TM241CE24U controller M IO transistor NPN Ethernet

Similar documents
TM241CE24T controller M IO transistor PNP Ethernet

TM241CE40R controller M IO relay Ethernet

TM241CE40T controller M IO transistor PNP Ethernet

TM241CE40R controller M IO relay Ethernet

TM241C40U controller M IO transistor NPN

TM241C24T controller M IO transistor PNP

TM241CE24T controller M IO transistor PNP Ethernet

TM241CE24T controller M IO transistor PNP Ethernet

TM241C40R controller M IO relay

TM241CE40R controller M IO relay Ethernet

TM241CE40R controller M IO relay Ethernet

TM241CEC24R controller M IO relay Ethernet CAN master

TM241CEC24T. Main. 14 (remote I/O architecture) W with max number of I/O expansion module ma fast input. 2.

TM251MESC controller M251 Ethernet CAN

TM251MESE. Main. [Us] rated supply voltage. 14 with remote I/O architecture W with max number of I/O expansion module

TM241C24R. Main. Discrete output type. Discrete output number. 14 (remote I/O architecture) 50 µs turn-on operation with I0...I13 terminal(s) input

TM221ME16T controller M IO transistor PNP Ethernet

TM221M32TK controller M IO transistor PNP

TM221CE24T controller M IO transistor PNP Ethernet

TM221M16TG controller M IO transistor PNP spring

TM251MESC controller M251 Ethernet CAN

TM221CE40R controller M IO relay Ethernet

TM221CE40T controller M IO transistor PNP Ethernet

TM200CE24T controller M IO transistor Source+ Ethernet

TM221ME32TK controller M IO transistor PNP Ethernet

TM221ME16T controller M IO transistor PNP Ethernet

TM200C24R controller M IO relay

TM221CE24R controller M IO relay Ethernet

TM221M16R controller M IO relay

TM221CE40R controller M IO relay Ethernet

TM221CE24T. Main. Discrete output logic. Discrete input current. <= 7 relay output

TM221ME16RG. Main. Discrete output number. Discrete input current

TM3DI16 module TM3-16 inputs

TM3AI4 module TM3-4 analog inputs

TM221C40R controller M IO relay

TM3TI4 module TM3-4 inputs temperature

TM3TI8T module TM3-8 inputs temperature

TM3TM3 module TM3-2 temperature inputs and 1 analog output

TM258LF42DT compact base M I/O - 24 V DC - CANopen

LMC058LF42 compact base - 42 I/O - 24 V DC supply

TM3DI16G module TM3-16 inputs spring

TM3DM8R module TM3-8 IO relays

TM258LD42DT4L compact base M I/O - 24 V DC

TM3DI8A module TM3-8 inputs 120V AC

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

TM3TI4 module TM3-4 inputs temperature

TM221ME16TG controller M IO transistor PNP Ethernet spring

TM258LF42DT compact base M I/O - 24 V DC - CANopen

TM258LF42DT compact base M I/O - 24 V DC - CANopen

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

TM221CE40T controller M IO transistor PNP Ethernet

HMISCU6A5 3 5 color touch controller panel - Dig 16 inputs/10 outputs

HMISCU8A5 5 7 color touch controller panel - Dig 16 inputs/10 outputs

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

TM221CE16T controller M IO transistor PNP Ethernet

HMISCU6B5 3 5 color touch controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

TM221M16R controller M IO relay

TM258LD42DT4L compact base M I/O - 24 V DC

TM238LFAC24DR compact base M I/O V AC supply - CANOpen- internal RAM 1000 kb

TM238LDD24DT compact base M I/O - 24 V DC supply -

LMC058LF42 compact base - 42 I/O - 24 V DC supply

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

TM238LFDC24DT compact base M I/O - 24 V DC supply - CANOpen - internal RAM 1000 kb

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

TM3SAC5RG SAFETY MODULE FOR PLC TM2xx, 1 FUNCTION, CAT3, SPRING TERMINALS

TM238LFDC24DT. Main. Discrete output voltage. Discrete input voltage type. Number of I/O expansion module 7 [Us] rated supply voltage

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

HMISCU6B5. Main. 60 right 40 top 60 bottom

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term

TM221C16T controller M IO transistor PNP

BMKC Controller for Parabolic Trough application without encoder, 8 In 8 Out 4 AI

HMISCU6A5. Main. 60 right 40 top 60 bottom

TM3SAF. Main. Device short name

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

OTB1C0DM9LP. Main , length of segment <= 185 m , length of segment <= 160 m. 3.4 kohm for I8...I kohm I0...I1 5.7 kohm I6...

TM221CE16R controller M IO relay Ethernet

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

BMKC Controller for Parabolic Trough, 8 DI 12 DO 4 AI

TWDLCAE40DRF compact PLC base Twido V AC supply - 24 I 24 V DC - 16 O

TWDLCDE40DRF compact PLC base Twido - 24 V DC supply - 24 I 24 V DC - 16 O

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

LXM28AU07M3X motion servo drive - Lexium 28 - single and three phase V W

RE22R2KMR Off-delay Timing Relay s 10min V AC/DC - 2C/O

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

XPSMCMDI Input expansion module with screw term

HMIGK5310 Keypad-touchscreen panel color x 480 pixels VGA -10.4" - TFT LCD

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

TWDLMDA20DTK extendable PLC base Twido 24 V - 12 I 24 V DC - 8 O solid state

TM3SAK. Main. Device short name

HMISCU8B5 5 7 color touch controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

RE22R2CMR Off-delay Timing Relay s 300h V AC/DC - 2C/O

XPSMCMDO Digital output pairs expansion modules with screw term

SD328AU68S2 motion control stepper motor drive - SD328 - <= 6.8 A

Transcription:

Characteristics controller M241 24 IO transistor NPN Ethernet Main Range of product Product or component type [Us] rated supply voltage Mar 09, 2017 Modicon M241 Logic controller 24 V DC Discrete input number 14 discrete input including 8 fast input conforming to IEC 61131-2 Type 1 Discrete output type Discrete output number Discrete output voltage Discrete output current Complementary Discrete I/O number 24 Number of I/O expansion module Supply voltage limits Inrush current Power consumption in W Discrete input logic Discrete input voltage Discrete input voltage type Voltage state1 guaranteed Current state 1 guaranteed Voltage state 0 guaranteed Current state 0 guaranteed Discrete input current Input impedance Transistor 10 transistor including 4 fast output 24 V DC for transistor output 0.5 A with Q0...Q9 terminal(s) for transistor output 0.1 A with Q0...Q3 terminal(s) for fast output (PTO mode) 7 (local I/O architecture) 14 (remote I/O architecture) 20.4...28.8 V <= 50 A 32.6...40.4 W with max number of I/O expansion module Sink or source 24 V DC >= 15 V for input >= 2.5 ma for input >= 5 ma for fast input <= 5 V for input <= 1 ma for input <= 1.5 ma for fast input 5 ma for input 10.7 ma for fast input 4.7 kohm for input 2.81 kohm for fast input 1 Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications

Response time Configurable filtering time Discrete output logic Output voltage limits Current per output common Output frequency Accuracy Leakage current Voltage drop Tungsten load Protection type Reset time Memory capacity Data backed up Data storage equipment Battery type 50 µs turn-on operation with I0...I13 terminal(s) for input 50 µs turn-off operation with I0...I13 terminal(s) for input <= 2 µs turn-on operation with I0...I7 terminal(s) for fast input <= 2 µs turn-off operation with I0...I7 terminal(s) for fast input <= 34 µs turn-on operation with Q0...Q9 terminal(s) for output <= 250 µs turn-off operation with Q0...Q9 terminal(s) for output <= 2 µs turn-on operation with Q0...Q3 terminal(s) for fast output <= 2 µs turn-off operation with Q0...Q3 terminal(s) for fast output 1 µs for fast input 12 ms for fast input 0 ms for input 1 ms for input 4 ms for input 12 ms for input Negative logic (sink) 30 V DC 2 A with Q0...Q3 terminal for fast output 2 A with Q4...Q7 terminal for output 1 A with Q8...Q9 terminal for output <= 20 khz for fast output (PWM mode) <= 100 khz for fast output (PLS mode) <= 1 khz for output +/- 0.1 % at 20...100 Hz for fast output +/- 1 % at 100 Hz...1 khz for fast output <= 5 µa for output <= 1 V <= 2.4 W Short-circuit and overload protection with automatic reset Reverse polarity protection for fast output Short-circuit protection 10 ms automatic reset output 12 s automatic reset fast output 8 MB for program 64 MB for system memory RAM 128 MB built-in flash memory for backup of user programs <= 32 GB SD card optional Backup time 2 years at 25 C Execution time for 1 KInstruction Application structure Realtime clock BR2032 lithium non-rechargeable, battery life: 4 yr 0.3 ms for event and periodic task 0.7 ms for other instruction 4 cyclic master tasks 8 event tasks 8 external event tasks 3 cyclic master tasks + 1 freewheeling task With Clock drift <= 60 s/month at 25 C Positioning functions Counting input number Control signal type PWM/PTO function 4 channel(s) (positioning frequency: 100 khz) 4 fast input (HSC mode) A/B signal at 100 khz for fast input (HSC mode) Pulse/Direction signal at 200 khz for fast input (HSC mode) Single phase signal at 200 khz for fast input (HSC mode) Integrated connection type USB port with connector mini B USB 2.0 Ethernet with connector RJ45 Non isolated serial link "serial 1" with connector RJ45 and interface RS232/RS485 Non isolated serial link "serial 2" with connector removable screw terminal block and interface RS485 Supply Transmission rate Communication port protocol Port Ethernet Communication service Serial link supply "serial 1" at 5 V, 200 ma 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m - communication protocol: RS485 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m - communication protocol: RS232 480 Mbit/s for bus length of 3 m - communication protocol: USB 10/100 Mbit/s - communication protocol: Ethernet Modbus non isolated serial link with master/slave method 1-10BASE-T/100BASE-TX port with copper cable support FDR 2

Local signalling Electrical connection Cable length Insulation Marking Downloading IEC VAR ACCESS Monitoring NGVL Programming Updating firmware SMS notifications DHCP server (via TM4 Ethernet switch network module) DHCP client (embedded Ethernet port) SNMP client/server FTP client/server SQL client Send email from the controller based on TCP/UDP library Modbus TCP client I/O scanner Ethernet/IP originator I/O scanner (embedded Ethernet port) Ethernet/IP target, Modbus TCP server and Modbus TCP slave 1 LED green for SD card access (SD) 1 LED red for BAT 1 LED green for SL1 1 LED green for SL2 1 LED per channel green for I/O state 1 LED red for I/O error (I/O) 1 LED red for bus fault on TM4 (TM4) 1 LED green for Ethernet port activity 1 LED red for module error (ERR) 1 LED green for PWR 1 LED green for RUN Removable screw terminal block for inputs and outputs (pitch 5.08 mm) Removable screw terminal block for connecting the 24 V DC power supply (pitch 5.08 mm) <= 50 m unshielded cable for input <= 10 m shielded cable for fast input <= 3 m shielded cable for fast output <= 50 m unshielded cable for output 500 V AC between fast input and internal logic Non-insulated between inputs 500 V AC between output and internal logic 500 V AC between fast output and internal logic Non-insulated between outputs 500 V AC between input and internal logic 500 V AC between output groups 500 V AC between supply and internal logic Non-insulated between supply and ground CE Surge withstand 1 kv for power lines (DC) in common mode conforming to EN/IEC 61000-4-5 1 kv for shielded cable in common mode conforming to EN/IEC 61000-4-5 0.5 kv for power lines (DC) in differential mode conforming to EN/IEC 61000-4-5 1 kv for relay output in differential mode conforming to EN/IEC 61000-4-5 1 kv for input in common mode conforming to EN/IEC 61000-4-5 1 kv for transistor output in common mode conforming to EN/IEC 61000-4-5 Web services Maximum number of connections Number of slave Cycle time Web server 8 connection(s) for Modbus server 8 connection(s) for SoMachine protocol 10 connection(s) for web server 4 connection(s) for FTP server 16 connection(s) for Ethernet/IP target 8 connection(s) for Modbus client 16 Ethernet/IP 64 Modbus TCP 10 ms 16 Ethernet/IP 64 ms 64 Modbus TCP Mounting support Top hat type TH35-15 rail conforming to IEC 60715 Top hat type TH35-7.5 rail conforming to IEC 60715 Plate or panel with fixing kit Height Depth Width Product weight 90 mm 95 mm 150 mm 0.53 kg 3

Environment Standards CSA C22.2 No 142 ANSI/ISA 12-12-01 UL 1604 CSA C22.2 No 213 EN/IEC 61131-2 : 2007 Marine specification (LR, ABS, DNV, GL) UL 508 Product certifications IACS E10 RCM CSA culus Resistance to electrostatic discharge 4 kv on contact conforming to EN/IEC 61000-4-2 8 kv in air conforming to EN/IEC 61000-4-2 Resistance to electromagnetic fields 10 V/m (80 MHz...1 GHz) conforming to EN/IEC 61000-4-3 3 V/m (1.4 GHz...2 GHz) conforming to EN/IEC 61000-4-3 1 V/m (2 GHz...3 GHz) conforming to EN/IEC 61000-4-3 Resistance to fast transients 2 kv for power lines conforming to EN/IEC 61000-4-4 1 kv for Ethernet line conforming to EN/IEC 61000-4-4 1 kv for serial link conforming to EN/IEC 61000-4-4 1 kv for input conforming to EN/IEC 61000-4-4 1 kv for transistor output conforming to EN/IEC 61000-4-4 Resistance to conducted disturbances, induced by radio frequency fields Electromagnetic emission Immunity to microbreaks Ambient air temperature for operation 10 V (0.15...80 MHz) conforming to EN/IEC 61000-4-6 3 V (0.1...80 MHz) conforming to Marine specification (LR, ABS, DNV, GL) 10 V (spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz)) conforming to Marine specification (LR, ABS, DNV, GL) Conducted emissions, test level: 120...69 dbµv/m QP, condition of test: power lines (radio frequency: 10...150 khz) conforming to EN/IEC 55011 Conducted emissions, test level: 79...63 dbμv/m QP, condition of test: power lines (radio frequency: 150 khz...1.5 MHz) conforming to EN/IEC 55011 Conducted emissions, test level: 63 dbμv/m QP, condition of test: power lines (radio frequency: 1.5...30 MHz) conforming to EN/IEC 55011 Radiated emissions, test level: 40 dbμv/m QP with class A (radio frequency: 30...230 MHz) conforming to EN/IEC 55011 Radiated emissions, test level: 47 dbμv/m QP with class A (radio frequency: 230 MHz...1 GHz) conforming to EN/IEC 55011 10 ms Ambient air temperature for storage -25...70 C Relative humidity IP degree of protection Pollution degree 2 Operating altitude Storage altitude Vibration resistance Shock resistance -10...55 C for horizontal installation -10...50 C for vertical installation 10...95 % without condensation in operation 10...95 % without condensation in storage IP20 with protective cover in place 0...2000 m 0...3000 m 3.5 mm (vibration frequency: 5...8.4 Hz) on symmetrical rail 3 gn (vibration frequency: 8.4...150 Hz) on symmetrical rail 3.5 mm (vibration frequency: 5...8.4 Hz) on panel mounting 3 gn (vibration frequency: 8.4...150 Hz) on panel mounting 15 gn for 11 ms Offer Sustainability Sustainable offer status RoHS (date code: YYWW) REACh Product environmental profile Product end of life instructions Green Premium product Compliant - since 1330 - Schneider Electric declaration of conformity Schneider Electric declaration of conformity Reference not containing SVHC above the threshold Reference not containing SVHC above the threshold Available Product environmental Available 4

End of life manual 5

Dimensions Drawings Dimensions 6

Mounting and Clearance Clearance 7

Mounting and Clearance Mounting Position Acceptable Mounting NOTE: Expansion modules must be mounted above the logic controller. Incorrect Mounting 8

Mounting and Clearance Direct Mounting On a Panel Surface Mounting Hole Layout 9

Connections and Schema Digital Inputs Wiring Diagram (*) : Type T fuse (1) : The COM0, COM1 and COM2 terminals are not connected internally (A) : Sink wiring (positive logic) (B) : Source wiring (negative logic) Fast Input Wiring (I0...I7) 10

Connections and Schema Fast Transistor Outputs Wiring Diagram (*) : Type T fuse (1) The V0+, V1+, V2+ and V3+ terminals are not connected internally. (2) The V0-, V1-, V2- and V3- terminals are not connected internally. 11

Connections and Schema Transistor Outputs Wiring Diagram (*) : Type T fuse (1) : The V1+ and V2+ terminals are not connected internally. (2) : The V1 and V2 terminals are not connected internally. 12

Connections and Schema USB Mini-B Connection 13

Connections and Schema Ethernet Connection to a PC 14