USB RS485 High Isolated Industry Converter Box for DIN Rail - product #248

Similar documents
EX KVIS RS232/422/485 3-in-1 Serial to USB Adapter (w/ 4KV Isolation, 15KV ESD Surge Protection)

USB to RS-232/RS422/485. US-101-I USB To Serial Operation Manual

USB-COM Plus ISO (USB-COMi SI-M)

ADAM-4510 RS-422/RS-485 Repeater ADAM-4510S Isolated RS-422/485 Repeater ADAM-4520 Isolated RS-422/485 Converter Startup Manual

USB to RS-232/RS422/485. URK-228-I USB To Serial Operation Manual

PCI Express 4-Port Industrial Serial I/O Cards

USB to RS-422 / 485. US USB To Serial Operation Manual

Manual Industry Interfaces

Product Manual. USB to Optical Adapter Industrial Isolated RS- 232/422/485. Coolgear, Inc. Version 2.1 December 2018 Model Number: USB-COMi-Si-M

Product Manual. USB BAY-4 Port Serial DB- 9 RS-232 Adapter with FTDI Chipset. Coolgear, Inc. Version 1.1 September 2017 Model Number: USBG-BAY4

Windows 8 / 7 CONTENTS. USB to RS-422 Converter. Part Number: USB FEATURES. 2 SPECIFICATIONS. 2 CONNECTIONS.. 3

Moxa TCC-100 Series User s Guide

Windows 8 / 7 CONTENTS. USB to RS-485 Converter. Part Number: USB FEATURES. 2 SPECIFICATIONS. 2 CONNECTIONS.. 3

EasySYNC Ltd. USB to Serial Converters Manual

EasySYNC Ltd. USB to Serial Converters Manual

Moxa TCC-100 Series Hardware Installation Guide

MED102A. Industrial Serial to Single-mode Fiber Converter

Installation Guide of Hi-Speed USB to Industrial Single RS-422/485 Adapter

Manual Fiber Optic Interfaces

Future Technology Devices International Ltd. USB to RS422 Serial Converter Cable. Datasheet

RS-485 module. Data sheet. for electricity meters

ELAN DIGITAL SYSTEMS LTD. CF428 COMPACT FLASH CF+ CARD USER S GUIDE

8S RS232/422/485 Combo to USB2.0 Module Box Installation Guide

Commercial Grade USB to RS-422/485 Adapter User's Manual

Product Manual. 2 Port USB to RS-422 /485 Optical Isolated Adapter. Coolgear, Inc. Version 1.1 March 2018 Model Number: USB-2COMi-Si-M

3.1 I-7560 Pin Assignment and Specifications: Introduction

USB to RS-485/RS-422 Interface Converter. User Manual

Media Converters. Media Converters. Product Selection Guides

GT- IRDM-9603 Product description Rev. 2 17/06/2014

8 Port USB to RS- 232/422/485 Octal Adapter. Product Manual. Coolgear, Inc. Version 1.1 April 2018 Model Number: USB-8COMi-RM.

Korenix JetCard Series Multiport Serial Card/Ethernet Switch Card User s Manual

PCAN-Repeater DR CAN Repeater for the Decoupling of Bus Segments. User Manual. Document version ( )

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

Introduction & Specifications of Hi-Speed USB to Industrial Dual Ports RS-422/485 Adapter

OTB1C0DM9LP. Main , length of segment <= 185 m , length of segment <= 160 m. 3.4 kohm for I8...I kohm I0...I1 5.7 kohm I6...

ICF-1150 Series Quick Installation Guide

Product Manual. USB to RS232 TTL CMOS Adapter Cable with Terminal Block. Coolgear, Inc. Version 1.1 April 2018 Model Number: USB-232TTLMOS

W&T. Universal Fiber Optic Interface Converter W&T. Manual. Universal FO Interface Converter. Model Release 1.0. Subject to error and alteration

Installation Guide of Hi-Speed USB to Industrial I/O Adapter

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

MEV Limited USB232/485 INSTRUCTION MANUAL

TM258LF42DT compact base M I/O - 24 V DC - CANopen

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

USB-COMi-TB USB to Industrial Single RS-422 / 485 Adapter Manual. Specifications and Features

TM258LF42DT compact base M I/O - 24 V DC - CANopen

AQ_G24 GSM Terminal Card Motorola Cellular GSM Engine

MODEL USB-FLEXCOM4. USB to Four RS-232/422/485 Serial Ports and MODEL USB-COM232-4A USB to Four RS-232 Serial Ports USER MANUAL

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

Serial to RS422/485 Converter SER 485 PRO( SI) User Manual

This 4-port RS-422/485 Adapter is provided with an external switching power adapter in the package.

Serial Interface Modules TTL to RS232/RS485/RS422

EZ864 G. Telit Cellular GSM/UMTS Engine. Hardware guide Version: Update: 27. APR.2009 EZ864 G_Hardware Guide_V

ICF-1150 Series Quick Installation Guide

LMC058LF42 compact base - 42 I/O - 24 V DC supply

USB to RS232 Converter USB-013 (Rev3) User s Manual Ver. 1.2 HuMANDATA LTD.

Bluetooth to RS-232&RS422/485. EX-9132B/BI Bluetooth Adapter Operation Manual

W&T Manual Interface modules W&T

General Specifications. P2-SCM Serial Communications

TRP-C08M. USB To 4 RS232/422/485 Isolated Converter. User s Manual. Printed Jun Rev 1.0

Installation Guide of Hi-Speed USB-to-Optically Isolated RS-422/485 Adapter

icex-cmtm General specs and Installation guide

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

Product Manual. Mini USB to Terminal RS422 RS485 FTDI Plug-in Adapter. Coolgear, Inc. Version 1.1 April 2018 Model Number: USBG-422MiNi

CAN-Bridge. CAN Communications Module for CAN 2.0 A/B, CAN Layer AA01. Manual. Version 1/ from HW 1 & FW 1.00

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter

User s Manual Printed Sep Rev 1.2

OnCell G3100 Series Quick Installation Guide

Faults on the system Proximity switch connection technology:

4-Port Industrial USB to RS-232/422/485 Serial Adapter - 15 kv ESD Protection

Intelligent 4 Port RS-422/485 to 2 Port Ethernet Serial Device Server with PoE

Industrial Media Converters

USB-16COMi-M 16-Port RS-422/485 USB Serial Adapter User Manual. Features and Specifications. Power Supply

Introduction & Specifications of Hi-Speed USB to Serial Adapters

I-7560U/7561U/7563U. User Manual WARRANTY WARNING COPYRIGHT TRADEMARKS CONTACT US

Product Manual. Single Port RS-232 USB Serial Adapter Optical- ISO Surge Protection. Coolgear, Inc. Version 1.1 March 2018 Model Number: USB-COM-Si-M

8-Port Industrial USB to RS-232/422/485 Serial Adapter - 15 kv ESD Protection

USB485. USB to RS485 Converter Card. User Manual for connecting with Windows Vista Version 1.01

TM258LD42DT4L compact base M I/O - 24 V DC

Three-phase electricity meter with instantaneous reading of electrical variables. Input current measurement: 5 A, 90 A, 150 A, 250 A (span by model).

TM258LF42DT compact base M I/O - 24 V DC - CANopen

onlinecomponents.com

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

TM258LD42DT4L compact base M I/O - 24 V DC

Commercial-grade Interface Converter User Manual

Installation Guide of Hi-Speed USB to Octal RS-232/422/485 Adapter

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features

PCAN-Optoadapter Plug-on Adapter for Decoupling CAN Networks. User Manual. Document version ( )

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

EZ864 UMTS Terminal Telit Cellular GSM Engine

TRP-C08. USB to RS232/422/485 Isolated Converter. User s Manual. Printed Sep.2014 Rev 1.4

PCAN-Repeater 2-Channel CAN Repeater with galvanic isolation. User Manual V1.0.0

USB RS-485/422 Communication adapter virtual serial port ELO E211. Operation manual

VirtualSCADA VSU-485G USB to RS422/485 Isolated Converter User Manual

Signal Doublers. VariTrans A 20300

SCB-C08 USB to RS232/422/485 Converter

This data sheet is only valid in association with the IL SYS INST UM E user manual.

TRP-C08 User s Manual

USB485 USB to RS485 Converter Card

Transcription:

Our Products: USB High Speed - High Isolated - Industry Converter Interfaces Highest quality - on the basis of our experience - we not accept compromise! USB 2.0 - RS485 High Isolated Industry Converter Box for DIN Rail - product #248 USB 2.0 <=> RS485 High Isolated Industry Converter Box for DIN Rail (product no. #248) Notes: Extreme EMC-safe 8KV! Extreme tough! Designed for industry! 9 switchable terminating resistors! Dimension outside boiler (mm) L 90 x W 75 x B 23! Low current consumption! High-Speed Digital Isolator (no optocoupler)! Box for DIN Rail 35 x 7.5 mm installation! USB Modul: USB Specification 2.0 & 1.1 Automatic switching Ready-Transmit Max. 3 Mbps "data transfer rate" Aided "Remote wake-up" and power management Plug & Play installing Royal driver - FTDI Chipset RS485 Receiver: +/- 15 kv Human Body Model +/- 6 kv IEC 1000-4-2, Contact Discharge +/- 12 kv IEC 1000-4-2, Air-Gap Discharge Allow Up to 128 Receivers on the Bus True-Fail-Safe Receiver Thermal Protection Against Output Short Circuit RS485 Driver: +/- 9 kv Human Body Model Slev-Rate Limited for Errorless Data Transmission Current Limiting Thermal Shutdown for Driver-Overload Protection Galvanic Isolation: High common-mode transient immunity: >25 kv/µs Safety and regulatory approvals UL recognition: 5000 V rms for 1 minute per UL 1577 CSA Component Acceptance Notice #5A IEC 60950-1: 600 V rms (reinforced) IEC 60601-1: 250 V rms (reinforced) VDE certificate of conformity DIN V VDE V 0884-10 (VDE V 0884-10):2006-12 VIORM = 846 V peak EMC-safe: 8 KV Excellent References: Base stations of Cellular mobile telephony Welding robots production line With Ferrite - Shield Bead - 99,99 % reliability contra system crash Extras: Galvanically isolated +5V DC 120mA Output

Block diagram Converter images Technical characteristics Product: Driver: Installing: Chipset: USB 2.0 <=> RS485 High Isolated Industry Converter Box for DIN Rail DIN Rail 35 x 7.5 mm please see Drivers Plug & Play please see FAQs & Doks FTDI Cable length: 1,8 m (optional 0,5 1,5 2,5 5,0) or clamp-connection (please use only USB 2.0 cable! max. lenght 5,0m!) USB-Interface: Connection 1: Pin assignment 1: Virtual COM port (VCP) VCP drivers cause the USB device to appear as an additional COM port available to the PC. Application software can access the USB device in the same way as it would access a standard COM port. USB2.0 (1.1) - USB Female Mini Typ A 5 pol. USB Female - Mini Typ A 5 pol. Pin 1 - Vcc Pin 2 - D- Pin 3 - D+ Pin 4 - GND Pin 5 - GND #248 Optional connection: Clamp-connection (please use only USB 2.0 cable! max. lenght 5,0m!) Clamp A - USB shield Clamp B - USB +5V (red) Clamp D - USB Data+ (green) Clamp E - USB Data- (withe) Clamp F - USB GND (black) Please make assembled feed line (USB cable) shortly as possible!

Connection 2: Pin assignment 2: Terminating resistors: RS485 Clamp-connection Clamp G - TX- (Z) Converter Output Clamp H - TX+ (Y) Converter Output Clamp J - RX+ (A) Converter Input Clamp K - RX- (B) Converter Input Clamp L - GND Clamp M - Galvanically isolated +5V DC 120mA Output 9 switchable terminating resistors - to find on printed board If all DIP switch 1..9 OFF then: RX+/- Terminating resistor 100K RX+ Pull Up resistor 100K RX- Pull Down resistor 100K TX+/- Terminating resistor 100K TX+ Pull Up resistor 100K TX- Pull Down resistor 100K Optional shiftable Terminating and Pull Up/Down resistors: 1 DIL - RX+ Pull Up resistor 1K 2 DIL - RX Terminating resistor 120R 3 DIL - RX- Pull Down resistor 1K 4 DIL - TX+ Pull Up resistor 1K 5 DIL - TX Terminating resistor 120R 6 DIL - TX- Pull Down resistor 1K 7 DIL - TX+ Pull Up resistor 390R 8 DIL - TX Terminating resistor 220R 9 DIL - TX- Pull Down resistro 390R 10 DIL - Local Echo_OFF Halfduplex DIP 10 = ON / Fullduplex DIP 10 = OFF

Connection 2 guard: Handshake: TX/RX switching: Transmission lines: Galvanic Isolation: Galvanic Isolation Docs: EMC-safe: RS485 Receiver: +/- 15 kv Human Body Model +/- 6 kv IEC 1000-4-2, Contact Discharge +/- 12 kv IEC 1000-4-2, Air-Gap Discharge Allow Up to 128 Receivers on the Bus True-Fail-Safe Receiver Thermal Protection Against Output Short Circuit RS485 Driver: +/- 9 kv Human Body Model Slev-Rate Limited for Errorless Data Transmission Current Limiting Thermal Shutdown for Driver-Overload Protection no X-On / X-Off automatic 2-Wires Halfduplex or 4-Wires Fullduplex High common-mode transient immunity: >25 kv/µs Safety and regulatory approvals UL recognition: 5000 V rms for 1 minute per UL 1577 CSA Component Acceptance Notice #5A IEC 60950-1: 600 V rms (reinforced) IEC 60601-1: 250 V rms (reinforced) VDE certificate of conformity DIN V VDE V 0884-10 (VDE V 0884-10):2006-12 VIORM = 846 V peak DC/DC converter 6KV Quad-Channel Digital Isolators FAQ: Isolation, icoupler Technology, and icoupler Products 8 KV Data transfer rates: 183, 300, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 11520, 230400, 460800, 921600 bps. TTL 3,3V and 5V up to 3000000 bps. Supported transfer rates PDF file Status indication: Operating temperature: Available Drivers: Red LED - TXD activity Green LED - RXD activity Green LED - +5V 120mA Output activity -10..+70 C Windows Vista, Windows Vista x64 Windows XP, Windows XP x64 Windows 2000 Windows Server 2008, Windows Server 2008 x64 Windows Server 2003, Windows Server 2003 x64 Windows 98, Windows ME

Mac OS X (Intel), Mac OS X, Mac OS 9, Mac OS 8 Linux, Linux x86_64 Windows CE 6.0, CE 4.2-5.2, Windows Mobile 6 Windows Mobile 5, PocketPC 2003 ARM/XScale Processor & x86 Processor Windows CE 6.0 and CE 4.2-5.2 (Other Processors) - email support Installing the USB-RS485 converter The USB to RS485 converter is shipped with a Windows driver disk. When the converter is connected to the Windows based host computer, Windows will display the "Found New Hardware" screen and will prompt the user for a driver for the device. With the driver disk installed in drive "A", select the "Have Disk" option and browse the driver disk to the appropriate driver. Once installed, the USB converter will be assigned the next available COM port on the host computer. To verify the proper set-up, open the "System" icon in the "Control Panel" and click on the "Device Manager" tab. Under "Ports", there should now be a new COM port labeled "USB Serial Port". RS485 Info EIA-485 only specifies electrical characteristics of the driver and the receiver. It does not specify or recommend any data protocol. EIA-485 enables the configuration of inexpensive local networks and multidrop communications links. It offers high data transmission speeds (35 Mbit/s up to 10 m and 100 kbit/s at 1200 m). Since it uses a differential balanced line over twisted pair (like EIA-422), it can span relatively large distances (up to 4000 feet or just over 1200 metres). In contrast to EIA-422, which has a single driver circuit which cannot be switched off, EIA-485 drivers need to be put in transmit mode explicitly by asserting a signal to the driver. This allows EIA-485 to implement linear topologies using only two wires. The equipment located along a set of EIA-485 wires are interchangeably called nodes, stations

and devices. The recommended arrangement of the wires is as a connected series of point-to-point (multidropped) nodes, a line or bus, not a star, ring, or multiply-connected network. Ideally, the two ends of the cable will have a termination resistor connected across the two wires. Without termination resistors, reflections of fast driver edges can cause multiple data edges that can cause data corruption. Termination resistors also reduce electrical noise sensitivity due to the lower impedance, and bias resistors are required. The value of each termination resistor should be equal to the cable impedance (typically, 120 ohms for twisted pairs). RS422 and RS485 Standards RS422 RS485 Mode of operation Differential Differential Allowed no. of Tx and Rx 1 Tx, 10 Rx 32 Tx 32 Rx Maximum cable length 4000ft length 4000ft length Maximum data rate 10 Mbsp 10 Mbps Minimum driver output range ±2V ±1,5V Maximum driver output range ±5V ±5V Maximum driver short-circuit current 150 ma 250 ma Tx load impedance 100 Ohm 54 Ohm Rx input sensitivity ±200 mv ±200 mv Maximum Rx input resistance 4 kohm 12 kohm Rx input voltage range ±7V -7V to +12V Rx logic high >200 mv >200mV Rx logic low <200mV <200mV Cable lenght (m) = 100.000.000 / Baud (bps) Baud (kbps) Lenght (m) Baud (Mbps) 9600 19,2 38,4 115,2 250 500 750 10417 5208 2602 868 400 200 133 1 2 3 10 Lenght (m) 100 50 33 10 More Infos - Wiki - RS485

USB Converter 22549 Hamburg Germany T +0049 40 4840 9080 F +0049 40 4840 9081 Open 24/7 365-8:00-20:00 GTM Berlin copyright 2009 USB Converter last update 18.05.2009