QUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control

Similar documents
QUICK START GUIDE. 2.4 Inch Finger Vein Terminal Time Attendance & Access Control

INSTALLATION GUIDE 2.4 Inch TFT Terminal Time Attendance & Access Control

Quick Start Guide. ProBio & ProFAC + ZKBioSecurity 3.0

Safety Precautions How to place the finger Product Contents Product PIN Diagram Product Dimensions Cables and Connectors Installation of Back Plate

Finger Vein Access Control device Quick Start Guide Version: 1.0 Date: June USB slot. USB slot

INSTALLATION GUIDE. InBio Pro Series Access Control Panels. Date: June, 2016 Version: 1.3

GENERAL QUICK START GUIDE

Installation Guide (ver 1.0)

Contents Safety precautions Product components Optional accessories Names of each parts Product Dimension Cables and Connectors Power Connection

Zodiac FR100 TM INSTALLATION MANUAL

USER MANUAL. BioPro SA50 Fingerprint & Palm Terminal. Version: 1.0 Date: August Inch TFT Terminal User Manual 1

SF200. Installation Guide & Quick Start Guide. 2 TFT AC Terminal Version: 1.0 Date: June 2014

W Series. Color Screen Fingerprint & Card Time Attendance and Access Control W 1 W 2

C5S120 Installation and Connection Guide

User Manual. Before using this device, read and follow all instructions for safety

Instruction Manual. Vogue. Security. Technology. Innovation 2013-V01

Single Door Standalone Access Control User Manual

Fingerprint Access Standalone User s Manual

Installation Guide (ver 1.0)

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

Fingerprint Access Control F1. User Manual

CV-945 Stand-Alone Biometric Reader. Installation Instructions

EX8. User Manual. Ver 1.0

CM-110SK Standalone Keypad Installation Instructions

Quick Installation Guide MAC1000/MAC1000SR STANDALONE BIOMETRIC CONTROLLER

Digital Keypad Introduction

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

IP based Fingerprint Access Control. Installation Guide.

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

BIOC3 V1 USER S MANUAL. Biometric Reader v. b1

Manual er under oversettelse til norsk.

smartentry Wireless Video Doorphone User Manual

GV-AS Controller. Installation Guide

Wiring Guide EP.NMINI. Version 1.02 Last Updated:

CRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09

Operation manual For NG BIOSINGLE Version 1.1

User Manual. Split access control with intelligent secured power supply.

Waterproof. Keypad/Reader/Controller

SCR100 User Manual. Version:1.1 Date:Dec 2009

Portals 14 What is a portal? 14 Hardware 15 RS232 to RS USB to RS TCP/IP to RS Add a Serial Portal 16 Add a Network portal 16

INSTALLATION GUIDE BioLite Net English Version 2.10 EN BLN V2.10A

INSTALLATION INSTRUCTIONS Model 930 EntryCheck

DOLXFD1000B. Waterproof Access Control/Reader

GV-AS/EV Controller. User s Manual

EL-ST100 KEYPAD CONTROLLER

W3-H Waterproof Keypad/Reader/Controller

ACCESS CONTROL QUICK INSTALL GUIDE. tel: +44 (0) fax: +44 (0) web:

Xpass S2. Installation Guide. Intelligent IP Access Control Reader EN XPS2 V1.11.

iface Series Installation Guide

INSTALLATION GUIDE BioEntry Plus English Version 2.11 EN BEP V2.11A

GV-AS/EV Controller. User s Manual

Access control panel U-Prox IC E (Elevator control)

2000 Series e/em Style Keypad Installation and Programming Manual

Connecting a Cisco Reader Module

CC Series metal access control Manual

TEC100 USER/INSTALLER MANUAL V2.0 REV. 03/2018

Quick Start Guide. GV-CS1320 Camera Access Controller

F18. Fingerprint capacity 3,000 Transaction capacity 100,000 Hardware Platform ZK 6001, 400Mhz 64M Flash, 32MSDRAM. Identification speed

INSTALLATION GUIDE BioEntry W English Version 2.10 EN BEW V2.10A

RD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

W3-M. Metal waterproof standalone access control/reader. User Manual

INSTALLATION GUIDE Xpass English Version 2.00 EN XPS V2.00A

Two Door Controller GEN-045

INSTALLATION GUIDE Xpass S2 English Version 2.2 EN XPS2 V2.20A

Partizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating

Installation Guide. UHF RFID Integrated Machine: U1000E, U1000F, U2000E, U2000F. Version: 1.0 Date:

REX F-0-9 Standalone or Access Controller

Encoder Firmware V User s Manual. Outdoor PTZ Camera Hardware Manual KCM /05/09.

Wiring Guide. EP.NMiNi 2. Version 1.04 Last Updated:

Wireless Digital Video Doorbell

Function Menu. 1.Add/Delete. 1. Password 2. Access Mode 3. Extend Options 4. Single Floor 5. Multi Floors 6. Enroll FP 7.

KP2000E/EM Series Style Keypad

Installation Instruction

User Manual Version 1.1 Date: March 2012

H2i. s u p p o r f i n g e r t e c. c o m. H2i. Simple Fingerprint Door Access & Time Attendance System. User Guide

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

Installation Instructions

genesis TECHNICAL MANUAL Two-Door Controller GEN-045

Installation & User Manual

Standalone Access Control

HSY-S209 EM Metal waterproof access control system User Manual

SL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description.

EZ-TAG2 Manual_Layout 5 11/12/ :14 Page 1 U S E R M A N UAL

iclock Access control Installation

Installation & User Manual V2.08

Suprex Ethernet SPX-7200 Ethernet Reader-Extender

CP150B Vandal & Weather Resistant Keypad Security Systems

B100-SA Standalone Biometric Reader

Specifications: Features:

ZAVIO Outdoor IR Mini Dome. Quick Installation Guide

Two-door Access Controller

232iLM Keypad Installation and Programming Instructions

BioEntry W. Installation Guide. Compact Outdoor Fingerprint Reader/Controller EN BEW V1.20.

VIDI-AC-2CS Access Controller/ Reader

Unit Door Station User's Manual ----VTO12XX Series

Full HD WDR Mini Dome IP Camera

INSTALLATION INSTRUCTION MANUAL

Transcription:

QUICK START GUIDE 2.4 Inch TFT Terminal Time Attendance & Access Control

Safety Precautions The following precautions are to keep user safe and prevent any damage. Please read carefully before installation. Do not install the device in a place subject to direct sun light, humidity, dust or soot. Do not place a magnet near the product. Magnetic objects such as magnet, CRT, TV, monitor or speaker may damage the device. Do not place the device next to heating equipment. Be careful not to let liquid like water, drinks or chemicals leak inside the device. Do not let children touch the device without supervision. Do not drop or damage the device. Do not disassemble, repair or alter the device. Do not use the device for any purpose other than those speci ed. Clean the device often to remove dust on it. In cleaning, do not splash water on the device but wipe it out with smooth cloth or towel. Contact your supplier in case of a problem.

Product PIN Diagram Camera 2.4-Inch TFT LCD Keypad USB Storage Device Port Reset Button Doorbell & LED Indicator Fingerprint Sensor & Card Reader Speaker Security Screw holes (for securing the device onto the back plate) 2

NC COM NO WD IWD I +2V RJ45- +2V Product PIN Diagram 8 pin Cable connectors Wiegand Out 4 pin Cable connectors (TCP/IP) 7 pin Cable connectors Beep, LED Wiegand In Power Out Lock Button Sensor Bell Auxiliary In Wiegand In Power Out 2 pin Cable connectors 2pin Cable connectors Tamper alarm button Lock Exit Button Door Sensor Doorbell Auxiliary In Lock Button Sensor Bell Auxiliary In COM NO NC WD IWD I +2V RJ45- +2V 3

Product Dimensions & Installation Product Dimensions 8.07in (205mm) 7.34in (86.5mm) 3.39in (86mm).78in (45.mm) 3.0in (76.mm) Mounting the device onto the wall Fix the back plate onto the wall using wall mounting screws Note: We recommend drilling the mounting plate screws into solid wood (i.e. stud/beam). If a stud/beam cannot be found, then use the supplied drywall plastic anchors. Use security screws to fasten the device to back plate 2 Inserting the device to backplate 4

Button Sensor Button Sensor NC COM NO NC COM NO WD WD IWD I +2V IWD I +2V RJ45- +2V RJ45- +2V Power Connection Without UPS Lock Bell Auxiliary In 2 2V DC 2V DC Adaptor With UPS (Optional) Lock Bell Auxiliary In 2 2V DC 2V DC Adaptor Recommended power supply 2V ± 0%, at least 500mA. To share the power with other devices, use a power supply with higher current ratings 5

Button Sensor NC COM NO WD IWD I +2V RJ45- +2V 23 4 56 7 8 Connection LAN Connection 4 Lock Bell Auxiliary In Network Cable Adaptor RJ 45 Cable ZKBiosecurity 3.0 PIN DESCRIPTION WIRE Black 2 Red 3 Green 4 RJ45- Yellow Note: The device can be connected to PC directly by ethernet cable. 6

Button Sensor NC COM NO WD IWD I +2V RJ45- +2V Connection PC Connection Lock Bell Auxiliary In 8 PIN DESCRIPTION WIRE Yellow 2 Blue 3 Black 4 Purple 5 Gray 6 Black 7 WD White 8 Green Do not use Important Notes:. communication wires should be a shielded and twisted pair of cable. 2. communication wires should be connected in a bus cascade instead of a star form, to achieve a better shielding e ect by reducing signal re ection during communications. 3. Adjust the communication speed as needed. The signal quality varies with wiring conditions, and it may be necessary to lower the baudrates. 4. The Signal may be omitted if and only if the potential di erence is less than ±5V 7

Button Sensor NC COM NO WD IWD I +2V RJ45- +2V Connection FR200 Connection PIN DESCRIPTION WIRE Brown 2 Gray 3 Blue 4 IWD Green 5 I White 6 Black 7 +2V Red Do not use PIN DESCRIPTION WIRE Yellow 2 Blue 3 Black 4 Purple 5 Gray 6 Black 7 WD White 8 Green 7 Lock Bell Auxiliary In 8 FR200 8

Settings System Settings for FR200 Connection Select > Comm Select > Serial Comm Select > /485 Change > to (master unit) DIP Settings. There are six DIP switches on the back of FR200, switches -4 are for address, switch 5 is reserved, switch 6 is for reducing noise on long cable. 2. If FR200 is powered from ProCapture terminal, the length of wire should be less than 00 meters or 330 ft. 3. If the cable length is more than 200 meters or 600 ft., the number 6 switch should be ON as below ON 2 3 4 5 6 Distance: More than 200 meters ON 2 3 4 5 6 9

Button Sensor NC COM NO WD IWD I +2V RJ45- +2V Lock Relay Connection Device Does Not Share Power With The Lock COM 2V DC Lock Bell Auxiliary In 2V DC Adaptor 2 PIN DESCRIPTION WIRE Red 2 Black 3 NC Gray 4 COM Black 5 NO White 6 Blue 7 Red 8 Yellow 9 Orange 0 Green Purble 2 Aux Brown Do not use Sensor NC + FR07 Diode - Normally Closed Lock Notes:. The system supports NO LOCK and NC LOCK. For example the NO LOCK (normally opened at power on) is connected with 'NO' and 'COM' terminals, and the NC LOCK (normally closed at power on) is connected with 'NC'and 'COM' terminals. 2. When electrical lock is connected to the Access Control System, you must parallel one FR07 diode (equipped in the package) to prevent the self-inductance EMF a ecting the system.! Do not reverse the polarities. 0

Button Sensor NC COM NO WD IWD I +2V RJ45- +2V Lock Relay Connection Device Shares Power With The Lock COM Lock Bell Auxiliary In 7 2V DC 2 PIN DESCRIPTION WIRE Red 2 Black 3 NC Gray 4 COM Black 5 NO White 6 Blue 7 Red 8 Yellow 9 Orange 0 Green Purble 2 Aux Brown Do not use Sensor NC + FR07 Diode - Normally Closed Lock

Button Sensor NC COM NO WD IWD I +2V RJ45- +2V Connection Lock Bell Auxiliary In 8 PIN DESCRIPTION WIRE Yellow 2 Blue 3 Black 4 Purple 5 Gray 6 Black 7 WD White 8 Green Do not use WD Advanced Access Control 2

Standalone Installation ZKBiosecurity 3.0 ZKBiosecurity 3.0 /485 Converter ALARM Sensor No Touch Lock EXIT Exit Button Doorbell 3

Device Operations Date / Time Settings Press M/OK > System > Date Time to enter Date Time setting interface. Adding User Press M/OK > User Mgt. > New User to enter the adding New User interface. Settings include inputting user ID, choosing user role (Super Admin / Normal User), registering ngerprint / badge number / password, taking user photo, and setting access control role. Adding a Super Admin: Select Super Admin in User Role to add a super admin. Adding a Normal User: Select Normal User in User Role to add a normal user. Settings Press M/OK > Comm. > to enter the setting interface. The parameters below are the factory default values, please adjust them according to the actual network situation. IP Address: 92.68..20 Subnet Mask: 255.255.255.0 Gateway: 0.0.0.0 DNS: 0.0.0.0 TCP COMM. Port: 4370 DHCP: Dynamic Host Con guration Protocol, which is to dynamically allocate IP addresses for clients via server. If DHCP is enabled, IP cannot be set manually. Display in Status Bar: To set whether to display the network icon on the status bar. 4

Device Operations & Troubleshooting Access Control Settings Press M/OK > Access Control to enter the Access Control setting interface. To gain access, the registered user must meet the following conditions:. User's access time falls within either user's personal time zone or group time zone. 2. User's group must be in the access combo (when there are other groups in the same access combo, veri cations of members of those groups are also required to unlock the door) Access Control Options: To set parameters of the lock and other related devices. Time Schedule: The smallest unit for access control. Holidays: To set dates of holiday and the access control time zone for that holiday. Access Groups: To divide and manage users in groups. Group members can either use the default group time zone or customize a personal time zone. Combined Veri cation: Combinations of veri cation methods Anti-passback Setup: To avoid unveri ed individuals from following the registered users to enter the door. Duress Options: If users unlock the door under threat, the device will open the door, meanwhile send signals to the backstage to trigger the alarm. Troubleshooting. Fingerprint cannot be read or it takes too long. Check whether a nger or ngerprint sensor is stained with sweat, water, or dust. Retry after wiping o nger and ngerprint sensor with dry paper tissue or a mildly wet cloth. If a ngerprint is too dry, blow on the nger and retry. 2. Fingerprint is veri ed but authorization keeps failing. Check whether the user is restricted by group or time zone. Check with administrator whether the enrolled ngerprint has been deleted from the device for some reasons. 3. Veri cation succeeds but door does not open. Check whether the lock open duration is set to appropriate time, which opens the lock. Check whether anti-passback mode is in use. In anti-passback mode, only the person who has entered through that door can exit. 4. The device displays system broken and the alarm is ringing. Check whether the device and back plate are securely connected to each other. If not, a tamper switch will be activated which triggers the alarm and keeps it rinng. 5