UniStream CPU-for-Panel

Similar documents
UniStream HMI Panel. CPU-for-Panel

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10

Vision OPLC. General Description. Standard Kit Contents. Installation Guide Vision120. This guide provides basic information for Unitronics Vision120.

Failure to comply with appropriate safety guidelines can cause severe injury or property damage.

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

EX-RC1 Remote I/O Adapter

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Installation Guide V1210-T20BJ This guide provides basic information for Unitronics controllers V1210-T20BJ.

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Failure to comply with appropriate safety guidelines can cause severe injury or property damage.

Screen 2.4" 3.5" Color Touch 4.3" Color Touch. RS232/485 Yes Yes Yes Yes Yes* USB device, mini-b Com Ports, separate order, user-installed

This guide provides basic information for Unitronics Models V230/260/280/290 (Non-color Screens).

This guide provides basic information for Unitronics Models V230/260/280/290 (Non-color Screens).

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

EX-RC1 Remote I/O Adapter

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Vision OPLC V TR20

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Vision OPLC V TR20/V350-J-TR20

Component identification

V E5B Snap-in I/O Module

Vision OPLC. General Description.

IO-DI8-RO8, IO-DI8-RO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

V E62B Snap-in I/O Module

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

IO-DI16, IO-DI16-L I/O Expansion Modules

High Speed Remote I/O Module

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

Vision OPLC. General Description. Installation Guide V T34.

This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens).

UniStream. Built-in. Installation Guide: US7-B5-B1, US7-B10-B1, US7-B5-TR22, US7-B10-TR22, US7-B5-T24, US7-B10-T24

EX-RC1 Remote I/O Adapter

Installation Guide V1210-T20BJ This guide provides basic information for Unitronics controllers V1210-T20BJ.

Vision OPLC V TR6/V350-J-TR6

The identified danger could cause physical and property damage.

22 Digital Inputs, including 2 Analog, 2 HSC/Shaft-encoder inputs 16 Transistor Outputs

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

OPLC Installation Guide

This guide provides basic information for Unitronics controllers V C30B and V T40B.

High Speed Remote I/O Module

IO-DI8-RO4, IO-DI8-RO4-L I/O Expansion Modules 8 Inputs, 4 Outputs

Vision OPLC. V T38 Installation Guide. General Description

This guide provides basic information for Unitronics controller model V T2.

This guide provides basic information for Unitronics Models V230/260/280/290 (Non-color Screens).

General Description V TR34/V130-J-TR34 V TR34/V350-J-TR34 V430J-R34 V R34/V130-J-R34 V R34/V350-J-R34

Vision OPLC V TR20

V TU24 V350-J-TU24

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

Micro-OPLC Installation Guide

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Screen 2.4" 3.5" Color Touch 4.3" Color Touch. RS232/485 Yes Yes Yes* Yes* Yes* USB device, mini-b Com Ports, separate order, user-installed

Unitronics Devices and RS485 Table Of Contents

IO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation Systems 1

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

V E2B Snap-in I/O Module

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs

V E1B Snap-in I/O Module

V E2B Snap-in I/O Module

Vision OPLC. Technical Specifications. V T34 Technical Specifications

User safety and equipment protection guidelines

V E3XB Snap-in I/O Module

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

V E1B Snap-in I/O Module

IO-LC1, IO-LC3 I/O Expansion Modules 1-3 Loadcell Inputs, 1 Digital In, 2 Out

Vision OPLC. V TR6 Technical Specifications. Technical Specifications.

Using your PC to access a remote M90 via GSM

20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1 npn inputs

V350-RA22 V350J-RA22.

3 Digital, 3 Digital/Analog, 3 PT1000/NI1000 Inputs, 5 Relay, 1 pnp/npn Outputs

Smart Portal SP5000SERIES

V E6B Snap-in I/O Module

V E3XBW Snap-in I/O Module

V E4XB Snap-in I/O Module

LIMANDA Handheld Enclosures Product Drawings Last Updated 6/5/2008

V E3XB Snap-in I/O Module

SNAP PAC Redundancy Option Kit

DINALOG A 96 x 24. Programmable quasi-analogue bar graph meters. Technical characteristics DINALOG A 96 x 24

CARLO GAVAZZI. Automation Components. The quick-fit energy metering solutions

FiberINTER. FiberINTERF. FiberINTERFACES.

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Package Contents. GP Options (Made by Digital)

PanelView 800. Allen-Bradley Component Level Human Machine Interface Solutions

VENTILATION. Short catalogue VENTILATION COMMON FEATURES.

PACSystems RX7i IC698CHS009/119

FX1N-4EX-BD Input Expansion Board

1. Safety Precautions (Read these precautions before use.)

Medium Voltage Solutions For Water and Wastewater Treatment

CARLO GAVAZZI Automation Components. Wireless Safety System

FX2NC-ENET-ADP Ethernet adapter USER'S MANUAL

INSTALLATION INSTRUCTIONS

FX1N-2EYT-BD Output Expansion Board

efive 100 Installation Guide

Bulletin 1492 In-Panel I/O Wiring System Modules and Cables for Allen-Bradley Programmable Controllers Reduced Wiring Time, Accurate Connections

UDS-Universal Docking Stations Product Drawings Last Updated 4/22/2008

Micro800 Programmable Controllers

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

User Manual Entry Line Industrial Gigabit Ethernet High Power 60/95 W PoE Injector

Transcription:

UniStream CPU-for-Panel Installation Guide USC-P-B10 Unitronics UniStream platform comprises control devices that provide robust, flexible solutions for industrial automation. This guide provides basic installation information for the UniStream CPU-for-Panel. Technical specifications may be downloaded from the Unitronics website. The UniStream platform comprises CPU controllers, HMI panels, and local I/O modules that snap together to form an all-in-one Programmable Logic Controller (PLC). Expand the I/O configuration using a Local Expansion Kit or remotely via CANbus. CPU-for-Panel HMI Panels Available in different dimensions I/O Options Programming Software CPUs are Programmable Logic Controllers (PLCs), the heart of the UniStream platform. The CPU-for-Panel cannot operate independently. It must be plugged into the back of a UniStream HMI panel. The panel provides the CPU s power source. The CPU-for-Panel comprises: IO/COM Bus connector for interfacing Uni-I/O & Uni-COM modules Isolated RS485 and CANbus ports Backup battery A high-resolution touch screen provides the operator interface for the system and the physical foundation for a PLC+HMI+I/Os all-in-one controller. The DIN-rail structure on the panel s back is designed to physically support a CPU-for-Panel controller, Uni-I/O and/or Uni-COM modules. Each panel comprises: AUX connector to support the CPU 1 audio-out 3.5mm jack 1 microsd slot 2 type A, USB host ports and 1 Mini-B USB device port 2 Ethernet ports, RJ45, 10/100 Mbps 1 power input connector, 12/24 VDC Integrate I/Os into your system by using: On-board I/Os: snap onto the panel for an all-in-one configuration Local I/O via a Local Expansion Kit Remote I/O via EX-RC1 All-in-one UniLogic software, for hardware configuration, communications, and HMI/PLC applications, available as a free download from Unitronics web site. Use of this product is subject to a Unitronics Controller License Agreement, a copy of which can be found at http://unitronics.com/unistream/agreements/unilic1.pdf Unitronics 1

CPU-for-Panel Installation Guide Before You Begin Before installing the device, the installer must: Read and understand this document. Verify the Kit Contents. Note that the CPU-for-Panel is intended to be installed on the back of an HMI panel. Alert Symbols and General Restrictions When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Danger The identified danger causes physical and property damage. Warning Caution Caution Use caution. The identified danger could cause physical and property damage. All examples and diagrams are intended to aid understanding, and do not guarantee operation. Unitronics accepts no responsibility for actual use of this product based on these examples. Please dispose of this product according to local and national standards and regulations. This product should be installed only by qualified personnel. Failure to comply with appropriate safety guidelines can cause severe injury or property damage. Do not attempt to use this device with parameters that exceed permissible levels. Do not connect/disconnect the device when power is on. Environmental Considerations Ventilation: 10mm (0.4 ) of space is required between the device top/bottom edges and the enclosure s walls. Do not install in areas with: excessive or conductive dust, corrosive or flammable gas, moisture or rain, excessive heat, regular impact shocks or excessive vibration, in accordance with the standards and limitations given in the product s technical specification sheet. Do not place in water or let water leak onto the unit. Do not allow debris to fall inside the unit during installation. Install at maximum distance from high-voltage cables and power equipment. 2 Unitronics

UniStream Kit Contents 1 CPU-for-Panel 1 lithium battery, 3V, CR2032. The battery is installed; pull out plastic tab to activate it. 1 RS485 terminal block 1 CANbus terminal block 1 CANbus termination resistor 1 set of module numbering stickers. Numbering instructions are in Uni-I/O & Uni-COM module installation guides. CPU-for-Panel Diagram CPU-for-Panel Front and Rear View 1 DIN-rail clips 5 RS485 connector 2 Battery pull-tab (remove during installation) 6 RS485 termination selection DIP switch 7 CANbus connector 3 Battery compartment cover 8 CPU door 4 IO/COM Bus connector, shipped 9 CPU connector to panel covered. Leave covered when not in use. Installation Space Considerations Allocate space for: The HMI Panel including the CPU and any modules that will be installed on it Opening the doors of the CPU and modules For exact dimensions, please refer to the Mechanical Dimensions shown below. Unitronics 3

CPU-for-Panel Installation Guide CPU-for-Panel Mechanical Dimensions Side View Front View Battery: Back-up, Installation, and Replacement Backup In order to preserve back-up values for RTC and system data in the event of power off, the battery must be connected. Battery Installation The CPU is shipped with a battery installed, but with a plastic Battery pull-tab inserted in the battery compartment. Pull out the Battery pull-tab during installation in order to connect the battery. Battery Replacement Caution Use proper precautions to prevent Electro-Static Discharge (ESD) while servicing the battery. To preserve back-up values for RTC and system data during battery replacement, the CPU-for-Panel must be powered from the HMI Panel. 4 Unitronics

UniStream 1. Open the CPU door and remove the battery cover. 2. Remove the used battery and insert the new one, ensuring that the polarity is aligned with the polarity drawing as shown in the accompanying figure. 3. Replace the battery cover. 4. Dispose of the used battery according to local and national standards and regulations. Battery Polarity Installation Turn off system power before connecting or disconnecting any modules or devices. Use proper precautions to prevent Electro-Static Discharge (ESD). The AUX connector on the back of the HMI panel provides the connection point for the CPU-for-Panel, including power. The DIN-rail type structure on the back of the panel provides the physical support. 1. Remove the AUX connector cover from the panel (the cover may be saved for future use). 2. If a Uni-I/O or Uni-COM module, or a Local Expansion Kit is to be connected to the CPU-for-Panel, remove the IO/COM Bus connector cover. 3. Plug the CPU-for-Panel into the HMI Panel AUX connector. If an adjacent module is already installed, slide the CPU-for-Panel into place via the guide tunnels shown in the accompanying figure. 4. Verify that the DIN-rail clips located on the top and bottom of the CPU-for-Panel have snapped onto the DIN-rail structure on the back of the panel. Removing the CPU-for-Panel 1. Power off the HMI Panel before removing the CPU-for-Panel. 2. Disconnect the RS485 and the CANbus connectors (if relevant). 3. Disconnect the module connected to the CPU (by pushing its Bus Connector lock to the right). 4. On the CPU-for-Panel pull the top DIN-rail clip up and the bottom clip down. 5. Pull the CPU-for-Panel out of its place. Unitronics 5

CPU-for-Panel Installation Guide About the CPU s IO/COM Bus Connector The IO/COM Bus connector on right side of the CPU-for-Panel provides the electrical connection point for a Uni-I/O or Uni-COM module or Local Expansion kit. The connector is shipped covered by a protective cover, protecting the connector from debris, damage, and ESD. 9BWiring When no module is connected to the CPU, its IO/COM Bus Connector Cover must remain installed. Turn off system power before connecting or disconnecting modules. This equipment is designed to operate only at SELV/PELV/Class 2/Limited Power environments. All power supplies in the system must include double insulation. Power supply outputs must be rated as SELV/PELV/Class 2/Limited Power. Do not connect either the Neutral or Line signal of the 110/220VAC to device s 0V point. Do not touch live wires. All wiring activities should be performed while power is OFF. Unused points should not be connected (unless otherwise specified). Ignoring this directive may damage the device. Double-check all wiring before turning on the power supply. Caution To avoid damaging the wire, use a maximum torque of 0.5 N m (5 kgf cm). Do not use tin, solder, or any substance on stripped wire that might cause the wire strand to break. Install at maximum distance from high-voltage cables and power equipment. 15BWiring Procedure Use crimp terminals for wiring; use 26-12 AWG wire (0.13 mm 2 3.31 mm 2 ). 1. Strip the wire to a length of 7±0.5mm (0.250 0.300 inches). 2. Unscrew the terminal to its widest position before inserting a wire. 3. Insert the wire completely into the terminal to ensure a proper connection. 4. Tighten enough to keep the wire from pulling free. 16BWiring Guidelines In order to ensure that the device will operate properly and to avoid electromagnetic interference: Use a metal cabinet. Make sure the cabinet and its doors are properly earthed. Use wires that are properly sized for the load. NOTE For detailed information, refer to the document System Wiring Guidelines, located in the Technical Library in the Unitronics website. 6 Unitronics

UniStream Communication Ports Turn off power before making any communications connections. RS485 Use the RS485 port to create a multi-drop network. The CPU-for-Panel is shipped with a 4 pin RS485 terminal block. This connector is marked with a pin assignment that is identical to the corresponding marking on the CPU-for-Panel. RS485 Wiring D+ Tx/Rx+ (B) D- Tx/Rx (A) SG Signal Ground Functional Ground Use shielded twisted-pair cable, in compliance with EIA RS485 specifications. When wiring each node, connect the cable shield to the functional ground point of the RS485 terminal block. Caution In order to avoid ground-loops, do not connect the RS485 functional ground terminal to the earth of the system, as it is internally connected to the HMI panel s functional ground point. RS485 Termination Use the DIP switches shown in the panel diagram on page 3 to set the RS485 termination according to the accompanying table. The device is shipped with both its DIP switches set to ON; change settings if the device is not at one of the ends of the RS485 network. Position 1 2 DIP Switch State ON ON Terminated (factory default) OFF OFF Not Terminated Unitronics 7

CPU-for-Panel Installation Guide CANbus Use the CANbus port for all CANbus communications including integration of Remote I/Os via EX-RC1. The CPU-for-Panel is shipped with a 5 pin CANbus terminal block. This connector is marked with a pin assignment that is identical to the corresponding marking on the CPUfor-Panel. CANbus Wiring +V CANbus Power Supply (see Note) H CAN High Functional Ground L CAN Low -V CANbus Power & Signal Common Use a shielded twisted-pair cable. DeviceNet, shielded twisted-pair cable is recommended. When wiring each node, connect the cable shield to the functional ground point of the CANbus terminal block. Connect the CANbus cable shield to the system earth at only one point near the power supply. NOTE The CPU-for-Panel CANbus port is internally powered and does not require an external power-supply. This means that you can either connect the +V point in the CPU s CANbus connector to an external power supply, or leave it unconnected. Do not use the +V point for any other purpose. CANbus Termination Place termination resistors at each end of the CANbus network. Resistance must be set to 121Ω, 1/4W, 1%. DeviceNet cable connection: Helsinki tel. +358 9 540 4940 automation@klinkmann.fi St. Petersburg tel. +7 812 327 3752 klinkmann@klinkmann.spb.ru Moscow tel. +7 495 641 1616 moscow@klinkmann.spb.ru Yekaterinburg tel. +7 343 287 19 19 yekaterinburg@klinkmann.spb.ru Samara tel. +7 846 273 95 85 samara@klinkmann.spb.ru Кiev tel. +38 044 495 33 40 klinkmann@klinkmann.kiev.ua Riga tel. +371 6738 1617 klinkmann@klinkmann.lv Vilnius tel. +370 5 215 1646 post@klinkmann.lt Tallinn tel. +372 668 4500 klinkmann.est@klinkmann.ee Мinsk tel. +375 17 200 0876 minsk@klinkmann.com