Global Water Instrumentation, Inc.

Similar documents
Global Water Instrumentation, Inc.

Global Water globalw.com. Global Water. Instrumentation, Inc.

Global Water globalw.com. Global Water. Instrumentation, Inc.

Global Water Instrumentation, Inc.

Quick Reference Flow Probe FP101 & 201

PLM. Global Logger for Palm OS. 3/15/2002 Copyright Global Water Instrumentation, Inc Global Water (800)

HydroLynx Systems, Inc. Model 50386D Decoder Instruction Manual

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL

4300 WINDFERN RD #100 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

MODBUS MANUAL For the AccUView UV Transmission Monitor

V-9941A ONE ZONE HANDSFREE TALKBACK CONTROL UNIT

VIP-480AL IP One-Way Horn

poly-planar Marine Audio System

WL16 Data Logger Covers WL16S and WL16U Data Loggers

I/O Expansion Box Installation & Operator s Instruction Manual

VIP-812A DUAL NETWORKED STATION PORT

VCMDM MODEM INSTALLATION INSTRUCTIONS

4300 WINDFERN RD #100 - HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

V CHANNEL MODULAR PRE-AMP/MIXER V-9984 REMOTE INPUT MODULE V CHANNEL MODULAR PRE-AMP/MIXER

V-9939B MICROPHONE ADAPTER

VE8014A/VE8014AR QUAD NETWORKED STATION PORT

PD10. Pulse Divider Instructions PROUDLY MADE IN THE USA

OZONE SWITCH Model OS-6. OS-6 Features

VIP-804 QUAD ENHANCED NETWORK AUDIO PORT

User's Guide. Extech AM A AC Analog Clamp Meter

PagePac PAGEPAC PLUS ZONE EXPANSION UNIT V

Owner s Manual. TSD-DCPDV DC Power Distribution with Fixed & Variable Outputs. TSD-DCPDV DC Power Distribution. AtlasSound.com

OPERATING MANUAL LOW-VOLTAGE DISCONNECT PANELS LVD400 & LVD600 SERIES

INSTRUCTION MANUAL. Model True RMS AC/DC 30A Mini Clamp-on Meter. Introduction. True RMS AC Current and Voltage

Model 206 Operating Instructions. Setra Systems, Inc. 159 Swanson Road, Boxborough, MA

V-9964 Digital Feedback Eliminator/Message Stacker

MYRIAD LC1 LEVEL CONTROLLER INSTRUCTION MANUAL

FA-2448 SIX POSITION Filter Wheel

Model EZ3400 EasyTouch Owner s Manual

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

User's Guide. Phase Sequence and Motor Rotation Tester Model

User's Guide. MiniTec TM Series Model MN25 MultiMeter

RTD SAMPLER OPERATOR S MANUAL

FP111-FP211-FP311 Global Water Flow Probe User s Manual

Pit Transition with 24" Fan Installation and Operators Instruction Manual

Installation Manual. Flow Max 110

I/O SIGNAL CONDITIONER

TSD-SEQ6 Sequencer Controller

QuickTouch (QT4) Owner s Manual

User s Guide. 600A AC Clamp Meter. Model 38387

TM0-1 AMPLIFIER / CONDITIONER MODULE OPERATORS MANUAL. Transducer Techniques R

Owner s Manual. TSD-DCPDV DC Power Distribution with Fixed & Variable Outputs. TSD-DCPDV DC Power Distribution. AtlasIED.com

VSD-1MC MANUAL 0-10V / 4-20mA Variable Speed Module with Manual Override

RAA100 Rudder Angle Adapter. User s Manual

NOTE: The F2 button and the 4 LED annunciators do not function on the LD-ACF-I. To use these features, ask about the LD-ACF-R4/R4A.

MODBUS MANUAL For the CLX Online Chlorine Analyzer

Operation Manual CX10 1/8 DIN Microcomputer Based Conductivity/Resistivity Controller

OPERATOR S MANUAL FPD 50 WATT POWER SUPPLY. Flat Pack Single Output DC to DC Converter 50 Watt Output 24 Vdc Nominal Input

INSTRUCTION MANUAL. SGB20(D) Transient Protection System. June Copyright 2008 Campbell Scientific (Canada)Corp.

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features

SVP110 SURGE VOLTAGE PROTECTOR INSTRUCTION MANUAL

ES-600 Ozone Controller Operation Manual

4" AMPLIFIED RECESSED CEILING SPEAKERS 8" AMPLIFIED RECESSED CEILING SPEAKERS

Instruction Sheet ICLS-COOL TM. Quiet-Cool Series Closet Cooler ICLS-COOL1 ICLS-COOL2

INSTRUCTION MANUAL. AquiStar GDL. Dissolved Oxygen Datalogger

Digital Vane Thermo-Anemometer Model

Operations Manual EcoSense ph100

Operation Manual CX20 1/8 DIN Microcomputer Based Conductivity/Resistivity Controller

Heavy Duty Vibration Meter

V-9908 MESSAGE/PAGE PANEL

Power Rack 58. EXT-PS5-8R User Manual.

User's Guide. Datalogging Light Meter with PC Interface. Model

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features

V-9964 Digital Feedback Eliminator/Message Stacker

User Guide. Control Box. RoscoLED TM.

STATIC METERS Models 211 & 212. SURVEYORSTAT Models 211XL & 212XL

PMDX-105 Quad Isolator Board

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

SA SERIES Arlingate Lane, Columbus, Ohio (614)

OPERATIONS MANUAL PCM-DOC

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

RemLynx Remote Windows Computer Software 5073RemLynx DCN-M408

User Guide. Moisture Meter. Model MO250

VELOCICALC Air Velocity Meter

62533 Ethernet Adapter

Power Supply (48Vdc, 2.5A)

Proliphix EPA-60 Installation Guide

DIN-191 and DIN-192 SERIES CONVERTER BOXES USERS MANUAL

VADDIO /CANON BU-SERIES PTZ CAMERAS

PixController, Inc. Wireless Switch Sensor For Normally Open (NO) and Normally Closed (NC) Sensors

GARNET. SEELEVEL I TM Tank Indicator INSTRUMENTS LTD. Model 707 Owner's Manual IMPORTANT OPERATOR INFORMATION DATE INSTALLED: Max Signal

Broadband Automatic Disconnect Switch. User Manual

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter

poly-planar Marine Audio Systems

Remote Refrigeration Control

FNet Repeater Installation & Operator s Instruction Manual

Remote Microprocessor Control Panel. for use with the. Redi-Purge. High Efficiency Purge System

Seven Channel Remote Control

AirPro Surveyor 2 Manual

Page TECMount User s Manual. Table of Contents

HD-SDI Vandal Dome Camera

Model CR103J. DC Current and Voltage Calibrator/Standard ±0.01µA to ± mA ±0.1µV to ± V. Operating Manual

MAXIMA + Series ROTARY LEVEL CONTROL

CTI 2552-A 8-CHANNEL ISOLATED RTD INPUT MODULE INSTALLATION AND OPERATION GUIDE. Ver. 1.2 CTI Part #

GL400. Datalogger User s Guide. 1/05/2005 Copyright Global Water Instrumentation, Inc Global Water (800)

Transcription:

Instrumentation, Inc. 11390 Amalgam Way Gold River, CA 95670 T: 800-876-1172 Int l: (916) 638-3429, F: (916) 638-3270 Display: EZ100 11/12/04-1 -

Congratulations on your purchase of the EZ100 Display. This instrument has been quality tested and approved for providing accurate and reliable measurements. We are confident that you will find the EZ100 to be a valuable asset for your application. Should you require assistance, our technical staff will be happy to help. Table of Contents I. Checklist Page 3 II. Inspection 3 III. Display Installation 4 IV. Display Set Up and Use 4 V. Maintenance 5 VI. Troubleshooting 6 VII. Warranty 7 VIII. Appendix A: Display Calibration 8 IX. Appendix B: External Power and Recording Devices 10 * Copyright Instrumentation, Inc. 2004-2 -

I. EZ100 Checklist a. Display b. EZ100 Manual c. Two 9V batteries (Inside case) II. Inspection a. The EZ100 unit was carefully inspected and certified by s Quality Assurance Team before shipping. If any damage has occurred during shipping, please notify Instrumentation, Inc. and file a claim with the carrier involved. Use the checklist to ensure that everything needed to operate the EZ100 was received. - 3 -

III. Display Installation a. The Display is designed for handheld applications, however there are four holes in the back of the case that may be used to mount the unit to a flat surface (screws not included.) b. If the Display is mounted insure that it is located in an area that is protected from direct rainfall and immersion in water. The Display is water resistant, not water proof. c. See Appendix B for installation of Display with external power source and/or additional external recording/monitoring device. IV. Display Set Up and Use Output Range: +1900 Engineering Units Input Range: 4-20 ma Accuracy: +0.1% of full scale Operating Voltage: 12-36VDC Current Draw: Same as sensor output Warm Up Time: 3 seconds Operating Temperature: 0 to +60 C Size of Probe: 4 ¾ x3 1/8 x2 1/8 Weight: 0.5 lb. a. If the EZ100 was shipped with a sensor attached, the display was calibrated for that sensor at s factory. Pressing the button on the front of the EZ100 will display the sensor s output. Please read the sensor manual for installation and maintenance instructions. - 4 -

Two wire sensor attachment b. Unscrew the four bolts in the cover to access the internal terminal strip. Disconnect one of the batteries. Orient the unit with the terminal block at the top, see appendix C. Attach the positive voltage wire to terminal #1. Attach the signal wire to terminal #2. Reconnect the battery. See appendix A for Display calibration instructions. Three wire sensor attachment c. Unscrew the four bolts in the cover to access the internal terminal strip. Disconnect one of the batteries. Orient the unit with the terminal block at the top, see appendix C. Attach the positive voltage wire to terminal #1. Attach the signal wire to terminal #2. Attach the ground wire to terminal #4. Reconnect the battery. See appendix A for Display calibration instructions. V. Maintenance Figure 1. a. Replace the unit s batteries annually. The Display comes with two 9V Lithium batteries. To access the batteries, unscrew the four cover screws and remove the top. - 5 -

VI. Trouble Shooting Issue: Display not reading correctly a. Verify battery voltage (see maintenance section). b. Recalibrate sensor to Display using appendix A. Other issues c. Call us for tech support: 800-876-1172 or 916-638-3429 (many problems can be solved over the phone). Fax: 916-638-3270 or Email: globalw@globalw.com. Be prepared to describe the problem being experienced including specific details of the application and installation and any additional pertinent information. d. In the event that the equipment needs to be returned to the factory for any reason, please call to obtain a RMA # (Return Material Authorization). Do not return items without a RMA # displayed on the outside of the package. Include a written statement describing the problems. Send the package with shipping prepaid to our factory address. Insure the shipment, as the warranty does not cover damage incurred during transit. e. When calling for tech support, please have the following information ready; 1. Model #. 2. Unit serial number. 3. P.O.# the equipment was purchased on. 4. s sales number or the invoice number. 5. Repair instructions and/or specific problems relating to the product. - 6 -

VII. Warranty a. Instrumentation, Inc. warrants that its products are free from defects in material and workmanship under normal use and service for a period of one year from date of shipment from factory. s obligations under this warranty are limited to, at Global Water s option: (I) replacing or (II) repairing; any products determined to be defective. In no case shall s liability exceed the products original purchase price. This warranty does not apply to any equipment that has been repaired or altered, except by Instrumentation, Inc., or which has been subject to misuse, negligence or accident. It is expressly agreed that this warranty will be in lieu of all warranties of fitness and in lieu of the warranty of merchantability. b. The warranty begins on the date of the product s invoice. - 7 -

VIII. Appendix A: Display Calibration a. Remove the front cover of the EZ100 to show the rear of the display. b. The Display must be connected to a 4-20mA sensor or current loop meter to work properly. c. Use the following diagram and tables to determine the correct DIP switch settings for the attached sensor. Minimum Reading (4mA) Figure 2. Maximum Reading (19/20mA) SW1 SW2 SW3 SW4 SW5 0 1200 1200-1999 Off Off Off Off Off 0-600 600-1200 On Off Off Off Off 0-400 400-600 Off Off On Off Off 0-200 200-400 On On On Off Off 0-100 100-200 On On On On Off d. Determine the highest and lowest reading for the display. This is the value that will be displayed at the maximum and minimum output currents of the sensor, Water Level = 0-15 feet, Humidity = 0-100%, etc. Ignore the decimal point and set DIP Switches 1-5 based on the above table: - 8 -

e. Set DIP Switches 6-8 to place the decimal point in the correct position according to the following table: Decimal Location SW6 SW7 SW8 9999 Off Off Off 9.999 On Off Off 99.99 Off On Off 999.9 Off Off On f. Set up the sensor for its minimum output current or put the current loop meter in Simulate mode and set it for the minimum output current of the sensor that will be connected to the EZ100 (4.000mA, 3.986mA, etc). If using a current loop meter, connect the red lead to terminal S1 and the black lead to terminal S2 according to Figure 1 on page 5. g. While holding down the Display button on the front panel of the meter, adjust R3 until the display reads the correct minimum reading. h. Set up the sensor for its maximum output current or set the current loop meter for the output current of the sensor that will be connected to the EZ100 (19.000mA, 19.064mA, 20.000mA, etc). i. While holding down the Display button, adjust R7 until the display reads the correct maximum reading. j. Repeat steps f - i and confirm the display reads the correct low and high values. Readjust R3 and R7 as necessary until the correct display is achieved without adjustment. - 9 -

IX. Appendix B: External Power and Recording Devices a. Use the following instructions to connect an external source that will allow the display and sensor to be powered continuously: 1. Remove both 9 VDC batteries. 2. Remove the battery leads from terminals T1 and T2 (see Figure 1 on page 5). 3. Drill a hole in the bottom of the case next to the sensor wire for a power wire to pass through. Run all external wires through this hole. 4. Seal any gaps with silicon adhesive. 5. Connect a 12VDC to 36VDC external power source to the power terminals, positive to T1 and negative to T2 in place of the battery leads. The display and sensor are now powered continuously. b. Follow the diagram below to connect external power and a PLC or recording/monitoring device. - 10 -