DPOM8-24/20 DIN RAIL POWER OVER MODBUS MODULE. Mounting and operating instructions

Similar documents
CNVT-USB-RS485 MODBUS TO USB CONVERTER. Operating instructions

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

RТTH DUAL ROOM SWITCH

RXTP ROOM TEMPERATURE

RXTH DUAL ROOM SENSOR / SWITCH

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

MVS RAIL ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions

HPS-M -2 DIFFERENTIAL PRESSURE TRANSMITTER. Mounting and operating instructions

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

Installation manual for for Schleifenbauer DPM3


See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

General Specifications

Operating instructions. Switching amplifier DN0210 DN / / 2015

RS232C/RS485 Data can be easily monitored by LAN

Priva Blue ID Digital input module DI4/DI8/DI16

LZR - U920/-U921. LASER MEASUREMENT DEVICE with bidirectional bus communication. User s Guide for product version 0500 and more

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Language of the manual

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

Operating instructions. Speed monitor D / / 2014

B63/ NS MS. EtherNet/IP LINK

S SENECA. Installation Manual Z-TWS4. Z-PC Line. Web Multifunction Controller Straton / Linux

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

INSTALLATION MANUAL. Gateway option box EKLONPG EKBNPG

CU USB-Extender-Rx (USB and DVI Extender) Version: 0.3 Date:

8-Port IP40 IEEE802.3af PoE Unmanaged Industrial Switch User s Manual

MOXA Industrial Media Converter

AMP20. User Manual.

IntesisBox Modbus Server Panasonic

Output Signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power Supply DC V, ±10%, 0.3 W

User Manual. Printer P-52RUE

User Manual EzLogger WiFi Ver 02

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter

MP211 HARDWARE MANUAL

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

APC100. User Manual.

User Manual Entry Line Industrial Fast Ethernet Switch 5x 10/100Base-TX

Output Signal. Temperature 22DTH-56M BACnet DC V, DC V. Electrical Data Power Supply DC V, ±10%, 0.7 W

CoolPlug CooLinkHub HVAC Bridge. Quick Installation Guide

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

Gateway BACnet IP/MS-TP slave KNX TP Code: EK-BJ1-TP-IP / EK-BJ1-TP-MSTP

SMART-e Document Rev1

Installation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date:

LED W RGBA User Manual

Instruction Manual. T3110 T3110L T3110Ex

CSMIO-MPG. 6-axis Manual Pulse Generator (MPG) Module. Rev copyright 2014 CS-Lab s.c.

Priva Blue ID Communication module RS485 SC44

Blue ID Communication module RS485 SC44

USER MANUAL VIBRATION CONTROL RMA-POWER-BOX 107/230

CoolPlug CooLinkHub HVAC Bridge. Quick Installation Guide

TN-5308 Quick Installation Guide

Chrome DIN Rail Power Supply 5V 7.5W 1 Phase (Class II & NEC Class 2) / DRC-5V10W1AZ

Operating Manual. English. Digital-Analog Converter DACON8-UMB.

DIFFERENTIAL PRESSURE TRANSMITTER with MODBUS interface Optional Input module

Modbus Digital Remote I/O. ARM Series. Modbus Sensor Connector Type Digital Remote I/O. Features. User Manual For Communication. Ordering Information

Chrome DIN Rail Power Supply 12V 9.96W 1 Phase (Class II & NEC Class 2) / DRC-12V10W1A

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Features: S98-B v1.0 S98-B 9-port switch with buffer power supply for 8 IP cameras

DMX LED Starcloth Systems

Fog machine PT Users Manual

Simple but elegant look and ease of installation make it ideal for various industrial applications.

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

Network Instrumentation Module Communications box NX-CB1 Communications adapter NX-CL1/NX-CR1 Terminal adapter NX-TL1/NX-TR1

Crossfire. User Manual. Order code: EQLED061

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

V /06/ Velleman nv

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

Features: DSB98 v1.0 DIN rail mounted switch 9-port DSB98 with buffer power supply for 8 IP cameras

MOXA EtherDevice Switch

Rev1 QP-10-IM21UL/Rev Rev2 QP-10-IM21UL/Rev Rev3 QP-10-IM21UL/Rev Rev4 QP-10-IM21UL/Rev4

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

IntesisBox Modbus Server Fidelio IP

Rhino PSM Power Supplies. Operating Instructions

Digital Overhead Stirrer

TCNM-ACBB1 Installation Manual

650/1000 Fresnel 650/1000 PC 300/500 Antihalo 300/500 Fresnel theatre spotlight. user manual

ADA User manual ADA RS-485 / RS-422 to RS-232 Converter. 1 io_ada-4010_v3.22_en. Copyright CEL-MAR sp.j.

Three-phase electricity meter with instantaneous reading of electrical variables. Input current measurement: 5 A, 90 A, 150 A, 250 A (span by model).

COMPACT eco -DIN Document Rev1

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A


MODEL: R2K-1 SEN TRONIC AG. R2K Series

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

Transcription:

Mounting and operating instructions

Table of contents SFETY ND PRECUTIONS 3 PRODUCT DESCRIPTION 4 RTICLE CODES 4 INTENDED RE OF USE 4 TECHNICL DT 4 STNDRDS 4 WIRING ND CONNECTIONS 5 MOUNTING INSTRUCTIONS IN STEPS 5 VERIFICTION OF THE INSTLLTION INSTRUCTIONS 7 TRNSPORT ND STOCK KEEPING INFORMTION 7 WRRNTY INFORMTION ND RESTRICTIONS 7 MINTENNCE 7 2-7

SFETY ND PRECUTIONS Read all information, the datasheet, mounting instructions and wiring scheme before working with the product. For personal and equipment safety, and for optimum product performance, make sure you entirely understand the contents before installing, using, or maintaining this product. For safety and licensing (CE) reasons, unauthorised conversion and / or modifications to the product are not permitted. The product must not be exposed to abnormal conditions, such as: extreme temperatures, direct sunlight or vibrations. Chemical vapours with high concentration in combination with long exposure times can affect the product performance. Make sure the work environment is as dry as possible; check for condensation spots. ll installations shall comply with the local health and safety regulations and local electrical codes. This product can only be installed by an engineer or a technician who has an expert knowledge of the product and safety precautions. void contacts with energised electrical parts; always treat the product as if it is life. lways disconnect the power source before connecting the power cables, servicing or repairing the product. lways verify that you apply appropriate power supply to the product and use wires with appropriate size and characteristics. Make sure that all the screws and nuts are well tightened and fuses (if any) are fitted well. Recycling of equipment and packaging should be taken into consideration and disposed in accordance with local and national legislation / regulations. In case there are any questions that are not answered, please contact your technical support or consult a professional. 3-7

PRODUCT DESCRIPTION DIN rail mounted Power over Modbus supply modules with 24 VDC output and an integrated and fully isolated Modbus RTU communication line repeater with a transmitting side indication. The DPOM8 can also be used as a power supply module for Sentera sensors and switches. RTICLE CODES Code DPOM8-24 / 20 Supply voltage 85 264 VC / 50 60 Hz INTENDED RE OF USE TECHNICL DT In combination with all Sentera products with integrated Modbus RTU communication, including units that need galvanic isolation between receiving and transmitting sides s a power supply module for sensors and switches For indoor use only! Supply voltage: 85 264 VC / 50 60 Hz Output for Modbus RTU with integrated power supply: 24 VDC / 20 W Galvanic isolated half-duplex Modbus RTU communication mode repeater Input and output connections with terminal blocks or RJ45 (Power over Modbus) connection Overload hiccup mode protection with red LED indication Input and output green LED transmitting indications synchronous serial data transmission utomatic baud-rate fitting up to 115,2 Kbps Up to 1.200 m distance Up to 32 modules can be connected, depending on distance and power consumption Galvanic isolation DIN rail mounting according to EN 50022 Enclosure: BS plastic, colour: grey, RL7035 Operating ambient conditions: temperature range: -20 40 C rel. humidity: 5 85 % rh (non-condensing) STNDRDS Low Voltage Directive 2014/35/EC EMC Directive 2014/30/EC WEEE Directive 2012/19/EC RoHs Directive 2011/65/EC 4-7

WIRING ND CONNECTIONS L N Power supply, Line: 86 264 VC / 50 60 Hz Power supply, Neutral: 86 264 VC / 50 60 Hz Modbus RTU (RS485), signal Modbus RTU (RS485), signal 24 VDC Terminal blocks for supply output voltage connection (24 VDC / 20 W) GND Input Output Ground reference for supply output Modbus RTU communication RJ45 socket. (No integrated 24 VDC on this port) Power over Modbus communication RJ45 socket. (Modbus RTU + 24 VDC) RJ45 Sockets Pins 3 & 4 Input Pins 5 & 6 Pins 1 & 2 Pins 3 & 4 Output Pins 5 & 6 Pins 7 & 8 Modbus RTU signal (RS485) Modbus RTU signal (RS485) 24 VDC / 20 W Modbus RTU signal (RS485) Modbus RTU signal (RS485) Ground MOUNTING INSTRUCTIONS IN STEPS Before you start mounting the DPOM8-24 Power over Modbus module, read carefully Safety and Precautions. Then proceed with the following mounting steps: 1. Slide the unit along the guides of a standard 107 mm DIN rail and fix it to the rail by means of the black locking clip on the enclosure. Mind the correct position and mounting dimensions shown in Fig. 1 Mounting dimensions and Fig. 2 Mounting position. Fig. 1 Mounting dimensions Fig. 2 Mounting position 87,5 92 65,5 Din-rail Locking clip Lock release 5-7

2. C onnect the mains supply to the L and N terminal blocks and connect the RJ45 sockets (see Example 1 Connections via RJ45 connectors) or terminal blocks to the Input / Output (see Example 2 Connections via RJ45 to terminal blocks), or make the connections via terminal blocks (see Example 3 Connections via terminal blocks) according to the wiring diagram in Fig. 3. Next, switch on the supply voltage. Fig. 3 Wiring diagram Example 1: Connections via RJ45 connectors C supply source 85 264 VC / 50 60 Hz Pins 3&4 Modbus RTU Pins 5 & 6 Modbus RTU Pins 3&4 Modbus RTU signal (RS485) signal (RS485) signal (RS485) Pins 1 & 2 24 VDC (24 VDC / 20 W) Pins 5 & 6 Modbus RTU signal (RS485) Pins 7 & 8 Ground Differential pressure sensor with RJ45 socket Output Input CNVT-USB-RS485 RJ45 Example 2: Connections via RJ45 connection to terminal blocks C supply source 85 264 VC / 50 60 Hz 24 VDC GND 1 2 3 4 RJ45 5 6 7 1 2 3 4 5 6 7 8 8 Room sensor CNVT-USB-RS485 RJ45 Example 3: Connections via terminal blocks Room sensor C supply source 85 264 VC / 50 60 Hz CNVT-USB-RS485 MIW-DPOM8-24-20-EN-000-17 / 01 / 2017 24 VDC,,, GND www.sentera.eu 6-7

TTENTION Use a Cat 5E straight-through cable according to Standard 568 or equivalent for the input and output Power over Modbus communication RJ sockets. TTENTION When connecting longer lines, use the lowest possible baud rate. The Input / Output terminal blocks duplicate the Input / Output RJ sockets. VERIFICTION OF THE INSTLLTION INSTRUCTIONS 1. fter switching the controller on and establishing communication, the green LEDs (Input ctive and Output ctive ) should blink to indicate that the communication is active. (see Fig. 5. Communication active). In case of overload, the red LED starts blinking (see Fig. 6. Overload). 2. Blinking green LEDs on the RJ connectors (RX and TX) indicate that the Modbus RTU communication is active (see Fig. 7 Communication LED indications ). Fig. 5 Communication active Fig. 6 Overload Fig. 7 Communication active TTENTION High voltage! The unit is supplied with electrical energy at voltages high enough to inflict personal injury or threat to health. void contact with the unit when in operation! TTENTION Hot surface! The surface of the unit may become hot and cause burns if touched. void contact with the unit when in operation! TRNSPORT ND STOCK KEEPING INFORMTION void shocks and extreme conditions. Stock in original packing at temperatures -20 50 C. WRRNTY INFORMTION ND RESTRICTIONS Two years from the delivery date against defects in manufacturing. ny modifications or alterations to the product after the date of publication relieve the manufacturer of any responsibilities. The manufacturer bears no responsibility for any misprints or mistakes in this data. MINTENNCE In normal conditions these controllers are maintenance-free. If soiled, clean with a dry or dampish cloth. In case of heavy pollution, clean with a non-aggressive product. In these circumstances, the unit should be disconnected from the main supply. Pay attention that no fluids enter the unit. Only reconnect the controller to the main supply when it is completely dry. MIW-DPOM8-24-20-EN-000-17 / 01 / 2017 www.sentera.eu 7-7