MR50 READER INTERFACE

Similar documents
MR52 READER INTERFACE

MR51e Reader Interface

SINGLE READER EXPANSION MODULE

EP1501 Intelligent Controller

MRDT Display Terminal

Magnetic Card Reader. Contents

SR10k Mag-Stripe Access System Users Guide

CA-A480-A Elevator Controller. Reference & Installation Manual

Mercury Installation Manual

TruPortal Dual Door Interface Module Quick Reference

Two Door Controller GEN-045

emerge Essential Access Control System

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

CYPRESS " " EXP SPX Expansion interface! modules EXP-2000_MAN_0314

Suprex RS-485 SPX-7500 Wired Reader-Extender

UC-2000 Installation Manual Unicorn Computers Technology Limited

Quick Start Installation Guide

genesis TECHNICAL MANUAL Two-Door Controller GEN-045

DIN-191 and DIN-192 SERIES CONVERTER BOXES USERS MANUAL

Integrated Stepper Drive & Motor

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters

ES-600 Ozone Controller Operation Manual

CI-1 and CI-8. Communications Interface Betsy Ross Drive Santa Clara, CA (408) FAX (408) P/N Rev.

VertX. V100, V200 and V300. Installation Guide Barranca Parkway Irvine, CA USA. November Rev A.1

BACnet Router Start-up Guide

Proximity Card and Pin Reader Installation Manual

ACLD Channel Opto-isolated Digital Input Board

genesis genesis Expander Unit - Technical Manual TECHNICAL MANUAL Australian Owned, Designed and Manufactured Expander Unit GEN-010

SPX Supervised Reader Extender. Wiring Diagram and Operators Manual MAN-FA-SPX-1200 V1.03

232iLM Keypad Installation and Programming Instructions

genesis Master Unit GEN-001 genesis Master Unit - Technical Manual TECHNICAL MANUAL Australian Owned, Designed and Manufactured

USER MANUAL CCHP-6000-XX 6kJ/s Capacitor Charging Power Supply

MD9 MULTIDROP INTERFACE INSTRUCTION MANUAL

TB21. NO - Relay. Relay. Common - Relay. NC - Relay. Input J23. Ground TB22 TB23. NO - Relay Common - Relay NC - Relay Input Ground.

USB Ranger User Guide. Cat 5 USB 2.0 Extender with Remote Power. Powered by

WIEG-EXT Wiegand to RS485 extender module.

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

AC-225. Advanced Scalable Networked Access Controller. Hardware Installation and User Guide

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features

AC-215x-B Series 2-Reader Networked Access Control Panel Hardware Installation and User Manual. Models: AC-215-Bx AC-215-DIN AC-215IP-Bx AC-215IP-DIN

SCD96 DMX Output Interface. Installation guide

V-9908 MESSAGE/PAGE PANEL

Power Connection Options

SCP Hardware Quick Reference

TAC I/NETTM 1284, 1280, Security Control Unit

RS-485 Fiber-Optic Link RS-485 to Multi-Mode Fiber-Optic converter ST Fiber Connectors DIN Rail Mount

USB Ranger 110/410 User Guide

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range

PMDX-105 Quad Isolator Board

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

M-SWITCH SWITCH INPUT IN GAS CONTROL SYSTEM INSTALLATION OPERATION AND MAINTENANCE MANUAL

CAN Fiber Optic Modem

USER MANUAL. MODEL 2014 Interface Powered RS-530 to V.35 Converter. SALES OFFICE (301) TECHNICAL SUPPORT (301)

PRO3200 Professional Modular Access Control Hardware

OP8/16 Optoisolated Digital Input Board User's Manual

SMD Series Integrated Stepper Driver and Motor Revision 1.3

Suprex Fiber Optic. Reader-Extender SPX-7400 SPX Product Manual. Reader-Extender. Manual. SPX-7400 Series EXP Suprex_FiberOptic_MAN_170502

USB 2.0 Ranger Port USB m CAT 5e/6/7 Extender System. User Guide

SPX-7400_SPX-7410_MAN_161028

BACnet Router Start-up Guide

USB 400 FO. EXT-USB-400FON. User Manual

V-9964 Digital Feedback Eliminator/Message Stacker

KT-300 DOOR CONTROLLER INSTALLATION MANUAL DN KANTECH SYSTEMS INC.

User's Guide. MiniTec TM Series Model MN25 MultiMeter

User's Guide. Extech AM A AC Analog Clamp Meter

DESIGN GUIDE FOR INFINITY SYSTEMS

PR602LCD v1.0 Installer Manual Rev. A

Technical Practice BP-2 POWER FAILURE TRANSFER UNIT. Issue 8, April 1988

NXT-1R/-3R/-5R Exit Reader Installation Drawing 4-Conductor - OR - CAT-5 Cabling. IO-Plus (Green) Ground (Black) +12 VDC (Red) Shield (Silver)

User's Guide. Phase Sequence and Motor Rotation Tester Model

INSOMNIAC CIA G-600 Gateway Installation Manual P/N CIA Revision 1.0 Date Code:

Long range Multi Reader AY-Z12A Installation Guide

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL

R325P Single Axis Driver

Installation Instructions

Suprex RF Series CYPRESS. Operations Manual. Suprex Reader Extender - RF Wireless Interface EXP SPX Mhz SPX-5521_MAN_0316

USB Ranger 422 User Guide

Quick Start Installation Guide

Power Hub Cat. No. 83A00-1. Installation Manual WEB VERSION

MODBUS MANUAL For the AccUView UV Transmission Monitor

American Power Design, Inc.

MODEL: R1M-D1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

INSTALLATION GUIDE DM-20 English Version 1.10 EN DM20 V1.10A

4300 WINDFERN RD #100 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

INSTALLATION INSTRUCTIONS FOR THE MINI-KEY SYSTEM. Doc Rev B

AC-225x-B Series. Expandable 2-Reader Networked Access Control Panel Hardware Installation Manual. Models:

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L MONITORED DEVICE

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

EASON TECHNOLOGY. IO8 & IO24 Break-Out Module

Mercury Products Open Platform Solution

Tempco Instruction Manual

USB 2.0 Ranger Port USB m Cat 5e Extender System. User Guide

USB Ranger Fiber Optic USB 2.0 Extender. User Guide

THE BRIDGE. Make any Wiegand device wireless with the Sure-fi Bridge FEATURES. Technology

Access Control System Document Number: , Rev. D. Installation Guide. Essential Essential Plus Elite 36 Elite 64

INSTALLATION & OPERATING INSTRUCTIONS

OZONE SWITCH Model OS-6. OS-6 Features

Proliphix EPA-60 Installation Guide

4300 WINDFERN RD #100 - HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

The SH8RP Board. Introduction CASI RUSCO

Transcription:

2.75 [69.9] 2.35 [59.7] U1 MR50 READER INTERFAE Installation and Specifications: 1. General: www.mercury-security.com 2355 MIRA MAR AVE. LONG BEAH, A 90815-1755, (562)986-9105 FAX (562) 986-9205 This device complies with part 15 of the F Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. The MR50 reader interface provides a solution to the OEM system integrator for interfacing to a TTL/Wiegand/RS-485 type reader and door hardware. The MR50 can accept data from a reader with clock/data, Wiegand signaling or 2-wire RS-485, also provides a tri-stated control and buzzer control. Two Form- contact relay outputs may be used for strike control or alarm signaling. Two inputs are provided for monitoring the door contact and exit push button. ommunication to the interface is accomplished via a 2-wire RS-485 interface. The MR50 requires 12 to 24 Vdc for power. 0.20 [5.1] STATUS s Ø0.156 [Ø4.0] 4 PLAES D1 J6 J5 B A TB2 VIN 0.20 [5.1] 3.85 [97.8] 2. Power, Reader and Door Hardware Wiring: 4.25 [108] TAMPER INPUT, RMALLY LOSED All interconnections to the interface are via quick-disconnect terminal blocks. The MR50 requires filtered 12 to 24 Vdc±10% for power. The MR50 supports clock/data, Wiegand or 2-wire RS-485 reader interface signaling. Two inputs are typically used for door contact and exit push button monitoring. End of line resistors are required for line supervision. Note: The input power is passed through to the reader terminal strip and is available for powering a reader. are must be taken to insure that the input voltage is within the voltage range of the reader. GROUND BUZZER READER A1/LOK/ A0/A/ READER POWER SIO OMM. RS-485 INTERFAE GROUND TAMPER, LK D1 TB2 VIN RMALLY LOSED OMMON STRIKE RELAY () RMALLY OPEN RMALLY OPEN RMALLY LOSED AUX. RELAY () OMMON +12 to 24 Vdc INPUT LTAGE INPUT LTAGE RETURN EXIT REQUEST RMALLY OPEN DOOR ONTAT RMALLY LOSED Mercury Security orporation 2009 MR50 DO 10107-0009 REV 2.02 Page 1

MR-10/20 READER Reader Wiring: BLK (6) ORG (5) BRN (4) WHT (3) GRN (2) RED (1) D1/LK/T+ //T- MR-DT GROUND (BLAK) (2) (BLUE) (3) (GRAY) (4) 12Vdc (RED) (1) D1/LK/T+ //T- A1/A0 - LOK/A READER PORT RS-485 MODE 9600 BAUD ADDRESS 0 READER PORT Door Strike Relay Wiring: Two Form- contact relays are provided for controlling door strike or other devices. The contact ratings are 5 A for relay and 1 A for relay. Load switching can cause abnormal contact wear and premature contact failure. Switching of inductive loads (strike) also causes EMI (electromagnetic interference) which may interfere with normal operation of other equipment. To minimize premature contact failure and to increase system reliability, contact protection circuit must be used. The following two circuits are recommended. Locate the protection circuit as close to the load as possible (within 12 inches [30 cm]), as the effectiveness of the circuit will decrease if it is located far away. Diode Selection: Diode current rating: 1x strike current Diode breakdown voltage: 4x strike voltage For 12 Vdc or 24 Vdc strike, diode 1N4002 (100V/1A) typical MOV Selection: lamp voltage: 1.5x Vac RMS. For 24 Vac strike, Panasonic: ERZ-07DK470 typical Mercury Security orporation 2009 MR50 DO 10107-0009 REV 2.02 Page 2

3. ommunication to a ontroller: TO ADDITIONAL SIO UNITS MR-50 LAST UNIT ON OMMUNIATION LINE - TERMINATOR INSTAL MR-50 ONTROLLER The MR50 communicates to a Mercury Security intelligent controller (EP2500 for example) via a half duplex multi-drop 2-wire RS-485 interface. The total cable length is limited to 4,000 feet (1,219 meters). Shielded cable of 24 AWG with characteristic impedance of 120 ohm is specified for the 2- wire RS-485 interface. The last device on each end of the communication line should have the terminator installed (set jumper on). Address, Baud Rate and Encryption onfiguration Jumpers: Each Interface (MR50, MR52, etc.) must be configured to have a unique address and correct baud rate. The address and baud rate are selected by installing the specified jumpers. Note 1: Firmware revisions prior to 1.39.1, the 115200 baud rate setting is 2400 baud. Note 2: Firmware revisions prior to 1.39.1, jumper 8 is not defined, remove jumper. Mercury Security orporation 2009 MR50 DO 10107-0009 REV 2.02 Page 3

4. Status s: Power-up: All s OFF. Initialization: Once power is applied, initialization of the module begins. The A is turned ON at the beginning of initialization. Run time: After a successful initialization, the s have the following meanings: A : Heartbeat and On-Line Status: Off-line: 1 second rate, 20% ON On-line: Non-encrypted communication: 1 second rate, 80% ON Encrypted communication:.1 S ON,.1 S OFF,.1 S ON,.1 S OFF,.1 S ON,.1 S OFF,.1 sec ON,.3 S OFF A Error Indication: Waiting for application firmware to be downloaded:.1 S ON,.1 S OFF. B : SIO ommunication Port Status: Indicates communication activity on the SIO communication port 5. Specifications: The Interface is for use in low voltage, class 2 circuits only. Primary Power: Outputs: Inputs: Reader Interface: 12 to 24 Vdc ±10%, 150 ma maximum (plus reader current) 12 Vdc @ 110 ma (plus reader current) nominal 24 Vdc @ 60 ma (plus reader current) nominal 2, Form- contact relays: : 5 A @ 30 Vdc, : 1 A @ 30 Vdc 2 unsupervised/supervised, standard EOL, 1k/2k ohm, 1% 1/4 watt 1 unsupervised, dedicated for cabinet tamper Reader power: 12 to 24 Vdc±10% (input voltage passed through) Reader output: TTL compatible, high > 3 V, low < 0.5 V, 5 ma source/sink maximum Buzzer output: Open collector, 5 Vdc open circuit maximum, 10 ma sink maximum Data Inputs: TTL compatible, mag stripe and Wiegand standards supported. RS-485 Mode: 9600 bps, asynchronous, half-duplex, 1 start bit, 8 data bits, and 1 stop bit. Maximum cable length: 2000 ft (609.6m) ommunication: able Requirements: Mechanical: 2-wire RS-485: 9600, 19200, 38400 or 115200 bps Power: 18 AWG, 1 twisted pair RS-485 I/O devices: 24 AWG, 120 ohm impedance, twisted pair with shield, 4,000 ft (1,219 m) maximum Alarm Inputs: 1 twisted pair per input, 30 ohms maximum, typically 22 AWG @ 1000 ft (304.8 m) Outputs: As required for the load Reader data (TTL): 18 AWG, 6 conductor, 500 ft (150 m) maximum Reader data (RS-485): 24 AWG, 120 ohm impedance, twisted pair with shield, 2,000 ft (609.6 m) maximum Dimension: Weight: 4.25 in (108 mm) W x 2.75 in (70 mm) L x 1 in (25.4mm) H 4 oz. (120 g) nominal Mercury Security orporation 2009 MR50 DO 10107-0009 REV 2.02 Page 4

Specifications (continued): Environment: Warranty: Temperature: Humidity: -55 to +85, storage, -40 to +75, operating 10 to 95% RH Mercury Security orporation warrants the product is free from defects in material and workmanship under normal use and service with proper maintenance for one year from the date of factory shipment. Mercury Security orporation assumes no responsibility for products damaged by improper handling or installation. This warranty is limited to the repair or replacement of the defective unit. There are no expressed warranties other than set forth herein. Mercury Security orporation does not make, nor intends, nor does it authorize any agent or representative to make any other warranties, or implied warranties, and expressly excludes and disclaims all implied warranties of merchantability or fitness for a particular purpose. Returned units are repaired or replaced from a stock of reconditioned units. Returns must be accompanied by a return authorization number (RMA) obtained from customer service, and prepaid postage and insurance. Liability: The Interface should only be used to control exits from areas where an alternative method for exit is available. This product is not intended for, nor is rated for operation in life-critical control applications. Mercury Security orporation is not liable under any circumstances for loss or damage caused by or partially caused by the misapplication or malfunction of the product. Mercury Security orporation's liability does not extend beyond the purchase price of the product. Mercury Security orporation 2009 MR50 DO 10107-0009 REV 2.02 Page 5