SIMADYN D Digital Control System. Fiber-Optic Rack Coupling CS12. User Manual. Edition DK No

Similar documents
SIMADYN D Digital Control System. Processor Module PM4. User Manual. Edition DK No

SIMADYN D Digital Control System. Expansion Module IT41. User Manual. Edition DK No

SIMADYN D Digital Control System. Subrack SR24.x. User Manual. Edition DK No

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

SIMADYN D Digital Control System. Interface module CS51. User Manual. Edition DK-Nr

Siemens Industrial s

SINAMICS. SINAMICS G120P dv/dt filter plus Voltage Peak Limiter. Safety information 1. General. Mechanical installation. Electrical installation 4

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

SIMADYN D Digital Control System. Processor module PM16. User Manual. Edition DK-Nr

SIMADYN D Digital Control System. Installation- and EMC Guidelines. User Manual. Edition DK No

Shutter Assembly Guide Frame Accessory

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

COM32. Installation & Operation Manual

Line filter SINAMICS. SINAMICS G130 Line filter. Safety information 1. General 2. Mechanical installation 3. Electrical installation 4

Siemens Spares. Preface 1. Scope of Delivery 2 SIPLUS CMS4000. Product Characteristics 3 ION PROFIBUS DP SPY T001 Installation and Maintenance 4

SIWAREX JB Aluminum Housing. Instruction Manual Edition 03/2006

SIMATIC. FM 356 Application Function Module, Installation and Startup. Preface, Contents. User Information. Product Overview

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

S7-300 Programmable Controller

B63/ NS MS. EtherNet/IP LINK

Operating Instructions (Compact) SIMATIC. Industrial PC SIMATIC Microbox PC 420. Siemens. Release 11/2006 A5E

BaseUnits (6ES7193-6BP.../3RK1908-0AP00 ) SIMATIC. ET 200SP BaseUnits. Preface. Guide to the documentation 1. Product overview 2

CMU 100 RS232 to Singlemode Fiber Optic Converter User Manual

CMU 100 Multimode Fiber Optic to Singlemode Fiber Optic Converter User Manual

SITOP power supply. Selectivity modules. Overview. Safety notes. Description, device design, dimension drawing. Mounting/removal 3

Converter SINAMICS G150. Type 6SL37102G

Product Information Mixed. Configuration ET 200SP / ET 200AL SIMATIC. ET 200SP Product Information Mixed Configuration ET 200SP / ET 200AL.

Use with 0 to 70 C ambient. temperature SIMATIC. Process Control System PCS 7 Use with 0 to 70 C ambient temperature. Preface 1. Product combination 2

DF PROFI II CPCI. Installation Instructions V Project No.: 5302 Doc-ID.: DF PROFI II CPCI KUNBUS

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

Description. SIMATIC Sensors. RF systems Wide-range power supply unit for SIMATIC RF systems. Operating Instructions 11/2007 J31069-D0169-U001-A4-7618

Type Quickstart (from device Version 2)

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02-0AA0) Preface. Properties 2. Diagnostics 3.

EMMS-T A00 SIERS. Siemens integrated electrical racking system instruction manual. usa.siemens.com/mvswitchgear

Operating instructions for AX5801. TwinSAFE drive option card for the AX5000 servo drive. Version: Date:

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5 A ST (6ES7132-4BD01-0AA0) Preface. Properties 1. Diagnostics 2.

DF PROFI II PCIe. Installation Instructions V Project No.: 5302 Doc-ID.: DF PROFI II PCIe KUNBUS

PNOZ m ES RS232. Configurable Control System PNOZmulti. Operating Manual EN-01

DF FA SE. SIPLUS RIC IEConS7. File Transfer Version V1.6

Device manual SINAMICS SINAMICS G120. Distributed inverter box Control cabinet for wall or floor mounting.

SINAMICS G130. Cabinet design and EMC. Operating Instructions 03/2013 SINAMICS

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

DI 8x24VDC ST digital input module SIMATIC. ET 200SP DI 8x24VDC ST digital input module (6ES7131-6BF00-0BA0) Preface. Documentation guide

Troubleshooting Manual

SCHOTT FLM 4 Fiber Lighting Modul. Operating Instructions

MICROMASTER 411 & COMBIMASTER 411 AS-i Module

Medium-Voltage Drive SINAMICS SM150. Type 6SL3845. Tests carried out on drives This documentation pertains to SM150 wassergekühlt G20 F03 F72 F79 F76

Manual Release 09/2002. cm-lon FOR LOGO! Communication with LOGO! with LON systems

A B

MDM 011-Z1 Regen Resistor

Dell OptiPlex All-in-One. Stand Installation Guide

iconverter 2-Module Power Chassis

SIMOVERT MASTERDRIVES

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

CPCI-PS24 24V-Power Supply

PRO-1250D CT MID DIN rail three phase four wire energy meter.

ET 200S distributed I/O Digital electronic module 2DO AC V (6ES7132-4FB01-0AB0)

Aotewell SIMATIC S7-PDIAG for S7-300 and S Configuring Process Diagnostic Getting St

Instruction manual. Output chokes 690V. Safety information 1. General 2. Mechanical installation 3. Electrical installation 4

Power module PM-E DC24V HF SIMATIC. ET 200S distributed I/O Power module PM-E DC24V HF (6ES7138-4CA60-0AB0) Preface. Properties.

High Precision Quad Output DC Power Supply

SIMATIC. Communications processor CP 340 first commissioning steps. Getting Started 04/2005 A5E

Manual Version: V1.00. Video Decoder Quick Guide

Installation manual plugs and connectors with screw connection (16/32 A)

crio PN Installation Instructions V0.2/ COMSOFT

SUN2000P-375 W Smart PV Optimizer. User Manual. Issue 01. Date HUAWEI TECHNOLOGIES CO., LTD.

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Siemens Drives & PLCs

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

SINAMICS Siemens Controlss

CMU 100 RS485 to Ethernet Converter User Manual CMU 100 / CMU 100 / 1.M.9 CMU 100 / 1.L.9 CMU 100 / CMU 100 / 7.M.9 CMU 100 / 7.L.

IV-30 Operating Manual for Pulse Distributor Cassette with potential separation

User Manual Gateway component for EtherNet/IP

Digital input module. DI 16x24VDC 8xM12 6ES7141-5AH00-0BA0) SIMATIC. ET 200AL Digital input module DI 16x24VDC 8xM12 6ES7141-5AH00-0BA0) Preface

SIMATIC S Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

Analog Monitor Installation Manual

C9900-P223 and C9900-P224

Digital ac/dc (24V) Input Module

INCOM communications adapter module

TELEPERM M. Signal Module (6DS1916-8RR) Manual. Version V 2.2

It's Here... Access Elevator Supply now offers Replacement Logic Boards for Siemens Class 72G Elevator Soft Starters. Easy to install and lightweight

BK MIKRO. Air Barrier Adapter. Assembly Instructions Issue 1.00 dated

Modicon Premium PLCs TSX CSY 84 / 85 / 164

TDM-150 TIMER DISPLAY

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10

SIMATIC. Component based Automation - WinLC PN Addendum to WinAC Basis V3.0. Foreword. Introduction to CBA and WinAC PN 2. Routing with WinLC PN 3

* * Agilent Power Distribution Unit (PDU) Installation Guide

Documentation KM2042. Sixteen channel digital output module with D-Sub Connector. Version: Date:

Team engineering via Inter Project. Engineering. TIA Portal. Team engineering via Inter Project Engineering. Basics of "Inter Project Engineering"

Analog Input Installation Manual

Power supply module PS 25W 24VDC (6ES7505-0KA00-0AB0) SIMATIC. S7-1500/ET 200MP Power supply module PS 25W 24VDC (6ES7505-0KA00-0AB0) Preface

Installation Job Aid for Ethernet Routing Switch 3600 Series

Documentation. KM2604 and KM2614. Four channel relay module. Version: Date:

EL1142 Series. IEC / IEEE 1613 Hardened 2-Port 10/100BASE-TX to 2-Port 100BASE-FX Media Converter. User s Guide

ST (6ES7132-6FD00-0BB1)

SMVector Additional I/O Module Installation and Operation Manual

Transcription:

SIMADYN D Digital Control System User Manual Fiber-Optic Rack Coupling CS12 Edition 05.95 DK No. 237741

User Manual, Fiber-Optic Rack Coupling CS12 Edition Status 1 Fiber-Optic Rack Coupling CS12 05.95 Copying of this document and giving it to others and the use or communication of the contents thereof is forbidden without express authority. Offenders are liable to the payment of damages. All rights are reserved in the event of the grant of a patent or the registration of a utility model or design. We have checked the contents of this Manual to ensure that they coincide with the described hardware and software. However, deviations cannot be completely ruled-out, so we cannot guarantee complete conformance. However, the information in this document is regularly checked and the necessary corrections included in subsequent editions. We are thankful for any recommendations or suggestions.

Inhalt Contents Warning information............1 1. Ordering information............3 2. Description............ 3 3. Board design............3 4. Interfaces............ 4 4.1. Backplane bus connection.........4 4.2. Parallel interface to the expansion board...... 4 4.3. Diagnostics interface......... 4 4.4. Fiber-optic cables......... 4 5. Application information............5 6. Additional components............5 7. Technical data............6 8. STRUC L mask of the CS12 board in the master program......6 9. Others............ 6 9.1. Attachments............6 9.1.1. Block diagram.........6 9.1.2. Dimension drawing.........6 10. ESD instructions............8 Siemens AG Dk No.. 237741 Edition 05.95

Warning information Edition 05.95 Siemens AG Dk No. 237741

Warning information N O T E! The information in this Manual does not purport to cover all details or variations in equipment, nor to provide for every possible contingency to be met in connection with installation, operation or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser s purposes, please contact your local Siemens office. Further, the contents of this Manual shall not become a part of or modify any prior or existing agreement, committment or relationship. The sales contract contains the entire obligation of Siemens. The warranty contained in the contract between the parties is the sole warranty of Siemens. Any statements contained herein do not create new warranties nor modify the existing warranty. Warning information W A R N I N G! Electrical equipment has components which are at dangerous voltage levels. If these instructions are not strictly adhered to, this can result in severe bodily injury and material damage. Only appropriately qualified personnel may work on this equipment or in its vicinity. This personnel must be completely knowledgeable about all the warnings and service measures according to this User Manual. The successful and safe operation of this equipment is dependent on proper handling, installation, operation and maintenance. Siemens AG Dk No. 237741 Edition 05.95 1

Warning information Definitions * QUALIFIED PERSONNEL For the purpose of this User Manual and product labels, a Qualified person is someone who is familiar with the installation, mounting, start-up and operation of the equipment and the hazards involved. He or she must have the following qualifications: 1. Trained and authorized to energize, de-energize, clear, ground and tag circuits and equipment in accordance with established safety procedures. 2. Trained in the proper care and use of protective equipment in accordance with established safety procedures. 3. Trained in rendering first aid. * DANGER For the purpose of this User Manual and product labels, Danger indicates death, severe personal injury and/or substantial property damage will result if proper precautions are not taken. * WARNING For the purpose of this User Manual and product labels, Warning indicates death, severe personal injury or property damage can result if proper precautions are not taken. * CAUTION For the purpose of this User Manual and product labels, Caution indicates that minor personal injury or material damage can result if proper precautions are not taken. * NOTE For the purpose of this User Manual, Note indicates information about the product or the respective part of the User Manual which is essential to highlight. C A U T I O N! This board contains components which can be destroyed by electrostatic discharge. Prior to touching any electronics board, your body must be electrically discharged. This can be simply done by touching a conductive, grounded object immediately beforehand (e.g. bare metal cabinet components, socket protective conductor contact). W A R N I N G! Hazardous voltages are present in this electrical equipment during operation. Non-observance of the safety instructions can result in severe personal injury or property damage. It is especially important that the warning information in all of the relevant Operating Instructions are strictly observed. 2 Edition 05.95 Siemens AG Dk No. 237741

Ordering information 1. Ordering information CS12: 6DD1660-0BA0 Fiber-optic rack coupling CS12 2. Description The CS12 communications board is the master board for the rack coupling via fiber-optic cable. A CS22 slave board can be directly inserted at the front panel through two fiber-optic cable connections. Data transfer between the processor boards and the CS12 memory is realized through the C bus. Thus, it can only be used in subracks with L- and C buses. The CS12 has a memory, which can be accessed by all partners. The maximum memory size is 128 kbyte. There is arbitration between the individual nodes so that only one coupling partner can access the memory at any one time. The ICS1 expansion board is inserted at connector X3. Up to four CS22 slave boards are connected to this board. The CS12 interface is disabled if an expansion board is inserted. The subrack with the CS12 can be considered as master in the system. The base sampling time and alarm interrupt are transferred to the connected slave boards via the CS12. Thus, the slave subrack can be synchronized. 3. Board design The board provides the following hardware components. Communications bus connection ( C bus, X1 ) Local bus connection ( L bus, X2 ) Connection for the ICS1 expansion board ( X3 ) Two fiber-optic cable connections to the slave board CS22 ( X5, X6 ) 128 kbyte memory It transfers the base sampling time and alarm interrupt from the C bus to the slave boards Diagnostics interface for the logic analyzer Siemens AG Dk No. 237741 Edition 05.95 3

Interfaces 4. Interfaces 4.1. Backplane bus connection The connection to the backplane buses of the subrack is established via the 96-pin plug connector at slots X1 and X2. The connection for the data-, address- and control bus as well as the +5 V power supply is realized through connector X1, and the power supply signals as well as the +5V and +15 V power supply, via connector X2. 4.2. Parallel interface to the expansion board The connection to the ICS1 expansion board is realized through the 96-pin socket connector strip X3. In addition to the data-, address- and control bus, the +5 V and +15 V power supplies are also realized through this connection. This interface is exclusively used to connect-up ICS1 and it is not permissible that it is used for other purposes. 4.3. Diagnostics interface When a fault occurs, a logic analyzer can be connected-up through the 50-pin plug connector X4, in order to simplify troubleshooting. This interface is exclusively used to connect-up the logic analyzer and it may not be used for any other purpose. 4.4. Fiber-optic cables The fiber-optic cables to the CS22 are inserted at the two plug connectors X5 and X6 on the front panel. Glass fiber-optic cables are used. They use glass fibers, fiber type 62.5/125 µm (core diameter/sheath diameter). ST plug connectors are used. The receiver for the signals from the CS22 is at connector X5, and the transmitter for the signals to CS22, at connector X6. One fiber-optic cable is inserted from X5 of the CS12 to X6 of CS22 and from X6 of CS12 to X5 of CS22. CS12 CS22 Fig. 1: Fiber-optic cable connection between CS12 and CS22 The fiber-optic cables can be ordered as pre-assembled cables from the Siemens Automation Group. For more detailed information regarding the ordering data, refer to Catalog SINEC Industrial Communication Networks, Catalog IK10 1993 The maximum cable length between the master- and slave board is 500 m. 4 Edition 05.95 Siemens AG Dk No. 237741

Application information 5. Application information Application information. The board can be used in pure 32-bit systems and in mixed 16-bit- and 32-bit systems and in pure 16- bit systems. Using a connector in the master program board mask, it is specified whether the memory is in the extended address range or in the special periphery range. The memory is pre-set in the extended address range. Memory range Memory size Entry at the EMA connector Extended address range 128 kbyte Y Special peripheral range 32 kbyte N When configuring the board, it should be observed that the entry at the CS12 EMA connector and the associated CS22 EMA connector are the same. If the entry is different, at start-up, a communications error will occur. This error is not identified when the master program is compiled. If a fiber-optic cable is not inserted, the transmit- and receive modules must be protected using caps. The board must be screwed tightly into the subrack to ensure perfect operation, even during start-up. If the board is inserted in an adapter, the front panel must be connected with the frame housing through a short cable. It is not permissible that the board is inserted or withdrawn under voltage. 6. Additional components Designation CS22 slave board Order No. 6DD1660-0BD0 Siemens AG Dk No. 237741 Edition 05.95 5

Technical data 7. Technical data INSULATION GROUP A acc. to VDE 0110, Para. 13, Group 2 at 24 V DC, 15 V DC, 5 V DC AMBIENT TEMPERATURE 0 to +55 degrees C, self-ventilated STORAGE TEMPERATURE -40 to + 70 degrees C HUMIDITY RATING F acc. to DIN 40040 ALTITUDE RATING S acc. to DIN 40040 MECHANICAL STRESSING Installed in stationary but not necessarily vibration-free equipment PACKAGING SYSTEM ES 902 C DIMENSIONS 220 * 233.4 mm BOARD WIDTH 1 slot in the subrack WEIGHT 0.5 kg CURRENT DRAIN P5 0.7 A P15 50 ma 8. STRUC L mask of the CS12 board in the master program 100 :CS12 "Fiber-optic rack coupling, CS12, C-bus" 101 EMA 1C = Y "Only P32 access permitted ( Y / N )" 102 ********************************************************************************* 9. Others 9.1. Attachments 9.1.1. Block diagram Block diagram Fig. 2 9.1.2. Dimension drawing Dimension drawing 3SE.465 660.9010.00 MB 6 Edition 05.95 Siemens AG Dk No. 237741

Others X1 C bus connector 96-pin ES902C X2 L bus connector 96-pin ES902C PS Addr. driver Data driver Contr. signals Backplane code Board code PS Reset Program Address Decoder Addr. driver Data driver Memory controller Chip select Memory Arbitration Addr. driver Data driver Memory controller X3 SV P S P S Interface to the ICS1 expansion board ES902C X5 X6 Fig. 2: Block diagram, CS12 Siemens AG Dk No. 237741 Edition 05.95 7

ESD instructions 10. ESD instructions Components which can be destroyed by electrostatic discharge (ESD) Generally, electronic boards should only be touched when absolutely necessary. The human body must be electrically discharged before touching an electronics board. This can be simply done by touching a conductive, grounded object directly beforehand (e.g. bare metal cubicle components, socket outlet protective conductor contact). Boards must not come into contact with highly-insulating materials - e.g. plastic foils, insulated desktops, articles of clothing manufactured from man-made fibers. Boards must only be placed on conductive surfaces. When soldering, the soldering iron tip must be grounded. Boards and components should only be stored and transported in conductive packaging (e.g. metalized plastic boxes, metal containers). If the packing material is not conductive, the boards must be wrapped with a conductive packing material, e.g. conductive foam rubber or household aluminum foil. The necessary ESD protective measures are clearly shown in the following diagram. a = Conductive floor surface b = ESD table c = ESD shoes d = ESD overall e = ESD chain f = Cabinet ground connection Seated Standing Standing / sitting 8 Edition 05.95 Siemens AG Dk No. 237741

ESD instructions Siemens AG Dk No. 237741 Edition 05.95 9

ESD instructions Drives and Standard Products Motors and Drive Systems Group Postfach 3269, D-91050 Erlangen System-Based Drive Technology 10 Edition 05.95 Siemens AG Dk No. 237741