Installation Instructions for the ISSUE 3 RDS-DIN1 Series Single Channel Interface Module PK 80103

Similar documents
Push-Pull and E-Stop Switches. Datasheet

SS400 Series. Please refer to SS400 Series Order Guide on page 7 for details.

SMART Position Sensor, 100 and 180 Arc Configurations

MICRO SWITCH Snap-in Panel Mount Basic Switches. DM DP Series. Datasheet

the Interactive Catalog

With this sensor, Honeywell has utilized MR technology through the ASIC at a level never before accomplished.

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor

Rotary Switches. Datasheet

MICRO SWITCH Military-Grade Toggle Switches. TL Series. Datasheet

With this sensor, Honeywell has utilized MR technology through the ASIC at a level never before accomplished.

onlinecomponents.com

MICRO SWITCH Military-Grade Toggle Switches TL Series Issue 4. Datasheet FEATURES POTENTIAL APPLICATIONS DESCRIPTION DIFFERENTIATION PORTFOLIO

HC900 Remote Termination Panel (RTP) For Relay Outputs

Quick Start Guide for the Limitless WLS Series Single Switch Adapter

MICRO SWITCH Miniature Sealed Basic Switches. SE and XE Series. Datasheet

Torque Thrust Transducers Model Issue 1. Datasheet FEATURES POTENTIAL APPLICATIONS DESCRIPTION PORTFOLIO VALUE TO CUSTOMERS

ABS2EC01EB input interface module mm - solid state - 24 V DC

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

FF-ST2 Series. Type 2 Safety Light Curtains for Industrial Machine Safeguarding

Name No. of I/O points Model Safety inputs: 12, test outputs: 4

Technical Note Entering and Using Command Mode on the Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH- 6130/6131 Series

Powered Roller Controller for DeviceNet

Output Voltage* (nom.)(adjustable)

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs

DI561 Digital Input Module

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

Operating Instructions. Power Supply & Latching Relay For Switches Model: RL manual_rl-6000_1016

Output Voltage* (nom.)(adjustable)

Photoelectric Sensor

MICRO SWITCH Sealed Subminiature Basic Switches. ZW Series. Datasheet

Model SC500. Programmable Single-Channel Transducer Indicator/Conditioner DESCRIPTION FEATURES

G3S4-A 5 VDC 12 VDC 24 VDC 0.6 A at 75 to 264 VAC (See note 1.) G3S4-A1 5 VDC 12 VDC 24 VDC Yes G3SD-Z01P-PD 1 A at 3 to 26 VDC (See note 2.

MICRO SWITCH Commercial-Grade Toggle Switches. NT Series. Datasheet

Photoelectric Sensor

BusBlock Digital I/O Module for the Smart Distributed System

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

DC562, digital input/output module,

Long Sensing-distance Capacitive Separate Amplifier Proximity Sensor E2J-W10MA 1M E2J-W20MA 1M. E2J-JC4A Amplifier Unit

Miniature Inductive Prox TL-W

Model Number Structure

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

DI572 Digital Input Module

MHK5 SERIES PROFINET ABSOLUTE MULTI -TURN ENCODER

DC561, digital input/output module,

ABB 520BID01 Binary Input datasheet

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Quad Digital I/O Board for the Smart Distributed System

Contact protection relay

D12 Series DIN Rail High Power Fiber Optic Sensor

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

02/11/2015

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

Controllers, Indicators & Set Point Programmers

D11 Expert Series 5V dc Models

Communications & Networking

TU531, TU532 Terminal Unit

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

DX561 Digital Input/Output Module

TM7BDM16A expansion block - TM7 - IP67-16 DI/DO - 24V DC A - M12 connector

TF501, TF521 Terminal Bases

BusBlock Digital I/O Module for the Smart Distributed System

EIS-EXTEND-C-EU. Ethernet Coaxial Extender for 10/100 Networks. Extend Ethernet Coaxial Connections Up to 8530 Feet

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

Model Number Structure

Long-time range model (0.1 min to 10 h) 24 VAC; SPDT H3RN-1 H3RN-11 12, 24 VDC DPST-NO H3RN-2 H3RN-21

Aluminum Excellent Performance, with Aluminum Chip Immunity! The indicator is visible from any direction.

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information

E3Z-G. Photoelectric Sensor with Grooved Design and Easy Settings. Grooved-type Photoelectric Sensor with Built-in Amplifier. Ordering Information

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

U-GAGE Q45U Ultrasonic Sensors

EH-RIO IP67 Profibus-DP I/O modules

E2K-X4ME1 2M E2K-X4ME2 2M

USER MANUAL. WBI412F41 AC current transducer

NI REM Remote I/O Overview DATASHEET. Digital Output Module for Remote I/O

DF-G2 High Speed Expert Dual Display Small Object Counter

Safety Standards. Model Number:

BusBlock Digital I/O Module for the Smart Distributed System

OTB1C0DM9LP. Main , length of segment <= 185 m , length of segment <= 160 m. 3.4 kohm for I8...I kohm I0...I1 5.7 kohm I6...

Model Number Structure

TM3AI4 module TM3-4 analog inputs

060AAS19 B MDS. MDS Medical AC-DC Adapter 19Volt, 60Watt / MDS-060AAS19 B. Highlights & Features. Safety Standards. Model Number: General Description

Application Package Dimension Output Input Output Output Protection Option Code Code Power Voltage Quantity Voltage Type (W) (VAC) (VDC)

Thread length (overall length)

DF-G2 High Speed Expert Dual Display Small Object Counter

Model NPN output PNP output Standard. configuration

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

UniStream Uni-I/O Modules

P7TF-IS16/OS16/OS08. I/O classification I/O points Internal I/O common Rated voltage Model 12 VDC P7TF-IS16 DC12 24 VDC P7TF-IS16 DC24 For inputs

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

CompactBlock Guard I/O EtherNet/IP Safety Modules

Output configuration Contact form Operation indicator Cable length Model PNP open collector. 1 m D5F-2B10 (+ common) ON when operated

Analog output 520AOD01 Data sheet

E2EC. Subminiature Sensors with Long-distance Detection. Cable Amplifier Proximity Sensor. Ordering Information

Aluminum-detecting Proximity Sensor (Separate Amplifier Type)

MICRO SWITCH Compact Precision Limit Switches. 14CE Series. Datasheet

NEW. TURCK Inductive Sensors - Specialty DS20

Transcription:

Installation Instructions for the ISSUE 3 RDS-DIN1 Series Single Channel Interface Module PK 80103 PERSONAL INJURY DO NOT USE in applications where product failure could result in personal injury or death. DO NOT USE in fail-safe applications. Improper installation of this device can cause personal injury. STRICTLY FOLLOW the instructions below. Failure to comply with these instructions could result in death or serious injury. GENERAL INFORMATION The RDS-DIN1 Series Single Channel Interface Module is designed to be used with the 926FS30 Railwheel Proximity Sensor in stand alone applications. The Interface Module converts the 2-wire DC Normally Closed (NC) output of the Railwheel Proximity Sensor into a Normally Open (NO), open collector output to interface with other equipment. The Interface Module is available with either a NPN (current sinking) or a PNP (current sourcing) output. A 10 ms nominal time delay on the output signal is also available. INSTALLATION INSTRUCTIONS Step 1 - Mount Interface Module (see Figure 1): Place flanges located on the back of the Interface Module housing over the top flange of the 35 mm DIN rail. Snap securely in place. Step 2 - Wire Interface Module (See Figure 2): NOTICE The 926FS30 Railwheel Proximity Sensor is polarity neutral. Each sensor input connection accepts either a blue or a brown leadwire. The Interface Module provides two supply connections to facilitate installation of multiple Interface Modules (daisy chaining) from a common power supply. Separate terminal connections are supplied for load pull-up (NPN) or pull-down (PNP). Use of these terminals is optional. Connect one Railwheel Proximity Sensor to the input connections. Connect an 18 Vdc to 30 Vdc supply to the negative (-) and the positive (+) supply connections using up to12 AWG wire. Connect a load to the output connection. Step 3 - Test Interface Module (see Table 1): Apply 18 Vdc to 30 Vdc supply voltage. If the input connection has a Railwheel Proximity Sensor attached, and no target is present, the LED is OFF. Apply a target to the Railwheel Proximity Sensor. The LED will turn ON and the output state will change. Actuate the test pushbutton switch to simulate Railwheel Proximity Sensor actuation. The LED will turn ON and the output state will change. FIGURE 1: MOUNTING DIMENSIONS (for reference only) (mm/in) 74,93 (2.95) 22,60 (0.89) BLUE BROWN INPUT LOAD OUTPUT HONEYWELL NEG POS 3,81 (1.50) 97,03 (3.82) 88,26 (3.48) TABLE 1: LED STATUS Condition (Supply Voltage Applied) Railwheel Proximity Sensor attached to Interface Module - no target present Railwheel Proximity Sensor attached to Interface Module - target present Test pushbutton switch actuated No Railwheel Proximity Sensor attached to Interface Module LED Status OFF ON ON OFF Sensing and Control

FIGURE 2: DIAGRAM SENSOR INPUT BLUE NOT USED SENSOR INPUT BROWN INPUT LOAD OUTPUT OUTPUT RED LED SUPPLY ADDITIONAL SUPPLY HONEYWELL NEG POS TEST PUSHBUTTON SWITCH SUPPLY ADDITIONAL SUPPLY CIRCUIT DIAGRAM - NPN (CURRENT SINKING) Railwheel Sensor Inputs (blue or brown leadwires) Main Circuit 18 Vdc to 30 Vdc (+) Output Load 0 Vdc (-) CIRCUIT DIAGRAM - PNP (CURRENT SOURCING) Railwheel Sensor Inputs (blue or brown leadwires) 18 Vdc to 30 Vdc (+) Main Circuit Output Load 0 Vdc (-) 2 Honeywell Sensing and Control For application help: call 1-800-537-6945

SPECIFICATIONS Parameter Condition Electrical Supply Voltage 18 Vdc to 30 Vdc Output Type Open collector, normally open, NPN or PNP Saturation Voltage 6.5 V max. @ 20 ma Output Load Current Per Channel 20 ma max. Leakage Current 50 µa max. Power-up Delay Time 50 ms max. Radiated Immunity Amplitude Modulation Pulse Modulation EN 61000-4-3, 10 V/m ENV 50140, 80 MHz - 1000 MHz ENV 50140, 900 MHz ± 5 MHz Fast Transient Burst EN 61000-4-4, 1 KV Conducted Disturbance EN 61000-4-6, 10 KV Impulse Withstand Voltage IEC 255-5, 1000 V Response Time Delay, Typical 100 µs or 10 ms (depending on catalog listing) Environmental Operating Temperature Range -40 C to +70 C (-40 F to +158 F) Shock 6G, 11 ms half sine Vibration 3G/0.060 in amplitude, 10 to 500 Hz Sealing NEMA 1 Humidity 95% RH non-condensation Housing Material ABS (plastic) Protection Reverse polarity and short circuit INTERFACE MODULE IDENTIFICATION Catalog Listing Output Description RDS-DIN1-NA-D1 NPN (Current Sinking), Normally Open, 100 µs Nominal Time Delay RDS-DIN1-NA-D2 NPN (Current Sinking), Normally Open, 10 ms Nominal Time Delay RDS-DIN1-PA-D1 PNP (Current Sourcing), Normally Open, 100 µs Nominal Time Delay RDS-DIN1-PA-D2 PNP (Current Sourcing), Normally Open, 10 ms Nominal Time Delay For application help: call 1-800-537-6945 Honeywell Sensing and Control 3

WARRANTY/REMEDY Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Contact your local sales office for warranty information. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace without charge those items it finds defective. The foregoing is Buyer s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. For application assistance, current specifications, or name of the nearest Authorized Distributor, check the Honeywell web site or call: 1-800-537-6945 USA 1-800-737-3360 Canada 1-815-235-6847 International FAX 1-815-235-6545 USA INTERNET www.honeywell.com/sensing info.sc@honeywell.com Sensing and Control Honeywell Inc. 11 West Spring Street Freeport, Illinois 61032 Printed with Soy Ink on 50% Recycled Paper PK 80103-3-EN IL50 GLO 0303 Printed in USA www.honeywell.com/sensing

Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Honeywell: FSS020WNSR