PSU. User s manual. Rev. 0

Similar documents
PSU User s manual Rev. 0 January

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

ATV12H075M3 variable speed drive ATV kW - 1hp V - 3ph - with heat sink

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

ACOPOSinverter P74. User's Manual. Version: 2.20 (August 2016) Model no.: Original instruction

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate

ISOMETER isopv with coupling device AGH-PV

ATS01N232RT soft starter for asynchronous motor - ATS01-32 A V

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

Line Impedance Stabilization Network (LISN)

GDPS. Power supply unit for XtrapulsGem drive

LXM28AU07M3X motion servo drive - Lexium 28 - single and three phase V W

ATV310HU30N4E variable speed drive ATV310-3 kw - 4 hp V - 3 phase

ATS22D75Q soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW)

KUANTECH (SHEN ZHEN) COMPANY LIMITED KSAFD W1UK

ISOMETER isoev425/isoev425hc with coupling device AGH420

SIRIUS 200 U1X200A SRS U1X200A SRS USER S MANUAL

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

5 MICROMASTER 420 specifications

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

LXM32SD18M2 motion servo drive - Lexium 32-single phase supply voltage 115/230V - 0.5/1.kW

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

Typical Input current at 1.15A 0.65A 60 Watt 24VDC / 2.5A. 1.84A 1.0A 120 Watt 24VDC / 5.0A

PFC Mini TM Power Factor Corrected AC-DC Switchers

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW)

High Power Electronic Gear Installation and operation Guide

Rhino PSM Power Supplies. Operating Instructions

Energy 3000 Primary Switched Power Supply 3000W VE3PUID ,5/L programmable V/I

LXM32AD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

DPO A4. Description. Module with 4 digital outputs. Datasheet

RTU500 series Data Sheet Power Supply CP-E 24/2.5

5 MICROMASTER 440 specifications

SINAMICS. SINAMICS G120P dv/dt filter plus Voltage Peak Limiter. Safety information 1. General. Mechanical installation. Electrical installation 4

ATS22C41Q soft starter-ats22-control 220V-power 230V(110kW)/ V(220kW)

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual. Page 1 of 13

ATS22C17Q. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW)

Technical Requirements for High-voltage DC Power Feeding Interfaces of ICT equipment

E-Learning, DC drives DCS800 Hardware D5 D7, part 2

Installation Guide Controller Series E130/E230/E430

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

AC-DC Converter REC K10

Paper version. Release R09-20

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits.

Vector Drive - Troubleshooting Guide

ISOMETER isoev425 with coupling device AGH420

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

4.7 Digital Input/Output Module 07 DC digital inputs, 8 digital outputs, 8 configurable inputs/outputs, 24 V DC, CS31 system bus

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

HARDWARE MANUAL TMCM-1613 TMCM-1613-REC. Hardware Version V TRINAMIC Motion Control GmbH & Co. KG Hamburg, Germany.

Table of Contents. Safety. Attention. Warnings

ATS01N206RT soft starter for asynchronous motor - ATS01-6 A V

DELOMATIC - MULTI-FUNCTION SYSTEM PART 2 INSTALLATION INSTRUCTION

MC 11 EB-2 Power supply cabinet with external bus, AC version

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

Extension module for lighting control

VS-P Series. TDK-Lambda INSTRUCTION MANUAL

VLT Line Filter MCC 107 EMC Filter Series VLT Midi Drive FC 280 (K1 K3)

4.8 Digital Input/Output Module 07 DC 92 Contents Intended purpose Displays and operating elements on the front panel Electrical connection

MSR 2400W. Multi purpose Power System for Telecom and Industrial Applications. Nominal Output Voltage. Voltage Setting Range

INSTRUCTION SHEET. Eaton Logic Controller ELCB Controllers

IV-30 Operating Manual for Pulse Distributor Cassette with potential separation

ATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase

SPECIFICATION. For SWITCHING POWER SUPPLY M/N: MPD-F113-V

Line filter SINAMICS. SINAMICS G130 Line filter. Safety information 1. General 2. Mechanical installation 3. Electrical installation 4

POWERSOLVE ELECTRONICS LTD PSL400-XX series Conduction Cooled Power Supply Engineering Specification

Power supply CP-E 48/1.25 Primary switch mode power supply

Conveyor Belt Alignment Switches from IDEM

Power Supplies V7-T6-2 V7-T6-4 V7-T6-10 V7-T6-16 V7-T6-36 V7-T6-39 V7-T6-43

IES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v

P216. Condenser fan speed controller. Product bulletin. Features

RXB39.1. Room controller RXB. Communicating room controller for fan-coil applications FC-13

VL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features

Manual. Multi axis servo system AX8000. TDmIAX Version: Date:

Safety Technique. SAFEMASTER C Multifunction Safety Module BH 5910

EX-RC1 Remote I/O Adapter

Power supply CP-E 24/0.75 Primary switch mode power supply

PJ Open Frame Power Supply 24V 100W 1 Phase / PJ-24V100W A

ATV32HU30N4 variable speed drive ATV32-3 kw V - 3 phase - with heat sink

Installation, Operation, and Service Manual SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

Specification For 90 Watts Adapter Power Supply Model No: ADB002 Customer ID: 000G Revision: 4.0

RT4F-120V/20A-WAC RECTIFIER

Safety Standards. Model Number:

Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous

HARDWARE MANUAL TMCM-1613 TMCM-1613-REC. Hardware Version V TRINAMIC Motion Control GmbH & Co. KG Hamburg, Germany.

EFE300 / EFE400 EFE300M / EFE400M

Power supply CP-E 24/10.0 Primary switch mode power supply

HERCULES-5000 INSTRUCTION MANUAL

Power supply CP-C 24/5.0

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

RT4F-110V/25A RECTIFIER

Transcription:

PSU User s manual Rev. 0 2010 1

This user manual is for the standard version of the converter. All information in this user manual, including methods, techniques and concepts described herein, are proprietary information of Parker Hannifin Divisione S.B.C. EME Division and of its licensees, and they shall not be copied or used without express authorization. Parker Hannifin S.p.A. Divisione S.B.C. is committed to a continuous product upgrade and reserves the right to modify products and user manuals at any time without prior notice. No part of this user manual may be howsoever reproduced without previous consent by Parker Hannifin S.p.A. S.B.C. Division. Cod 1007141600 2

1. APPENDIX: PSU (POWER SUPPLY UNIT)... 4 1.1. Identfication... 4 1.2. Condition of utilization... 5 1.2.1. Filters... 5 1.2.2. Cable... 5 1.2.3. Grounding... 5 1.2.4. PSU protections... 5 1.2.5. Hardware PSU... 6 2. MOUNTING... 7 2.1. Connectors layout... 8 2.1.1. LED Status... 8 2.1.2. Signal connectors... 8 3. MODULE CONNECTIONS... 9 3.1.1. Rail system... 9 3.1.2. Communication connection... 9 3.2. Mains supply... 10 4. PARAMETERS SET-UP... 10 4.1.1. Voltage supply... 10 5. PSU ALARMS... 11 6. REVISION HISTORY OF THE USER MANUAL... 12 3

1.Appendix: PSU (Power Supply Unit) 1.1. Identfication 8 1 2 3 4 5 6 7 7 Explanation: Type designation 1 The complete order designation of the device (2-4). PSUPx0: Mains module 3AC 230...480V, nominal power in 1kW (10=10kW, 20=20kW) 2 D6: Designation nominal supply Configuration and parameterization interface 3 USB: USB connection Options 4 Mxx: I/O extension 5 Unique number of the particular device 6 Date of factory test Nominal supply voltage 7 Power Input: Input supply data Power Output: Output data 8 CE compliance 4

1.2. Condition of utilization 1.2.1. Filters A mains filter is required in the mains input line if the motor cable exceeds a certain length. Filtering can be provided centrally at the plant mains input or separately at the mains input to each axis combination. The following mains filters are available for independent utilization: PSU Order No. Condition P10 NFI03/01 Reference axis combination 6x10m P10 NFI03/02 Reference axis combination 6x50m P20 NFI03/03 Reference axis combination 6x50m 1.2.2. Cable PSU Model P10 P20 24VDC Section 4mm 2 (AWG8) 4mm 2 (AWG8) X9 Tightening torque 1.2 Nm (M5) 1.2 Nm (M5) Braking resistor Section 0.25 4mm 2 (AWG23 11) 0.25 4mm 2 (AWG23 11) X40 Tightening torque 0.5 Nm (M4) 0.5 Nm (M4) Mains Section 0.5 6mm 2 (AWG20 10) 0.5 16mm 2 (AWG20 6) X41 Tightening torque 1.2 Nm (M5) 1.7 Nm (M5) PE Section 10mm 2 (AWG6) 1.2.3. Grounding Connect the filter housing and the PSU to the cabinet frame, making sure that the contact area is adequate and that the connection has low resistance and low inductance. Never mount the filter housing and the device on paint-coated surfaces! 1.2.4. PSU protections Fuse (short circuit) Fuse Short-circuit proof Mains connection P10 25A MTP: S203UP-K 25(480VAC) Control voltage 24VDC Delayed action fuse, due to capacitive load conditional (internally protected with 3.15AT) P20 50A MTP: S203U-K 50(440VAC) 2 circuit breakers in line are required 5

1.2.5. Hardware PSU Description UdM Value Models - P10 P20 Supply voltage (3AC±10% _ 50-60Hz) VAC 230 400 480 230 400 480 Rated input current Arms 22 22 18 44 44 35 Rated output current Arms 18 18 15 36 36 30 Peak output current (2 sec) Arms 36 36 30 72 72 60 Power kw 6 10 10 12 20 20 Internal capacitance µf 550 1175 Total capacity applicable µf 2400 4000 External braking resistor Minimum braking resistance Ω 27 15 Recomended nominal power W 500 1500 500 3500 Pulse power (1s) kw 22 40 Maximum permissibile peak current A 13 15 Control stage Supply voltage V= 21 27VDC Max ripple V pkpk 0,5 Current A 0,2 0,3 EMC Filter - (see filters table) 6

2.Mounting 50,5mm 101mm 263mm 90 400mm 360mm 100mm 96mm Size 1 Size 2 PSU Weight 3,95 kg 6,5 kg Dimensions Lenght Height Depht (*) Size [mm] [mm] [mm] 1 50 2 100 (*) without connectors (**) with clamps 360 (410**) 270 7

2.1. Connectors layout Led Address setting USB interface RS485 24Vdc supply Main supply PE Braking resistor 2.1.1. LED Status STATUS LED green LED red No 24Vdc Off Off Error of main module Off On Pow. Volt. is built up - Flashes quickly Phase failure On Flashes slowly Address CPU active Flashes quickly - Address CPU completed Flashes slowly - Ready On Off 2.1.2. Signal connectors X41 Mains X40 Braking resistor 1 L1 +R + Braking resistor No short-circuit 2 L2 -R - Braking resistor protection 3 L3 PE PE 4 PE T1R Temperature switch (*) T2R Temperature switch (*) X9 24VDC 1 +24V 2 0Vdc (*) If the external braking resistor hasn t the temperature sensor, connect T1R to T2R. 8

3.Module connections 3.1.1. Rail system 24Vdc 0Vdc - DCbus Earth Protective covers: the user is responsible for protective covers and/or additional safety measures in order to prevent damages to persons and electric accidents. Use the dedicate fixing plates. On the right side of the last module, and on the left side of the first module insert the closing protection: + DCbus External components may not be connected to the rail system. Maximum no. of TPDM modules in a combination: 15 modules Caution! Risk of Electric Shock. Discharge time of the bus capacitor is approx. 5 minutes. 3.1.2. Communication connection IN OUT IN OUT Address setting Switch Value upon ON 1 16 2 32 3 64 Range: 0,16,32,48,64,80,96,112 Settings: left: OFF right: ON 1 st Module address = basic address IN OUT The communication in the axis combination is implemented via a SSK28 cable and double RJ45 sleeves on the device top. Beginning with the TPD (mains module) the connection is always made from X30 to X31 of the next device. On the first device (X31) and the last device (X30) in the multi-axis combination, a bus termination plug (BUS07/01) is required. Serial connection of up to 32 axes (or 15 modules) 9

3.2. Mains supply The PSU series is designed for fixed connection to TN networks (TN-C, TN-C-S or TN-S). Please note that the line-earth voltage may not exceed 300VAC. When grounding the neutral conductor, mains voltages of up to 480VAC are permitted. When grounding an external conductor (delta mains, two-phase mains), mains voltages (external conductor voltages) of up to 300VAC are permitted. Servo controllers which are to be connected to an IT network must be provided with a separating transformer. Then the PSU device is operated locally like in a TN network. The secondary sided center of the separating transformer must be grounded and connected to the PE connector of the PSU. 4.Parameters set-up N.B.: This operation must be executed only by the first axis connected to the PSU. 4.1.1. Voltage supply The default status of the drive is configured to 400VAC (=560V DC). For all other cases, it s necessary to set the correct value of the voltage [3-phase VAC supply * 2 = VDC bus ]: 230V AC 3-phase Pr206 = 325 400V AC 3-phase Pr206 = 565 480V AC 3-phase Pr206 = 680 To activate the new configuration, it s necessary to save the parameter and restart the PSU unit. 10

5.PSU alarms Malfunction error code Pr23 Pr24 24 b0 b1 Alarm Power supply not 3- phases Undervoltage PSU Check the main supply b2 Over voltage PSU Check the main supply b3 Over temperature b4 b5 Over load braking resistor Temperature switch Remedies Check the main supply. Check the set up of the parameter Pr206 (by the first axis connected to the PSU). Check the environment temperature. Check the cooling fans and for any restrictions to air flow. Check the cycle and if it s necessary use an external braking resistor. Check the connection of the temperature switch (X40). Short circuit on Braking control circuit. b6 Over load on DC-bus The current required is more than the current that b7 b14 Over current on DC-bus AC supply configuration can be supplied Check for any mechanical blockage and make sure the motor is the appropriate size for its current use. Check the motor connections and any phase-phase or phase-ground short-circuits. Check the length and type of the motor cable in use. Make sure a mains filter isn t connected to the motor! Check the configuration (Pr206 of the first axis connected to the PSU) of the mains supply because it s not correct. b15 Time-out data exchange Check the serial connection. 11

6.Revision history of the User Manual - Rev 0 2010 First edition For other informations log into website www.sbcelettronica.com. Arranges to the manual data can be made by the manufacturer without advance notice. The data shown in the manual correspond to the specifications relating to the revision date 12