CFO100 Series. User Manual CRT141 & CRR141. CFO141 User Manual, , rev001

Similar documents
One and four channel video links

One, four and eight channel video links

CEV 4 and 8 channel CWDM video modem

FVT/FVR20D2I1C4E INSTALLATION AND OPERATION MANUAL

Single Channel Video Insert Unit with Bi-directional Data Channel for a Dual Redundant fibre ring

FVT/FVR10D1E(M,S)[M] 10-BIT DIGITALLY ENCODED VIDEO TRANSMITTER WITH 1 BI-DIRECTIONAL DATA CHANNEL AND 10/100MB ETHERNET

8 Channel Video Receive Unit with 2 Bi-directional Data and Audio Channels plus Ethernet for a Dual Redundant multimode fibre ring.

Data Insert Unit with 2 Bi-directional Data Channels for a Dual Redundant Singlemode Fibre Ring

OPERATOR MANUAL OSD8826 SERIES DIGITAL VIDEO AND DATA FIBER OPTIC TRANSMISSION SYSTEM

The AMG5715A1B9 is designed to be powered using an AMG2001 standalone power supply.

FVT/FVR110(M,S)1[/M] 10-BIT DIGITAL VIDEO WITH ONE BI-DIRECTIONAL DATA CHANNEL INSTALLATION AND OPERATION MANUAL

8 Channel Video Transmit Unit with 9 Bi-directional Data and Audio Channels and Ethernet for a Multimode Fibre Link

FIBER OPTIC TRANSMISSION SYSTEM 3730 & 3530 SERIES. Digital Video with Bi-directional/Return Data. User Manual. Infinova

8 Channel Video Transmit Unit with 1 Bi-directional Data Channel for a Singlemode Fibre Link

OPERATOR MANUAL OSD730 FULL DUPLEX FOUR CHANNEL DIGITAL AUDIO/DATA SYSTEM

8 Channel Video Transmit Unit with 1 Bi-directional Data Channel for a Singlemode Fibre Link

OPERATOR MANUAL OSD157 FIBER OPTIC RS422/RS232 MODEM/MULTIPLEXER

Serial Data DIN Fiber Link System

MULTIDYNE INNOVATIONS IN TELEVISION TESTING & DISTRIBUTION INSTRUCTION MANUAL FMX-125

4 Channel Video Receive Unit with Bi-directional Data Channel and Ethernet for a Singlemode Fibre Link

OPERATOR MANUAL OSD840 SERIES DIGITAL VIDEO, ETHERNET, DATA AND AUDIO FIBER OPTIC TRANSMISSION SYSTEM

RER 123 Bus Connection Module. Technical Description

F8008. Fiber Modem for up to 4E1 /8E1 +RS232+Ethernet. + optional V.35/QFXS/QFXO

Instruction Manual RR-915C Video Receiver With Bi-directional Multi-Protocol Data And Bi-directional Contact Closure

Fiber optic converter audio and CAN TA OPERATION MANUAL

OPERATOR MANUAL OSD860S SERIES REDUNDANT LINK DIGITAL 4/8 CHANNEL VIDEO/AUDIO/DATA/IP FIBER OPTIC MULTIPLEXER

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

INDUSTRIAL POE SWITCH

Instruction Manual RT-91685SL RR-91685SL Sixteen Channel Video Multiplexer With Two Bi-directional Data Channels

8 Channel Video Transmit Unit with Bi-directional Data Channel and Ethernet for a Multimode Fibre Link

Dual Channel Video Insert Unit with Ethernet for a Dual Redundant fibre ring

LASER PLUS OPERATING INSTRUCTIONS

OPERATOR MANUAL OSD156 SYNCHRONOUS FIBER OPTIC RS232 MODEM

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

RS-232 Industrial Media Converter

CMU 100 RS232 to Singlemode Fiber Optic Converter User Manual

FL MC 2000E (SM40) LC

OPERATOR MANUAL OSD860 SERIES DIGITAL 2/4/8 CHANNEL VIDEO/AUDIO/DATA/IP FIBER OPTIC MULTIPLEXER

OPERATOR MANUAL OSD136 SYNCHRONOUS FIBER OPTIC RS232 MODEM

Network Video Recorder Quick Operation Guide

OPERATOR MANUAL OSD461A/OSD463A AUDIO FIBER OPTIC TRANSMISSION SYSTEM

RS-232 Fiber Link Card System

2 Channel POTS DIN Fiber Link System

OPERATOR MANUAL OSD420 SERIES VIDEO, AUDIO AND DATA FIBER OPTIC TRANSMISSION SYSTEM

Table of Contents. Functional Description Installation Power Source Power Connection Fiber Connection... 4

4 Channel Video Insert Unit with Ethernet for a Dual Redundant Single Fibre Ring

DS-6600HFHI (/L) Series HD Audio / Video Encoder. Quick Operation Guide V1.0.0

0.25m long cable directly out of the sensor. Blue laser line (405nm) for (semi-) transparent, red-hot glowing and organic materials

Single Channel FM Video Transmission System 850 nm Multimode Low Profile

ICPDAS FSM-510G Series Ethernet Management Switch Quick Start

Technical data. General specifications. Indicators/operating means

4 Channel Video Receive Unit with up to 8 Bi-directional Data and Audio Channels plus Ethernet

Operating Instruction for IQ Series laser diode module Instructions for IQ1C, IQ2C, IQ4C, IQ6, IQ7, IQ1A, IQ2A, IQ4A, IQ1H, IQ2H and IQ4H

Modular E1 or Fractional E1 Access Unit. Dial-out for alarm report The E1 main link can be supplied with the following options:

E101 - Strain Gauge Transducer Display Module. Contents

The AMG5716A9 is designed to be powered using an AMG2001 standalone power supply.

W&T. Universal Fiber Optic Interface Converter W&T. Manual. Universal FO Interface Converter. Model Release 1.0. Subject to error and alteration

8~14-Port Managed Ethernet Switch

The AMG5616A6R is designed to plug into an AMG2005 or AMG2009 subrack, which in turn fits into a 19" rack system.

POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

USER MANUAL. SATEL i-link. I/O-converter. Version 1.4

Hardware User s Manual. Digital Video Motion Detector DVMD1-X

PM Series Matrix Router Owner s Manual

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual

Manual Fiber Optic Interfaces

Analog Input and Output Options for Syringe Pumps

OPERATOR MANUAL OSD139A ASYNCHRONOUS FIBER OPTIC RS232 MODEM

CMU 100 Multimode Fiber Optic to Singlemode Fiber Optic Converter User Manual

LegacyPlus 7-OR SERIES RETURN TRANSMITTER INSTRUCTION MANUAL 7-OR-RT/xxx

Rugged MediaConverter

HD-3500 Series. HD Video, Audio, Data & Tally/GPIO Channels FEATURES

Ultra Low Noise Laser 1550nm

The AMG5903A966 is designed to be powered using an AMG2003 standalone or equivalent power supply.

The SilverNugget is a servo controller/driver for NEMA 17 & 23 frame microstep motors.

8 Chanel HD SDI Over Fiber. Transmitter and Reciever Extender. User Manual L-8SDI-FE-HD-TX/RX

RS 232 to Fibre Optic Modems ELO E240, ELO E241, ELO E242. Operation manual

INSTALLATION INSTRUCTIONS. ACB-100 Audio Control Board. This document describes the installation procedure for the ACB-100 Audio Control Board.

P/N Operation & Installation Manual Serial Control Transfer Switch Model TM-STS

FSM-510G Series Ethernet Management Switch Quick Start Guide

AFO485 : FIBRE OPTIC MODEM RFO485 : FIBRE OPTIC REPEATER. USER GUIDE Doc. ref : Distribué par : Contact :

4 Channel DMX Driver Instruction Manual

TCF-142-RM Series Hardware Installation Guide

6100E Series DIGITAL FIBER OPTIC MULTI-CHANNEL AUDIO TRANSPORT SYSTEM

Loop-O 9300 Fiber Optical Mux

User Manual Controller. Automation and Router Control.

NPort 6600 Series Quick Installation Guide

NTSC TOA's Digital Video Recorder series combine high reliability with all the advantages of scalable expansion flexibility.

Network audio encoder / decoder with I/O for professional and broadcast applications

MGate MB3170/MB3270 Quick Installation Guide

FL SWITCH SFN(T) 16-Port Standard Function Ethernet Switches for Normal and Extreme Environments. AUTOMATION Data Sheet 2806_en_C

MSR 2400W. Multi purpose Power System for Telecom and Industrial Applications. Nominal Output Voltage. Voltage Setting Range

Prisma II Platform. Optoelectronics

Optimux-4T1 Four-Channel T1 Multiplexer

The sensor fulfills the specifications of the EMC requirements, if the instructions in the manual are followed.

Butterfly Laser Diode Mount

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

Ver. 2.0en 1550nm CATV Erbium Doped Fiber Amplifier EDFA-4429 Series USER MANUAL

4K HDMI & USB/AUDIO/RS232/IR CAT5e Extender ITEM NO: SE150HX-4K HDMI & USB/ Audio/RS232/IR CAT5e Extender

Installation/assembly manual for DCC/Power shield

Transcription:

CFO00 Series User Manual CRT4 & CRR4 CFO4 User Manual, 5930005, rev00

Contents Introduction... Optical Transmitter CRT4 (version B)...2 General...2 Frame Installation...2 Video Input and Indicator Led...2 Stand-Alone Installation...3 Data Connections...4 Management (MGMT) Data Connection...5 Audio Connection...6 Contact Closure Loop (CCL) Connection...7 Link Status and Module Indicator Leds...8 Alarm Connections...8 Video Source Alarm (VSA)...9 Fibre Connection...9 Optical Receiver CRR4 (version B)...0 General...0 Frame Installation...0 Video Output and Indicator Led...0 Stand-Alone Installation... Data Connections...2 Management (MGMT) Data Connection...3 Audio Connection...4 Contact Closure Loop (CCL) Connection...5 Link Status and Module Indicator Leds...6 Alarm Connections...6 Video Source Alarm (VSA)...7 Fibre Connection...7 Copyright Acknowledgements...8 CFO4 Series User Manual rev00

CFO4 Single mode Channel Digital Units for Uni-directional Video and Bi-directional Audio, Data & Contact Closure, In-band Management Introduction The CFO4 is a uni-directional video channel link with two bi-directional data, one bi-directional audio and one bi-directional contact closure channels. PAL, NTSC and SECAM video formats are supported to provide a transparent video transmission. All common data protocols are supported as well and are easily confi gured by terminal software interface. Optical transmission is based on a FP LASER operation. The multiplexed data stream of 540 Mb/s enables a full quality and a real-time video transmission in one singlemode fiber up to 50km typical transmission distance. All CFO4 units are compatible with all CFO rack systems. Stand-alone options are available with the CMA02 module adapter and a separate mains adapter. CRT4 Transmitter Video MGMT (RS232) MGMT (RS232) Audio (600 Ω/High) Audio (0 Ω) Data (RS232) Data (RS232) Data 2 (TTL/RS485/RS422) Data 2 (TTL/RS485/RS422) CC CC/VSA bit rate 3.5 Mbps 30 nm singlemode optical fibre link budget 20 db bit rate 540 Mbps CRR4 Receiver Video MGMT (RS232) MGMT (RS232) Audio (0 Ω) Audio (600 Ω/High) Data (RS232) Data (RS232) Data 2 (TTL/RS485/RS422) Data 2 (TTL/RS485/RS422) CC/VSA CC CFO4 Series User Manual rev00

OPTICAL TRANSMITTER CRT4 (version B) CAUTION: THIS OPTICAL UNIT USES CLASS LASER DIODE. DO NOT STARE INTO BEAM OR VIEW DIRECTLY WITH OPTICAL INSTRUMENTS. APPLICABLE STANDARD IEC825-2: 993 front view GENERAL 2 VIDEO OPTICAL TRANSMITTER CCL DATA AUDIO MGMT IN OUT IN OUT 600 OVL IN OUT 5 6 7 8 The CRT4 is a one channel optical transmitter for unidirectional video transmission with two bi-directional data, one audio and one contact closure channel in a singlemode fi bre. The current consumption is (max) 600 ma (+ 2V DC). FRAME INSTALLATION The module is to be pushed along the guide rails into the installation frame (e.g. CSR26 or 36 series) and secured with the locking screws (4 pcs). The unit can be freely positioned in any slot in the frame. The empty positions in the frame should be blanked off with cover plates. The supply voltage is to be provided by a CPS384 power supply unit. 3 LINK STATUS MODULE VIDEO INPUT AND INDICATOR LED 4 The impedance of the video input (BNC female) is 75 Ω. The nominal input level is Vpp. Picture. CRT4 Optical Transmitter ) Locking screw. 2) Video input (BNC female) and video indicator (led). 3) Optical input/output (FC/PC). 4) Handle. 5) MGMT connector (RJ-45 female). 6) AUDIO connector (RJ-45 female). 7) DATA connector (RJ-45 female). 8) CCL connector (RJ-45 female). Video input is equipped with the dual colour VIDEO led on the front panel. In case a video signal is present and in nominal level (and the unit detects video synchronization pulses), the VIDEO led is green. If there is no video signal, or the video level is too low, the VIDEO led is yellow. 2 CFO4 Series User Manual rev00

2 3 4 5 CONTROL BUS RF CONTROL/ ALARM POWER rear view 2 6 + 2 V GND Picture 2. CMA02 Module Adapter ) Control bus for management systems (RJ-45 female), not in use. 2) RF output connectors, not in use. 3) Control / alarm interface connector (HD5 female). 4) Grounding connection. 5) Supply voltage connector. STAND-ALONE INSTALLATION The unit can be installed for stand-alone use by using a CMA02 module adapter (see picture 2). The module should be mounted to a vertical surface. The 2V DC supply voltage is supplied by the means of a separate mains adapter with a regulated output, (e.g. CPS22). The permitted supply voltage range is 0.5...4V DC. The permitted operational temperature range is from 0 to +70 C. Pin Signal Not used 2 Not used 3 Not used 4 Not used 5 +2 V DC output 6 A - alarm 7 B - alarm 8 CTRL (CFO address bus data) 9 CTRL2 (CFO address bus clk) 0 Ground Not used 2 Not used 3 Not used 4 Not used 5 Not used Table. Pin information for the HD5 female connector of the CMA02 module adapter (with CRT4 installed). CFO4 Series User Manual rev00 3

DATA OUT IN Picture 3. The DATA connector (RJ-45 female). DATA OUT led indicates status of (data ch 2) outgoing data signal and DATA IN led indicates status of (data ch 2) incoming data signal. Pin Wire color White / green stripe 2 Green 3 White / orange stripe 4 Blue 5 White / blue stripe 6 Orange 7 White / brown stripe 8 Brown Table 2. CIC603 cable s pinout / wire colors (RJ-45 male / open wires). 8 DATA CONNECTIONS The DATA connector contains two bi-directional data channels (CRT <--> CRR). The connector in use is a RJ-45 female connector (see picture 3 and table 3 for detailed description). The recommended cable for DATA connection is CIC603 (RJ-45/open wires, see table 2 for detailed description). Data channel is always in RS232 mode. The desired data mode for data channel 2 can be selected by using a PC and any terminal type communication software (see separate documentation for CFO4 terminal software). See table 4 for available data modes for data channel 2. The default factory settings are RS485-2w + Dwell time 75µs. The DATA IN/OUT leds indicates the status of data (ch 2) stream and they are also operating synchronously with the data stream. See table 5 for explanation of DATA connector s leds. Pin Signal TTL RS422 RS485-2w RS485-4w RS232 Data 2 in (-) in / out (-) in (-) 2 Data 2 in in (+) in / out (+) in (+) 3 Data 2 out (+) out (+) 4 Data 2 out 5 Ground 6 Data 2 out (-) out (-) 7 Data out 8 Data in Table 3. DATA connector s pinout (RJ-45 female). Mode TTL RS422 RS485-2w RS485-4w Input termination options None No term (only failsafe) Hard bias Line bias (20 Ω line impedance) No term (only failsafe) + Dwell time adjustable 50...0000µs Hard bias Line bias (20 Ω line impedance) No term (only failsafe) Hard bias Line bias (20 Ω line impedance) Table 4. Available datamodes for data channel 2. Led DATA OUT DATA IN Colour Status Green Data Yellow Data 0 Green Data Yellow Data 0 Table 5. DATA connector (RJ-45 female) / indicator leds. 4 CFO4 Series User Manual rev00

MGMT OUT IN Picture 4. The MGMT connector (RJ-45 female). MGMT OUT led indicates status of outgoing MGMT data signal and MGMT IN led indicates status of incoming MGMT data signal. Pin RJ-45 D9 - - 2 MGMT out MGMT in 3 MGMT in MGMT out 4 - - 5 Ground Ground 6 - - 7 - - 8 - - 9 - Table 6. CIC503 cable s pinout (RJ-45 male / D9 female). 8 MANAGEMENT (MGMT) DATA CONNECTION The MGMT connector contains one bi-directional MGMT data channel (RS232). The MGMT connection allows locally or remotely (in-band connection via fibre) configuration and monitoring of CFO4 unit by using a PC and any terminal type communication software (see separate documentation for CFO4 terminal software). The connector in use is a RJ-45 female connector (see picture 4 and table 7 for detailed description). The recommended cable for MGMT connection is CIC503 (RJ-45 male/d9 female, see table 6 for detailed description). The MGMT IN/OUT leds indicates the status of MGMT data stream and they are also operating synchronously with the data stream. See table 8 for explanation of MGMT connector s leds. Pin Signal Ground 2 MGMT out (RS232) 3 MGMT in (RS232) 4 Ground 5 Ground 6 Ground 7 Ground 8 Ground Table 7. MGMT connector s pinout (RJ-45 female). Led MGMT OUT MGMT IN Colour Status Green Data Yellow Data 0 Green Data Yellow Data 0 Table 8. MGMT connector (RJ-45 female) / indicator leds. CFO4 Series User Manual rev00 5

AUDIO OVL 600 Picture 5. The AUDIO connector (RJ-45 female). AUDIO OVL led indicates status of audio signal level and AUDIO 600 led indicates status of audio input impedance. Pin Wire color White / green stripe 2 Green 3 White / orange stripe 4 Blue 5 White / blue stripe 6 Orange 7 White / brown stripe 8 Brown Table 9. CIC603 cable s pinout / wire colors (RJ-45 male / open wires). 8 AUDIO CONNECTION The AUDIO connector contains one bi-directional audio channel line (CRT <--> CRR). The audio input impedance can be set to high impedance (>0 kω) or 600 Ω by using a PC and any terminal type communication software (see separate documentation for CFO4 terminal software). The default factory setting foris 600 Ω. The audio output impedance is constant and cannot be adjusted. The audio output impedance is 0 Ω. The connector in use is a RJ-45 female connector (see picture 5 and table 0 for detailed description) and the cable in use is e.g. CIC603 (RJ-45/open wires, see table 9 for detailed description). The AUDIO 600 led indicates the status of audio impedance and the AUDIO OVL led indicates the status of audio level. See table for explanation of AUDIO connector s leds. Pin Signal Ground 2 Ground 3 Audio output + 4 Audio output - 5 Ground 6 Ground 7 Audio input + 8 Audio input - Table 0. AUDIO connector s pinout (RJ-45 female). Led AUDIO OVL AUDIO 600 Color Green Yellow No light Green Yellow Table. AUDIO connector (RJ-45 female) / indicator leds. Status Audio signal level is good Audio signal level is too high Audio signal is missing Audio input impedance is 600 Ω Audio input impedance is >0 kω 6 CFO4 Series User Manual rev00

CCL OUT IN Picture 6. The CCL connector (RJ-45 female). CCL OUT led indicates status of CCL output signal and CCL IN led indicates status of CCL input signal. Pin Wire color White / green stripe 2 Green 3 White / orange stripe 4 Blue 5 White / blue stripe 6 Orange 7 White / brown stripe 8 Brown Table 2. CIC603 cable s pinout / wire colors (RJ-45 male / open wires). 8 CONTACT CLOSURE LOOP (CCL) CONNECTION The CCL connector contains one bi-directional contact closure channel line (CRT <--> CRR). The CCL input/output is a normal dry contact closure on/off - signal between connector s contact pins. The connector in use is a RJ-45 female connector (see picture 6 and table 3 for detailed description) and the cable in use is e.g. CIC603 (see table 2 for detailed description). The CCL IN/OUT leds indicates the status of CCL connection. See table 4 for explanation of CCL connector s leds. The CCL output channel can be alternatively configured for VSA usage (see page 9). The default factory setting is CCL usage (CC=CC). Pin Signal Ground 2 Ground 3 CCL output (output relay) 4 CCL output (output relay) 5 Ground 6 Ground 7 NC 8 CCL input (photodiode cathode) Table 3. CCL connector s pinout (RJ-45 female). Led CCL OUT Color Green Yellow Status CCL output is closed CCL output is open CCL IN Green CCL input is closed (pin 8 to ground) Yellow CCL input is open Table 4. CCL connector s leds / indicator lights (RJ-45 female). CFO4 Series User Manual rev00 7

LINK STATUS AND MODULE INDICATOR LEDS When the optical input signal level is adequate and in syncronization to input data is achieved, the LINK STATUS led on the front panel is green. If optical input signal level is adequate, but no syncronization is achieved the LINK STATUS led blinks green/yellow. If optical input signal is missing or it s level is too low, the the LINK STATUS led is yellow. When the supply voltage is not in the permitted range (0.5...4 V DC) or there is a transmitter laser failure, the MODULE led colour on the front panel is red. When the unit s temperature is not in the permitted range, the MODULE led blinks green/red. During normal operation MODULE led is blinking green (blinking indicates embedded software is working properly). ALARM CONNECTIONS All alarms at the rear connector of the unit are low open collector outputs, with the capability of 30 V/0 ma switching. Alarm Description Reason A Hardware failure TX laser failure Supply voltage is not in the permitted range B Link status alarm Input optical signal is too low No syncronisation archieved to input data Table 5. Open collector alarms. Note! At the rear of unit is located a DIP switch for factory use only (see picture below). If this switch is set to Reset (upper position), the unit goes to programming state and then has no normal operation. Default factory setting is Normal (lower position). VIDEO Note! This DIP switch at rear connector is for factory use only. If this switch is set to "Reset" (upper position), the unit goes to "programming state" and then has no normal operation. Default factory setting is "Normal" (lower position). Switch exists in all units (CRT & CRR). Reset Normal 8 CFO4 Series User Manual rev00

top view VIDEO SOURCE ALARM (VSA) The CCL output channel can be alternatively configured for VSA usage. When VSA mode is enabled and CRT s video input is missing (link otherwise operates normally, but e.g. only the camera is broken), the CCL OUT led blinks yellow and CCL output pins are closed. VSA have no effect to CRT s CCL input i.e. it can be used normally to transmit CCL information to CRR if VSA is not activated at CRR. In case when VSA is enabled at the same time in both CRT and CRR, then CCL channels are not available for other use. The VSA function can be set on/off by using a PC and any terminal type communication software (see separate documentation for CFO4 terminal software). The default factory setting is CCL usage (CC=CC). See table 6 for explanation of CCL connector s OUT led when VSA function is set active. Picture 7. FC/PC Connectors Make sure the key is aligned in the slot properly before tightening! Note! Video detection has 20 sec delay before VIDEO SOURCE ALARM is activated / inactivated. Led CCL OUT Color Green on/off blinking Yellow on/off blinking Status Video OK Video missing Table 6. CCL connector (RJ-45 female) / CCL OUT indicator led when VSA is enabled. FIBRE CONNECTION The optical connector is of the type FC/PC (see picture 7). The optical output level is constant and cannot be adjusted. The nominal optical output level is dbm (maximum optical input level for return signal is - dbm). The link budget for both transmission directions is 20 db. The operating wavelenght is 30 nm. When installing the fibre optic cable, do not exceed the minimum bending radius when connecting cable to the system. Note! For correct optical operation ensure that all optical connectors are cleaned immediately before mating. Connectors should always be cleaned using high purity alcohol (e.g. methyl or isopropyl alcohol). Dry the surfaces using clean compressed air or other equivalent pressurised gas. The optical connectors on the equipment should always be protected with dustcaps when there is no fi bre inserted. CFO4 Series User Manual rev00 9

OPTICAL RECEIVER CRR4 (version B) CAUTION: THIS OPTICAL UNIT USES CLASS LASER DIODE. DO NOT STARE INTO BEAM OR VIEW DIRECTLY WITH OPTICAL INSTRUMENTS. APPLICABLE STANDARD IEC825-2: 993 front view GENERAL 2 VIDEO OPTICAL RECEIVER CCL DATA AUDIO MGMT IN OUT IN OUT 600 OVL IN OUT 5 6 7 8 The CRR4 is a one channel optical receiver for unidirectional video transmission with two bi-directional data, one audio and one contact closure channel in a singlemode fi bre. The current consumption is (max) 600 ma (+ 2V DC). FRAME INSTALLATION The module is to be pushed along the guide rails into the installation frame (e.g. CSR26 or 36 series) and secured with the locking screws (4 pcs). The unit can be freely positioned in any slot in the frame. The empty positions in the frame should be blanked off with cover plates. The supply voltage is to be provided by a CPS384 power supply unit. 3 LINK STATUS MODULE VIDEO OUTPUT AND INDICATOR LED 4 The impedance of the video output (BNC female) is 75 Ω. The nominal output level is Vpp. Picture. CRR4 Optical Receiver ) Locking screw. 2) Video output (BNC female) and video indicator (led). 3) Optical input/output (FC/PC). 4) Handle. 5) MGMT connector (RJ-45 female). 6) AUDIO connector (RJ-45 female). 7) DATA connector (RJ-45 female). 8) CCL connector (RJ-45 female). Video output is equipped with the dual colour VIDEO led on the front panel. In case a video signal is present and in nominal level (and the unit detects video synchronization pulses), the VIDEO led is green. If there is no video signal, or the video level is too low, the VIDEO led is yellow. 0 CFO4 Series User Manual rev00

2 3 4 5 CONTROL BUS RF CONTROL/ ALARM POWER rear view 2 6 + 2 V GND Picture 2. CMA02 Module Adapter ) Control bus for management systems (RJ-45 female), not in use. 2) RF output connectors, not in use. 3) Control / alarm interface connector (HD5 female). 4) Grounding connection. 5) Supply voltage connector. STAND-ALONE INSTALLATION The unit can be installed for stand-alone use by using a CMA02 module adapter (see picture 2). The module should be mounted to a vertical surface. The 2V DC supply voltage is supplied by the means of a separate mains adapter with a regulated output, (e.g. CPS22). The permitted supply voltage range is 0.5...4V DC. The permitted operational temperature range is from 0 to +70 C. Pin Signal Not used 2 Not used 3 Not used 4 Not used 5 +2 V DC output 6 A - alarm 7 B - alarm 8 CTRL (CFO address bus data) 9 CTRL2 (CFO address bus clk) 0 Ground Not used 2 Not used 3 Not used 4 Not used 5 Not used Table. Pin information for the HD5 female connector of the CMA02 module adapter (with CRR4 installed). CFO4 Series User Manual rev00

DATA OUT IN Picture 3. The DATA connector (RJ-45 female). DATA OUT led indicates status of (data ch 2) outgoing data signal and DATA IN led indicates status of (data ch 2) incoming data signal. Pin Wire color White / green stripe 2 Green 3 White / orange stripe 4 Blue 5 White / blue stripe 6 Orange 7 White / brown stripe 8 Brown Table 2. CIC603 cable s pinout / wire colors (RJ-45 male / open wires). 8 DATA CONNECTIONS The DATA connector contains two bi-directional data channels (CRT <--> CRR). The connector in use is a RJ-45 female connector (see picture 3 and table 3 for detailed description). The recommended cable for DATA connection is CIC603 (RJ-45/open wires, see table 2 for detailed description). Data channel is always in RS232 mode. The desired data mode for data channel 2 can be selected by using a PC and any terminal type communication software (see separate documentation for CFO4 terminal software). See table 4 for available data modes for data channel 2. The default factory settings are RS485-2w + Dwell time 75µs. The DATA IN/OUT leds indicates the status of data (ch 2) stream and they are also operating synchronously with the data stream. See table 5 for explanation of DATA connector s leds. Pin Signal TTL RS422 RS485-2w RS485-4w RS232 Data 2 in (-) in / out (-) in (-) 2 Data 2 in in (+) in / out (+) in (+) 3 Data 2 out (+) out (+) 4 Data 2 out 5 Ground 6 Data 2 out (-) out (-) 7 Data out 8 Data in Table 3. DATA connector s pinout (RJ-45 female). Mode TTL RS422 RS485-2w RS485-4w Input termination options None No term (only failsafe) Hard bias Line bias (20 Ω line impedance) No term (only failsafe) + Dwell time adjustable 50...0000µs Hard bias Line bias (20 Ω line impedance) No term (only failsafe) Hard bias Line bias (20 Ω line impedance) Table 4. Available datamodes for data channel 2. Led DATA OUT DATA IN Colour Status Green Data Yellow Data 0 Green Data Yellow Data 0 Table 5. DATA connector (RJ-45 female) / indicator leds. 2 CFO4 Series User Manual rev00

MGMT OUT IN Picture 4. The MGMT connector (RJ-45 female). MGMT OUT led indicates status of outgoing MGMT data signal and MGMT IN led indicates status of incoming MGMT data signal. Pin RJ-45 D9 - - 2 MGMT out MGMT in 3 MGMT in MGMT out 4 - - 5 Ground Ground 6 - - 7 - - 8 - - 9 - Table 6. CIC503 cable s pinout (RJ-45 male / D9 female). 8 MANAGEMENT (MGMT) DATA CONNECTION The MGMT connector contains one bi-directional MGMT data channel (RS232). The MGMT connection allows locally or remotely (in-band connection via fibre) configuration and monitoring of CFO4 unit by using a PC and any terminal type communication software (see separate documentation for CFO4 terminal software). The connector in use is a RJ-45 female connector (see picture 4 and table 7 for detailed description). The recommended cable for MGMT connection is CIC503 (RJ-45 male/d9 female, see table 6 for detailed description). The MGMT IN/OUT leds indicates the status of MGMT data stream and they are also operating synchronously with the data stream. See table 8 for explanation of MGMT connector s leds. Pin Signal Ground 2 MGMT out (RS232) 3 MGMT in (RS232) 4 Ground 5 Ground 6 Ground 7 Ground 8 Ground Table 7. MGMT connector s pinout (RJ-45 female). Led MGMT OUT MGMT IN Colour Status Green Data Yellow Data 0 Green Data Yellow Data 0 Table 8. MGMT connector (RJ-45 female) / indicator leds. CFO4 Series User Manual rev00 3

AUDIO OVL 600 Picture 5. The AUDIO connector (RJ-45 female). AUDIO OVL led indicates status of audio signal level and AUDIO 600 led indicates status of audio input impedance. Pin Wire color White / green stripe 2 Green 3 White / orange stripe 4 Blue 5 White / blue stripe 6 Orange 7 White / brown stripe 8 Brown Table 9. CIC603 cable s pinout / wire colors (RJ-45 male / open wires). 8 AUDIO CONNECTION The AUDIO connector contains one bi-directional audio channel line (CRT <--> CRR). The audio input impedance can be set to high impedance (>0 kω) or 600 Ω by using a PC and any terminal type communication software (see separate documentation for CFO4 terminal software). The default factory setting foris 600 Ω. The audio output impedance is constant and cannot be adjusted. The audio output impedance is 0 Ω. The connector in use is a RJ-45 female connector (see picture 5 and table 0 for detailed description) and the cable in use is e.g. CIC603 (RJ-45/open wires, see table 9 for detailed description). The AUDIO 600 led indicates the status of audio impedance and the AUDIO OVL led indicates the status of audio level. See table for explanation of AUDIO connector s leds. Pin Signal Ground 2 Ground 3 Audio output + 4 Audio output - 5 Ground 6 Ground 7 Audio input + 8 Audio input - Table 0. AUDIO connector s pinout (RJ-45 female). Led AUDIO OVL AUDIO 600 Color Green Yellow No light Green Yellow Table. AUDIO connector (RJ-45 female) / indicator leds. Status Audio signal level is good Audio signal level is too high Audio signal is missing Audio input impedance is 600 Ω Audio input impedance is >0 kω 4 CFO4 Series User Manual rev00

CCL OUT IN Picture 6. The CCL connector (RJ-45 female). CCL OUT led indicates status of CCL output signal and CCL IN led indicates status of CCL input signal. Pin Wire color White / green stripe 2 Green 3 White / orange stripe 4 Blue 5 White / blue stripe 6 Orange 7 White / brown stripe 8 Brown Table 2. CIC603 cable s pinout / wire colors (RJ-45 male / open wires). 8 CONTACT CLOSURE LOOP (CCL) CONNECTION The CCL connector contains one bi-directional contact closure channel line (CRT <--> CRR). The CCL input/output is a normal dry contact closure on/off - signal between connector s contact pins. The connector in use is a RJ-45 female connector (see picture 6 and table 3 for detailed description) and the cable in use is e.g. CIC603 (see table 2 for detailed description). The CCL IN/OUT leds indicates the status of CCL connection. See table 4 for explanation of CCL connector s leds. The CCL output channel can be alternatively configured for VSA usage (see page 7). The default factory setting is CCL usage (CC=CC). Pin Signal Ground 2 Ground 3 CCL output (output relay) 4 CCL output (output relay) 5 Ground 6 Ground 7 NC 8 CCL input (photodiode cathode) Table 3. CCL connector s pinout (RJ-45 female). Led CCL OUT Color Green Yellow Status CCL output is closed CCL output is open CCL IN Green CCL input is closed (pin 8 to ground) Yellow CCL input is open Table 4. CCL connector s leds / indicator lights (RJ-45 female). CFO4 Series User Manual rev00 5

LINK STATUS AND MODULE INDICATOR LEDS When the optical input signal level is adequate and in syncronization to input data is achieved, the LINK STATUS led on the front panel is green. If optical input signal level is adequate, but no syncronization is achieved the LINK STATUS led blinks green/yellow. If optical input signal is missing or it s level is too low, the the LINK STATUS led is yellow. When the supply voltage is not in the permitted range (0.5...4 V DC) or there is a transmitter laser failure, the MODULE led colour on the front panel is red. When the unit s temperature is not in the permitted range, the MODULE led blinks green/red. During normal operation MODULE led is blinking green (blinking indicates embedded software is working properly). ALARM CONNECTIONS All alarms at the rear connector of the unit are low open collector outputs, with the capability of 30 V/0 ma switching. Alarm Description Reason A Hardware failure TX laser failure Supply voltage is not in the permitted range B Link status alarm Input optical signal is too low No syncronisation archieved to input data Table 5. Open collector alarms. Note! At the rear of unit is located a DIP switch for factory use only (see picture below). If this switch is set to Reset (upper position), the unit goes to programming state and then has no normal operation. Default factory setting is Normal (lower position). VIDEO Note! This DIP switch at rear connector is for factory use only. If this switch is set to "Reset" (upper position), the unit goes to "programming state" and then has no normal operation. Default factory setting is "Normal" (lower position). Switch exists in all units (CRT & CRR). Reset Normal 6 CFO4 Series User Manual rev00

top view VIDEO SOURCE ALARM (VSA) The CCL output channel can be alternatively confi gured for VSA usage. In CRR units the VSA is only monitored by the CRT s video input. When VSA mode is enabled and CRT s video input is missing (link otherwise operates normally, but e.g. only the camera is broken), the CCL OUT led blinks yellow and CCL output pins are closed. VSA have no effect to CRR s CCL input i.e. it can be used normally to transmit CCL information to CRT if VSA is not activated at CRT. In case when VSA is enabled at the same time in both CRT and CRR, then CCL channels are not available for other use. The VSA function can be set on/off by using a PC and any terminal type communication software (see separate documentation for CFO4 terminal software). The default factory setting is CCL usage (CC=CC). Picture 7. FC/PC Connectors Make sure the key is aligned in the slot properly before tightening! See table 6 for explanation of CCL connector s OUT led when VSA function is set active. Note! Video detection has 20 sec delay before VIDEO SOURCE ALARM is activated / inactivated. Led CCL OUT Color Green on/off blinking Yellow on/off blinking Status Video OK Video missing Table 6. CCL connector (RJ-45 female) / CCL OUT indicator led when VSA is enabled. FIBRE CONNECTION The optical connector is of the type FC/PC (see picture 7). The maximum optical input level is - dbm (nominal optical output level for return signal is - dbm). The link budget for both directions is 20 db. The operating wavelenght is 30 nm. When installing the fibre optic cable, do not exceed the minimum bending radius when connecting cable to the system. Note! For correct optical operation ensure that all optical connectors are cleaned immediately before mating. Connectors should always be cleaned using high purity alcohol (e.g. methyl or isopropyl alcohol). Dry the surfaces using clean compressed air or other equivalent pressurised gas. The optical connectors on the equipment should always be protected with dustcaps when there is no fi bre inserted. CFO4 Series User Manual rev00 7

Copyright Acknowledgements Information in this document is subject to change without notice and does not represent a commitment on the part of Teleste Corporation. Copyright 200-2002 Teleste Corporation. All Rights Reserved. No part of this document may be reproduced, transmitted, stored in a retrieval system, or translated into any other language without the express permission of Teleste Corporation. Teleste Corporation Video Networks P.O. Box 323 FIN-200 Turku FINLAND www.teleste.com/cctv 8 CFO4 Series User Manual rev00