USER GUIDE PEL 8K / PEL 8K-M

Similar documents
USER GUIDE PEL / PEL-M

USER GUIDE TEx LU / TEx-M

USER GUIDE TEHR LU / TEHR-M

HPS-M -2 DIFFERENTIAL PRESSURE TRANSMITTER. Mounting and operating instructions

Differential pressure sensor For ventilation and air-conditioning Model A2G-50

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

BQ & BQ370-01N MODBUS ANALOG INPUT DEVICE USER MANUAL

Carbon Monoxide Sensor - ModBus

MOD-RI Room Interface Modules with Modbus

HLS34 Modbus FCU/VAV Controllers installation instructions

MXIO. Compact I/O module. Summary. Application Compact I/O module for data acquisition and HVAC control systems. Function

Trident and Trident X2 Digital Process and Temperature Panel Meter

MOD-IO9 Modbus Input / Output Modules, Wall Mounted

PCD DIGITAL Differential pressure probe

Data sheet * * Digital 2-channel transmitter for direct connection to bus-capable automation devices. Design and mode of operation

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

DIFFERENTIAL PRESSURE TRANSMITTER with MODBUS interface Optional Input module

Dual differential pressure sensor For ventilation and air-conditioning Model A2G-52

TOTALFLOW Technical Bulletin 113

Version 1.0c May 6, 2010 ATK3

T2314, T2414. Instruction Manual

Gastrack Gas Analyser

FT2 View Instruction Manual

sensor, which compensates for ageing effects, is highly insensitive to pollution and offers outstanding long term stability.

FCU-MULTI Modbus Fan Coil Unit Controller

RXTP ROOM TEMPERATURE

USER S GUIDE. EE210 - Humidity and Temperature Transmitter for demanding Climate Control Applications GENERAL

CDD ModBus Carbon Dioxide Detector

LM24A-MOD. Cable 1 m, 6 x 0.75 mm 2 RJ12 socket

KTA-250 Anemometer Alarm Card

USER MANUAL. Modbus IHP24-A IHP24-AF IHP24-B IHP24-BF IHP24-F IHP24-I 1/26

Installation Guide. Section 1 - Room... pg 03. Section 2 - Duct... pg 23. I-CDD3_Modbus Installation. Modbus Gas Transmitters I-CDD3 Series

Gas and Air Sensors. Product Specification. CO 2 Engine K30. Sensor Module and OEM Platform. Document PSP 110. Rev 4. Page 1 (11)

DL-10. User Manual. RS-485 Remote Temperature and Humidity. English Ver. 1.0, Jul. 2017

T2314, T2414. Instruction Manual

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

Tango. alpha nea. Thermometers and controllers with digital communication - Series AM

Golander Peristaltic Pump MODBUS Communication Instruction

TORRIX RS485. Technical Documentation. with MODBUS Protocol. Edition: Version: 2 Art. no.:

DP DP2500 DP0250

ATK3 I/O Module (Modbus Slave)

DPA+ LCD. Application. Types Available. Differential Pressure Transmitter. Datasheet

HART 710. User s Manual Version HART-710 User Manual (Version 1.00, July/2010) PAGE: 1

Communicative controller for VAV systems

RS485 MODBUS Module 8AO

HRT-710. User s Manual Version HRT-710 User Manual (Version 1.23, Dec/2012) PAGE: 1

Table of Contents. General Information. Document Sure-Aire Flow Monitoring System. User and Service Manual WARNING CAUTION

TRAINING GUIDE LEVEL 3 MODBUS WRITE IMPORT COMMAND

Signal Isolators & Conditioners

Uponor Smatrix Move PRO Controller X-159 Modbus RTU interface

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.

Modbus Communications Board

EE160 - Humidity and Temperature Transmitter for HVAC Applications

THM501 PT100 MODBUS TEMPERATURE TRANSMITTER

TRANSDUCER T4311, T4411

F-3100 FLOW METER NETWORK INTERFACE Installation and Operation Guide

Modbus Communications Board

BQ351 MODBUS IO DEVICE USER MANUAL

Intech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual.

Wireless Transducer MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. (407) Phone: Website:

High Voltage DC Meter

Modbus Manual Version Modbus Manual for PF4/5

RS-FS-N01 Wind speed transmitter user's Guide (485type)

Differential Pressure Controller DPC 200

19.Configure HMI as a MODBUS Server

CDD4 Duct Carbon Dioxide Transmitter

Hydrostatic filling level sensor HFB C4 / R / MD

VAT series controller and transmitter. Manual

HIGH-VOLTAGE DC METER

Product Specification for SAB-S-MODBUS

RXTH DUAL ROOM SENSOR / SWITCH

ELSETA IOMOD 8DI8DO. User manual. Elseta 3/2017 V1.0

CuteLine AIN8 UI - Voltage Current. Manual

Installation manual CF8-W-Disp-AL

Fox Thermal Instruments, Inc.

RTD-W Installation Instructions

VISY-Command. Technical Documentation. with Modbus Protocol. Edition: Version: 1 Art. no.:

Specification Sheet For electronically commutated motors

Supply Voltage V dc Supply is fully isolated internally, and protected against transients. Internal power modules are CE certified.

Product Specification. CO 2 Engine K30 STA. Sensor Module and OEM Platform

Product Specification. Sensor Module and OEM Platform

H7625A, H7635A Humidity/Temperature Sensors

Instruction Manual. T3110 T3110L T3110Ex

H7625B; H7635B,C; H7655B Duct-Mount and Outdoor-Mount Humidity/Temperature Sensors

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for

asense m III in industrial wall mounted housing / CO sensor with built-in general purpose controller

Flow Computer compart DXF 351. Universal Application for Gas, Steam and Liquids

The benefits are ease of set-up, more data available for the user from the drive, fast control, and state of the art technology.

Level monitoring system NT 3500 Technical information / Instruction manual

List of Contents 1. INTRODUCTION DEFINITIONS AND ABBREVIATIONS REFERENCES TECHNICAL DATA GENERAL MODBUS RTU...

MODBUS Message Protocol MODEL FT3

Insertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 )

PG AB Omron FINS to Modbus RTU Protocol Converter

RTD-NET Installation Instructions

lindab we simplify construction UltraLink Technical information

Technical Specificaions. kwh Energy Meter

Transcription:

V2.0.0 (24.10.2014) 1 (7) COMMISSIONING Mounting - The transmitter should be installed above the measuring point to avoid condensation problems. - The duct overpressure is detected by connecting the measuring point to + connector and by leaving the - connection open (surrounding space pressure). Accordingly, the duct under-pressure is detected by connecting the measuring point to - connector and by leaving the + connection open. - Install the measuring hoses carefully so that the hoses don't bend too tightly. Too tight curves may prevent the air flow to the sensor. - The hose length doesn't effect on the measuring accuracy. However, long hoses generate delay on the measurement. Wiring Device wiring and commissioning can only be carried out by qualified professionals. Always make the wirings while the power is switched off.

2 (7) Selecting the measuring range The measuring range can be selected with the jumpers S2, S3 and S4. A. Pressure selection jumpers S2 S3 S4 0 1000 0 1500 0 2000 0 2500 0 3000 0 4000 0 5000 0 8000 * ) * ) Factory setting. The 0 8000 Pa range is also used for the custom range setting. The custom range is 0 8000 Pa as a default. The range can be changed by using ML-SER tool or by defining the high limit to the Modbus register 40002 (the low limit is 0 Pa). Selecting the time constant The time constant can be selected with the jumper S1. A. Time constant selection jumper S1 * ) Factory setting. Selecting the output mode 2 s 8 s* ) The transmitter output can be either pressure linear or flow linear. The output mode can be selected with the jumper S5. A. Output mode selection jumper pressure linear* ) flow linear S5 * ) Factory setting.

3 (7) Flow linear output When the flow linear output is selected, the transmitter outputs are converted to follow the flow across the measurement area. The conversion is made by using square root extraction method. See the following figure for the output example in the 0 1000 Pa range: = Pressure linear output = Flow linear output ZERO POINT CALIBRATION ML-SER TOOL The purpose of the zero point calibration is to remove the possible long term drift. The zero point is calibrated automatically every five minutes. NOTE: The zero point calibration is also executed on the start-up and a minute after the start-up. With the ML-SER tool you can change the device settings, Modbus settings for example. Connecting ML-SER tool to the device 1. Remove the cover. 2. Disconnect the display cable (N models). 3. Connect the ML-SER tool cable to the display connector. A. Display connector When the ML-SER is successfully connected, the pressure measurement value is displayed on the ML-SER tool display. The connecting can take few seconds.

4 (7) ML-SER menu The device settings can be changed by using ML-SER tool. You can proceed in the menu by pressing the M and OK buttons. The values can be changed with the + and - buttons. The value is accepted with the OK button. The settings are saved when exiting the menu. The following menu structure contains the factory settings. The Modbus and analogue outputs are disabled when entering the menu for the measuring mode. In addition the analogue outputs maintain the same voltage, as they were before entering the menu. Communications menu (M models only) The Modbus settings can be changed through the COMMUNICATIONS menu.

5 (7) Custom range menu Output menu The CUSTOM RANGE menu is for setting the custom pressure range high limit. The custom range is in use when all the pressure range selection jumpers are placed. Info menu You can change the measurement output scales through the OUTPUT menu. The INFO menu can be used for checking the software version and resetting to the factory settings. Resetting to the factory settings 1. Press the - button for five seconds in the software version display. 2. Change the resetting dialog answer to yes. 3. Press OK button. The factory settings are now reset.

6 (7) MODBUS Bus properties Protocol RS-485 Modbus RTU Bus speed 9600/19200/38400/57600 bit/s Data bits 8 Parity none/odd/even Stop bits 1 Network size up to 127 devices per segment NOTE: The memory durability is 10000 write cycles. Bus termination The Modbus can be terminated by placing the Modbus termination jumper. A. Modbus termination jumper Supported Modbus functions 0x01 0x02 0x03 0x04 0x05 0x06 0x0F 0x10 0x17 Read Coils Read Discrete Inputs Read Holding Registers Read Input Registers Write Single Coil Write Single Register Write Multiple Coils Write Multiple Registers Read/Write Multiple Registers

7 (7) Modbus registers Data type: bit = 0 or 1 unsigned = unsigned integer (0 65535) signed = integer (-32768 32767) Input registers (read only) Register Parameter description Data type Value Range 30001 Pressure measurement signed -32768 32768-32768 32768 Pa 30002 Time constant unsigned 0 60 0 60 s 30003 Selected pressure range unsigned 0 7 0 = 0 1000 Pa 1 = 0 1500 Pa 2 = 0 2000 Pa 3 = 0 2500 Pa 4 = 0 3000 Pa 5 = 0 4000 Pa 6 = 0 5000 Pa 7 = 0 8000 Pa / custom *) 30004 Measurement output signed 0 1000 0 100,0 % *) The custom range is 0 8000 Pa as a default. The range can be changed by using ML-SER tool or by defining the high limit to the Modbus register 40002 (the low limit is 0 Pa). Holding registers (read / write) Register Parameter description Data type Value Range Default 40001 Not in use signed - - 0 40002 Custom scale high limit signed 1 80 100 8000 Pa 80 40003 Voltage output scale unsigned 0-1 - 2 0 = 0 10 V 1 = 2 10 V 2 = 0 5 V 40004 Current output scale unsigned 0-1 0 = 4 20 ma 1 = 0 20 ma 0 0