Release Notes for MotionWorks IEC

Similar documents
Release Notes for MotionWorks IEC Release a

Release Notes for MotionWorks IEC

Release Notes for MotionWorks IEC

Release Notes for MotionWorks IEC

Release Notes for MPiec controller firmware

Release Notes for MP2000iec controller firmware

Release Notes for MP2000iec controller firmware

MotionWorks IEC Hardware

ACE Operation Manual

MULTIPROG QUICK START GUIDE

Colligo Engage Outlook App 7.1. Offline Mode - User Guide

Manual Supplement. Manual Title: 2680A/2686A Users Supplement Issue: 1 Print Date: June 2002 Issue Date: 9/06 Revision/Date: 1, 4/04 Page Count: 9

PLCopen Part 4 Coordinated Motion

WebStudio User Guide. OpenL Tablets BRMS Release 5.18

Upgrade Information for MPE720 Version 6.10

Product Demo Instructions. MP2600iec Demo Instructions: v03. Applicable Product: MP2600iec with MotionWorks IEC Pro

Release Notes Life Technologies Attune NxT Software v2.3

Global Programming Standard

QuickStart Guide. Configuring a RedLion HMI to communicate with an MPiec Controller via MODBUS/TCP using Crimson 3

Product Application Note. MP2000iec Address Mapping between a Phoenix MII BK unit and an MP2000iec controller. Applicable Product: MP2000iec

Remote Process Explorer

MPiec Web User Interface

This is a known issue (SVA-700) that will be resolved in a future release IMPORTANT NOTE CONCERNING A VBASE RESTORE ISSUE

Fiery Driver for Windows

Scan Station 710/730 Release Notes:

Release Notes RESOLVED NEW NEW

Chapter 2 Using XG5000 Software. 2.1 Screen Configuration. XG5000 screen is composed as shown below. [Screen of XG5000]

VMware Mirage Web Manager Guide

Fluke 1750 Power Analyze

for Windows Release Notes: Version September 12, 2013 Document version: MINDJET Page 1

Upgrade Information of MPE720 Version 7.46

Legal Notes. Regarding Trademarks KYOCERA MITA Corporation

AccessData Forensic Toolkit Release Notes

Colligo Engage Outlook App 7.1. Connected Mode - User Guide

If a project set to Samba includes a Socket Init function set to protocol HTTP, a compilation error now results. (Samba does not support web server)

XenClient Enterprise Release Notes

KYOCERA Net Admin User Guide

IMPORTANT PRODUCT INFORMATION

VisionTools Pro-e v6.1

Upgrade Information of MPE720 Version 7.26

Avigilon Control Center 5.10 Release Notes

READ THIS INFORMATION FIRST Product: Remote IO Manager Software Release Remote IO Manager w/ Cable. Remote IO Manager Branding Toolkit.

Instruction Manual HIOKI Standby Power Measurement Software

Fixed problem with PointXYZ command's Z value changing to previous Y value.

Avigilon Control Center 5.4 Release Notes

What's new in WindLDR Version 6.47

ID Title Description of the restriction Solutions for the restriction

MagicInfo VideoWall Author

Exam : Title. : A+ OS Technologies

GX Configurator-DP 7.03

Legal Notes. Regarding Trademarks KYOCERA MITA Corporation

C-Bus Toolkit 1.15 Release Notes C-BUS

Colligo Manager for Outlook Release Notes. Release Notes

Quick instructions: Programming of SmartPLC AC14/AC4S with CODESYS V3

VMware Mirage Web Management Guide. VMware Mirage 5.9.1

Machine Controller MP900/MP2000 Series MPE720 Software for Programming Device USER'S MANUAL

CP30/G30/MC31 Firmware Version 3100 Known Issues

PIVOT CMS CLIENT SOFTWARE USER MANUAL

New Features: 1. Support auto device routing for MGate MB3270, MB3280, and MB3480 series.

Table of Contents 1 ABOUT THIS DOCUMENT GENERAL COPYRIGHT INFORMATION TERMS ABOUT THE GATEWAY PRODUCT FUNCTIO

Software Release Note

For DX100 for Industrial Robot MOTOMAN Ladder Editing Software for Personal Computers Ladder Editor 32 for DX100 Operator s Manual

KYOCERA Net Viewer User Guide

EXAMPLIFY TROUBLESHOOTING GUIDE

SIMOTION V4.1 SP2 HF3/HF4

Avigilon Control Center 5.0 Release Notes

ServiceMax Suite of Applications List of Fixed/Known Defects

Aurora Multi-image System Control Software. User Manual

Plasmon Diamond Library Manager

Anchor User Guide. Presented by: Last Revised: August 07, 2017

Upgrading. the Upgrading to Microsoft Dynamics GP 2015 Hot Topic.

Upgrade Information of MPE720 Version 7.30

N2KExtractor. Maretron Data Extraction Software User s Manual

Catalog 1 Product Overview General Important User Information About the Gateway Function Features Tec

Colligo Manager 5.4 SP3. User Guide

Contents. Platform Compatibility. Directory Connector SonicWALL Directory Services Connector 3.1.7

DataView Release Notes Version Released

ADOBE DRIVE 4.2 USER GUIDE

Trio Motion Technology 4-2. Motion Perfect v3

Application Note. Adding an MPiec Controller as an EtherNet/IP Adapter to Allen Bradley CompactLogixL32E. Applicable Product: MPiec, CompactLogix5332E

Installation and Operation Guide. LP Data View Software. BioLogic LP System

Software Release History. Version No. Build Date No./ Release Date. Bugs Fixed/Changes. Supported OS Apply to Models New Features/Enhancements

IEC PROGRAMMING

Windows

News in RSA-RTE 10.1 updated for sprint Mattias Mohlin, March 2017

Excel4apps Reports Wand User Guide (SAP) 2013 Excel4apps

Contents. Platform Compatibility. Directory Connector SonicWALL Directory Services Connector 3.1.7

Quick Reference Guide

DS-5 ARM. Using Eclipse. Version Copyright ARM. All rights reserved. ARM DUI 0480L (ID100912)

News in RSA-RTE 10.1 updated for sprint Mattias Mohlin, April 2017

News in RSA-RTE 10.1 updated for sprint Mattias Mohlin, July 2017

Getting started with JMobile Suite

KYOCERA Net Viewer 5.3 User Guide

DWG/DXF Export. Some attribute values in blocks weren't exporting correctly.

This package contains updated Toolbox PLUS software for configuring and monitoring Kingfisher CP-

Contents. Platform Compatibility. New Features. Secure Remote Access SonicWALL SSL VPN 2.5 Early Field Trial (EFT) for SSL-VPN 200

Copyright 2015 Integrated Environmental Solutions Limited. All rights reserved.

Vicon Valerus VMS 18R2 Update1 (Build 2)

Firmware Release Notes PREMIUM ETYPORT EXEC V5.4 TSX P M TSX P M TSX P M

Quick instructions: Programming of SmartPLC AC14/AC4S with CODESYS V3

Transcription:

Release Notes for MotionWorks IEC Release 3.5.0.106 June 23, 2018 (v1.1 update August 27, 2018) New Features Number Summary Release Notes 6694 : Changing Option Base type without removing option cards from the configuration is now supported. 7033 Global Replace replaces variables even if they are part of a structure and the name is too long 7186 User libraries are auto-compiled if required Option bases for MP3200iec and MP3300iec controllers can now be changed in without removing cards from the controller. Existing card modules in option bases will be automatically exchanged to new option base when possible. If cards for unavailable slots or incompatible cards are detected, the will query whether to proceed with the change that would remove those devices. Global Replace functionality in MotionWorks IEC has been improved for very long names involving structure variables. The build menu now has an option called Make Dependencies which will compile all referenced user libraries if necessary. 7857 LIO-Y1 option card Supported The LIO-Y1 option card is now supported by. 9187 Zipped (*.zwt) project now saves all nested user libraries 10369 Users can restore parameter sort to default view 10506 Total number of Mechatrolink axis nodes is displayed. 10528 IP address settings to be set as part of archive / configuration transfer 10721 MotomanSync EIP Adapter and Group configuration are supported in 10762 Acknowledge button added to Logic Analyzer Connected Variables Clear function When zipping a project (*.zwt), all referenced libraries of all directly referenced libraries will be included. Sorting drive parameters in has been improved. now displays axis counts in the Mechatrolink page. The number of online axes, offline axes, and virtual axes are visible beneath the Mechatrolink grid. All simulated and missing axes are counted as offline axes. In (HC), the option is added to change IP address of the target controller to match HC configuration. This is done with the Query to Update IP Address checkbox in the Controller Configurations Utilities dialog. now supports configuring an EtherNet/IP adapter device for MotomanSync robot controllers. There is now a confirmation prompt before clearing out the Logic Analyzer's connected variables in MotionWorks IEC to avoid accidental clearance. 10785 Logic Analyzer Improvements MotionWorks IEC now handles nicely a download changes attempt while logic analyzer is actively recording. The application now prompts to stop recording or to cancel download changes. Previously versions of application would end up in an error state that was difficult to recover. 11097 MotionWorks IEC converts older versions of user libraries when converting old projects When extracting user libraries from zipped projects, MotionWorks IEC now will prompt to automatically convert user libraries that were created in older versions of MotionWorks IEC. This behavior was present in versions prior to MotionWorks 3.4.0 but was inadvertently removed in version 3.4.0. Page 1 of 5

New Features Number Summary Release Notes 11137 Resource IP address displayed in Project Control Dialog 11156 XML file support for Exor Import / Export 11158 PAIF (Pre-aligner) and 266IF (Profinet) option cards are supported in 11172 Oriental Multi-Axis Stepper Mechatrolink-III supported in 11297 Support libraries for MotomanSync added. 11333 Added support for the 8-slot backplane required for the RM100 robot controller. 11361 PLCopen Part 4 stub functions into PLCopenPart4 library. 11430 Added MC_CARTESIAN_REF_TO_VECTOR and VECTOR_TO_ MC_CARTESIAN_REF function blocks to PLCopen Part 4 library. Project Control Dialog now displays resource name and IP address in MotionWorks IEC. The HMI Export feature for Exor JMobile software now exports in JMobile s XML format, which accepts additional information regarding the necessary byte swapping for a more seamless interoperation. now supports configuring the 266IF-02 option card (PROFINET communication slave module, JAPMC-CM2307-E) and PAIF option card (Pre-Aligner module, JAPMC-PA2300S-E) for MP3300iec controller. Mechatrolink-III steppers from Oriental Motor are now supported. This release now includes the user libraries required to communicate with remote hosted robot controllers such as the YRC-1000. now supports option base part number JEPMC- BU3322-E for MP3300iec controllers. This option base is required for the RM100 MotomanSync robot control card module (part number JAPMC- RM3301R-E). (RM100 not fully supported in this release.) This was a design change to reduce the number of libraries included in a PLCopen Part4 project which includes Mechatrolink based groups. The Group_Stub library is no longer necessary when using PLCopenPart4_v350. These are functions to make it more convenient to switch between data types. 11561 Added Y_SelectTool for MotomanSync Groups 11571 Added support for Sigma7 FT82 Mechatrolink-III drives Sigma-7S FT82 option drive for special motors and SGM7D motor is now supported by. 11581 Improve Y_Jog* blocks so moves don t judder if used in relatively slow task. Y_Jog* blocks have been updated to improve their performance when used in slower tasks. 11667 Show Borders feature set is no longer on as default. Borders in the graphical editor have been turned OFF by default in MotionWorks IEC 3.5.0 due to borders (colors) affecting collision detection and TB mode display. The 3.4.0 release had turned borders ON by default. Show Borders can be configured at the 'Graphical Editor (2) tab' of the Options dialog. 8042 Disallow adding a 218IF-Y1 option card to MP3200iec in Hardware Configuration no longer allows configuring MP3200iec controllers with a 218IF-Y1 Communication card. Previously this configuration was allowed by even though such a configuration does not boot up correctly for MP3200iec controllers becuase the card is not supported by this controller. Page 2 of 5

8709 10873 10962 10963 10981 11250 11266 11267 11305 11328 11356 11357 11390 11465 MotionWorks IEC open/save dialog should reference the last open/save folder, not the default project path. Ctrl-Scroll Wheel zooms backwards for variable worksheets Internal Error! when global variables are assigned an incorrect datatype in %M Registers Accidentally putting a User-defined data type as an array index causes "Error During Generating native Code" compile error MotionWorks IEC crashes when zipping projects with 'Zip Pagelayouts' selected MotionWorks IEC crashes when an array variable with a variable index is added to the watch window or Logic Analyzer Drag-and-Drop is not prohibited when project is set to "released" Project is marked as "released" still allows to be changed. Download Changes causes a PLC watchdog VIPA SLIO: Runtime Exception: Invalid structure for reading or writing ProConOs I/O Driver Revert to allowing LD/FBD right power rail to be optional Mechatrolink-III ServoPack input status incorrect. Note: This may require programming changes if original project was done in v3.4.0. Force Axis Names to be unique Group Stop caused by changing Y_GroupInputs.ControlMode input causes group to get stuck in GroupStopping state Open Project and Save Project As dialogs for MotionWorks IEC now retain and use the last opened or saved directory. When using Ctrl+Scroll Wheel to zoom in a POU worksheet and a variable grid, the behavior was different. Scrolling the wheel up now zooms in (bigger) and scrolling the wheel down zooms out (smaller), the same as in POU worksheets. Error handling for incorrect address prefixes assigned to user defined structure type variables has been improved. For example, assigning the address prefix 'X' to an AXIS_REF type variable s address (which is not a bit). The error is now specifically identified; "Go to error" functionality and double-clicking on this compile error will go to the source of the error. Error handling when using non-integer array indexes has been improved. The error is now specifically identified; "Go to error" functionality and double-clicking on this compile error will point to the source of error. This crash, which would only occur in MotionWorks IEC 3.4.0 on Windows 7 has been fixed. This bug has been fixed. Example of variable added: "BoolArray2[Index]" Bug has been fixed where MotionWorks IEC would allow a project marked as "released" in the versioning to drag-and-drop items in the project tree to change the project structure order. no longer allows changes when the project is marked as 'Released' in the right click properties of the Project Tree Window. An error message will now be displayed in this scenario. This condition, which occurred frequently after being prompted to allow real-time violation, caused a watchdog. This problem has been corrected. There were some VIPA SLIO configuration scenarios which could lead to incorrect Configuration Instance data in the configuration file IO.XML, and cause a failure to start the driver communication with the VIPA device. The right power rail is optional again in ladder diagrams. MotionWorks IEC 3.4.0 unconditionally required the right power rail. Default values for Mechatrolink-III ServoPack output signal monitor selection parameters (Pn868, Pn869, and Pn86A) have been modified to be 0x0000 (disable output signal monitors) to avoid conflict with input signal monitor selection parameters (Pn860 to Pn866). MotionWorks IEC 3.4.0 had enabled the Mechatrolink-III ServoPack output signal monitors, so project created in 3.4.0 with Mechatrolink-III ServoPacks should be modified to disable the Mechatrolink-III ServoPack output signal monitors whenever input signal monitors are used. Bug was fixed for allowing insertion of multi-axis drives where default axis name for secondary axis is already used in configuration. This bug has been fixed, a group will no longer get stuck in the stopping state. Page 3 of 5

11480 Cannot copy and paste parameters from SGD7 400V Bug has been fixed in that prevented parameter copy and paste between non-standard Sigma-7 drives. Known Issues Number Known Issue Details Workaround 825 Project file name length is limited to 24 characters 875 does not run when launched by a user who did not install it and who does not have Administrator privileges 1034 Cannot connect to the controller from the if DNS reverse and forward lookups contain mismatching entries 1165 Single Step debug does not always work 1516 Project source code stored on controller has wrong extension in express (ZipFile.zwt, should be.zwe) 1693 Slow compilation when Symantec Antivirus is enables 5753 Logic Analyzer does not upload data when toolbar button "Stop recording values" is pressed. 5833 I/O group address range does not match text in global variables I/O group name 6622 Project Wizard does not behave as expected. File name length is limited to 24 characters which can cause issues when saving. Administrative privileges are required to install on Windows Vista or higher If the DNS reverse lookup for the controller IP address returns a host name that has a forward lookup to a different IP address, then connection with the will fail. On MP2300Siec and MP2310 only, single step debug mode does not work if multiple instances of a function block exist. The editor will display the wrong instance with incorrect debug values. Project source code is saved with wrong extension for MotionWorks IEC Express usage (ZipFile.zwt, should be.zwe) when downloading the source code to the controller. Compiler runs slowly when Symantec Antivirus is enabled. Logic Analyzer will not upload data after pressing the stop recording value button. The log buffer must fill up first for the data to be transferred. Editing the name of EtherNet/IP or Modbus device, or adding and deleting devices with the same settings can cause a disconnect between I/O Groups and Variable Groups that can cause the variable addresses to be unrelated to I/O group address range. In some circumstances, the Project Wizard will not create a new project. Use a filename with 24 characters or less. Login with Administrative privileges before installing. Use a different IP address for the controller or fix the DNS entries on the DNS server. If other instances are unused, delete those instances of function blocks before debugging. Otherwise, debugging can proceed if you click on the correct tab for the proper instance after each time the code stops at a breakpoint. After uploading from the project archive from the web interface, extract Zip File.zwt, change file extension to.zwe before opening it with MotionWorks IEC Express. Exclude MotionWorks IEC file types from virus scan. File types: cic, dbd, dip, dit, diw, st1, sto Use continuous trace data logging. Save the between deleting a device and reentering it. For new projects, use the project templates instead of the Project Wizard. Page 4 of 5

Known Issues Number Known Issue Details Workaround 6628 Continuous trace mode shows a value of -1.#QNAN0 if debugging mode is stopped and restarted 6795 Unidentified Unicode text strings when using "Language for non- Unicode programs" setting 7052 After Communication Time out, Controller Utilities is Unavailable 9868 Occasionally all keystrokes in a POU will stop working after using 11452 IMEMCPY, MEMCPY, MEMSET firmware function blocks moved from PROCONOS firmware library to LegacyProConOS firmware library 11577 experiences significant slowdown on Windows 10 when using Controllers Configuration Utilities. 11766 MotionWorks IEC sometimes freezes if user uses "Create Global Variables from Externals' function. Continuous trace mode cannot guarantee that samples will not be dropped. When samples are dropped due to CPU overload or other reasons, a value of "-1.#QNAN0" will appear when the data is exported. This occurs when the MotionWorks IEC language is set to Japanese or Simplified Chinese on an English language OS. There are some situations where the displayed text is unidentifiable; a series of question marks are displayed instead. When online, if communication to the controller is lost the Online Menu has items enabled and disabled as if the controller is still online. On some computers, interacting with the window will cause all keystrokes in MotionWorks IEC to be intercepted, causing the keyboard to become nonfunctional within the program. Not all computers are affected. The problem can occur in computers with.net 4.0 and 4.5. The MEMCPY and IMEMCPY function blocks are replaced by the MEMORY_COPY function block which is more stable than the older version. MEMSET function block is replaced with MEMORY_SET. Closing the Controller Configuration Utilities box in takes several seconds longer when using Windows 10. There is a bug with multiple executions of the 'Create Global Variables from Externals' functionality in the same session that may cause MotionWorks IEC to freeze. The application needs to be killed and restarted to resume usage. For a more accurate trace use non-continuous mode. 1. Using Windows Update, install all the Asian language packs. 2. Set the language for non-unicode programs to Japanese: Settings Control Panel Region and Language Administrative Change my system locale Use Japanese formats: Settings Control Panel Region and Language Formats This can be corrected by attempting to go online again. Using the invalid menu items does not produce any negative result. Updating to the most recent.net 4.5.1 framework resolves this issue. Replace old function blocks with MEMORY_COPY or MEMORY_SET FBs now in the PROCONOS library. (Alternately, include the firmware library LegacyProConOS in the project to continue using the older function blocks.) No workaround. Close and restart MotionWorks IEC before executing again 'Create Global Variables from Externals'. Page 5 of 5