for Precision Surgery

The Trimble 3D Scanning Solution: Designed by Surveyors for Surveyors

HyLED 8 Series. LED Surgical Lights. Technical Specifications. HyLED 8600/8600M 160,000 lux. Central illuminance (at 1m distance) mm

The Advanced Neuro MR Processing & Visualization Solution

Medical Image Registration by Maximization of Mutual Information

Medical Image Analysis

2 Michael E. Leventon and Sarah F. F. Gibson a b c d Fig. 1. (a, b) Two MR scans of a person's knee. Both images have high resolution in-plane, but ha

Leica FL800. Integrated Vascular Fluorescence. Living up to Life

DICOM VIEWER. Version 3.2. Software User Guide Revision 1.1. Copyright 2017, Brainlab AG Germany. All rights reserved.

Maximum usability. Electronic capture request. Digitally signed approval. X-ray exposure. Image evaluation. 2D imaging. Digitally signed approval

fmri/dti analysis using Dynasuite

Data Fusion Virtual Surgery Medical Virtual Reality Team. Endo-Robot. Database Functional. Database

THE WIRELESS PHANTOM PERFORM ACCURATE PATIENT QA IN LESS TIME THAN EVER!

Acknowledgements. Atlas-based automatic measurements of the morphology of the tibiofemoral joint

Improve your image. ClearVue 550 ultrasound system. The print quality of this copy is not an accurate representation of the original.

CATIA ICEM AEROEXPERT PERFECTION IN AERONAUTICAL SURFACE DESIGN

Transforming Datasets to Talairach-Tournoux Coordinates

VIEWER. Version 4.0. Software User Guide Revision 1.0. Copyright 2018, Brainlab AG Germany. All rights reserved.

Using Pinnacle 16 Deformable Image registration in a re-treat scenario

Lucy Phantom MR Grid Evaluation

multimodality image processing workstation Visualizing your SPECT-CT-PET-MRI images

Medical Image Processing: Image Reconstruction and 3D Renderings

MCL-Collection Fast and Easy Applications Development

Medical Image Registration

See it from every angle.

SMARTBRUSH. Version 2.5. Software User Guide Revision 1.0. Copyright 2016, Brainlab AG Germany. All rights reserved.

Fmri Spatial Processing

technical notes trimble realworks software

Trimble Realworks Software

Discovery LS 1.0 Conformance Statement For DICOM V3.0

Leica EM CPD300. Automated Critical Point Dryer Controlled Specimen Drying for Biological and Industrial Applications

Leica BOND III. Fully automated IHC & ISH. Quality. Speed. Efficiency.

ThE ultimate, INTuITIVE Mr INTErFAcE

Product Data Sheet DeltaV Operate for PROVOX July 2014 Page 1

nvent RAYCHEM NGC-40 SYSTEM OVERVIEW

INSPIRED BY YOUR PATIENTS.

Leica LAS Live Image Builder

Overview of Proposed TG-132 Recommendations

Getting Good Data with xponent Software for the Luminex MAGPIX, Luminex 100/200, and FLEXMAP 3D Systems

RealWorks Software. A Powerful 3D Laser Scanning Office Software Suite

icatvision Quick Reference

IBDN 110 Cross-Connect System

Technical aspects of SPECT and SPECT-CT. John Buscombe

DeltaV History Analysis

Biomedical Image Processing

Leica DMD108. Modern Network Imaging Solution for Laboratories

Development and Human Factors Analysis of Neuronavigation vs. Augmented Reality

ECE1778 Final Report MRI Visualizer

Advanced Targeting Using Image Deformation. Justin Keister, MS DABR Aurora Health Care Kenosha, WI

Proprietary High Performance KVM system for point to point and matrix applications

Bio-Rad Laboratories AUTOIMMUNE TESTING. System. PhD. IFA and EIA Instrumentation. One revolutionary platform, two technologies

Trimble Railways GEDO Trolley System

CRANIAL TRAJECTORY PLANNING

J6848A Report Center Advanced network analysis and reporting for the Network Analyzer Wireline protocol test product

Learn Image Segmentation Basics with Hands-on Introduction to ITK-SNAP. RSNA 2016 Courses RCB22 and RCB54

WayPoint Navigator (software version 4.5)

WayPoint Navigator (software version 4.5)

Realworks Software. A Powerful 3D Laser Scanning Office Software Suite

new product» new product atlas HD automated synthesis system Next generation jacketed reactor platform

Ultrasound Probe Tracking for Real-Time Ultrasound/MRI Overlay and Visualization of Brain Shift

DICOM Conformance Statement. Leksell GammaPlan & Leksell SurgiPlan 10.2

ScholarOne Abstracts. Review Administrator Guide

Storage Tank Solutions TRANSFORMING THE WAY THE WORLD WORKS

Endoscopic Reconstruction with Robust Feature Matching

Transcription:

Leksell SurgiPlan Powerful planning for success

Making a difference in surgical planning Leksell SurgiPlan Leksell SurgiPlan is an advanced image-based neurosurgical planning software, specifically designed for use with Leksell Stereotactic System. With its powerful Linux-based operating system and flexible pre-planning capabilities, it offers neurosurgeons a greater degree of freedom and precision in planning and evaluating different surgical approaches. This easy-to-learn package plays an important role in optimizing workflows, potentially improving clinical outcomes and enhancing the cost-efficiencies of treatment. A modular system to meet your needs Leksell SurgiPlan offers a range of powerful tools for increasing the precision and confidence of the planning procedure. Based around a high-performance and reliable Linux-based operating system, this modular platform combines advanced image handling options with a new graphic interface for excellent ease-of-use. It also ensures that future requirements can be met in a focused, costeffective manner. Streamlining procedure planning The system is organized in modules from which you can design your own planning and evaluation tool. Each module is designed to meet specific needs. Stereotactic Planning is the basic module that offers a wide variety of features to plan the surgical approach. Together with Image Fusion it enhances target definition. Another combination, Functional Planning and AtlasSpace, focuses on functional neurosurgery and is ideal for accurate localization of functional targets. ImageMerge software streamlines the procedure of image interpretation and pre-operative planning through co-registration of frame-based and frameless image studies from CT and MR scanners. Image interpretation is further expanded with the physiological data provided by ColorPET. The Pre-Planning module enables treatment planning on frameless images, separating the pre-operative planning from the day of surgery. Seamless integration Each module is integrated seamlessly for accurate planning and a smooth workflow. The power to make a difference The high-performance, PC-based Leksell SurgiPlan offers a clear step up in capabilities over previous versions. The greater computing power translates directly into a higher ability to handle large numbers of different image studies and better support for frameless images. The ability to do more, faster, makes for even greater cost-efficiencies in treatment. Mobility for greater efficiency To promote flexibility further Leksell SurgiPlan is also available on a dedicated, high-end PC laptop for the neurosurgeon to use anytime and anywhere. An excellent educational tool Leksell SurgiPlan provides an excellent tool for educational purposes with its user-friendly graphical user interface and intuitive workflow. 2

Combine modules to meet your needs Pre-Planning Functional Planning Image Fusion AtlasSpace ColorPET Stereotactic Planning ImageMerge 3

Optimizing surgical approaches Stereotactic Planning Surgical paths can be planned and manipulated across different image views and studies with immediate visual feedback. The paths can also be seen along the probe s eye view or parallel with the probe. All defined objects and paths can be displayed in different 3-D renderings, facilitating more complete planning validation. Once images are imported, they are automatically scaled by an optimization algorithm based on their dynamic range so that they will be displayed with the best possible contrast and brightness. Stereotactic Planning supports MR, CT and angio images. When measuring lengths, millimeter scales are directly displayed in the images. 3-D rendering. Path planning. Enhancing target definition Image Fusion Image Fusion enhances the definition of the target by enabling two frame-based image studies of different modalities to be blended. The fused images have the same high accuracy as the original images, since both image studies are defined in Leksell stereotactic space by Leksell Coordinate Frame. Interactive image fusion of CT and MR images. 4

Designed for functional neurosurgery Functional Planning Leksell SurgiPlan offers dedicated capabilities for functional procedures, facilitating improved clinical outcomes. The AC-PC line can easily be defined whether or not it lies within a single image plane. The patient s images can then be realigned with the AC-PC line so they are truly axial, coronal and sagittal, making them easier to reference with different brain atlases. This feature also facilitates the process of frame attachment, since perfect frame alignment with the AC-PC line is no longer necessary. Functional targets can be localized using formulas based on distances from the AC-PC line, which automatically then provide the corresponding stereotactic coordinates. Simple and intuitive user interface allows direct manipulation in images and simultaneous display of different modalities and orientations. AC PC Target Close-up of axial view showing AC-PC line and path. 5

Navigate with confidence AtlasSpace AtlasSpace is intended for use when performing functional procedures. Based on the three original series of the Schaltenbrand & Wahren* atlas it offers a combination of sophisticated 3-D matching, overlay of atlas contours on patient images, and interactive selection of displayed atlas contours. It increases confidence and ease of use by facilitating interpretation of patient images and identification of correct targets. Fast and flexible matching in 3 dimensions AtlasSpace overlays the atlas contours from the Schaltenbrand & Wahren atlas directly on the patient s images. It matches the data in three dimensions by using the Talairach proportional grid, which uses eight anatomical landmarks. The atlas contours can also be well matched in all dimensions to non-symmetrical brains. Once a target area is selected the matching can be further refined using local anatomical landmarks. Workspace showing paths, entry points and targets in treatment plan. Accurate identification with interactive and customized atlas contours The atlas contours can be turned on or off individually. Groups of user selected contours can be defined so that only the relevant structures for different procedures are displayed, according to the individual surgeon s preferences. Close-up of axial view showing atlas contours. These customized sets of structures can also be easily saved for future use by using the mini menu inserted on screen The atlas contours are interactively labeled, and by placing the cursor on a displayed contour, the name of the contour is revealed. Neighboring contours always have different colors. * George Thieme Verlag, Stuttgart/New York 6

Completing the picture ImageMerge ImageMerge facilitates better interpretation by enabling the co-registration of additional frameless image studies. One image study scanned with Leksell Coordinate Frame can thus be matched with any other image study when the use of previously scanned images is desired. ImageMerge supports both MR and CT images, and PET images (with the optional ColorPET module). Co-registration of frameless and frame-based image studies. Better interpretation with additional image modalities Merging CT and MR image studies provides high quality images of bone structures and excellent definition of tissue. When using PET images physiological data may be added to further increase the information of the presented images. Automatic co-registration The fully automatic option is both fast and highly accurate, with no need to define any anatomical landmarks. As part of the automatic co-registration a movable lens is displayed in both images in order to facilitate checking the accuracy of the result. When the co-registration is completed the image studies are displayed in axial, sagittal and coronal directions to further help verify the result. Where the images do not have enough mutual information, manual co-registration is also available. Promoting flexibility ImageMerge facilitates scheduling with regard to MR scanning since it allows images to be scan ned in advance of the day of surgery. This feature also enhances convenience and comfort for the patient. Improved follow-up For comprehensive evaluation ImageMerge enables not only pre-operative images but also post-operative images to be easily aligned with the image studies used for the surgery. Adding information ColorPET The ColorPET module for ImageMerge allows importation as well as visualization of color coded PET image studies. The user can combine the physiological data of PET images with the anatomical data provided by CT and MR images. Color coded PET image. 7

Increased flexibility in planning Pre-Planning The Pre-Planning module increases flexibility and saves time as well as resources considerably by allowing the neurosurgeon to plan procedures days ahead of the surgery, and to base decisions on frameless images. All that is required on the day of the surgery is a CT registration scan with the frame. It is then possible to import the draft plan and co-register it using ImageMerge. All the treatment data (such as AC-PC line, targets, paths and measurements) created in the draft plan are included and transformed into Leksell coordinates. By supporting the use of frameless images and allowing planning to be based on these, the Pre-Planning module increases the freedom-of-choice for the neurosurgeon and facilitates more efficient scheduling. This module requires ImageMerge. Target planning on frameless images. More effective follow-up and additional treatment The Pre-Planning module enables the use of frameless images when evaluating the results of treatment on follow-up images, which can be merged with the original treatment plan. Should additional surgical procedures be necessary, a previous treatment plan can be imported and can serve as input when planning the next treatment. Optimizing the use of existing image studies and plans in this way also enhances cost-efficiency. Path definition on frameless images. Improved patient comfort For the patient, the combination of being able to plan before the day of surgery and the ability to use previously taken images, means greater patient comfort. 8

Summary Stereotactic planning Graphical user interface is designed for ease-of-use, optimized for image display on screen and provides updates in real time. Software is compatible with CT, MR and angiographic images. Advanced 3-D rendering helps visualize patient data and planning. Targets can be easily defined with the semi-automatic outline function, which also allows for complex non-continuous regions. Alternative approaches and multiple paths can be easily simulated and evaluated, and can be simultaneously displayed on all open image studies and reconstructions. Paths can also be seen either along the probe s eye view or parallel to the probe. The stereotactic coordinates for any selected point or path are determined and displayed. Lengths can be measured using mm scales displayed directly in the images. Planned parameters are summarized in a treatment protocol together with patient data and a wire frame skull display. Image fusion For blending two stereotactic image studies of different modalities. Handles CT, MR and PET images. The same accuracy as the original image studies. Functional planning The AC-PC line can be defined in 3-D space, whether or not it is localized within a single image. All images can be aligned to AC-PC line. Localization of functional targets by using AC-PC line-based formulas. Automatically provided stereotactic coordinates for functional targets. AtlasSpace Axial, coronal and sagittal views based on the three original micro series of the Schaltenbrand & Wahren atlas for Stereotaxy of the Human Brain. Extended to cover both hemispheres and mutually co-registered. Matching atlas and patient data by using the 3-D Talairach proportional grid with anatomical landmarks. Matching can be refined by using local landmarks. Atlas contours overlayed on patient s images. Interactive labeling of atlas contours. Name of structure automatically shown. The user can select relevant atlas contours. ImageMerge Facilitates pre-operative planning and post-operative follow-up by co-registering image studies from CT, MR and PET scanners. Only one registration image study with Leksell Coordinate Frame is needed. Provides both automatic and manual alignment of images. Automatic co-registration based on mutual information. Visual verification of a co-registration result with movable lens tool. ColorPET Optional module for co-registration of PET image studies. Visualization of color coded PET images, with user-defined as well as sample color maps. Pre-Planning Allows complete pre-operative planning based on frameless images. A co-registration with a frame-based image study is then done using ImageMerge on the day of surgery. Follow-up allows evaluation of results of treatment at different points in time using frameless images. All data from the treatment examination is imported. Additional treatment previous treatment plan can be imported and used as input to the planning of the additional treatment. 9

www.elekta.com Corporate Head Office: Elekta AB (publ) Box 7593, SE-103 93 Stockholm, Sweden Tel +46 8 587 254 00 Fax +46 8 587 255 00 info@elekta.com adapted to the task Regional Sales, Marketing and Service: North America Atlanta, USA Tel +1 770 300 9725 Fax +1 770 448 6338 info.america@elekta.com Europe, Latin America, Africa, Middle East & India Tel +44 1293 544 422 Fax +44 1293 654 321 info.europe@elekta.com Asia Pacific Hong Kong, China Tel +852 2891 2208 Fax +852 2575 7133 info.asia@elekta.com Human Care Makes the Future Possible Art. No. 018678.03 FEB10. 2010 Elekta Instrument AB. All mentioned trademarks and registered trademarks are the property of the Elekta Group. All rights reserved. No part of this document may be reproduced in any form without written permission from the copyright holder. Specifications subject to change without notice.