Switch on / off. For switching off please press button for approx. 5 sec.

Similar documents
Operating Instructions for Level Switch for Liquids. Model: RFS

User manual deltawavec-p

Operating Instructions for Low Volume Rotating Vane Flow Meter. Model: DPL-1P... DPL-1V... DPL-1E...

Data sheet deltwavec-f

Operating Instructions for Low Volume Rotating Vane Flow Meter. Model: DPL-1P... DPL-1V... DPL-1E...

Operating Instructions for Digital Thermometers. Model: DTM

OPERATING INSTRUCTIONS

Operating Instruction for Turbine-wheel Flow Meter. Model: DRS

Operating Instructions for Rotating Vane Flow Meter. Model: DRH-...

ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES

Operating Instructions for Differential Pressure Sensor. Model: PMP

KOBOLD TDA Series Digital Temperature Transmitter

ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100 SERIES

Operating Instructions for Turbine Wheel Flow Meter. Model: TUR

LiquiDens. SensoTech. Process density meter for liquids Product description

Operating Instructions for Turbine Wheel Flow Meter Model: TUR

ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES

Operating Instructions for Low Volume Rotating Vane Flow Meter. Model: DTK

Operating Instruction for rotating vane flow meter Model: DPM-...

Operating Instruction for Rotating Vane Flow Meter. Model: DRG-...

Ultrasonic Flow Meter Brochure

ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES

DTE. Digital Thermometer. battery powered. measuring. monitoring. analysing. O O Universal Pt100 or thermocouple sensors Battery powered

Sono-Trak Transit Time Clamp-on Ultrasonic Flow Meter

E4PA. Ultrasonic Displacement Sensor. Ordering Information

The SF-586b Insertion Flow Meter For Compressed Air, Gases And Exhaust Air (up to 400 C) In Pipe Diameters From 25mm to 5000mm

14 Pressure Measurement. Measuring Devices Description Pressure range Connection Device Page

Operating Instruction for Turbine-wheel Flow Meter. Model: DRB-...

DMTFP Portable Ultrasonic Flow Meters

OPTISONIC 6400 Technical Datasheet

Flexible temperature transmitter and sensor

Operating Instruction Supplement for Compact Electronics. Model:..C30R;..C30M..C34P;..C34N

Humidity transmitter for critical climate applications

Precision Hand-held Thermometer

User Manual. Item no.: Otto Graf GmbH Carl-Zeiss-Str. 2-6 Tel.: +49(0) Kunststofferzeugnisse D Teningen Fax: +49(0)

Series DMHF Heat Meter

E4PA-N. Application Examples. Features. Ultrasonic Displacement Sensor. Now, more advanced with a new mutual interference prevention function.

Installation and Operating Manual FM50 IOM 2-18 DRAFT

DigitalFlow GC868 Panametrics Clamp-On Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

XONIC 100L ULTRASONIC TRANSIT-TIME FLOWMETER. User s Manual FOR LIQUID FLOW. Industrial & Military Instruments. January 2016

EM2020 Selectable AC transducer A (UK)

Ultrasonic Heat Flow Meters

Inductive Proximity Sensor

ULTRASONIC. Proximity Sensors. Series UX micro. Key-Features:

Digital Positioner 8049

Inductive displacement measurement system model series IE25P with programmable analogue interface

Threaded resistance thermometer Miniature design Model TR10-D

DWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions.

SP1 MP1 WP2 WP1. 125kHz reader models with the following prefixes: 13.56MHz reader models with the following prefixes:

Thermal Mass Flowmeter Sensyflow FMT200-D

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet

FLS M9.06. ph/orp MONITOR

FLS M9.06 PH/ORP MONITOR. safety instructions. packing List

TRANSMITTERS. HygroFlex & HygroClip-EX. Applications. Highlights

Easy Flow Indicator Magnetisch-Induktiver Durchflussmesser. Type 8024 For Insertion Fittings. Analog Flow Rate Indicator, 1/2"-16"; P=87 PSI

KOBOLD PDA Series Digital Pressure Transmitter

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline

Installing Keypad and Backplate

Hygrophil HP, type / -20

FLOW MONITOR & TRANSMITTER

CDD4 Duct Carbon Dioxide Transmitter

DEIF A/S. TAS-331DG Selectable AC transducer G (UK) Installation and start up instructions. Watt or var transducer

Temperature and humidity regulator H3020 H3021 H3023 H3027. Instruction Manual

Operating Instructions for Vibrating Level Switches. Model: NVI

Technical specification FLUXUS F501IP. Non-invasive ultrasonic flow measurement on buried pipes. Features. Applications

Electronic Temperature Switches. Catalogue. Electronic Temperature Switches. Control. Overview. every move

MDT 2000 Magnetostrictive linear position transducer

Supplementary instructions. Plug connector Harting HAN 7D. For point level sensors. Document ID: 34456

Temperature sensors TTM series. Miniature transmitters

DTE. Digital Thermometer. battery powered. Battery powered. 100 mm stainless steel case (IP 65) Configured C or F. High accuracy MAX / MIN

SONOMETER TM 500 Ultrasonic compact energy meter

ASM-IV ARGUS SURFACE METER

the Interactive Catalog

Adapter Kit - QSI Electronics to G2 Meter Installation Instructions

Ultra Sonic Flowmeter DATASHEET

Suitable for detecting transparent films or transparent bottles

WTX110. Legal-for-trade industrial weighing terminal. Special features. Data sheet

Operating Instruction

EElectronic Devices and Systems. EK-87 Electronic Volume Corrector. This product is discontinued!

Special-Purpose Proximity Sensor E2C

Accsense Wireless System. Temperature Monitor

PI 500 Hand-held instrument for industry

DATASHEET ULTRASONIC COMPACT ENERGY METER MODEL 773

Digital Air Velocity Meter DC580. The Value Leader TM

FM100 Fume hood monitoring system according to EN 14175

Level-Lance Model 5400A

VariTrans P Standard-Signal Isolators

Installing Sentor. Hardware Installation

Series TFXB Ultra. Transit Time Ultrasonic Flow Meter, Clamp-on, Liquid, Single-Channel

Adapter Kit - QSI Electronics to TM Meter Installation Instructions

Common to all H3DS. Installation of Screw-Less Clamp Models. Tools. Applicable Wires. Applicable Screwdriver. Applicable Wire Sizes

Minimum < 0.2 ms, maximum 2 ms, typical 1 ms; On request: Delays or holding times for bubble events % relative humidity (not condensing)

PU5 5-digit digital panel meter in 96x48 mm (BxH) Universal measuring inputs: Pt100, current, voltage, shunt, thermocouple, resistance

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

OPERATION & MAINTENANCE SPECIFICATIONS MANUAL 09 07

Pressure gauge for supervising cleanrooms series DMG5 Usermanual

Installation Guide DEVIlink CC Central Controller

Panorama rudder indicator TRI-2 Analogue or CAN input Approved according to MED Three extra large scales Long-life LED illumination Built-in dimmer

Plug-in unit extension block One sensor extension block allows four plug-in units to be added. Power cable for sensors. Snap-connector inputs

Transcription:

DUC-MP Quickstart A User Interface: Switch on / off. For switching off please press button for approx. 5 sec. Activates the background lighting To navigate through the different menus please use the keys located on the left and right beside the display. Move cursor in specific direction Confirm your settings Confirm your settings and moves to next menu Back to previous menu Increase of values Decrease of values XYZ Activates a certain function (depending on chosen menu) No function B Set-up your flow measurement in 5 steps 1. Choose suited mounting position for your transducers 2. Parameterize your flow transmitter 3. Mounting of ultrasonic transducers on your pipe 4. Set zero point (if possible) 5. Start your flow measurement Pipe needs to be filled completely for clamp-on measurement

C Parameterization and mounting 1. Switch on flow transmitter 2. Choose menu quick setup 3. Select diameter or circumference (depending on what figure you have) of your pipe 4. Insert value for diameter or circumference 5. Insert value for wall thickness of your pipe 6. Select pipe material 7. Select lining (if there is a lining) 8. Select type of ultrasonic transducer DUC-WP 21 DN15 DN100 DUC-WP10 DN32 DN400 DUC-WP05 DN200 DN6000 9. Select method of mounting. Standard is V-mounting. 10. Now the display is showing the required distance between the two transducers in mm and also as Index-No. Index-No. shows the distance (in holes ) when using the spacer bar. When using horizontal pipe we recommend mounting the transducers at 10 o clock or 2 o clock position to avoid any influence of gas bubbles that might accumulate on top of pipe. Straight run should be 10x diameter (inlet) and 3x diameter (outlet) in order to achieve best accuracy. Gas bubbles Mounting without spacer bar: Please use the distance given in mm. Pipe Distance is calculated from inner fronts of the 2 transducers Distance Sedimentation Mounting with spacer bar: After parameterization the display is showing the required distance between the two transducers in mm and also as Index- No. Index-No. means the number of holes to be used for mounting with the spacer bar. The first hole after the first transducers is hole No. 1, the last hole is the hole where second transducer is put into the spacer bar (threaded bar with milled screws). See picture for example. Fix transducers Please always give some coupling grease on surface of transducers before mounting. Please loosen milled screw. Please fix transducers with chains (only little contact pressure). Then screw the transducers towards pipe by using milled screw. Also only little contact pressure is required. 1 2 3 4 5 = Bar Index 5 The displayed bar index is only valid in combination with the correct space bar type (long or short) 11. Set Zero Point (if possible) If there is the chance to stop flow please do it and then select Zero Setup and set zero point. 12. Go back to main menu and select button MEAS. You then entering the measuring menu where you see the calculated flow, velocity,. Change units: ->Go to main menu and select SETUP - > COMPL SETUP. Then select UNITS SETUP to change units. Manufactured and sold by: Kobold Messring GmbH Nordring 22-24 D-65719 Hofheim Tel.: +49(0)6192-2990 Fax: +49(0)6192-23398 E-Mail: info.de@kobold.com Internet: www.kobold.com Version K01/0915

DUC-MF1 Quickstart A User Interface DUC-MF1 will be switched on automatically after supply voltage has been plugged on. Activates / deactivates the background lighting To navigate through the different menus please use the keys located on the left and right beside the display. Move cursor in specific direction Confirm your settings Confirm your settings and moves to next menu Back to previous menu Increase of values Decrease of values XYZ Activates a certain function (depending on chosen menu) No function B Set-up your flow measurement in 5 steps 1. Choose suited mounting position for your transducers 2. Parameterize your flow transmitter 3. Mounting of ultrasonic transducers on your pipe 4. Set zero point (if possible) 5. Start your flow measurement Pipe needs to be filled completely for clamp-on measurement C Parameterization and mounting 1. Switch on flow transmitter (automatically when plugging on supply voltage, see below) 2. Choose menu quick setup 3. Select diameter or circumference (depending on what figure you have) of your pipe 4. Put in value for diameter or circumference 5. Put in value for wall thickness of your pipe 6. Select pipe material 7. Select lining (if there is a lining) 8. Select type of ultrasonic transducer Nr. 1 = DUC-WF-21 DN10..DN100 Nr. 2 = DUC-WF-10 DN32..DN400 Nr. 3 = DUC-WF-05 DN200 DN6000 9. Select method of mounting. Standard is V-mounting.

10. Mount ultrasonic transducers on a pipe After parameterization the display is showing the required distance between the two transducers in mm and also as Index-No. Index-No. means the number of holes to be used for mounting with the spacer bar. The first hole after the first transducers is hole No. 1, the last hole is the hole where second transducer is put into the spacer bar (threaded bar). Picture 3 shows an example for an index- No. 4. Together with DUC-MF1 unit itself you will get one pair DUC-WF transducers and a spacer bar which matches together with the delivered DUC-WF transducers. If you have ordered more DUC-MF1 units and DUC-WF transducers for different pipe diameters it could be that you get spacer bars with different length (short or long). Pls. see in the chart below which spacer bar could be operated together with the corresponding transducer model. Spacer bar DUC-WF10 DUC-WF21 Short (25 cm) X Long (40 cm) X Picture 1 spacer bar short (length 250mm, grid hole distance 7,5mm) Picture 2 spacer bar long (length 400mm, grid hole distance 15mm) 0 1 2 3 4 Picture 3 Example distance for bar index four using spacer bar for mounting Picture 4 example for distance in mm without using spacer bar(v or W mode) face to face 11. Some acoustic coupling gel (app. size of a peanut, picture 5) or acoustic coupling foil has to be put at the part which touches the pipe wall after installation (picture 6). Acoustic coupling foil is standard. Picture 5 Using acoustic coupling gel (Magnalube) Picture 6 Using acoustic coupling foil

12. Chose best location for DUC-WF transducer installation. Straight run should be 10x diameter (inlet) and 3x diameter (outlet) in order to achieve best accuracy. When using horizontal pipe we recommend mounting the transducers at 10 o clock or 2 o clock position to avoid any influence of gas bubbles / sedimentation might accumulated on top / on bottom of pipe Pipe Gas bubbles Sedimentation Picture 6 Example Mounted Transducers with spacer bar and mounted at app. 9 o`clock 13. The transducers are fixed to the pipe by using metal belts. The metal belts are tightened by using tightener (picture in the middle). The length of the belt is designed for the biggest pipe size that the transducer can cover. So for (significantly) smaller pipes it might be reasonable to shorten the belts in order to make tightening easier. Please feed the belt into the tightener as shown in picture on the left. Proceed in the same way for PT100. Put between PT100 and surface of the pipe also acoustic coupling gel in between. After installation, PT100 should be insulated to minimize the influence of ambient air temperature. Pictures 7 Mounting DUC-WF Transducers, PT100 with stainless steel belts on a pipe 11 Set Zero Point (if possible) If there is the chance to create zero flow please select Zero Setup and set zero point. 12. Go back to main menu and select button MEAS. You enter the measuring menu where you see the calculated flow, velocity,. Change units: ->Go to main menu and select SETUP - > COMPL SETUP. Then select UNITS SETUP to change units. 13. Activate Outputs ->Go to main menu and select SETUP - > COMPL SETUP. Then select I/O-SETUP and set digital and/or analogue outputs. Please check DUC-MF1 user manual for further information. The user manual can be found as pdfdocument on the CD which is included in the delivery.

Wiring To perform the wiring it is necessary to remove the cable cover from DUC-MF1 by removing the two screws (marked with red arrows, picture 8) Picture 8 Removing cover plate from cable terminal Picture 9 screw terminals Power Supply (AC or DC pls. see type plate) For power supply please use cables with a cross section of ca. 0.5 4 mm². Solid cables should be dismantled about 8 mm to allow proper contact to terminals. I/O Terminal For I/O terminals please use cables with a cross section of ca. 0.5 2.5 mm². Solid cables should be dismantled about 6mm to allow proper contact to terminals. Terminalname Colour Description UP1 ORANGE Connection for upstream transducer Channel 1 DWN1 Connection for downstream transducer UP2 (only 2 channel version) DWN2 (only 2 channel version) RED Channel 1 Connection for upstream transducer Channel 2 Connection for downstream transducer Channel 2

PT100 No. 1 YELLOW Input for temperature sensor. Left terminal is for the colder temperature (return pipe) PT100 No. 2 Input for temperature sensor. Right terminal is for the hotter temperature (feed pipe) Relay GREEN Relay, potential-free AO1 4-20mA BLUE Analogue output 1 (4 20 ma), active, 24 VDC AO1 4-20mA Analogue output 2 (4 20m A), active, 24V DC Digital out DO1 WHITE Universal digital output 1 (transistor), for configuration of the digital outputs pls. read the user main manual. Digital out DO2 (only 2 channel version) Universal Digital output 2 (transistor), for configuration of the digital outputs pls. read the user main manual. Power Supply Please provide either 90-240 VAC or 18-36 VDC (depending on chosen model). Please make sure that you use the correct voltage. Flow transmitter might be damaged when using wrong supply. Note: All in- and outputs (except relay) have defined potential on the internal devices ground. For potential free operation of the in- and outputs is additional hardware needed (with galvanic isolation). With the normal in- and output it is not possible. Manufactured and sold by: Kobold Messring GmbH Nordring 22-24 D-65719 Hofheim Tel.: +49(0)6192-2990 Fax: +49(0)6192-23398 E-Mail: info.de@kobold.com Internet: www.kobold.com Version K01/0915

DUC-MF2 Quickstart A User Interface DUC-MF2 will be switched on automatically after supply voltage has been plugged on. Activates / deactivates the background lighting To navigate through the different menus please use the keys located on the left and right beside the display. Move cursor in specific direction Confirm your settings Confirm your settings and moves to next menu Back to previous menu Increase of values Decrease of values XYZ Activates a certain function (depending on chosen menu) No function B Set-up your flow measurement in 5 steps 1. Choose suited mounting position for your transducers 2. Parameterize your flow transmitter 3. Mounting of ultrasonic transducers on your pipe 4. Set zero point (if possible) 5. Start your flow measurement Pipe need to be filled completely for clamp-on measurement C Parameterization and mounting 1. Switch on flow transmitter (automatically when plugging on supply voltage, see below) 2. Choose menu quick setup 3. Select measurment channel 1 or 2 4. Select diameter or circumference (depending on what figure you have) of your pipe 5. Put in value for diameter or circumference 6. Put in value for wall thickness of your pipe 7. Select pipe material 8. Select lining (if there is a lining) 9. Select type of ultrasonic transducer Nr. 1 = DUC-WF21 DN10..DN100 Nr. 3 = DUC-WF10 DN32..DN400 Nr. 4 = DUC-WF05 DN200 DN6000 10. Select method of mounting. Standard is V-mounting.

11. Mount ultrasonic transducers on a pipe After parameterization the display is showing the required distance between the two transducers in mm and also as Index-No. Index-No. means the number of holes to be used for mounting with the spacer bar. The first hole after the first transducers is hole No. 1, the last hole is the hole where second transducer is put into the spacer bar (threaded bar). Picture 3 shows an example for an index- No. 4. Together with DUC-MF2 unit itself you will get one pair US- transducers an a spacer bar with matches together with the delivered US- transducers. If you have ordered more DUC-MF2 units and US- transducers for different pipe diameters it could be that you got spacer bars with different length (short or long). Pls. see in the chart below which spacer bar could be operated together with the corresponding transducer model. Spacer bar DUC-WF10 DUC-WF21 Short (25 cm) X Long (40 cm) X Picture 1 spacer bar short (length 250mm, grid hole distance 7,5mm) Picture 2 spacer bar long (length 400mm, grid hole distance 15mm) 0 1 2 3 4 Picture 3 Example distance for bar index four using spacer bar for mounting Picture 4 example for distance in mm without using spacer bar(v or W mode) face to face Some acoustic coupling gel (app. size of a peanut, picture 5) or acoustic coupling foil has to be put at the part which touches the pipe wall after installation (picture 6). Picture 5 Using acoustic coupling gel (Magnalube) Picture 6 Using acoustic coupling foil

12. Chose best location for US- transducer installation. If you install one pair of transducers on each pipe straight run should be 10x diameter (inlet) and 3x diameter (outlet) in order to achieve best accuracy. If you install 2 pairs of transducers on the same pipe it could be used to; increase accuracy, for redundant operation or to reduce effects of flow inclination (see pictures 8 and 9). It is mandatory that both transducers are installed exactly shifted about 180. When using horizontal pipe we recommend mounting the transducers at 10 o clock or 2 o clock position to avoid any influence of gas bubbles / sedimentation might accumulated on top / on bottom of pipe. Pipe Gas bubbles Sedimentation Picture 7 Example Mounted Transducers with spacer bar and mounted at app. 9 o`clock Picture 8 Example two transducer pairs on the same pipe to increase accuracy or to reduce effects of flow inclination or for redundant operation. Picture 9 Example two transducer one line. Second transducer pair lies exactly 180 shifted to the first transducer pair 13. The transducers are fixed to the pipe by using metal belts. The metal belts are tightened by using tightener (picture in the middle). The length of the belts are designed for the biggest pipe size your transducer can cover. Please feed the belt into the tightener as shown in picture on the left. Proceed in the same way for PT100. PT 100 Nr. 2 must be installed on the hotter pipe. PT Nr. 1 on the colder pipe. Put between PT100 and surface of the pipe also acoustic coupling gel in between. PT100 should after installation insulated tom minimize the influence from ambience air temperature. Pictures 10 Mounting US- Transducers, PT100 with stainless steel belts on a pipe

11 Set Zero Point (if possible) If there is the chance to create zero flow please select Zero Setup and set zero point. 12. Go back to main menu and select button MEAS. You then entering the measuring menu where you see the calculated flow, velocity,. Change units: ->Go to main menu and select SETUP - > COMPL SETUP. Then select UNITS SETUP to change units. 13. Activate Outputs ->Go to main menu and select SETUP - > COMPL SETUP. Then select I/O-SETUP and set digital and/or analog outputs. Please check DUC-MF2 user manual for further information. The user manual can be found as pdfdocument on the CD which is included in the delivery. Important Notice! Heat transfer measurement: Increasing accuracy: Reducing flow inclination Works only in operation mode (CH1+CH2)/2 Two transducers on the same pipe: Works only in operation mode (CH1+CH2)/2 Works only in operation mode (CH1+CH2)/2 Wall mount of DUC-MF2 To mount DUC-MF2 on a wall please create three boreholes corresponding to the red marked points on the drawing (all length specifications are metric).

Wiring To perform the wiring it is necessary to remove the cable cover from DUC-MF2 by removing the two screws (marked with red arrows, picture 11) Picture 11 Removing cover plate from cable terminal Picture 12 screw terminals Before you install the ultrasonic sensor cables to the measurement transducer we highly recommend pulling the sensor cable endings through the delivered ferrites. Loop the cable once as shown in the photo below (The delivered ferrite could differ from the ferrite on the photography below). Ferrite Loop Picture 13 Ferrite mounted on cable with one loop Power Supply (AC or DC pls. see type plate) For power supply please use cables with a cross section of ca. 0.5 4 mm². Solid cables should be dismantled about 8 mm to allow proper contact to terminals. I/O Terminal For I/O terminals please use cables with a cross section of ca. 0.5 2.5 mm². Solid cables should be dismantled about 6mm to allow proper contact to terminals.

Terminalname Colour Description UP1 ORANGE Connection for upstream transducer Channel 1 DWN1 Connection for downstream transducer Channel 1 UP2 RED Connection for upstream transducer Channel 2 DWN2 Connection for downstream transducer Channel 2 PT100 No. 1 YELLOW Input for temperature sensor. Left terminal is for the colder temperature (return pipe) PT100 No. 2 Input for temperature sensor. Right terminal is for the hotter temperature (feed pipe) Relay GREEN Relay, potential-free AO1 4-20 ma BLUE Analog output 1 (4 20 ma), active, 24 VDC AO1 4-20 ma Analog output 2 (4 20 ma), active, 24 VDC Digital out DO1 WHITE Universal digital output 1 (transistor), for configuration of the digital outputs pls. read the user main manual. Digital out DO2 Universal Digital output 2 (transistor), for configuration of the digital outputs pls. read the user main manual. Power Supply Please provide either 90-240 VAC or 8-36 VDC (depending on chosen model). Please make sure that you use the correct voltage. Flow transmitter might be damaged when using wrong supply. Note: All in- and outputs (except relay) have defined potential on the internal devices ground. For potential free operation of the in- and outputs is additional hardware needed (with galvanic isolation). With the normal in- and output it is not possible. Manufactured and sold by: Kobold Messring GmbH Nordring 22-24 D-65719 Hofheim Tel.: +49(0)6192-2990 Fax: +49(0)6192-23398 E-Mail: info.de@kobold.com Internet: www.kobold.com Version K01/0915

DUC-ZUWD Quickstart Prepare your wall thickness gauge /Keypad definition The delivery is usually ready to use; batteries (AA). Switch on / off Exit Enter Backlight on / off Scroll down / decrease Menu / Select Calibration 3 steps to parameterize your wall thickness gauge Scroll up/ Increase Connect the signal cables of the transducer to the thickness gauge 1. Please check if the sensor probe type is set correctly (standard type N07 ) 2. Make calibration using integrated calibration sample Calibration sample 3. Set value for speed of sound of your pipe material. 4. Place probe on the pipe and get reading for wall thickness Please make sure to put some coupling grease on the sensor tip before measurement. Calibration should be repeated each time you start new measurement. Calibration should be done at speed of sound of 5920 m/s Pic. 1 Pic. 2 Pic. 4 Pic. 3 Put some coupling grease (Magnalube) on the probe tip (Pic.1). Put sensor on the integrated calibration sample (Pic.2) which you find in the lowermost right corner of the instrument. Press button. Display will show 4.00 mm. Remove the probe. Your DUC-ZUWD is now calibrated. Now set the speed of sound of media of pipe material. Press button (4x) to go to menu for setting of speed of sound. (lowermost line, right corner), see pic.3. The value can be changed by using buttons. Values for typical materials can be obtained from the adjacent table. Put sensor tip on your pipe and take readings from display, see pic.4. Manufactured and sold by: Kobold Messring GmbH Nordring 22-24 D-65719 Hofheim Tel.: +49 (0)6192-2990 Fax: +49(0)6192-23398 E-Mail: info.de@kobold.com Internet: www.kobold.com Version K01/1115