DVC Applications Mobile, Industrial, Agricultural, Marine or any other Hydraulic Equipment. 4 Simplified Connection Diagram

Similar documents
DVC700 Series. Programmable System Controller

DVC700 Series Programmable System Controller

DVC700 Series Controllers

DVC700 Series Controllers

TECHNICAL DATASHEET #TDAX050000K CAN

TECHNICAL DATASHEET #TDAX023300

TECHNICAL DATASHEET #TDAX023240

MC300. BLN Issued: April 2003

Quick Start Manual G2-2 Series with Ethernet Interface

March 21, BT22 Datasheet. Amp ed RF Technology, Co., Ltd.

In addition to fan control, many other hydraulic control applications can be accommodated with this hardware and application-specific software.

EMERALD SERIES AUTOMATION CONTROLLER JANUARY 2017 EMERALD EMC INDUSTRIAL INDEXING SYSTEMS, Inc. INSTRUCTION BOOK

MPCR Series DeviceNet Technical Manual TDMPCRDNTM2-0EN 01/08 Subject to change without notice

PHASED OUT PRODUCT DC2. Microcontroller DESCRIPTION FEATURES ORDERING INFORMATION. BLN Issued: June 1995

DeviceNet System Installation manual rev. 3.0

Product Specification

Allen-Bradley Automation

NUV300 Datasheet. Nuvation BMS Low-Voltage Battery Controller , Rev Copyright 2018, Nuvation Energy

BT 31 Data Sheet. Amp ed RF Technology Inc.

1) Examine exterior of package for signs of damage. Report any damage to shipping carrier.

Wiring Section 3-3. NQ-Series communication ports support various types of (serial) communication.

P/N: AX Applications: power gen set engine control systems oil and gas equipment automation off-highway machine automation

MLC 380 R2. For Mechanical Engines. Installation Manual

P/N: AX Distribute your control functions directly onto the valve.

INDUSTRIAL INCLINOMETER ANALOG & RS232 INTERFACE

Applications: Power generator sets and control systems for industrial engine applications.

Product Specification

S2C Link Accessory Kit Datasheet

Instruction book IQAN-LST. Publ no HY /UK Edition 0301

Inclination sensors 2-dimensional, measuring range up to ±90

01325T -- Robot Welder

BT-22 Product Specification

Hydraulic Fan Controller User Manual

E510. Compact Drive IP 20/ NEMA HP (230V) 1-75 HP (460V)

Technical Data Sheet OPUS A3 STANDARD Basic

EZ864 UMTS Terminal Telit Cellular GSM Engine

Absolute Encoders Multiturn

Ordering Part Numbers: TECHNICAL DATASHEET #TDAX BLDC MOTOR CONTROLLER P/N: AX100260

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Relay Deck Datasheet

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) OPERATION MANUAL

Technical Data Sheet OPUS A3 STANDARD Basic TDS OPUS A3sB,

Discrete I/O P/N: AXDIO inputs, 8 relay outputs, SAE J1939 with Electronic Assistant

Trouble Shooting Leveling Control Box Electric Jacks. Touch Pad LED Probable Cause Solution

Technical Data Sheet OPUS A3 STANDARD Basic TDS OPUS A3sB,

Hardware Manual RM CANview

GT- IRDM-9603 Product description Rev. 2 17/06/2014

MPCR Series DeviceNet Technical Manual

01348(N or G) MH** -- Material Handling (N or G) MH** -- Material Handling

G3 Series DeviceNet TM Technical Manual

TECHNICAL PRODUCT DATASHEET

250 Mbps Transceiver in LC FB2M5LVR

Technical Data Sheet OPUS A3 ECO Basic TDS OPUS A3eB,

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features

The LSI Gateway. GS220, GS221, GS222 series - LSI gateways. Features:

MasterFlux 48V Cascade BLDC Motor Controller Product Specification 030F0137

CONCEPT P/N: AX Concept TECHNICAL DATASHEET #TDAX Analog Input CAN Controller CAN (SAE J1939 or CANopen ) with Electronic Assistant

1) Examine exterior of package for signs of damage. Report any damage to shipping carrier.

PK2200 Series. Features. C-Programmable Controller. Specifications Board Size Enclosure Size Operating Temp.

Technical Data Sheet OPUS A3 ECO Basic

PRODUCT SPECIFICATION

FB2M5LVR 250 Mbps Fiber Optic LC Transceiver Data Sheet

EZ864 G. Telit Cellular GSM/UMTS Engine. Hardware guide Version: Update: 27. APR.2009 EZ864 G_Hardware Guide_V

ES-600 Ozone Controller Operation Manual

Electronic Control Unit RC

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

256 MB RAM. 256 MB 32 bits RISC Cortex-A8 600MHz SD Card Slot. N/A USB Host. N/A USB Client

Industrial Media Converters

HEAVY DUTY INCLINOMETER ANALOG & RS232 INTERFACE

MPCR Series Profibus-DP Technical Manual

User Manual. cmt-svr Startup Guide

User Manual. cmt-svr Startup Guide

Fan-Drive Controller. 1 Description. 2 Technical data ESLF101/ELLF General. 1.2 Models. 1.3 Application example. 2.

Note: the wiring of the dead-man buttons has been changed since October 2001.

PRODUCT DATASHEET DATE. This report provides appropriate specifications for the FRDS GENII relay enclosure.

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features

Safety: UL508 EMC: CE IEC , IEC Vibration: IEC (2 g s during operation) Warranty

TECHNICAL DATASHEET #TDAX Analog Signal Output CAN Controller (SAE J1939)

Instruction book IQAN-LSL. Publ no HY /UK Edition 0301

Temposonics. R-Series Profibus. Absolute, Non-Contact Position Sensors. Temposonics RP and RH Measuring length mm

MRS Electronic, Inc Winner Circle Dayton, OH (937) Datasheet CAN Relay Box 16. Page 1 of 8 Version 1.

Temposonics. R-Series Profibus. Absolute, Non-Contact Position Sensors. Temposonics RP and RH Stroke length mm

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) OPERATION MANUAL

C-Series C142 Machine Controller Eurocard DIN Packaged Systems

Power Amplifiers for PVH-EDC Pumps

MultiViu Flex 4 Data Sheet

RS485 MODBUS Module 8I8O

Installation Instructions for: Channel Thermocouple Amplifier

VISU-CB10 (VISU-Control-Board)

DSEM870. DSEControl PROGRAMMABLE DISPLAY FOR USE IN VEHICLES AND OFF-HIGHWAY MACHINERY

Discrete I/O 12 Discrete Inputs 8 Relay Outputs CANopen P/N: AXDIO128CO

Accessories: PL-DTM06-12SA-12SB Mating Plug Kit (1 DTM06-12S, DTM06-12SB, 2 W12S, 24 contacts) Electronic Assistant Configuration KIT: AX070502

2002 Series DeviceNet Technical Manual

Article no. BWU2045: AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input 1.23 NC

PRODUCT SPECIFICATION

Two Module Development Kit Installation and User Instructions For Model No. ED-GV15/30

H3G-48B Production Description

Connecting a Cisco Input Module

MT8050iE series. Installation Instruction (1) (2)

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) SUITABLE FOR EXTERNAL DISTRIBUTION

Transcription:

1 Description The is an Expansion module designed for use with the DVC707 / DVC710 Master Modules. The provides 12 sourcing discreet outputs that are capable of driving loads up to 3 amps each on 12 or 24 Volt control systems. Each Output is protected against shorts to ground and has open and short circuit detection that can be accessed through the application software. All Outputs may be individually configured to drive LED lamps. The is controlled by the master controller through its CAN Port. Baud rate and MAC ID settings as well as IO status and diagnostics are done through the serial port using the Intella Program Loader Monitor (PLM). The is encapsulated in a rugged plastic enclosure with an epoxy resin that provides the best possible resistance to external forces such as dust, liquids, debris etc. while providing superior vibration protection for circuit components. 2 Features 12, 3 Amp Sourcing Discreet Outputs Programmable LED mode for each Output Rs232 Port for setup and diagnostics CAN Port for system communication Water / Oil proof enclosure Industrial operating temperature range 12 or 24 Volt systems SAE J1939 Load Dump compliant Rugged, fully encapsulated module may be mounted on or near valve manifold 3 Applications Mobile, Industrial, Agricultural, Marine or any other Hydraulic Equipment 4 Simplified Connection Diagram Rev: 2, Datasheet Page 1

5 Connector Information Pin Out Pin Function Pin Function Pin Function A1 Output 1 B1 Output 2 C1 Output 3 A2 CAN H B2 CAN L C2 POWER COM A3 RXD B3 TXD C3 POWER COM D1 Output 4 E1 Output 5 F1 Output 8 D2 POWER COM E2 Output 6 F2 Output 9 D3 POWER COM E3 Output 7 F3 Output 10 G1 Output 11 H1 Output 12 J1 + POWER IN 1 G2 POWER COM H2 POWER COM J2 + POWER IN 2 G3 POWER COM H3 POWER COM J3 + POWER IN 3 K1 + POWER IN 1 K2 + POWER IN 2 K3 + POWER IN 3 NOTES: 1. Each Power pin used must be individually fused with an ATO 5, AGC 5 or smaller fuse 2. Power In 1, Power In 2 and Power In 3 are electrically separate Power Planes 3. Outputs 1 4 and the controllers on board logic is supplied from Power In 1 4. Outputs 5 8 are supplied from Power In 2 5. Outputs 9 12 are supplied from Power In 3 Mating Connector information HCT FACTORY ACCESSORIES Expansion Module Serial Port Adaptor: 999-10082 RS232 Cable Assembly: 999-10075 Mating Kit: 999-10085 Proto-Type Harness (3M): 999-10106 Rev: 2, Datasheet Page 2

6 LED Indicators A. Output Status (12ea 3mm Green LEDs) 1. Off output is off. 2. On output is on. 3. Blinking once per second Open Circuit 4. Blinking 4 times per second Short Circuit. B. Module Status (MS) (1ea 5mm Red/Green) 1. Off There is no power applied to the Module. 2. On green The module is operating in a normal condition. 3. Flashing green Device in standby state. May need commissioning. 4. Flashing red Recoverable Fault. 5. On red Module has an unrecoverable fault. 6. Flashing Red/Green Device is in self-test. C. Network Status (NS) (1ea 5mm Red/Green) 1. Off - Device in not on-line. 2. Flashing green Device is on-line but has not established connection to other nodes. 3. On green Device is on-line and has established connection to other nodes. 4. Flashing red One or more node connections are in a timed-out state. 5. On red The device has detected an error that has rendered it incapable of communicating on the network. Rev: 2, Datasheet Page 3

7 Electrical Characteristics Absolute Maximum Ratings Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Supply Voltage ±32 V DC Rs232 Port Rxd = ±15 V DC Txd = ±8 V DC CAN Port ±14 V DC Voltage at Input / Output Pin ±32 V DC Current at Power Pin 5,000 ma Current at Output Pin 3,000 ma Temperature Operating -40 C to +85 C Storage -40 C to +100 C Recommended Operating Parameters / Pin Functions Pin Name Function/Features Range J1, K1 POWER IN 1 J2, K2 POWER IN 2 J3, K3 POWER IN 3 C2, C3, D2, POWER COM D3 G2, G3, H2, H3 A1, B1, C1, D1, E1, E2, E3, F1, F2, F3, G1, H1 Outputs 1 4 and Logic Outputs 5-8 Outputs 9-12 Return for Power Supply or Signal Com 0 Volts (GND) Outputs Sourcing Discreet Output Default Mode On = +Supply Off = +Supply Off = +Supply 3,000mA 370µA, Supply = 28V DC 180µA, Supply = 13.6V DC LED Mode On = +Supply Off = 2.3V DC Off = 1.13V DC 3,000mA 342µA, Supply = 28V DC 166µA, Supply = 13.6V DC Notes: 1, Maximum continuous current allowed on any single connector Pin = 5 Amps 2, All limits are guaranteed by testing or statistical analysis 3, Z = >100KΩ 4, Z = 120Ω in Current Mode 5, Z = 32.4KΩ 6, Voltage references are with respect to GND (0V) unless otherwise specified. Rev: 2, Datasheet Page 4

8 Mounting 4.00 in 5.59 in Ø0.29 in 2 PLCS 30 PIN CINCH CONNECTOR 4.66 in Mount with 1/4" or 6mm Hardware 1.54 in Rev: 2, Datasheet Page 5