Up to two expansion cards can be added; these cards may either add an additional 4 analogue or 8 digital inputs.

Similar documents
SoundwebTM. Installation Guide

DATRAN XL4 PLUS RTU Quick Start Guide

Manual# Installation Manual. 200E Series. DCU 210E/208E Engine Panel RP 210E/220E Remote Panel

Installation Guide Serial Interface T942SI

NX21 USER MANUAL. Telemetry Unit. Version 1.5

Cardax FT Controller 3000

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

SoundwebTM. Installation Guide

LCI User Manual mantracourt.com

Product Data Sheet. BMS/Graphics Interface. Features

EasyIO FW 08VUser Reference

HRM-0800 Instruction Manual

NMID. Remote control. SAPIM I/O number. SAPIM I/O number NBRN (RS485) ZM100. Relay, 24 VDC - + UO07 UI11 UI10 UI09 UI08 UI07 UI06 UI05 UI04 UI03 UI02

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

IC693PWR331 High Capacity Power Supply, 24 VDC Input

C5S120 Installation and Connection Guide

Copyright Extract from Conditions of Sale Safety Warning

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

Table of Contents 1 ABOUT THIS GUIDE CONTACT INFORMATION ANTENNA INSTALLATION... 4

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-

170 ADI VDC - 16 Pt. Discrete Input Module Base

EZmoto V4.1 Product description Rev. 2 30/07/2015

C-Bus Pascal Automation Controller

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

E101 - Strain Gauge Transducer Display Module. Contents

MICRO-TRAK 300 MANUAL VER 1.4

EI Series INSTALLATION GUIDE INTRODUCTION. A Line of Fixed-Port Industrial Ethernet Hubs

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

TM221CE40T controller M IO transistor PNP Ethernet

Measurement Systems Datascan Installation and User Guide

SECTION 16 LED DIAGNOSTIC FEATURES: EXPANSION UNITS: SCR-31P-i. SCR-73-i. SEU-31-i. SCR-31-42TD-i. SEU-31TD-i

4100 and 4100/R Controllers

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

TM221CE24R controller M IO relay Ethernet

icex-cmtm General specs and Installation guide

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

EIDX_M Series INSTALLATION GUIDE INTRODUCTION. A Line of Managed Ethernet Switching Hubs

TWDLCAE40DRF compact PLC base Twido V AC supply - 24 I 24 V DC - 16 O

AX3000 Platine Terminal Ethernet TCP/IP

UK +44 (0) // USA // JAPAN //

Expansion Module HZS 541-1S

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

TM221M16R controller M IO relay

Fiber optic converter audio and CAN TA OPERATION MANUAL

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

TWDLCAE40DRF compact PLC base Twido V AC supply - 24 I 24 V DC - 16 O

Albatros 2 Grid supervision module / PSU User manual. AVS76.39x/309. Infrastructure & Cities. Edition 2.1

MAINS DISTRIBUTION UNIT MDU14-CO

TWDLCAE40DRF. Main. Range of product

SPECIFICATION FOR THE SUPPLY OF A BATTERY MONITORING SYSTEM

GS400. Electronic Auto-Ranging DIN Panel Mounted Positioner

MXPLC. Compact PLC process station. Summary. Application HVAC control systems, data acquisition, interfacing 3 rd party systems.

MODEL 805 USER MANUAL

Aarlogic TER-GX910. Product description. Rev.9 17/03/2013

APP 700 Technical Specification

TVI I300 Hardware Manual Essential Viewing Systems Limited Essential Viewing. TVI I300 Hardware Manual. Page 1

170 ADO VDC - 32 Pt. Discrete Output Module Base

TM221CE40R controller M IO relay Ethernet

DSE2548 LED expansion module INTRODUCTION

Installation Instructions

5B Series 16 Channel Backplane 5B01 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

The 2U package makes the unit suitable for using in workstations, storage systems, racks for industrial and many other applications.

TWDLCDE40DRF compact PLC base Twido - 24 V DC supply - 24 I 24 V DC - 16 O

TM221ME32TK controller M IO transistor PNP Ethernet

SA380TX-L Configuration & diagnostics software

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

HES-3109 SERIES 9 PORTS 10/100/1000BASE-T MANAGEMENT ETHERNET SWITCH

TM200CE24T controller M IO transistor Source+ Ethernet

OnCell G3100 Series Quick Installation Guide

GT- HE910-EUD. Product description Rev. 8 21/02/ Overview

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

MOTION COORDINATOR MC403 / MC403-Z Quick Connection Guide

UC-2000 Installation Manual Unicorn Computers Technology Limited

EZ864 UMTS Terminal Telit Cellular GSM Engine

Flomatic Smart Card TM Model FDHC-100 (Digital High-Resolution Controller) Configuration and Operation Manual

Thermocouple Input Module Product Specifications and Installation Data

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE

MC 11 EB-2 Power supply cabinet with external bus, AC version

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

Q22 DATRAN II excel Owners Manual

Data Manager Installation Guide

USER INSTRUCTION MANUAL FOR LOADCELL TRANSMITTER MODEL TDC/I/0550 (SOFTWARE: VER2A) INDEX

MXIO. Compact I/O module. Summary. Application Compact I/O module for data acquisition and HVAC control systems. Function

INDEX. Analog Board Boot and Voltage Test 2 Testing Input Channels 3 Testing Output Channels 4

Model HM-535 Power Supply Installation and Service Instructions

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

RibEye Multi-Point Deflection Measurement System 3-Axis Version for the SIDIIs ATD Hardware Manual for Model January 2010

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

KAUGJUHTIMISSÜSTEEMID TELECONTROL SYSTEMS MODEM TELEM-GSM/GPRS 3G. User manual

Operating and Maintenance Instructions

SLIMCON-6 24V DC POWERED ISOLATING SIGNAL CONVERTER

Integriti 8-32 Zone LAN Expander Module Kit INSTALLATION MANUAL

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

Data sheet GCM MOD GMM EC.1 Communications module Modbus for GMM EC

170 ADM to 60 VDC Module Base / 170 ADO Pt. Relay Out Module Base. Version 1.0

Transcription:

SA380TX-L Hardware The basic TX-L unit features: 4 digital inputs 2 analogue inputs 1 RS485 port 24v 2W auxiliary power supply GSM modem. An Ethernet port can be fitted as an option when ordering. Up to two expansion cards can be added; these cards may either add an additional 4 analogue or 8 digital inputs. Configuration Analogue Inputs Digital Inputs Base Unit (No Cards) 2 4 Base Unit + 1 Digital Card 2 12 Base Unit + 2 Digital Cards 2 20 Base Unit + 1 Analogue Cards 6 4 Base Unit + 2 Analogue Cards 10 4 Base Unit + 1 Analogue Card + 1 Digital Card 6 12 The diagram above shows a TX-L with one analogue expansion card and one digital expansion card installed. Contact MPEC for more information regarding the purchase of additional cards. Block diagram and isolation policy All of the green lines in the diagram below denote an isolation barrier. Every block of the TX-L shown is isolated from every other block and from the case. All of the individual analogue inputs are isolated from each other and from the auxiliary power supplies. Isolation barriers are to a minimum of 10M Ohms at 1,000V DC. The thick green lines denote two expansion cards that may be fitted. In this case one analogue and one digital card are shown.

Power supply - AC units only The universal input power supply accepts any voltage from 85 to 264V ac. A suggested connection is shown below. CAUTION: The MINIFIT power connector is not designed to be mated whilst live. Mate this connector prior to energising the unit. The power supply is internally isolated from earth and the rest of the SA380TX-L. Power can therefore be taken directly from the signalling 110V supply and no additional isolating transformer is required. The earth pin of the MINIFIT socket is connected to the case only. The TX-L does not have internal battery backup and so is not suitable for monitoring equipment such as level crossings where there is a long battery backup time, unless either: The TXL is powered from the level crossing battery (not currently permitted in the UK), or An external UPS (uninterruptible power supply) is provided with enough standby reserve to power the TX-L as long as the level crossing.

An internal 2A slow-blow fuse is provided. The external fuse must also be a minimum of 2A slow-blow (often marked T2A). Slow blow is required because of the inrush current of the power supply at start-up. Power consumption and external equipment Typical power consumption of the unit is between 2-10W. If the unit has to supply external equipment, for instance current clamps or network routers, then power consumption will rise accordingly. Maximum rated consumption is 40W. At 110V, this is 0.36A. Power supply - DC units only The power supply input accepts a DC voltage from 9 to 18VDC. 12VDC is the optimal voltage that should be applied. A suggested connection is shown below. CAUTION: The MINIFIT power connector is not designed to be mated whilst live. Mate this connector prior to energising the unit. DC Powered units have not been tested in accordance with the European EMC directive, therefore such units do not comply with European CE marking directive. The power supply is internally isolated from earth and the rest of the SA380TX-L. The earth pin of the MINIFIT socket is connected to the case only. The TX-L does not have internal battery backup and so is not suitable for monitoring equipment such as level crossings where there is a long battery backup time, unless either: The TXL is powered from the level crossing battery (not currently permitted in the UK), or An external UPS (uninterruptible power supply) is provided with enough standby reserve to power the TX-L as long as the level crossing. An internal 5A slow-blow fuse is provided. The external fuse must also be a minimum of 5A slow-blow (often marked T5A). Slow blow is required because of the inrush current of the power supply at start-up. Power consumption and external equipment

Typical power consumption of the unit with no sensors attached is between 2-10W. If the unit has to supply external equipment, for instance current clamps or network routers, then power consumption will rise accordingly. Maximum rated consumption is 40W. At 12V, this is 3.34A. CAUTION: The unit can support a maximum load of 2W per analogue channel or a total load of 10W per unit in the DC configuration. For example, if a constant load of 2W is applied to each analogue channel, a total of 5 channels can be utilized. If a constant load of 1W is applied to each analogue channel, all 10 analogue channels may be utilized. Digital inputs Four digital inputs are provided to monitor spare contacts of signalling relays. These inputs are connected as follows: All of the terminals marked C are connected together internally. This allows easy wiring to signalling relays using twisted pair cable, as specified in railway standards. Internal resistors limit the sense current to a few milliamps at 24V. The digital inputs are fully isolated to a minimum of 10M Ohm at 1,000V DC. This isolation ensures that the inputs are fully separate from earth, the logger s internal logic and the analogue inputs. Digital inputs must never be connected into a live circuit (e.g. across a contact that is already in use by the signalling system). They must only ever be connected to spare relay contacts. Extra care must be taken when monitoring geographical type relay interlockings, as there are internal connections within the relay sets which are not obvious just from the plugboard positions. We recommend that full signal works testing procedures are used for geographical interlockings, not just Instrumentation Engineer. Also the original interlocking diagrams should be updated if overlay diagrams are used, there is a risk if other persons change the interlocking circuitry in future. These inputs are for use with volt-free relay contacts only. Do not apply voltages to these inputs. Analogue inputs

Analogue inputs are designed to accept industry standard 4-20mA sensors. Many types of external sensor are available with a 4-20mA output, including current clamps, temperature sensors, pressure sensors and voltage transducers. Each analogue card has four isolated channels, which are capable of powering 4-20mA current clamps. The terminals are: 24: 24V out S: Signal input 0: 0V The input impedance between S and 0 terminals is 200ohms. The maximum output power of the 24V sensor power feed is 2W, or 83mA, per analogue input. CAUTION: The unit can support a maximum load of 2W per analogue channel or a total load of 10W per unit in the DC configuration. For example, if a constant load of 2W is applied to each analogue channel, a total of 5 channels can be utilized. If a constant load of 1W is applied to each analogue channel, all 10 analogue channels may be utilized. Auxiliary power out Each card can be factory fitted with an auxiliary power output on request. For instance a +12V output could be used to power an Ethernet router or a fibre-ethernet converter, or to power sensors that require their own power supply. Analogue inputs must never be connected directly to any signalling supplies or circuits. This includes (but is not limited to) B24, B50, BX110, track circuits and signalling line circuits. The simplest 4-20mA sensors only have two connections and take their power entirely from the loop. Others have three or four wires. The four wire types use a separate signal and power ground to avoid interference between the power supply and measurement currents. Example wiring to the different types is shown below:

RS485 (EbiTrack ) The isolated RS485 communications port may be used to monitor the Bombardier EbiTrack 200, 300 and 400 range of digital track circuit transmitters and receivers. Up to eight EbiTrack units may be monitored using a single TX-L using a multi-drop RS485 network. Configure the network as shown below using twisted pair cable. Termination resistors are used at each end of the link. The EbiTrack units RS485 interface utilises a 9-pin D-sub connector.

The connector must be wired as follows: Pin 1: RS485 Mode Select (Connect to Pin 9) Pin 2: Signal Pair (Connect to RS485 line B) Pin 6: Signal Pair (Connect to RS485 line A) Pin 9: 5V DC (Connect to Pin 1) Front panel USB Diagnostics On-site configuration, diagnostics and data interrogation is performed by connecting a laptop to the TX-L using the supplied USB cable. The USB port is electrically isolated from the signalling inputs of the TX-L. Your laptop must be running MPEC s dpanel software in order to communicate with the TX-L (see Configuration and Diagnostics section). LED s The TX-L front panel features 8 LEDs. The meaning of these LEDs is detailed in the table below: LED Indication Meaning Server Steady On Last transmission of sample data to the Central Data Server successful. Server Fast Blink** Device is attempting to connect with the server. Server Slow Blink** Transmission to the Central Data Server has recently failed. Device is now in FALLBACK Server Off There is no data connection to the server Comm Steady On Connected to the GSM Network GSM Steady On Modem Powered On Master/Slave Slow Alternating Flash (1 sec) Normal Operation Master/Slave Fast Flash (0.25 sec) Processor Sync Error* Master/Slave Steady On or Off Processor Error

Storage Blinking Data Read/Write from database Storage Steady On Database Error Input Blinking Analogue or Digital Input Event Detected RS485 Blinking Data Transmit/Receive on RS485 Port *It is normal to observe a Processor Sync Error during initial boot and during firmware upgrade. ** The table describes behaviour in MIMOSA protocol mode. In RailDAQ mode, the following behaviour is observed: The server connection LED will not show fallback, as the timeout is short. During Firmware upgrade over RailDAQ, the server LED will not illuminate. If the device is not configured within Centrix, the server LED will not illuminate, as it cannot transmit samples. Restart Comms Button Pressing this button forces the modem to immediately power-cycle and attempt reconnection with the GSM service provider and the central data server. When connected over Ethernet, any existing connection will be dropped and reinitialised. GSM antenna The supplied GSM antenna, unlike many antennas, is an impedance matched, balanced antenna. Such antennas do not need a ground plane reference (such as the metalwork of a location case) to function. As such they are inherently safer and more immune to interference. The old-style black, square puck antennas previously shipped with SA380TX and SA380TX-L should no longer be used. These are NOT suitable for use at 3G frequencies. Instead a new light-grey antenna is shipped with the units. This new antenna offers great performance for a compact size at 2G and 3G frequnecy bands. It is also able to be mounted in a similar fashion to the old-style version.

The antenna is to always be fitted to the exterior of the location case or equipment room and connects to the rear of the logger with a screw-fit connector. A suitable aperture is to be usually found on the side of most location cases. To mitigate against the unlikely event of a right-side failure, it is recommended that the length of the antenna cable is not altered and that the cable is routed separately to other cabling susceptible to interference, such as EbiTrack track circuit feeds, or SSI data links. Ethernet When fitted, the Ethernet card may be used for data transmission and remote accessibility at higher data rates. Any standard RJ45 UTP network cable may be fitted to this port. The TX-L can then be connected to your own IT infrastructure using any standard Ethernet switch or router. In order to fully comply with Railway EMC regulations (radiated emissions) please ensure that an RF choke is clipped around the end of the Ethernet cable (as shown below). Ethernet Choke part number: Wurth Elektronik 741 717 22