MASTERELITE MULTITEC MRM/MRT MRM 10-20kVA single/single phase or three/single phase MRT 10-30kVA three/three phase

Similar documents
Sirius series. on-line

LIBRA pro. UPS kva three-phase / single-phase kva three-phase / three-phase. online

UPS Sentry MPS. SENTRY MPS is also compatible with different battery technologies: openvase lead acid and AGM and Gel VRLA, NiCd.

1PH RACK 19 SINGLE PHASE UPS Rev. 11 SR 6kVA 10kVA

UPS TRIFASE kVA Rev. 8 Serie TPH IGBT

Sentinel Dual High Power

Technical Data Sheets Uninterruptible Power Supply LP11 Series UPS kva

SmartOnline 10kVA On-Line, Double-Conversion UPS, 6U Rack/Tower, 3-Phase input, 1-Phase output

CPS kVA TRIFASE EN50171

THOR Modular. Modular UPS system. Online double-conversion Scalable Decentralized Parallel. Modular. 10, 20, 30, 40kVA modules kVA systems

SmartOnline V 10kVA 7kW Online, Double-Conversion UPS, 6U Rack/Tower, Extended Run, Pre-installed SNMP port, RS232, 3 Phase in-single Phase out

SUPREME PLUS series UPS UPS. on-line LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS

SR Plus series. on-line. SR20 Plus SR20T Plus. SR60 Plus LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS. Industrial PLCS

Intelligent On-Line UPS

UPS. centric Hot scalable modular 3-phase UPS Delivers 25 up to 200 kva/kw INFINITE POWER. Mission Critical Applications

on-line LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS internet centers (isp/asp/pop) industrial plcs industrial applications

UPS Emergency Bed Power Unit

ZP 120LCD. UPS 1,2,3,6,10,15,20 kva. Working in Power. online LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS

The quality management system is. Mitsubishi Electric Corporation Kobe Works has been approved to ISO9001:2000.

MasterNOVA. MasterNOVA (3/1) MasterNOVA 250i - 600i (3/3) MasterNOVA Pro /3)

ALL PSU Ltd ROTATION+ 6kVA - 10kVA PARALLEL ON LINE DOUBLE CONVERSION

LEVELUPS T3 3 UPS. SERIES kva ONLINE UPS 3:3 PHASE VFI TYPE. Highest Reliability with Embedded Isolation Transformer

SmartOnline SVTX Series 3-Phase 380/400/415V 30kVA 27kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

MasterNOVA. MasterNOVA (3/1) MasterNOVA 250i - 600i (3/3) MasterNOVA Pro /3)

LEVELUPS T3. SERIES kva ONLINE UPS 3:3 PHASE VFI TYPE. Highest Reliability and Robust Protection for Industrial Loads

Postfach 2327, Offenburg * Helmholtzstr. 13, Offenburg. Technical Data. Model protecto ER

GE Critical Power. Single Phase UPS Overview. 1 Gabriele Andrighetti

Symmetra LX APC Symmetra LX 8kVA Scalable to 16kVA N+1 Rack-mount, 208/240V Input, 208/240V and 120V Output

ZS 110. UPS 1, 2, 3, 6, 10kVA single/single phase. online LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS

Socomec Netys PR RT U P S TOWER / RACK MOUNT

ZP120N Online UPS. High Power Intensity. Flexibility. High efficiency with low heat dissipation. Smart Energy Solutions

GAMATRONIC, A SolarEdge Division.

Symmetra LX APC Symmetra LX 8kVA Scalable to 8kVA N+1 Rack-mount, 208/240V Input, 208/240V and 120V Output

Symmetra LX APC Symmetra LX 8kVA Scalable to 16kVA N+1, Tower 208/240V Input, 208/240V and 120V Output

TME Modular Series UPS System kva/kw - 208/220 VAC

Master MPS kva kva 3:1 3:3 VFI TYPE. System (ECS) HIGHLIGHTS. ONLINE EMERGENCY. SmartGrid ready. Flywheel compatible

SmartOnline 240/208/120V 8kVA 5.6kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, Split-Phase input, Bypass Switch

UPS EVO DSP TM ON LINE TM/TT. UPSman

Higher Availability: Self-diagnostics. Automatically tests unit electronics and batteries. Designed to simplify maintenance and troubleshooting.

SmartOnline V 12kVA 10.8kW Double-Conversion UPS, N+1, 8U, Extended Run, Network Card Slot, USB, DB9, Bypass, Hardwire

ZP 120 N. UPS 1,2,3,6,10,20 kva. online LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS

SmartOnline 208/120V or 240/120V 16kVA 11.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 8U Rack/Tower, USB, DB9 Serial

SmartOnline V 3kVA 2.7kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack, LCD display, USB, DB9 Serial

SmartOnline 208 & 120V 5kVA 4.5kW Double- Conversion UPS, 6U Rack/Tower, Extended Run, Network Card Slot, USB, DB9 Serial

SmartOnline SVX Series 120kVA Modular, Scalable 3-Phase, On-line Double-Conversion 400/230V 50/60Hz UPS System

APC Matrix-UPS 3kVA 208V/240V In 120/208/240V Out

Liebert GXT3 5kVA-10kVA UPS Compact UPS Systems For High Power Network Rack Applications. AC Power For Business-Critical Continuity

Tel: AC Power for Business-Critical Continuity TM

SmartOnline 208/230V 2.2kVA 1.98kW Double- Conversion UPS, 2U, Extended Run, Network Card Options, LCD, USB, DB9, ENERGY STAR

SmartOnline 240 & 120V 20kVA 18kW Double- Conversion UPS in 25U enclosure, Pre-installed Network Card, USB, DB9, Bypass, Hardwire

SmartOnline V 6kVA 5.4kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial, Bypass Switch

SmartOnline 40kVA Modular 3-Phase UPS System, On-line Double-Conversion UPS for North America

SATURN DATACENTER & SERVERS TELECOMMUNICATION DEVICE INDUSTRIAL APPLICATION TRANSPORTS. Smart Energy Solutions

SmartOnline V 3kVA 2.7kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 3U Rack, LCD display, USB, DB9 Serial

Critical Power 2017 Catalogue

SmartOnline SVX Series 90kVA 400/230V 50/60Hz Modular Scalable 3-Phase On-Line Double- Conversion Medium-Frame UPS System, 5 Battery Modules

Uninterruptible Power Supplies

Single phase UPS. Applications. Highlights. 1ph from 450 VA to 10 kva. Home Office Computers and peripherals Networks and servers Small data centers

SmartOnline 208/240 & 120V 20kVA 18kW, Double-Conversion UPS, N+1, 14U, Network Card Slot, USB, DB9, Bypass Switch

Sentinel Dual. 3,3-10 kva. High Power 1:1 3:1 VFI TYPE. selection High quality output voltage High battery reliability Emergency function HIGHLIGHTS

Liebert GXT4 UPS, 5kVA-10kVA Intelligent, Reliable UPS Protection

SmartOnline 120V 3kVA 2.7kW Double- Conversion UPS, 3U Rack/Tower, Extended Run, WEBCARDLX Network Interface, LCD, USB, DB9

SmartOnline 80kVA Modular 3-Phase UPS System, On-line Double-Conversion International UPS (not expandable to 120kVA)

AIS 3000 APC AIS kVA 400V w/3 Batt. Modules Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

Product Specifications

7011A Series Single-Phase

SmartOnline 20kVA On-Line Double-Conversion UPS, N+1, 14U Rack/Tower, 208/120V or 240/120V NEMA & C19 outlets

Product Snapshot. The Powerware Uninterruptible Power System. Product Focus

Smart-UPS XL APC Smart-UPS XL 2200VA RM 3U 120V

SmartOnline V 6kVA 5.4kW On-Line Double-Conversion UPS, Extended run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial, Hardwire

Smart-UPS RT APC SMART-UPS RT 2000VA 120V

10 kva 3/1 15 kva 3/1 20 kva 3/1 10 kva 3/3 15 kva 3/3 20 kva 3/3 30 kva 3/3 40 kva 3/3 UOUS SERV WARRANTY

MUST900 Modular UPS. Datacenter & servers. Internet centers. Local Area Networks (LAN) Telecommunication devices. Emergency application

ZP 120 N. UPS 1,2,3,6,10,20 kva. online LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS

PHASE ONE Series 700: Uninterruptible Power Supply (UPS) Systems

AP 160 N. UPS COMPACT Rack tower convertible 1-10 kva. online LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS

SmartOnline 40kVA Modular 3-Phase UPS System, On-line Double-Conversion UPS for North America

Powerstar PS3204rm2u True online 2KVA /1800W (19.7 deep)

SmartOnline 120V 2.2kVA 1.6kW Double- Conversion UPS, 2U Rack/Tower, Extended Run, Network Card Slot, USB, DB9 Serial

Model #: SU5000RT4UHV

SmartOnline 208/240 & 120V 8kVA 5.6kW Double- Conversion UPS, 4U Rack/Tower, Extended Run, Network Card Options, USB, DB9, Bypass Switch

Power Solutions Catalogue

Premium Online Series

SmartOnline 120V 3kVA 2.7kW Double- Conversion UPS, 2U Rack/Tower, Extended Run, Network Card Slot, LCD, USB, DB9 Serial

SmartOnline 208/230V 1kVA 900W Double- Conversion UPS, 2U, Extended Run, SNMP Card Option, LCD, USB, DB9, ENERGY STAR

PowerWAVE 9250DPA. ( N+1 kva/kw) Parallelable up to 1.5 MVA/MW

TECHNICAL SPECIFICATION SENTINEL DUAL

1. Introduction External description Front and Rear Panel The LCD screen Alarm Conditions...6

SmartOnline 120V 1kVA 900W Double- Conversion UPS, 2U, Extended Run, Network Card Options, LCD display, USB, DB9 Serial

SmartOnline V 1kVA 800W On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

The Power of Modularity

SmartPro 230V 1.5kVA 1.35kW Line-Interactive Sine Wave UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

SmartOnline V 3kVA 2.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

EP Series II UPS 230 V

Sentinel DUAL 6.5/10 kva THREE-PHASE/SINGLE-PHASE 3.3/10 kva SINGLE-PHASE/SINGLE-PHASE On Line Double Conversion Technology (VFI)

SmartOnline 277/480V 3-Phase Wye 80kVA Modular 3-Phase UPS System, On-line Double- Conversion UPS for North America

AP160N Online UPS compact

Model #: SU6000RT4UHVG

SmartOnline 120V 1.5kVA 1.35kW Double- Conversion UPS, 2U Rack/Tower, Extended Run, Oversize Internal Batteries, Network Card Slot, LCD, USB, DB9

Model #: SU5000RT4UTF

Transcription:

MASTERELITE MULTITEC MRM/MRT MRM 10-20kVA single/single phase or three/single phase MRT 10-30kVA three/three phase The MasterElite MultiTec range uses advanced digital online (VFI) technology to support loads up to 30kVA (120kVA for the maximum parallel system). MRM models provide a single phase output from a single or three phase input. MRT models provide a three phase output. The load is powered continuously by the inverter with an EMI filtered, stabilised and regulated sinewave supply. The MultiTec feature provides the UPS with three user selectable operating modes: On-line, Economy and Smart-Active to achieve high operating efficiencies up to 98%. In Economy mode the UPS mimics digital line interactive (VI) technologies used for less critical or sensitive loads. In Smart-Active mode the UPS monitors the stability of the mains supply and automatically selects whether to operate in on-line or line interactive mode. All modes can be set using the PowerShield 2 software supplied with each UPS. MasterElite is an outstanding long runtime solution for critical voice and data processing applications. Runtimes from several minutes to many hours can be achieved using battery extension packs (BEPs) with extra chargers to maintain reasonable recharge times, or local standby generators. 1 2 3 4 5 6 7 8 Language selection Input/Output measurements Controls/Settings/Customisation options Event log Alarm reset Time/Date Scroll down Scroll up Buttons 7 and 8 are used to display detailed operating information

FEATURES Advanced digital on-line (VFI) technology (EN50091-3) High reliability: microprocessor controlled static and manual bypass facility IGBT based power electronics Parallel and redundant (N+1) operation (up to 4 units) Dual input option High level diagnostics: states, modes, measurements and alarms Built-in front panel LCD with scroll function, RS232 and signal contact ports Power factor correction with sinusoidal input Low power consumption and maintenance costs (MTTR 30 minutes) Low cost and simplified installation including; castors for easy positioning, selection of the three phase or single phase input, and calibration of the output voltage from the front panel keypad to allow for voltage drop down long cable runs. High level surge immunity (6kV to IEC801-5) Auto restart on power up (programmable) Built-in battery test facility (automatic and manual), temperature compensating charger and deep battery discharge protection Cold-start facility to allow the UPS to power up without a mains supply for security applications such as emergency lighting APPLICATIONS Local Area Networks (LANs) Servers Data centres Internet centres (ISP/ASP/POP) Industrial PLCs PoS (Point of Sale) systems Emergency applications (lights/alarms) Medical appliances Telecommunications devices ADVANCED COMMUNICATION Advanced, multi-platform communication, for all operating systems and network environments: PowerShield 2 monitoring and control software included, with SNMP agent, for Windows 95, 98, 2000, Me, NT 4.0, Novell operating systems. The UPS is supplied with a cable for direct connection to a PC (Plug and Play) RS232 and modem serial ports IEC sockets for local plug in devices EPO (Emergency Power Off) contact for UPS shutdown using a remote panic button Remote control panel

single phase output models MRM MODEL 10KVA15KVA20KVA RECTIFIER INPUT Rated power [kva] 10 15 20 400Vac three-phase+n or 230Vac single-phase Voltage range ±20% Frequency range 45-65Hz Power factor 0.95 BATTERIES Type Maintenance free sealed lead-acid Recharge time 8h INVERTER OUTPUT Rated power [kva] 10 15 20 Active power [kw]* 8 12/10.5* 16/12* Number of phases 1 [V] 230 Voltage regulation range 200-243V Crest factor (Ipeak/Irms) 3:1 Waveform Sinewave Distortion with non-linear load 2% Static stability ±1% Dynamic stability ±5% in 10ms Frequency 50 or 60Hz selectable Overload 125/150% of the rated current for 10 /1 BYPASS 230V Number of phases 1 Permitted voltage range ±15% (selectable from ±5% to ±25%) Rated frequency 50/60Hz Permitted frequency range ±2% (selectable from ±1% to ±5%) INSTALLATION INFORMATION Input Three-phase or single-phase Remote signaling Volt-free contacts Remote controls EPO and bypass Communication RS232/C and modem ports Operating temperature 0-40 C Relative humidity 95% (non condensing) Colour Light grey RAL 7035 Audible noise <56dBA Enclosure protection rating IP20 Efficiency >92% Compliance Safety EN 50091-1 EMC EN 50091-2 Lev. A Directives 73/23-93/68-89/336 EEC Air flow (m3/h) (for installations in a closed environment) 320 320 480 Bypass input current 45A 68A 91A Maximum rectifier input current 18A 27A 36A Differential input current** 100mA VALUE OF THE OUTPUT PROTECTIONS FOR SELECTIVITY*** Normal fuses (GI) Normal switches (Curve C) Extra Fast fuses In (Rated current)/2 * With single-phase input ** This value must be added to the differential current of the equipment. Special applications on request *** Complying with these values, the UPS will be able to provide the power required to interrupt the output protection if a short-circuit occurs, without switching the load to the mains supply

Model No Power Back-up Dimensions Weight at full load (W x D x H) mm Kg MRM10KVA000 10kVA/8kW 0m 450 x 760 x 1200 105 MRM10KVA007 8m 450 x 760 x 1200 180 MRM10KVA009 11m 450 x 760 x 1200 190 MRM10KVA012 15m 450 x 760 x 1200 230 MRM15KVA000 15kVA/12kW 0m 450 x 760 x 1200 115 MRM15KVA007 8m 450 x 760 x 1200 230 MRM15KVA009 11m 450 x 760 x 1200 240 MRM15KVA012 15m 450 x 760 x 1200 310 MRM20KVA000 20kVA/16kW 0m 450 x 760 x 1200 120 MRM20KVA007 7m 450 x 760 x 1200 245 MRM20KVA012 10m 450 x 760 x 1200 315 TYPICAL BATTERY EXTENSION PACKS UPS Back-up Battery Extension Qty Dimensions Weight Model No at full load Packs (W x D x H) mm Kg MRM10KVA007 30m BEP384012Y/01 1 285 x 805 x 735 180 MRM10KVA012 40m BEP384012Y/01 1 285 x 805 x 735 180 MRM10KVA012 1h5 BEP384038AB/02* 1 555 x 720 x 1200 483 MRM15KVA007 28m BEP576012AB/01 1 555 x 720 x 1200 302 MRM15KVA012 40m BEP576012AB/01 1 555 x 720 x 1200 302 MRM15KVA000 1h5 BEP576038AC/02* 1 860 x 720 x 1200 720 MRM20KVA012 30m BEP576012AB/01 1 555 x 720 x 1200 302 MRM20KVA007 1h BEP576038AC/02* 1 860 x 720 x 1200 720 * Denotes that the battery pack has its own built-in charger OPTIONS USB signal converter SNMP network slot-in adapter Remote status panel with LEDs Wall mounted maintenance bypass with manual and automatic transfer Isolation (Galvanic) pack for the bypass supply Voltage conversion pack (110/230 and 230/110V) Battery cabinets, cladded racks, internal trays and cables Parallel/redundant operation card 19 rackmount trays and PowerRak cabinet system PowerShield 2 UPS monitoring and control software, and SNMP solutions Service and maintenance plans StrikeSafe Transient Voltage Surge Suppressors (TVSS)

three phase output models MRT MODEL 10KVA15KVA20KVA30KVA RECTIFIER INPUT Rated power [kva] 10 15 20 30 400Vac three-phase+n Voltage range ±20% Frequency range 45-65Hz Power factor 0.95 BATTERIES Type Maintenance free sealed lead-acid Recharge time 8h INVERTER OUTPUT Rated power [kva] 10 15 20 30 Active power [kw] 8 12 16 24 Number of phases 3 [V] 400 Voltage regulation Adjustable from 346-42 V Crest factor (Ipeak/Irms) 3:1 Waveform Sinewave Distortion with non-linear load 2% Static stability ±1% Dynamic stability ±5% in 10ms Frequency 50 or 60Hz selectable Overload 125/150% of the rated current for 10 /1 BYPASS 400V Number of phases 3 Permitted voltage range ±15% (selectable from ±5% to ±25%) Rated frequency 50/60Hz Permitted frequency range ±2% (selectable from ±1% to ±5%) INSTALLATION INFORMATION Input Three-phase+N Remote signaling Volt-free contacts Remote controls EPO and bypass Communication RS232/C and modem ports Operating temperature 0-40 C Relative humidity 95% (non condensing) Colour Light grey RAL 7035 Noise <56dBA Enclosure protection rating IP20 Efficiency >92% Compliance Safety EN 50091-1 EMC EN 50091-2 Lev. A Directives 73/23-93/68-89/336 EEC Air flow (m3/h) (for installations in a closed environment) 320 320 480 480 Bypass input current 15A 23A 30A 46A Maximum rectifier input current 18A 27A 36A 54A Differential input current* 100mA VALUE OF THE OUTPUT PROTECTIONS FOR SELECTIVITY** Normal fuses (GI) Normal switches (Curve C) Extra Fast fuses (EF) In (Rated current)/2 * This value must be added to the differential current of the equipment. Special applications on request ** Complying with these values, the UPS will be able to provide the power required to interrupt the output protection if a short-circuit occurs, without switching the load to the mains supply

Model No Power Back-up Dimensions Weight at full load (W x D x H) mm Kg MRT10KVA000 10kVA/8kW 0m 450 x 760 x 1200 110 MRT10KVA007 8m 450 x 760 x 1200 185 MRT10KVA009 11m 450 x 760 x 1200 195 MRT10KVA012 15m 450 x 760 x 1200 235 MRT15KVA000 15kVA/12kW 0m 450 x 760 x 1200 120 MRT15KVA007 8m 450 x 760 x 1200 235 MRT15KVA009 11m 450 x 760 x 1200 245 MRT15KVA012 15m 450 x 760 x 1200 315 MRT20KVA000 20kVA/16kW 0m 450 x 760 x 1200 125 MRT20KVA007 7m 450 x 760 x 1200 250 MRT20KVA012 9m 450 x 760 x 1200 320 MRT30KVA000 30kVA/24kW 0m 450 x 760 x 1200 135 MRT30KVA014 6m 450 x 760 x 1200 260 TYPICAL BATTERY EXTENSION PACKS UPS Back-up Battery Extension Qty Dimensions Weight Model No at full load Packs (W x D x H) mm Kg MRT10KVA007 30m BEP384012Y/01 1 285 x 805 x 735 180 MRT10KVA012 40m BEP384012Y/01 1 285 x 805 x 735 180 MRT10KVA012 1h5 BEP384038AB/02* 1 555 x 720 x 1200 483 MRT15KVA007 28m BEP576012AB/01 1 555 x 720 x 1200 302 MRT15KVA012 40m BEP576012AB/01 1 555 x 720 x 1200 302 MRT15KVA000 1h5 BEP576038AC/02* 1 860 x 720 x 1200 720 MRT20KVA012 30m BEP576012AB/01 1 555 x 720 x 1200 302 MRT20KVA007 1h BEP576038AC/02* 1 860 x 720 x 1200 720 * Denotes that the battery pack has its own built-in charger OPTIONS USB signal converter SNMP network slot-in adapter Remote status panel with LEDs Wall mounted maintenance bypass with manual and automatic transfer Isolation (Galvanic) pack for the bypass supply Voltage conversion pack (110/230 and 230/110V) Battery cabinets, cladded racks, internal trays and cables Parallel/redundant operation cards 19 rackmount trays and PowerRak cabinet system PowerShield 2 UPS monitoring and control software and SNMP solutions Service and maintenance plans StrikeSafe Transient Voltage Surge Suppressors (TVSS) Advance Galatrek. Advance Park, Wrexham. LL14 3YR United Kingdom Sales: 0800 269 394 Service: 01978 821 086 Web: www.aelgroup.co.uk Registered in England & Wales No. 1742090. An AEL Group Company