VSW 2VGA A User Guide

Similar documents
This manual provides information on the Extron MDA 4V EQ video distribution amplifier and discusses how to install and operate them.

P/2 DA2xi User Guide. FCC Class A Notice. Specifications Availability. Features. Mounting the P/2 DA2xi. Attention:

HDP 101 4K User Guide

AXP 64 C AT Setup Guide

AXI 016 Setup Guide. Disconnect Power and Mount the AXI 016. Rear Panel Connections. C EXP Input Port and LED D EXP Thru Port and LED

AXI 22 AT D Setup Guide

AXP 64 C AT Setup Guide

OUTPUT SMD 202 AUDIO INPUT AUDIO. G 3.5 mm, 5-pole captive screw connector for analog stereo. audio output

AXP 50 C AT Setup Guide

USB Plus Matrix Controller Setup Guide

SOURCE 1 MIC PROGRAM RESET. ACP 100 Front Panel without PlasticFaceplate

EBP US Gang Button Panels Setup Guide

IPCP Pro 350DR, IPCP Pro 355DR Setup Guide

Headend Unit (HEU) Quick Installation Sheet

MLC Plus 84 D Setup Guide

100 - SERIES NETWORK SWITCHES QUICK START GUIDE

Now with Picture Memory

C D. ebus Button Panel EU and MK Series Setup Guide

ControlLogix Redundant Power Supply Chassis Adapter Module

MLC Plus 50/100/200 Series Setup Guide

TLP Pro 525M, 725M, and 1025M Series Setup Guide

300 - SERIES NETWORK SWITCHES QUICK START GUIDE

FX Supervisory Controller Wireless TEC Option Card Installation Instructions

LVN5200A-R2, rev. 1, Hardware Installation Guide

rcc.1081 Installation Instructions

Infosystem Remote Touchscreen Installation Instructions

Replacing the Quantum Ultra Disk Drives and System Board Computer Assembly

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

INSTRUCTION MANUAL DISTRIBUTION UNIT. Please read this manual thoroughly before use, and keep it handy for future reference.

Model DVS-2A 2-Port DVI Switch with Audio, Serial Control & Long Cable Equalization

Five-Band Remote Access Unit (RAU5x) Quick Installation Sheet

Installation Manual. Alpha 4000 RGB Signs. Before you begin

D-Link Switch User Manual. Table of Contents

INSTALLATION INSTRUCTIONS

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions

Specifications PVS 200, PVS 300, PVS 400 Systems

MTP AV Series MTP - TWISTED PAIR TRANSMITTERS & RECEIVERS FOR COMPOSITE VIDEO, S-VIDEO, AND AUDIO TWISTED PAIR

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

MCG Surge Protection

Remote I/O Scanner. Installation Instructions. (Catalog Number 1747-SN)

VI 021 S-DIAS VARAN Control Module

3-Phase, Dual-Input 6-Slot Power Supply System STARTUP GUIDE

Kramer Electronics, Ltd. USER MANUAL. Model: VS-1616A. 16x16 Balanced Stereo Audio Matrix Switcher

User guide. Bluetooth Keyboard BKB10

Specifications WallVault Systems

2 Mesa Ethernet Dock User s Manual

Rack Input Module Installation Instructions

ShoreTel IP Phone 655. Quick Install Guide & Warranty

Specifications WallVault IP Systems

IP Set-top Box (STB) Model No.: SP-110. Rev

ebus Button Panel Decorator-Style Series Setup Guide

2201 Rack Chassis User Manual

UHD-120 Owner s Manual 1 x 2 4K HDMI Distribution Amplifier

R SERIES INSTALLATION GUIDE

SPECIAL APPLICATION MANUAL PART NUMBER: TNP121UL. Tilt N Plug Jr. Table Top Interconnect Box USER'S GUIDE

MC 11 EB-2 Power supply cabinet with external bus, AC version

Network Camera. Quick Guide DC-S1283WRX. Powered by

Multi-Messager USB by Nel-Tech Labs, Inc. Installation & User Manual

Mini-DVI-WP Series WALL PLATE MINIATURE MULTIMODE FIBER OPTIC DVI TRANSMISSION SYSTEM

Instruction Manual Basic Rack PDU VP7541 and VP9571A

Specifications PVS 200D and PVS 400D Digital Systems

SEL-3421 Motor Relay HMI (With LCD) Quick-Start Guide

WaterStopper User Instruction Setup and Troubleshooting guide

Kramer Electronics, Ltd. USER MANUAL. Model: VM-4HDCP. 1:4 DVI Distributor

TE100-S16 16-Port 10/100Mbps Fast Ethernet Switch. User s Guide

Specifications VN-Matrix 250 Series

QUICK INSTALL GUIDE READ ME FIRST XWC Package Contents: XWC-1000 Wireless Controller. Rack Mount Kit. Power Cord. Wireless Controller

TP7 7 Touch Panel User Interface Quick Install Guide

HP R/T2200 UPS. Overview. Precautions. Installation Instructions. The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W.

Kramer Electronics, Ltd. USER MANUAL. Model: WP-101. XGA/Stereo Audio Line Driver

SignBOX II. Retrofit Guide for (X)WS201 and (X)WD201

User Manual 318BT. Phantom Powered Bluetooth Audio Receiver

Kramer Electronics, Ltd. USER MANUAL. Model: VP :8 XGA / Balanced Stereo Audio DA

NSD/M1 Installation Instructions

Messager USB w/ Night Answer

Kramer Electronics, Ltd. USER MANUAL. Model: WP-210E. XGA Line Driver

Installation Instructions RF5010 and RF5210

Kramer Electronics, Ltd. USER MANUAL. Model: VP-6A. 1:6 UXGA / Audio / +1 CAT5 Distributor

1 PORT HARDENED SERIAL SERVER

AgileMesh Node Configuration Guide

MTPX Plus Series MTP Twisted Pair Matrix Switchers with IP Link for RGBHV, Video, Audio, and RS-232

CWA BT320 Product Information Guide

AN-310-RT-4L2W. 310 SERIES MULTI-WAN GIGABIT VPN ROUTERS Quick Start Guide

FortiFone QuickStart Guide for FON-175

NCH-1000 (Multiple Breaker Types) Installation Instructions

User guide. Stereo Bluetooth Headset SBH60

Copyright. Warning. Warning! Communications & Safety Regulation Information

Kramer Electronics, Ltd. USER MANUAL. Model: VP-200XLN. XGA Line Amplifier / DA

Kramer Electronics, Ltd. USER MANUAL. Model: VS-162V. 16x16 Video Matrix Switcher

Specifications MLC 226 Series

TV O P E R A T I O N S M A N U A L

ENCELIUM EXTEND Manager Wiring and installation manual Light is OSRAM

Installation Instructions RF5010 and RF5210

Kramer Electronics, Ltd. USER MANUAL. Model: VP-200NAK. 1:2 XGA / Audio DA

Auto-Transfer Rack Power Distribution Unit

Intelligent Channel Bank Shelf

Product Manual. USB Charging Hub 10 Port Hi-Power 2.4A USB Charger Hub. Coolgear, Inc. Version 1.1 September 2017 Model Number: U2CHGRHUB10

Installing and Configuring Rialto Analytic Appliances

Bluetooth Sound Bar with Built-in Subwoofer Model: SB210

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents.

Transcription:

User Guide The Extron is a compact and economical two-input, one-output VGA switcher with unbalanced stereo audio and 300 MHz (-3 db) video bandwidth. It accepts two VGA-UXGA, RGBHV, RGBS, RGsB, RsGsBs, component video, or HDTV component video inputs. The switcher has two unbalanced stereo audio inputs and one unbalanced stereo audio output. It also features a buffered local monitor output for Input. A front panel toggle switch, a contact closure controller, or the autoswitching option can be used for input selection. This guide contains information about the Extron switcher. The terms and switcher are used interchangeably in this manual. The Extron interface, an optional accessory used when several switchers are daisy chained together, is also discussed. FCC Class A Notice This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 5 of the FCC rules. The Class A limits provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause interference. This interference must be corrected at the expense of the user. NOTES: This unit was tested with shielded I/O cables on the peripheral devices. Shielded cables must be used to ensure compliance with FCC emissions limits. For more information on safety guidelines, regulatory compliances, EMI/EMF compatibility, accessibility, and related topics, see the Extron Safety and Regulatory Compliance Guide on the Extron website. Specifications Product specifications are available on the Extron website, www.extron.com. Application Diagram Up to 0 switchers can be daisy chained together with each switcher input separately fed and controlled by an optional accessory interface, the. Figure is an example of how several such switcher-interface combinations can be daisy chained together in a boardroom environment. By default, all switchers are set to input as the active input. Therefore, in a daisy chain of switchers the VGA and audio signals flow from one switcher to input of the next switcher in the chain. The switchers are daisy chained in this fashion until the last switcher in the daisy chain outputs to a projector and audio amplifier. Up to ten switchers can be daisy chained together without any degradation in picture quality. One power supply powers up to five switchers. Extron Projector Extron VGA Switcher Extron Expandable, economical presentation chain for conference rooms and library study rooms. Projector Figure. Extron pre-made VGA with audio cable assemblies. Daisy Chaining the Multiple Switchers

User Guide (Continued) Features Inputs Video on female 5-pin HD connectors, audio on 3.5 mm stereo mini jacks puts Video on female 5-pin HD connectors, audio on 3.5 mm stereo mini jacks 300 MHz (-3 db) RGB video bandwidth Compatible with VGA-QXGA and HDTV component video signals Buffered loop-through for input one ID bits from inputs and are routed to the output Auto-input switching Automatically switches to the highest-numbered input with an active video signal. Contact closure remote control Front panel toggle switch for input selection Through-desk, under-desk, and projector-mountable U, quarter rack width metal enclosure External Extron Everlast power supply included Provides worldwide power compatibility with high demonstrated reliability and low power consumption Extron Everlast Power Supply is covered by a 7 year parts and labor warranty Installation Overview To install and set up the for operation, follow these steps:. Turn all of the equipment off. Make sure that the video and audio sources (computers, stereos, DVD players, or other devices), the, the output devices (projectors, speakers), and the contact closure control device are all turned off and disconnected from the power source.. If you are going to daisy chain two or more switchers with control panels, identify the revision of the board (for configuring the s) and configure the switcher jumpers (see Setting the Jumpers on page 4). 3. If desired, mount the switcher (see Mounting the on page 9). 4. Attach the cables (see Front Panel Features below and Rear Panel Features on the next page). 5. Connect power cords and turn on the devices in the following order: output devices, contact closure controller, switcher, and input devices. 6. Select an input using the front panel input toggle switch or the contact closure controller. 7. The image should now display, and sound should be audible. If not, ensure that all devices are plugged in and receiving power. Check the cabling and make adjustments as needed. Select a different input to check for a picture and sound. Front Panel Features A B INPUT INPUT C D E F G Figure. Front Panel Features A Input LED indicator This LED lights green whenever Input (video and audio) is selected. B Input LED indicator This LED lights green whenever Input (video and audio) is selected. NOTE: The LEDs also serve as power up indicators. When the switcher is powered up, the selected input LED lights. C Input select toggle switch Toggle this switch up to select Input. Toggle it down to select Input. D Input video Input VGA-UXGA, RGBHV, RGBS, RGsB, RsGsBs, component video, or HDTV component video through this female 5-pin VGA connector.

User Guide (Continued) E Input audio (see figure on the previous page) Input unbalanced stereo audio through this 3.5 mm mini audio jack (see figure 3). Tip (L) Ring (R) Sleeve ( ) 3.5 mm Stereo Plug Connector (unbalanced) Figure 3. Audio Input Connector F Input video Input VGA-UXGA, RGBHV, RGBS, RGsB, RsGsBs, component video, or HDTV component video through this female 5-pin VGA connector. G Input audio Input unbalanced stereo audio through this 3.5 mm mini audio jack (see figure 3). Rear Panel Features POWER V.A MAX VGA IN LOOP OUTPUT AUD OUT CONTACT AUTO-SW A B C D E Figure 4. Rear Panel Features A Power connector Connect the included VDC external power supply to the -pole 3.5 mm captive screw connector. NOTE: One power supply can power up to five switchers (see Power Connnection on page 5). B Loop Thru Input connector Female 5-pin HD VGA connector for buffered local monitor output from Input C put Female 5-pin HD VGA connector for output from Input or Input. The output video type follows input type and is either VGA-UXGA, RGBHV, RGBS, RGsB, RsGsBs, component video, or HDTV component video. D Audio put connector Unbalanced stereo audio is output from this 3.5 mm mini audio jack (see figure 5). Tip (L) Ring (R) Sleeve ( ) 3.5 mm Stereo Plug Connector (unbalanced) Figure 5. Audio output connector NOTE If you are daisy chaining, connect the other end of the audio cable to the Audio input connector on the downstream video switcher. E Contact closure/autoswitching (Contact/Auto-SW) Contact closure Connect a contact closure device to this 3.5 mm, 3-pole captive screw connector. Pin selects Input when momentarily connected to ground (pin 3). Pin selects Input when momentarily connected to ground (pin 3). Ground connects to the ground wire (equipment ground). CONTACT AUTO-SW NOTE: Simultaneously connecting both pins and to ground (pin 3) turns autoswitching mode on. 3

EXTRON 0-88-nn x ER:- yyyyyyyy yyyy User Guide (Continued) Autoswitching NOTES: Autoswitch mode must be disabled when daisy chaining switchers. If the autoswitch mode is enabled, the switchers cannot be daisy chained. RGsB and RsGsBs inputs and outputs occur in manual mode only. Autoswitching requires TTL level sync on pin 3 of the 5-pin HD connector. Pins,, and Ground when jumpered and shorted together (as shown at right) turn the autoswitching mode on. When the autoswitching mode is on, the switcher automatically switches to the input that has an active sync signal. If both inputs have an active sync signal present, input is selected, and the input LED indicator lights. If no active sync signal is present, the input LED indicator still lights to indicate that the unit is still powered on. CONTACT AUTO-SW NOTE: When autoswitch mode is active, both daisy chaining and the front panel input toggle switch are disabled, and the input cannot be manually switched. Any attempt to toggle the switch while the switcher is in this mode results in the flashing of the currently active input LED indicator. Contact closure is also disabled while in autoswitch mode. Setting the Jumpers NOTE: If you plan to use the and create a daisy chain configuration, you must configure the switchers before installing them in a rack or furniture and making connections. Daisy chaining switchers requires you to check, set or both internal jumpers in the switcher.. If applicable, disconnect all power to the switcher and any attached devices.. Remove the two screws on each side of the switcher (see figure 6). Remove the four connector nuts on the front panel of the switcher. Lift the top cover off of the switcher. JMP4 FRONT PANEL JMP3 JMP INPUT INPUT Remove (4) Screws Remove (4) Connector Nuts Figure 6. Removing the Cover 3. Set the jumpers for the switcher (see figure 7). 4. Set the cover in place and resinstall the screws removed in step. Figure 7. JMP5 JMP6 Jumper Locations There are five jumpers, numbered JMP, and JMP3 through JMP6, that control daisy chaining on the switcher (see figure 7). Both data and power must be daisy chained from one switcher to another. 4

User Guide (Continued) OPEN CLOSED All jumpers are set open (disabled) by default. Open or close the indicated jumpers in the table, as needed, to adjust the appropriate settings. Input Input put Pin 5 - Show Me JMP JMP 3 JMP 5 Pin 9 - Power JMP 4 JMP 6 Figure 8. Jumper Positions These jumpers enable or disable VGA connector pin 5 (control) and VGA connector pin 9 (power) of the switcher inputs and outputs. Close (install) the jumper for VGA connector pin 5 to daisy chain data to the next switcher. Close (install) the jumper for VGA connector pin 9 to daisy chain power to the next switcher (see Using the on page 6 and Daisy Chain Configuration on page 7). NOTE: When the switchers are not daisy chained together or used with the, all jumpers should be in the default (open) position. Power Connnection One power supply can power up to five daisy chained switchers. Additional switchers require one or more power supplies (see Daisy Chain Configuration on page 7). Figure 9 shows how to wire the power connector. CAUTION: The DC output cables must be kept separate from each other while the power supply is plugged in. Remove power before wiring. ATTENTION : Les câbles de sortie CC doivent être séparés les uns des autres tant que la source d alimentation est branchée. Coupez l alimentation avant d effectuer tout raccordement. ATTENTION: Do not connect power to the device until you have read the ATTENTION notifications on the next page. Ne branchez pas l alimentation à l appareil avant d avoir lu les mises en garde «ATTENTION» sur la page suivante. A A Smooth SECTION A A Ridges 3/6" (5 mm) Max. Power Supply put Cord Figure 9. Wiring the Power Connector ATTENTION: The length of the exposed wires in the stripping process is critical. The ideal length is 3/6 inches (5 mm). Any longer and the exposed wires may touch, causing a short circuit between them. Any shorter and the wires can be easily pulled out even if tightly fastened by the captive screws. La longueur des câbles exposés est primordiale lorsque l on entreprend de les dénuder. La longueur idéale est de 5 mm (3/6 inches). S ils sont trop longs, les câbles exposés pourraient se toucher et provoquer un court-circuit. S ils sont trop courts, ils peuvent être tirés facilement, même s ils sont correctement serrés par les borniers à vis. 5

User Guide (Continued) ATTENTION: Always use a power supply supplied by or specified by Extron. Use of an unauthorized power supply voids all regulatory compliance certification and may cause damage to the supply and the end product. Utilisez toujours une source d alimentation fournie ou recommandée par Extron. L utilisation d une source d alimentation non autorisée annule toute conformité réglementaire et peut endommager la source d alimentation ainsi que l unité. If not provided with a power supply, this product is intended to be supplied by a UL Listed power source marked Class or LPS rated VDC, 0.5 A minimum. Si le produit n est pas fourni avec une source d alimentation, il doit être alimenté par une source d alimentation certifiée UL de classe ou LPS avec une tension nominale de Vcc, 0.5 A minimum. Power supply voltage polarity is critical. Incorrect voltage polarity can damage the power supply and the unit. The ridges on the side of the cord identify the power cord negative lead (see figure 9 on the previous page). To verify the polarity before connection, plug in the power supply with no load and check the output with a voltmeter. La polarité de la source d alimentation est primordiale. Une polarité incorrecte pourrait endommager la source d alimentation et l unité. Les stries sur le côté du cordon permettent de repérer le pôle négatif du cordon d alimentation (voir figure 9 sur la page précédente). Pour vérifier la polarité avant la connexion, brancher l alimentation hors charge et mesurer sa sortie avec un voltmètre. To verify the polarity before connection, plug in the power supply with no load and check the output with a voltmeter. Pour vérifier la polarité avant la connexion, brancher l alimentation hors charge et mesurer sa sortie avec un voltmètre. Unless otherwise stated, the AC/DC adapters are not suitable for use in air handling spaces or in wall cavities. The power supply is to be located within the same vicinity as the Extron AV processing equipment in an ordinary location, Pollution Degree, secured to the equipment rack within the dedicated closet, podium, or desk. Sauf mention contraire, les adaptateurs CA/CC ne conviennent pas à une utilisation dans les espaces d aération ou dans les cavités murales. La source d alimentation doit être placée à proximité de l équipement Extron dans un emplacement ordinaire soumis à un degré de pollution de catégorie II, solidement fixé au rack d équipement d une baie technique, d un pupitre, ou d un bureau. The installation must always be in accordance with the applicable provisions of National Electrical Code ANSI/NFPA 70, article 75 and the Canadian Electrical Code part, section 6. The power supply shall not be permanently fixed to building structure or similar structure. Cette installation doit toujours être conforme aux dispositions applicables du Code américain de l électricité (National Electrical Code) ANSI/NFPA 70, article 75, et du Code canadien de l électricité, partie, section 6. La source d alimentation ne devra pas être fixée de façon permanente à une structure de bâtiment ou à une structure similaire. NOTE: Do not tin the stripped power supply leads before installing the captive screw connector. Tinned wires are not as secure in the captive screw connectors and could be pulled out. NOTE: The maximum number of switchers that can be daisy chained is limited by several factors: power consumption, cable lengths, and the overall distortion of the video and audio signals. Operation Apply power and the input signals. The video and audio output connectors, including the Loop Thru Input connector, should output signals. Input Selection There are three ways to select between Input and Input : Toggle the front panel input select switch up (Input ) or down (Input ). Use the rear panel contact closure capability. Press the Show Me button on the to select the input on the connected switcher. Using the The can be used on the inputs of a single switcher or on the inputs of multiple switchers in a daisy chain configuration. 6

INPUT INPUT User Guide (Continued) Setting the jumpers A jumper on the may need to be shifted from jumper J6 (the default position) to J5, depending on the application (see figure 0). J5 J6 Jumper installed J6 J5 Switcher compatibility (Input ) (Input ) Figure 0. Jumpers Single switcher example Figure shows an example of a single switcher configuration. Input Input V Power Supply Internal Jumper Settings Jumper Setting JMP JMP3 JMP4 JMP5 Open JMP6 Open Projector Figure. Single Switcher Configuration Press the Show Me button on the to select the corresponding input on the. Daisy Chain Configuration Multiple switchers can be daisy chained together in a loop configuration or a tree configuration. NOTE: Daisy chaining uses all pins and wires of a standard VGA cable. Not all VGA cables include all pins and wires. Ensure the VGA cable that you use has all 5 pins connected. Loop configuration In a loop configuration, the output of each is connected to Input of the next switcher. This repetition of one switcher output to another switcher input can be repeated for up to a maximum of 0 switchers in a daisy chain. The output of the first switcher is connected to a display. Source signals are connected to Input of each switcher either directly or through the interface. Select the source by toggling to Input on the front panel (or through contact closure on the rear panel) or by pressing the Show Me button for the corresponding switcher. Up to 0 switchers can be daisy chained in this configuration without any signal degradation. A power supply is required for every 5 switchers. Configure the jumpers on each according to the example in figure on the next page. The is configured for a loop configuration by default. 7

INPUT INPUT INPUT INPUT INPUT INPUT INPUT INPUT INPUT INPUT INPUT INPUT INPUT INPUT INPUT INPUT INPUT INPUT INPUT INPUT User Guide (Continued) NOTE: In a loop configuration, the Show Me feature can be used without a control panel. Select Input using either the front panel toggle switch (see figure, C on page ) or the rear panel contact closure control (see figure 4, E on page 3) to issue the Show Me control signal. Loop configuration example Figure shows an example of daisy chaining using a loop configuration. V Power Supply 9 8 7 6 V Power Supply Projector 5 4 3 Jumper Setting JMP JMP3 JMP4 Open JMP5 JMP6 Table 3 Figure. Loop Configuration Jumper Setting JMP JMP3 JMP4 JMP5 JMP6 Table Jumper Setting JMP JMP3 JMP4 JMP5 JMP6 Open Table Tree configuration In a tree configuration, the output of each switcher is connected to Input or Input of the next switcher. This repetition of one switcher output to another switcher input can be repeated for up to a maximum of 0 switchers in a daisy chain. The output of the last switcher is connected to a display. Source signals are connected to Input and Input of each switcher at the top of the tree through a interface. Select the source by pressing the Show Me button for the corresponding switcher. Switchers can be daisy chained in this configuration up to 0 levels deep without any signal degradation. A power supply is required for each switcher in the chain that has its output connected to Input of the next switcher. Sources can only be selected and connected to the switcher through the interface. Each must be configured for the tree configuration (see Using the on page 6 for additional information). 8

INPUT INPUT INPUT INPUT INPUT INPUT User Guide (Continued) Tree configuration example Figure 3 shows a simple example of daisy chaining using a tree configuration. 3 4 B Input Input V Power Supply* Input Input Input Input A B Internal Jumper Settings Jumper JMP JMP3 JMP4 JMP5 JMP6 A Setting Jumper JMP JMP3 JMP4 JMP5 JMP6 B NOTE: * Every switcher connected to Input of another switcher must have its own power supply. Setting Open Open V Power Supply Projector Figure 3. Tree Configuration Mounting the ATTENTION: Installation and service must be performed by authorized personnel only. ATTENTION : L installation et l entretien doivent être effectués uniquement par un électricien qualifié. NOTE: If you are going to daisy chain two or more switchers with control panels, identify the revision of the board (for configuring the s) and configure the switcher jumpers before mounting the switchers (see Setting the Jumpers on page 4). The can be mounted in a rack, or under or through furniture, using an optional mounting kit available at www.extron.com. When mounting the switcher, take cabling and power availability into consideration. Follow the appropriate mounting procedure on the following pages. Rack Shelf Mounting UL rack mounting guidelines The following Underwriters Laboratories (UL) guidelines pertain to the safe installation of the in a rack.. Elevated operating ambient temperature If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient temperature. Therefore, install the switcher in an environment compatible with the maximum ambient temperature (Tma = + F, +50 C) specified by Extron.. Reduced air flow Install the equipment in a rack so that the amount of air flow required for safe operation of the equipment is not compromised. 3. Mechanical loading Mount the equipment in the rack so that a hazardous condition is not achieved due to uneven mechanical loading. 4. Circuit overloading Connect the equipment to the supply circuit and consider the effect that circuit overloading might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern. 9

User Guide (Continued) 5. Reliable earthing (grounding) Maintain reliable grounding of rack-mounted equipment. Pay particular attention to supply connections other than direct connections to the branch circuit (e.g. use of power strips). Rack mounting instructions. If feet were installed on the bottom of the switcher, remove them.. Mount the on a rack shelf. On the standard rack shelf, the switcher mounts in one of four locations to the rear of the rack or in one of four locations to the front of the rack. 3. Attach the switcher to the rack shelf using two 4-40 x 3/6 inch machine screws. Insert the screws from the underside of the shelf and securely fasten them into diagonally opposite corners, as shown in figure 4. RSF 3 Rack Shelf /4 Rack Width Front False Faceplate Use mounting holes on opposite corners. () 4-40 x 3/6" Screws Figure 4. Mounting the on a Rack Shelf NOTE: Since the switcher is.0 inch high, there will be a gap of 0.75 inch above the switcher. 4. Attach the rack shelf to the rack using four 0-3 x 3/4 inch bolts (provided). Insert the bolts through #0 beveled washers, then through the holes in the rack ears and rack, as shown in figure 5. U Universal Rack Shelf Use mounting holes on opposite corners. () 4-40 x 3/6" Screws Figure 5. Mounting the on a Standard U Rack Shelf 0

User Guide (Continued) Under-desk mounting. Attach the under-desk mounting brackets to the with the four provided machine screws, as shown in figure 6.. Hold the switcher with attached brackets against the mounting surface. Use a soft pencil to mark the location of holes for screws on the desk or other furniture. 3. Drill /4 inch (6.4 mm) deep, 3/3 inch ( mm) diameter pilot holes in the table or desk at the marked screw locations from the underside/inside (concealed side) of the furniture, where the switcher will be located. 4. Attach the to the desk with the provided wood screws. Figure 6. Under-desk Mounting Bracket Through-desk mounting. Hold the front panel of the switcher against the furniture. Use a soft pencil to mark the rough-in opening on the desk. The opening,.5 inch x 4.45 inches (.8 cm x. cm) will be slightly larger than the switcher enclosure.. Cut out the material from the rough-in area with a jigsaw. Check the opening size by inserting the switcher part way through the hole. If needed, use a saw, file, or sandpaper to enlarge the hole. Smooth the edges of the hole with sandpaper. 3. Attach the through-desk mounting brackets to the with the four provided machine screws, as shown in figure 7. 4. Hold the switcher with attached brackets up against the underside of the desk or table. Use a soft pencil to mark the locations of the holes for the screws that will attach the brackets to the desk. 5. Drill /4 inch (6 mm) deep, 3/3 inch ( mm) diameter pilot holes in the desk or table at the marked screw locations. The holes should be drilled from the underside or inside (concealed side) of the furniture, where the switcher will be located. INPUT INPUT Figure 7. Through-desk Mounting 6. Attach the switcher to the desk or table with the provided wood screws, as shown in figure 7. 7. To adjust the height of the switcher within the desk, slightly loosen the screws that attach the brackets to the switcher, adjust the height by sliding the switcher up or down, and retighten the screws.

User Guide (Continued) 007-08 Extron Electronics All rights reserved. All trademarks mentioned are the property of their respective owners. www.extron.com 68--0 Rev. E 0 8