Operation Manual for USB Autoscope Lite. Contents. USB Autoscope Lite Operation Manual

Similar documents
mscope Low Cost, High Performance Automotive Scope

SUPERSCAN II. Always a step ahead.

RT USB3000 Technical Description and User Manual. Revision 4.1.

DRTS 64. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters.

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Precise results in record time.

MEphisto Scope 1 A D. Prozessor-Steuerung. Interner Daten-/Steuer-Bus. Digital I/O-Teil

DRTS 66. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

CompuScope Ultra-fast waveform digitizer card for PCI bus. APPLICATIONS. We offer the widest range of

DRTS 33. The new generation of advanced three phase relay test set

Electronic SUNSTAR & 传感与控制 Software TEL: FAX: KiBox To Go Measurement and Ev

True RMS AC Voltage/Current Datalogger

DAQ-System for DynoWare

About the Presentations

B. VGA Webcam with Communication Headset USER MANUAL

SCIENCEWORKSHOP 750 INTERFACE. Instruction Sheet for the PASCO Model CI Introduction

DRTS 66 can test all the following relays

A variety of ECONseries modules provide economical yet flexible solutions. Waveform Generation

Handyscope HS3. User manual. TiePie engineering

CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL

THE NEW GENERATION OF ADVANCED TEST EQUIPMENTS FOR RELAYS, ENERGY METERS, TRANSDUCERS AND POWER QUALITY METERS.

Keysight U2751A USB Modular Switch Matrix

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

User Guide for Digidata 1440A

User s Guide Tenma USB PC Based Digital Oscilloscope Operation Manual

CAUTION: CAREFULLY READ INSTRUCTIONS BEFORE PROCEEDING. NOT LEGAL FOR SALE OR USE IN CALIFORNIA OR ON ANY POLLUTION CONTROLLED VEHICLES.

Lecture 23. Finish-up buses Storage

3-Axis G-Force Datalogger

PARAMETER MIN TYP MAX UNITS COMMENTS

RIPMR Regional Institute for Physical Medicine and Rehabilitation Kallettumkara, Irinjalakuda

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter

Temperature measurement board, optically isolated, 16/8/4 channels for thermocouples, Pt100, RTD, 18-bit

User s Guide DSO-5200 USB PC Based Digital Oscilloscope Operation Manual

DRTS 3 PLUS Advanced Protection Relay Test Set and Measurement System

PROFESSIONAL. Users Guide. Version 3.5

Installation Guide & Users Manual

DT9800 Series. USB Function Module for Data Acquisition

Three-Phase Power Quality Analyzer PowerPad Model 3945-B

TM258LD42DT4L compact base M I/O - 24 V DC

A+ Guide to Hardware: Managing, Maintaining, and Troubleshooting, 5e. Chapter 1 Introducing Hardware

User s Guide. LA5034 Operation Manual

Introducing the esata II-150 PCI

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

STC-TGL1 User s Manual. Toll Free Customer Support Version /07

RETUFU H O MAIN 2008 GM Service and Parts Operations

OX 5022-CK OX 5042-CK

PG1000. USB Proximity Desktop Reader and Programmer User Guide

WALKING TEST KIT WT5000

power quality Models 8230 & 8220

Multi-Function Ground Resistance Tester Model 6471

USB COMMUNICATIONS INTERFACE LOOP LINK Contents. Side 1. Page 15. Page 29. Seite 43

Powertrain Control Unit TAG-320

Programmable temperature transducer from Pt1000 sensor to current loop 4-20 ma Instruction Manual

Model No user manual

INSTALLATION INSTRUCTIONS

SCP for Plastics Processing

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

Cyber 2S1P 950 PCI Quick Installation Guide

V

Autoranging True RMS Multimeter User Manual

HygroClip DI Digital Interface for HygroClip Probes v 1.0 Instruction Manual

DriveWizard Plus Instruction Manual

DRTS 3 PLUS. Advanced Protection Relay Test Set and Measurement System. DRTS 3 PLUS has been designed to test:

Product Information on the Manual

Reference. Menu Overview. Functions Common to Generator (TX) and Analyzer (RX) AC Power. Selecting 115 VAC or 230 VAC Operation

RoHS. Shock / vibration resistant. Short circuit proof. Flexible. . XXXX e. . XXXX e

GFK-2415A March Type of sensor connection

WP100 Platform. control systems. CPU module for small and medium sized wind turbines. Safe operation in harsh environments

EXOcompact Third Generation Manual

KiBox To Go. Electronics & Software. Measurement and Evaluation System for Combustion Analysis on Test Benches and in Vehicles

Quick Setup & Getting Started

Cyber 2S1P 950 PCI Quick Installation Guide

Model A Mini AC/DC Clamp Meter. User's Guide

After unpacking, confirm that there are no problems (scratches and dirt) on the exterior before use.

Standalone combined PIR camera with RF transmitter

RAPIDOSE ACCU-DYN+ USER GUIDE. Dynalyzer Accu-Dyn+ Display System OPERATION MANUAL. Rapid Measurements with a super small footprint detector

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

TM258LF42DT compact base M I/O - 24 V DC - CANopen

Part 1 of 3 -Understand the hardware components of computer systems

PowerPad QUICK START 8335 USER GUIDE IMPORTANT WARRANTY NOTE:

5000V Digital/Analog Megohmmeter Model 5060

Agilent U2751A USB Modular Switch Matrix. Data Sheet

User's Manual. Autoranging Datalogging Insulation Tester (Megohmmeter) with PC Interface. Model

Part Numbers SNAP-IT-EMU1

Service Technical Resources MUT-III. (Multi-Use Tester-III*) Quick Reference Guide

TM241CE24U controller M IO transistor NPN Ethernet

PG1000. Multi-Tech Reader and Programmer User Guide

USB 2.0 to DVI Adapter Quick Installation Guide

TM241CE40R controller M IO relay Ethernet

Serial Communication Converters & Adapters Instruction Manual

WS600/H1 BASIC SYSTEM

Programming SureStart

500 Series Installation Guide

FireWire Hi-Speed USB Combo Quick Installation Guide

VALCON EasyWriter Ver1.0E Manual

MicroBench MB-500A. Live Logic Logic source pattern generator Logic analyzer Arbitrary waveform generator Protocol interactive test

GS-PCLA Channel PC Logic Analyzer Instruction Manual

EMTRON AUSTRALIA EMTRON ECU OVERVIEW

TM221CE40R controller M IO relay Ethernet

Level transmitter TR3420 Instructions manual

Transcription:

Operation Manual for USB Autoscope Lite Please read this manual thoroughly before attempting to operate the device. Contents 1. Purpose...2 2. Technical characteristics of the USB Autoscope Lite...2 2.1 General...2 2.2 Analog oscilloscope mode...3 2.3 Software...3 2.4 Parameters of the USB port's galvanic isolation...4 2.5 Front panel elements...5 2.6 Back panel elements...5 2.7 Ground cord...6 3. Preparing the computer for use with the USB Autoscope Lite...7 3.1 Minimum Laptop or PC requirements...7 3.2 Installation of the USB Oscilloscope program and utilities...8 3.3 Installation of the device drivers...12 4. Preparing the device for use...13 5. Manufacturer limited warranty...14 6. Troubleshooting...14 6.1 The device does not turn on...14 6.2 "USB transfer error"...14 http://usbautoscope.eu/ 1

1. Purpose The USB Autoscope Lite is used for troubleshooting of various electronic vehicle systems, such as ignition and timing system. The USB Autoscope Lite is also very useful for engine mechanical diagnostics. The device is universal in nature and not tied to any particular vehicle system or brand. The device works in conjunction with the USB Oscilloscope program and connects to any USB 2.0 12 Mbit/s (Full-SPEED) port of a Windows laptop or PC. The Windows version should be XP SP2 or higher. 2. Technical characteristics of the USB Autoscope Lite 2.1 General PC interface type USB 2.0 12 Mbit/s (Full-SPEED) Device supply source from USB Current consumption from USB no more than 120 ma Device provides uninterrupted (frameless) data transfer of digitized data to the laptop or PC The stream of digitized data is stored directly on the hard disk of the laptop or PC in real time http://usbautoscope.eu/ 2

2.2 Analog oscilloscope mode Number of analog channels 8 Number of universal analog inputs 6 Number of inputs for high-voltage transducers Number of inputs for the synchronization transducer Voltage range 2 1 analog inputs 1 4 ±15 V analog inputs 5, 6 ±150 V Input impedance 1 MΩ ADC resolution 12 14 bit 1 Maximum sampling frequency for channel: 2.3 Software in 1 channel sub mode 250 khz in 2 channel sub mode 125 khz in 4 channel sub mode 50 khz in 8 channel sub mode 25 khz Supported operating systems Windows XP SP2 / SP3, Windows Vista, Windows 7, Windows 8 / Windows 8.1 / Windows 10 Main features Displaying mode + recording + measuring in real time simultaneously. Number of channels Selectable 1, 2, 4, 8 Scale parameters: 1 channel sub mode 0.1 ms / Div 1 S / Div. with step 1-2-5 2 channel sub mode 0.2 ms / Div 1 S / Div. with step 1-2-5 4 channel sub mode 0.5 ms / Div 1 S / Div. with step 1-2-5 8 channel sub mode 1 ms / Div 1 S / Div. with step 1-2-5 1 The nominal signal digitizing depth is 12 bit, increasing up to 14 bit with slower digitizing speeds. http://usbautoscope.eu/ 3

Voltage sensitivity setting 2 : for input voltage range ± 15 V 5 mv / Div 10 V / Div. with step 1-2-5 for input voltage range ± 150 V 50 mv / Div 100 V / Div. with step 1-2-5 when using high voltage probes 50 V / Div 100 kv / Div. with step 1-2-5 Trigger modes: auto normal wait single none Trigger parameters: channel front level Maximum file size depends on the file system: FAT32 4 GB level increasing threshold threshold time minimal interval NTFS 16 TB 2.4 Parameters of the USB port's galvanic isolation USB Autoscope Lite has galvanic isolation of the USB port (device inputs ground <> PC ground) Galvanic isolation resistance not less than 10 GΩ Galvanic isolation capacitance not more than 70 pf Galvanic isolation test voltage 1 kv for 1 minute 2 The value of the maximum voltage sensitivity depends on the sampling frequency. http://usbautoscope.eu/ 4

2.5 Front panel elements Front panel of the USB Autoscope Lite. 1 4 Connections for analog inputs 1 4. Input voltage range ± 15 V. 5 6 Connections for analog inputs 5 6. Input voltage range ± 150 V. 7 USB status indicator. 2.6 Back panel elements Back panel of the USB Autoscope Lite. 1, 3 Connections "In+" and "In " are used for connection of high voltage probes. The signals from the high voltage probes are inversely summed and go to the analog input 8. 2 Connection "In Synchro" is used for the synchronization (trigger) transducer that is used to detect ignition spark. The signal from the transducer goes to the analog input 7 through a peak detector. 4 Device ground connection. Used to connect device ground to vehicle ground on the diagnosed vehicle. 5, 6 Pulse polarity indicator from synchronization transducer. 7 USB connection. Used for connection of the USB Autoscope Lite to USB 2.0 12 Mbit/s (Full-SPEED) port of a laptop or PC. The connection uses a USB 2.0 type A-B cable. http://usbautoscope.eu/ 5

2.7 Ground cord Signal measurements on the analog inputs of the USB Autoscope Lite are recommended to perform relatively to the black alligator clip of the ground cord. Therefore, before starting the measurement, the cable must be connected to the back of the device connector (ground) and the black alligator clip must be connected to vehicle ground on the diagnosed vehicle. When working with high-voltage probes, this connection is necessary. In case of breakage of the cable, it can be repaired or manufactured according to the diagram below. 2 Signal ground. Ground cord of the USB Autoscope Lite. 4 Common ground of the high-voltage transducers. http://usbautoscope.eu/ 6

3. Preparing the computer for use with the USB Autoscope Lite 3.1 Minimum Laptop or PC requirements Processor Pentium II 500 MHz RAM (random-access memory) 512 MB Hard disk drive 10 GB of free disk space, data-transfer protocol at least UDMA 66 Optical disc drive CD-ROM for software installation PC interface port USB 2.0 12 Mbit/s (Full-SPEED) Video adapter AGP or PCI Express Monitor SVGA Operating system Windows XP SP2 / SP3, Windows Vista, Windows 7 or Windows 8 / Windows 8.1 / Windows 10 Additional requirements Any reasonably modern laptop or PC will be adequate http://usbautoscope.eu/ 7

3.2 Installation of the USB Oscilloscope program and utilities Insert the installation CD disc in the optical disk drive of the computer. If the notification "Tap to choose what happens with this disk" appears, left-click the message screen. Choose the option "Run setup.exe". If after inserting installation CD in the optical disk drive of computer nothing happens, browse through the disc and open the program setup file, called "Setup.exe". The drive letter your computer uses for the optical drive, often D:\Setup.exe or E:\Setup.exe http://usbautoscope.eu/ 8

If a pop up about unknown publisher of "setup.exe" appears, click "Yes". You may have to wait while the installer verifies. In the window "Installer Language", change the installation language if desired. Then, follow the installation instructions, changing parameters only when required. http://usbautoscope.eu/ 9

In window "Windows Security" activate option "Always trust software from " then press button "Install". If the message "Windows can't verify the publisher of this driver software" appears, choose the option "Install this driver software anyway". If a message about the need to install "Adobe Reader" or "Adobe Flash Player ActiveX" software appears, agree and install the suggested program. Installation of the additional software may take several minutes. http://usbautoscope.eu/ 10

Press the "Finish" button. Now the USB Oscilloscope software is installed completely and drivers are presetting. http://usbautoscope.eu/ 11

3.3 Installation of the device drivers Connect the device to USB 2.0 12 Mbit/s (Full-SPEED) port of the laptop or PC only after installation of USB Oscilloscope software. Right after connection of the device to a USB 2.0 12 Mbit/s (Full-SPEED) port the installation of drivers will start automatically. After successful installation the user will get an installation report. http://usbautoscope.eu/ 12

4. Preparing the device for use The device connects to a laptop or PC's USB port using a USB 2.0 A/B interface cable. The computer must have Microsoft Windows XP SP2 or higher operating system and have the USB Oscilloscope software installed. Before the measurements, the black alligator clip from the USB Autoscope Lite's ground cord must be connected to vehicle ground on the diagnosed vehicle. The preferred connection point is a vehicle body ground on the diagnosed vehicle. If an older vehicle, use the engine ground. The signal measurements on the analog inputs are relative to vehicle ground, because the vehicle ground is connected to the common ground of the device through the black alligator clip of the ground cord. Note that in some cases signal ground and ground of vehicle body are not at the same potential. One example would be Lambda or Oxygen sensor ground on GM vehicles. This can skew voltage readings if not taken in to account. In such cases a differential mode can be used, connect one channel to the signal and another channel to the signal ground. The device and it's cables must be placed as far as possible from the high voltage wires of the ignition system, the exhaust manifold, and the cooling system fan. The computer itself must be grounded using a separate multi stranded copper wire with a cross section of more than 0.5 mm 2, otherwise a failure of the computer or device is possible. If a laptop running on its internal battery and with the main power supply disconnected is used, this requirement is unnecessary. In order to avoid distortion and / or damage to the data that are sent via the USB interface, due to electromagnetic interference from the vehicle's ignition system, it is recommended to ground the USB Autoscope Lite using a separate multi stranded copper wire with a cross section of more than 0.5 mm 2. http://usbautoscope.eu/ 13

5. Manufacturer limited warranty The manufacturer guarantees the performance of the USB Autoscope Lite during its warranty period. Warranty period for the main unit USB Autoscope Lite is 24 months from the date of sale. During the warranty period, the manufacturer will at their discretion, replace or repair components that failed due to a manufacturing defect or during normal use. Failures caused by abuse or neglect, are not covered. This warranty gives you specific legal rights and you may have other rights that vary, depending on where you reside. 6. Troubleshooting 6.1 The device does not turn on The device is not connected to USB 2.0 12 Mbit/s (Full-SPEED) port of the host computer. Connect the device to USB 2.0 12 Mbit/s (Full-SPEED) port of the host laptop or PC. Faulty, low-speed or too long USB cable. Change the USB cable to a quality high-speed USB 2.0 A/B interface cable of no more than 3 meters in length and with a label stating "CERTIFIED Full-SPEED USB". The driver for "Universal Serial Bus controller" is not installed. Install the drivers for the motherboard that is in your computer. The USB 2.0 12 Mbit/s (Full-SPEED) port of the personal computer is broken. Try another port or computer. 6.2 "USB transfer error" If in the process of working with the device in the USB Oscilloscope window the message USB transfer error appears, it indicates distortion and/or damage to the data that are sent via the USB interface. The device and / or its USB cable placed too close to the source of electromagnetic interference. Ground the device using a separate multi stranded copper wire with a cross section of more than 0.5 mm 2. Used faulty, low-speed or too long USB cable. Change the USB cable to a quality high-speed USB 2.0 A/B interface cable of no more than 3 meters in length and with a label stating "CERTIFIED Full-SPEED USB". v4.4.9.7 http://usbautoscope.eu/ 14