DATA SHEET Selectable AC transducer, TAS-321 DG

Similar documents
DATA SHEET Selectable AC transducer, TAS-331DG

DEIF A/S. TAS-331DG Selectable AC transducer G (UK) Installation and start up instructions. Watt or var transducer

EM2020 Selectable AC transducer A (UK)

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET

Engine Control Unit, ECU 100 Engine control Engine monitoring and protection Easy-to-read graphical display Integrated emulation software solution

Engine Control Unit, ECU 100 Engine control Engine monitoring and protection Easy-to-read graphical display Integrated emulation software solution

DATA SHEET IOM 200 analogue interface for AGC 200

MIC-2 Multi-instrument DATA SHEET

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S

Compact Genset Controller, CGC 400 Generator control and protection Engine monitoring and protection Generator and mains breaker control RS485 Modbus

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

Basic Gen-set Controller multi-line F SW version 2.31.X or later

SPARE PART ONLY. Basic Gen-set Controller Multi-line H SW version 2.31.X or later. Data sheet. Standard functions

DATA SHEET. Advanced Energy Meter, AEM 380 & AEM 305

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

Generator Protection Unit, GPU Hydro Multi-line A SW version 2.4X.X

DATA SHEET. Advanced Power Meter, APM 380 & APM 305

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

Panorama rudder indicator TRI-2 Analogue or CAN input Approved according to MED Three extra large scales Long-life LED illumination Built-in dimmer

Generator Protection Unit, GPU-3 Generator protection (ANSI) Busbar protection (ANSI) M-Logic (Micro PLC) Display General

MIC-2 MKII, Multi-instrument DATA SHEET

Generator Paralleling Controller, GPC-3 Gas Regulation modes Generator protection (ANSI) M-Logic (Micro PLC) Busbar protection (ANSI) Display General

Generator Protection Unit, GPU-3 Gas Generator protection (ANSI) Busbar protection (ANSI) M-Logic (Micro PLC) Display General

DATA SHEET Rudder/azimuth angle Transmitter CAN, RTC 300/RTC 600

02/11/2015

DATA SHEET. AGC PM Automatic Genset Controller, Plant Management

Generator Paralleling Controller, GPC-3 Regulation modes Generator protection (ANSI) M-Logic (Micro PLC) Busbar protection (ANSI) Display General

DEIF A/S. Generator Paralleling Controller multi-line L. Type GPC / GS. Compact system in one unit

Multifunction Transducer MT440

DATA SHEET Compact Genset Controller, CGC 200

Displays Transducers. Displays and transducers

Basic Gen-set Controller G (UK) SW version 2.1X.X. Terminal strip overview

DATA SHEET Paralleling and Protection Unit, PPU-3

NOT RECOMMENDED FOR NEW DESIGNS

Plug-in module SIRAX TV 808, 2 channels Isolating Amplifier unipolar/bipolar

MID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

Engines & Gen-sets N, page 1 of 6

Automatic Gen-set Controller Multi-line D

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

Delomatic 4, DM-4 Land DATA SHEET

RTC 300/RTC 600 Installation instructions scan

Data sheet ACT20P ACT20P-CMT-10-AO-RC-S. Phone: Fax: Web: - [!

EMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks

Zelio Control-modular measurement and control relays 1

Power supply. Interface technology in modular housing DIN rail devices, IM series. Features

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

Installation / Control Technique

TRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.:

SUBJECT TO CHANGE WITHOUT NOTICE

DS5000-IBFS. 5kA rms - 8kA DC Fluxgate current transducer. Features. Description. Application. Precision Innovation /

Advanced Genset Controller, AGC 200 Operation modes Display and unit front General Engine control M-Logic Optional applications

DATA SHEET LAN Server For Energy and Power meters AEM and APM with Modbus interface

MINI MCR-SL-PT100-UI-200

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description

E-STOP relays, safety gate monitors

DATA SHEET DEPRECATED - PCM5 1. Document no.: N/A

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA

MULTI-LINE 2 APPLICATION NOTES. Converting PPU-2 to PPU-3 Parameter conversion Wiring Options I/O list. Document no.: A SW version:

SUBJECT TO CHANGE WITHOUT NOTICE

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

Voltage Transducer UMT516 / MT516

Generator Controller GC-1F

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

DATA SHEET Automatic Genset Controller, AGC-3

USER MANUAL 2012 V1.1

RM35TF V AC

ISOMETER isopv with coupling device AGH-PV

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA 250 V AC

LED Driver Linear / area fixed output

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact

SAFE, FLEXIBLE, EASY CURRENT TRANSFORMER CURRENT TRANSFORMERS FOR THE SAFE MEASUREMENT OF HIGH CURRENTS

Your process requires the utmost attention Our new ACT20C signal conditioners support you in achieving this

DATA SHEET Applicable for offshore or nearshore

E-STOP relays, safety gate monitors

Data Sheet. Digital Multifunctional Power Meter with LCD Display and Optional Modules WPM D

PHOENIX CONTACT Features

DATA SHEET Advanced Graphical Interface, AGI 100 series

THE NEXT TRANSDUCER GENERATION

Advanced Genset Controller, AGC 200 Operation modes Display and unit front General Engine control M-Logic Optional applications

MINI MCR-SL-UI-2I-NC. Extract from the online catalog. Order No.:

LED Driver Linear / area fixed output

Micro Contactor MA Series

E-STOP relays, safety gate monitors

QUINT-PS/ 1AC/24DC/ 5

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.

Generator Protection Unit, GPU-3 DATA SHEET

QUINT-PS AC/24DC/10

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

Energy Management Energy Transducer Type ET112

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA

DATA SHEET Genset Controller, GC-1F

Delomatic 4, DM-4 Marine & Offshore DATA SHEET

VEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA

METERING INSTRUMENTS AND CURRENT TRANSFORMERS

RM35TF. Main. Product or component type. Product specific application. Relay monitored parameters 250 V AC 5 A AC

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

ASI QUINT /2.4 EFD

RCMB20/RCMB Series

Transcription:

DATA SHEET Selectable AC transducer, TAS-321 DG Bi-directional current measurement on AC networks Power measurement using 2 phases on 3-phase networks Class 0.5 (IEC688) measurement Easy configuration via PC interface Non-linear output characteristics DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: +45 9614 9615 info@deif.com www.deif.com Document no.: 4921220040H SW version:

1. 1.1. Contents...3 1.1.1. Application...3 1.1.2. Example of single slope...3 1.1.3. Connection diagram...4 1.1.4. General technical specifications...5 1.1.5. Specific technical specifications...6 1.1.6. Available variants...7 1.1.7. Available accessories...7 1.1.8. Order specifications (examples)...8 1.1.9. Accessories...8 1.1.10. Dimensions in mm (inches)...9 1.1.11. Mounting instructions...9 1.1.12. Disclaimer...9 DEIF A/S Page 2 of 9

1. 1.1 Contents 1.1.1 Application TAS-321DG is a micro-controller based AC transducer with 1 analogue output for measurement of bi-directional current. The sign for current direction is based on the measured power direction. Furthermore, the transducer can be used for measurement of active power or reactive power on a 3-phase network where only 2 phases are available for the measurement. TAS-321DG can be delivered pre-configured or it can be delivered un-configured for customer configuration through the PC interface. TAS-321DG can be configured as a normal linear transducer or with up to three slopes giving the possibility for a higher resolution in one or two ranges of the measurement. Upper and lower output limitations can also be configured. 1.1.2 Example of single slope For further examples, see data sheets for TAS-311DG/TAS-331DG Output Voltage Upper limit End value 12V 10V -200A Input Current (AC) 200A -10V -12V Start value Untere Grenze DEIF A/S Page 3 of 9

1.1.3 Connection diagram CURRENT POWER AUX SUPPLY + ~ ~ - OUTPUT AUX SUPPLY + ~ ~ - OUTPUT AUX SUPPLY + ~ ~ - OUTPUT 1 3 10 11 X1 X2 1 3 10 11 X1 X2 1 3 10 11 X1 X2 TAS-321DG TAS-321DG TAS-321DG N L1 L2 16 17 19 23 IL1 24 N L1 L2 16 17 19 23 IL1 24 N L1 L2 16 17 19 23 IL1 24 L1 L2 S1 P1 S2 P2 L1 L2 S1 P1 S2 P2 L1 S1 P1 S2 P2 L2 L3 L3 N 1W 1W2 I L3 1W2] / 1var2 [ Coupling 17 19 23/24 1W2 I/1var2 I L1 L2 L1 1W2 II/1var2 II L2 L3 L1 1W2 III/1var2 III L3 L1 L1 With voltages above 480 V phase-phase! The secondary side of the current transformer MUST be connected to earth. Alternatively, a double insulated current transformer can be used. DEIF A/S Page 4 of 9

1.1.4 General technical specifications Accuracy Current/power: Class 0.5 (-10 15 30 55 C) according to IEC 688 Influence, phase angle Meas. current (I n ) Overload, currents Load Meas. voltage (U n ) Overload, voltages Load Frequency range Indication Output Standard range Limit Output load Output cable out/ Rload Ambient temperature ±0.75 0.75/1.5/3.0/6.0 A Meas. range (In): 0 200 % 20 A max., continuously 75 A max. for 10 s 240 A max. for 1 s Max. 0.5 VA 73/140/254/400 V phase to neutral Meas. range (U n ): 30 120 % (57...400 V) 127/240/440/690 phase to phase Meas. range (U n ): 30 120 % (100...600 V) 1.2 x U n max., continuously 2 x U n max. for 10 s Min. 480 kω 30 45 65 80 Hz Note: For fundamental frequency (1. harmonic) outside 20 Hz...80 Hz, the input is fixed at 0 Red LED function: (The LED is located behind the front plate) Calibration error = flash frequency 5 Hz Configuration error = flash frequency 1 Hz 1 analogue output Output (0...100 %): 0...1 ma, 0 5 ma, 0...10 ma, 0...20 ma, 0...1 V, 0...5 V, 0...10 V Output (10...100 %): 0.1...1 ma, 0.5...5 ma, 1...10 ma, 2...20 ma, 0.1...1 V, 0.5...5 V, 1...10 V Output (20...100 %): 0.2...1 ma, 1...5 ma, 2...10 ma, 4...20 ma, 0.2...1 V, 1...5 V, 2...10 V Output (-100...0...100 %): -1...0...1 ma, -5...0...5 ma, -10...0...10 ma, -20...0...20 ma, -1...0..1 V, -5...0...5 V, -10...0...10 V Other ranges possible Max. ±120 % of nominal output Burden if current output: Max. 10 V (max. 1 kω) Burden if voltage output: Max. 20 ma Max. length 30 m 10 V, 5 V, 1 V, 20 ma ranges according to IEC 688 10 ma, 5 ma, 1 ma ranges ±0.5% -10 55 C (nominal) -25 70 C (operating) -40 70 C (storage) DEIF A/S Page 5 of 9

Temperature coefficient Response time Max. ±0.2 % of full scale per 10 C <150 ms, typically 125 ms Ripple Twice the class index (peak to peak measurement) according to IEC 688 Galvanic separation AC aux. models: Between inputs, outputs and aux. : 3750 V-50 Hz-1 min. DC aux. models: Between inputs and outputs: 3750 V-50 Hz-1 min. Between inputs and : 3750 V-50 Hz-1 min. Between and outputs: 1500 V-50 Hz-1 min. 57.7-63.5-100-110-127-200-220-230-240-380-400-415-440-450-480-660-690 V AC ±20 % 24-48-110-220 V DC -25/+30 % (Aux. ) 3.5 VA/2 W Climate HSE, to DIN 40040 EMC According to EN 61000-6-1/2/3/4 Protection Housing: IP40. Terminals: IP20 to IEC 529 and EN 60529 Aux. voltage Consumption Connections Materials Max. 2.5 mm² multi-stranded Max. 4.0 mm² single-stranded All plastic parts are self-extinguishing to UL94 (V1) 1.1.5 Specific technical specifications Current Measuring current 0.5...8 A Start value End value -100...+67 % of end value 100 % of measuring current Current/power Connection 1W note only current: (IL1 and UL1-N) or (IL2 and UL2-N) or (IL3 and UL3-N): 57...400 V AC 1W2 I: (IL1 and UL1-L2): 100 690 V AC 1W2 II: (IL1 and UL2-L3): 100 690 V AC 1W2 III: (IL1 and UL3-L1): 100 690 V AC DEIF A/S Page 6 of 9

1.1.6 Available variants Type TAS-321DG, bi-dir. current TAS-321DG, bi-dir. current TAS-321DG, power 1W2 TAS-321DG, power 1W2 TAS-321DG, power 1VAr2 TAS-321DG, power 1VAr2 Variant no. Description Item no. Note 01 TAS-321DG, customised - AC voltage aux. 02 TAS-321DG, customised - DC voltage aux. 03 TAS-321DG, customised - AC voltage aux. 04 TAS-321DG, customised - DC voltage aux. 05 TAS-321DG, customised - AC voltage aux. 06 TAS-321DG, customised - DC voltage aux. TAS-321DG 07 TAS-321DG, unconfigured - AC voltage aux. TAS-321DG 08 TAS-321DG, unconfigured - DC voltage aux. 2962010000-01 2962010000-02 2962010000-03 2962010000-04 2962010000-05 2962010000-06 2962010000-07 2962010000-08 1.1.7 Available accessories Type Description Item no. Note Accessories for TAS TAS configuration kit 2032410021 Accessories for TAS 30 extra labels 2192410001 DEIF A/S Page 7 of 9

1.1.8 Order specifications (examples) The examples below are order specifications for pre-configured transducers. For un-configured transducers, only auxiliary voltage must be specified. TAS-321DG Item no. 2962010000-02 2962010000-03 Type Bi-directional current Power Variant no. 02 03 Measuring range -120 0 120 A AC 0 20 MW Coupling 1 W 1W2 II VT ratio - 10 kv/100 V Input voltage 400 V AC 100 V AC CT ratio 100/1 A 100/5 Input current -1.2 0 1.2 A NA Transfer curve Single slope Single slope Output start value -10 V 4 ma Threshold 1 - - Mid value 0 12 ma Threshold 2 - - Output end value 10 V 20 ma Output lower limit -12 V 4 ma Output upper limit 12 V 21.5 ma Auxiliary voltage 110 V DC 400 V DC 1.1.9 Accessories Please order separately: PC configuration kit containing connection cable and software for customer configuration Extra labels DEIF A/S Page 8 of 9

1.1.10 Dimensions in mm (inches) 99.7 (3.93) 85.0 (3.35) 4.5 (0.18) 75.0 (2.95) 61.0 (2.40) 110.0 (4.33) 1.1.11 Mounting instructions The transducer is designed for panel mounting, being mounted in a 35 mm DIN rail, or by means of two 4 mm screws. The design of the transducer makes mounting of it close to similar equipment possible, however make sure that there is min. 50 mm between the top and bottom of the transducer and other equipment. The DIN rail must always be placed horizontally when several transducers are mounted on the same rail. 1.1.12 Disclaimer DEIF A/S reserves the right to change any of the contents of this document without prior notice. The English version of this document always contains the most recent and up-to-date information about the product. DEIF does not take responsibility for the accuracy of translations, and translations might not be updated at the same time as the English document. If there is a discrepancy, the English version prevails. DEIF A/S Page 9 of 9